Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Eddy-Mediated Turbulent Mixing of Oxygen in the Equatorial Pacific

In the tropical Pacific, weak ventilation and intense microbial respiration at depth give rise to a low dissolved oxygen (O 2 ) environment that is thought to be ventilated primarily by the equatorial current system (ECS). The role of mesoscale eddies and vertical mixing as potential pathways of O 2 supply in this region, however, remains poorly known due to sparse observations and coarse model resolution. Using an eddy resolving simulation of ocean circulation and biogeochemistry, we assess the contribution of these processes to the O 2 budget balance and find that vertical mixing of O 2 , which is modulated by the surface wind speed and the vertical shear of the eddying currents, contributes substantially to the replenishment of O 2 in the upper equatorial Pacific thermocline, complementing the advective supply of O 2 by the ECS and meridional circulation at depth. These transport processes vary seasonally in conjunction with the wind: mixing of O 2 into the upper thermocline is strongest during boreal summer and fall when the vertical shear and eddy kinetic energy are intensified. The relationship between eddy activity and the downward mixing of O 2 arises from the modulation of equatorial turbulence by Tropical Instability Waves via their impacts on the vertical shear. This interaction of processes across scales sustains a local pathway of O 2 delivery into the equatorial Pacific interior and highlights the need for adequate observations and models of turbulent mixing and mesoscale processes for understanding and predicting the fate of the tropical Pacific O 2 content in a warmer and more stratified ocean.

Eddy-Mediated↗

Review of Lunar Dust Computational Fluid Dynamic Model Development, Applications, and Validation for Habitable Volumes

As humans look to return to the lunar surface, Environmental Control and Life Support Systems (ECLSS) must be able to control lunar dust concentrations to minimize impacts to crew health and equipment within the cabin environment. Lunar dust is abrasive and can deteriorate the performance of spacesuits and equipment inside of habitable volumes. Development and validation of computational fluid dynamic (CFD) models assist in understanding the behavior of lunar dust and aids in design of ECLS systems. Previous analysis efforts include modeling the effect of lunar dust on the crew's health, devices to filter out lunar dust from ventilation systems, and module ventilation to predict where lunar dust would settle in modules. This paper is a literature review of the modeling and testing techniques currently used in industry to analyze how lunar dust will affect ECLSS functionality. Details about lunar dust material properties and knowledge gaps are also examined.

Monica Mah↗

The Sensitivity of the Equatorial Pacific ODZ to Particulate Organic Matter Remineralization in A Climate Model Under Pre-Industrial Conditions

Marine oxygen plays a fundamental role in regulating the transfer of organic carbon and nutrients to their dissolved inorganic forms, serving as the terminal electron acceptor for heterotrophic respiration. Oxygen can become limiting to these processes in coastal and open-ocean oxygen deficient zones (ODZs). The maintenance of ODZs depends on the balance between physical processes such as ventilation and biogeochemical processes such as remineralization. These two processes act in opposing directions on ODZs, with ventilation responsible for transporting oxygen from the surface, where it is near saturation with the partial pressure of O2 in the atmosphere, to deeper oxygen-depleted layers, and remineralization acting to consume oxygen through biogeochemical processes such as microbial degradation throughout the water column. Remineralization is represented in all CMIP6 models, but the actual parameterizations, as well as their magnitude, are widely varying. In this study, we examine the sensitivity to remineralization of the equatorial Pacific ODZ O2 ol/kg) in a model; the NASA GISS Ocean Biogeochemical Model (NOBM-G) embedded in the NASA-GISS coupled atmosphere-ocean model. We find that increasing the remineralization rate shoals the ODZ onset depth (i.e. the regionally averaged upper bound of the ODZ), and decreases ODZ volume and regional-averaged thickness. Changes in biological consumption and vertical convergence of oxygen are identified as the primary contributors to changes in ODZ onset depth. ODZ thickness is mainly influenced by the shoaling of the bottom boundary of the ODZ, which decreases with maximum remineralization rate due to decreasing oxygen consumption and increasing horizontal oxygen convergence in deep waters. On the other hand, vertically-averaged ODZ area has a more complex, non-monotonic relationship with maximum remineralization rate. While these findings suggest an important role for remineralization in determining the shape of the ODZ in our model, the relative importance of remineralization vs. other physical parameterizations remains to be established. While our results reflect the structure of our ocean biogeochemical model, the relationship of remineralization to ODZ characteristics in other models should be examined to better inform model inter-comparisons.

Oxygen-deficient zone↗

Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates

Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

attic↗

2013 R&D 100 Award: DNATrax could revolutionize air quality detection and tracking

A team of LLNL scientists and engineers has developed a safe and versatile material, known as DNA Tagged Reagents for Aerosol Experiments (DNATrax), that can be used to reliably and rapidly diagnose airflow patterns and problems in both indoor and outdoor venues. Until DNATrax particles were developed, no rapid or safe way existed to validate air transport models with realistic particles in the range of 1-10 microns. Successful DNATrax testing was conducted at the Pentagon in November 2012 in conjunction with the Pentagon Force Protection Agency. This study enhanced the team's understanding of indoor ventilation environments created by heating, ventilation and air conditioning (HVAC) systems. DNATrax are particles comprised of sugar and synthetic DNA that serve as a bar code for the particle. The potential for creating unique bar-coded particles is virtually unlimited, thus allowing for simultaneous and repeated releases, which dramatically reduces the costs associated with conducting tests for contaminants. Among the applications for the new material are indoor air quality detection, for homes, offices, ships and airplanes; urban particulate tracking, for subway stations, train stations, and convention centers; environmental release tracking; and oil and gas uses, including fracking, to better track fluid flow.

54 ENVIRONMENTAL SCIENCES↗

Recent Upgrades at the Safety and Tritium Applied Research Facility

This paper gives a brief overview of the Safety and Tritium Applied Research (STAR) facility operated by the Fusion Safety Program (FSP) at the Idaho National Laboratory (INL). FSP researchers use the STAR facility to carry out experiments in tritium permeation and retention in various fusion materials, including wall armor tile materials. FSP researchers also perform other experimentation as well to support safety assessment in fusion development. This lab, in its present two-building configuration, has been in operation for over ten years. The main experiments at STAR are briefly described. This paper discusses recent work to enhance personnel safety at the facility. The STAR facility is a Department of Energy less than hazard category 3 facility; the personnel safety approach calls for ventilation and tritium monitoring for radiation protection. The tritium areas of STAR have about 4 to 12 air changes per hour, with air flow being once through and then routed to the facility vent stack. Additional radiation monitoring has been installed to read the laboratory room air where experiments with tritium are conducted. These ion chambers and bubblers are used to verify that no significant tritium concentrations are present in the experiment rooms. Standby electrical power has been added to the facility exhaust blower so that proper ventilation will now operate during commercial power outages as well as the real-time tritium air monitors.

tritium facility upgrades↗

U.S. Light-duty Vehicle Air Conditioning Fuel Use and the Impact of Four Solar/Thermal Control Technologies

The U.S. uses 7.6 billion gallons of fuel per year for vehicle air conditioning (A/C), equivalent to 5.7 percent of the total national light-duty vehicle (LDV) fuel use. This equates to 30 gallons/year per vehicle, or 23.5 grams (g) of carbon dioxide (CO2) per mile, for an average U.S. vehicle. A/C is a significant contribution to national fuel use; therefore, technologies that reduce A/C loads may reduce operational costs, A/C fuel use, and CO2 emissions. Since A/C is not operated during standard EPA fuel economy testing protocols, EPA provides off-cycle credits to encourage OEMs to implement advanced A/C technologies that reduce fuel use in the real world. NREL researchers assessed thermal/solar off-cycle credits available in the U.S. Environmental Protection Agency's (EPA's) Final Rule for Model Year 2017 and Later Light-Duty Vehicle Greenhouse Gas Emissions and Corporate Average Fuel Economy. Credits include glazings, solar reflective paint, and passive and active cabin ventilation. Implementing solar control glass reduced CO2 emissions by 2.0 g/mi, and solar reflective paint resulted in a reduction of 0.8 g/mi. Active and passive ventilation strategies only reduced emissions by 0.1 and 0.2 g/mi, respectively. The national-level analysis process is powerful and general; it can be used to determine the impact of a wide range of new vehicle thermal technologies on fuel use, EV range, and CO2 emissions.

30 DIRECT ENERGY CONVERSION↗

Numerical Simulation Applications in the Design of EGS Collab Experiment 1

The United States Department of Energy, Geothermal Technologies Office (GTO) is funding a collaborative investigation of enhanced geothermal systems (EGS) processes at the meso-scale. This study, referred to as the EGS Collab project, is a unique opportunity for scientists and engineers to investigate the creation of fracture networks and circulation of fluids across those networks under in-situ stress conditions. The EGS Collab project is envisioned to comprise three experiments and the site for the first experiment is on the 4850 Level (4,850 feet below ground surface) in phyllite of the Precambrian Poorman formation, at the Sanford Underground Research Facility, located at the former Homestake Gold Mine, in Lead, South Dakota. Principal objectives of the project are to develop a number of intermediate-scale field sites and to conduct well-controlled in situ experiments focused on rock fracture behavior and permeability enhancement. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO's flagship EGS research effort. As noted, outcomes from the EGS Collab project experiments will serve as benchmarks for computer code verification, but numerical simulation additionally plays an essential role in designing these meso-scale experiments. This paper describes specific numerical simulations supporting the design of Experiment 1, a field test involving hydraulic stimulation of two fractures from notched sections of the injection borehole and fluid circulation between sub-horizontal injection and production boreholes in each fracture individually and collectively, including the circulation of chilled water. Whereas the mine drift allows for accurate and close placement of monitoring instrumentation to the developed fractures, active ventilation in the drift cooled the rock mass within the experimental volume. Numerical simulations were executed to predict seismic events and magnitudes during stimulation, initial fracture orientations for smooth horizontal wellbores, pressure requirements for fracture initiation from notched wellbores, fracture propagation during stimulation between the injection and production boreholes, tracer travel times between the injection and production boreholes, produced fluid temperatures with chilled water injections, pressure limits on fluid circulation to avoid fracture growth, temperature environment surrounding the 4850 Level drift, and fracture propagation within a stress field altered by drift excavation, ventilation cooling, and dewatering.

15 GEOTHERMAL ENERGY↗

Window to the Hot Cell: The Challenges of Repairing a Specialized Nuclear Containment

Here, at the Idaho National Laboratory (INL) nuclear R&D site we come across a myriad of challenges and health hazards. Recently, a first time activity for the INL was to replace a hot cell window put in place circa 1977. This job evolution was complex in nature and involved several health and safety hazards. A hot cell is a containment designed to protect workers from radioactivity yet continue to allow work with remote handled tools and windows for visibility. The hot cell window weighed approximately 14,000 lbs. and was held in place by 1.6 cubic yards of high density grout. Removal of the window required abrasive grout removal techniques, radiological control efforts, specialized ventilation, and personal protective equipment utilization. In order to contain the large amounts of dust from the removal of concrete and potential contamination exposure a special containment tent and ventilation system was designed to protect workers in the surrounding areas from dust and debris. Once the window was removed it had to be further taken apart for shipment. While performing this activity, several lead sheets and lead wool was required to be removed. Overall it took 38 days to accomplish this task and had several organizations involved. There were no injuries or unexpected conditions that occurred during this job task. This was the first time this activity was performed at the INL and was completed in a successful manner. Further windows are set to be replaced in the near future.

99 GENERAL AND MISCELLANEOUS↗

The De-Icing Comparison Experiment – ARM Contribution (DICEXACO) Field Campaign Report

Longwave and shortwave radiative fluxes are fundamental quantities regularly observed globally using broadband radiometers. In regions conducive to frost, rime, and snow, ice frequently builds up on sensor windows, contaminating measurements. Since icing occurs under particular meteorological conditions, associated data loss constitutes a climatological bias. Furthermore, the signal caused by ice is difficult to distinguish from that of clouds, hampering efforts to identify contaminated data in post-processing. Because of the sensitivity of radiometers to internal temperature instabilities, there are limitations to using heat as a de-icing method, and consequently substantial amounts of data are lost. The De-Icing Comparison Experiment (D-ICE) was a campaign carried out at $Utqia\dot{g}vik$ (formerly known as Barrow) and Oliktok Point, Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational stations run by the NOAA Global Monitoring Division (GMD) at NOAA’s Barrow Atmospheric Baseline Observatory. D-ICE also evaluated the sky radiometer (SKYRAD) systems at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) and Oliktok Point (OLI; third ARM Mobile Facility [AMF3]) observatories. In total, 34 systems were evaluated (8 of which were SKYRAD radiometers). All radiometers were monitored continuously using cameras, and a total of more than one million images of sensor domes were archived collectively between the stations. Data collected as part of D-ICE by NOAA can be found through the project web page, https://www.esrl.noaa.gov/psd/arctic/d-ice/. The DICEXACO component of D-ICE (https://www.arm.gov/research/campaigns/nsa2017dicexaco) are the images collected at 10-min intervals at both OLI and NSA and are the subject of this report. Two cameras were installed at each ARM station, one directed towards the SKYRAD tracker and the other towards the SKYRAD global precision spectral pyranometer (PSP).

Oliktok Point, North Slope of Alaska, SKYRAD, pyra↗

Innovative Approach to SCC Inspection and Evaluation of Canister in Dry Storage

This final report is summarized four years of work of awarded project number DE-NE0008442\IRP-15-9318, title as: “Innovative Approach to SCC Inspection and Evaluation of Canister in Dry” supported by Nuclear Energy University Program\Integrated Research Program, NEUP\IRP, where last year is an extension of no cost project. This research work is focused on the possible degradation of dry storage canister holding used nuclear fuel (UNF), due to exposure of marine atmospheric environment. The canister usually designed from a welded austenitic stainless-steel of types 304 or 316, encased in a concrete shell known as an overpack. This canister designed and licensed for 20 years with an extension period need to be determined, in addition 20 years or more. These casks are located throughout the country in Independent Spent Fuel Storage Installations (IFSFIs) often on the site close to nuclear power plants, that are often located in coastal or lake-side regions where a marine atmospheric salt air environment exist. As a result of several recent decisions, such as not pursuing Yucca Mountain as a long-term geologic repository storage facility for UNF and the cancellation of the construction of a reprocessing facility in the 1980s due to proliferation risks, interim dry storage facilities for long-term storage are vital option for the immediate future of nuclear energy technology. One of the primary concerns with respect to the long-term performance of the storage casks is the potential for corrosion initiation due to deliquescence of salts deposited on the canister surface as aerosols; in regions of high residual weld stresses, this may lead to localized stress corrosion cracking (SCC). Dust and aerosols in the air being drawn though ventilation openings in the overpacks of passively ventilated dry canister storage systems may be deposited on the stainless-steel canister outer surfaces. Under these conditions, localized corrosion attack can occur. Chlorides ions deliquescence on the canister surface, a process by which the salts essentially pull moisture out of the air, creating a concentrated salt brine on the canister surface. Chloride-induced stress corrosion cracking (CISCC) of welded zones is of special concern, as it a well-documented mode of attack for austenitic stainless steels marine environments, and many independent spent fuel storage installations (ISFSIs) are located in coastal areas. Recent canister inspections have shown that chloride salts are present on the surface of in-service canisters at near-marine settings. However, canister surface inspections of satisfactory resolution to detect SCC have never been carried out in details, because access to the canister surfaces through vents in the overpacks is extremely limited, and high radiation fields make removal of the canisters from the overpacks undesirable. Although no significant corrosion damage has not been detected up to date, there is concern that this may lead to pitting corrosion, which could in turn develop into stress corrosion cracking, causing canister structural failure. The initiation and propagation of pitting corrosion has been widely studied in full immersion conditions, but limited studies have been done on marine atmospheric conditions, which is a focus of this work, these includes laboratory and field experimentally and propagation rate modeling of pitting and transition to crack, and crack propagation rate. It is known, however, that the rate of atmospheric corrosion can be affected by variations in relative humidity (RH), salt density, salt type, droplet area, temperature and stainless-steel microstructure and residual stress particularly in welded zones of canisters. The integrated research program has identified potential deterioration mechanisms for the stainless-steel canisters containing the UNF in dry storage that require detailed research and investigation and will have an impact on the performance of long-term interim storage under the normal and extreme environmental conditions experienced during the duration of this storage. The prediction and monitoring of canister corrosion processes while in storage can provide important data for the assessment of interim storage performance and the safety to the public. This report comprises of mainly the published results in different journals and covering a wide range spectrum from susceptible stainless-steel types 304\316 microstructural analysis through the implant test at atmospheric environment, residual stress analysis of mockup canister and simulation, inspection methodology includes nonlinear ultrasound and vibro-thermography and stochastic modeling and simulation of pits propagation rates and transition to cracks. Description of field specimens installed at ISFSI of Main Yankee is given in the following chapters and will be analyzed in the coming future and serves as an important data for a stochastic analysis as it was drawn from the publications and reports described in this report. The purpose of this report is to bring together the project efforts that includes improving in our understanding of structural aging performance at current dry storage casks fleet at ISFSIs in the context of remedial maintenance and inspection applications technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding Occupancy Patterns in a Commercial Space

Heating, ventilation, and air conditioning (HVAC) is a prime source of energy consumption in the US. In 2006, approximately 35% of energy in the US was used for HVAC [1]. Usually building operators use a static schedule for controlling HVAC systems without having a deeper understanding of how many people use the building at different times of the day. In addition, HVAC systems operate by assuming maximum occupancy in each room, which leads to a significant energy waste, e.g., an HVAC system providing ventilation for 30 people when there are only 10 people in a room. Considering how many people use different rooms at different times of the day is very crucial for achieving building energy efficiency and providing occupant comfort. There have been several attempts to collect long term occupancy patterns from office buildings, e.g., Mitsubishi’s Electronic Research Lab (MERL) dataset [14] and Colorado School of Mines (CSMBB) dataset. However, PIR motion detectors are used in these projects for sensing occupancy and hence these datasets only reflect whether a room is occupied or not without revealing the actual person count. Similar datasets are also collected from households. Only a few datasets from commercial spaces capture actual person count, and even in these cases, the data collection period was very limited, e.g., in [3] only 5 days of occupancy data is collected as ground truth. We are the first to collect long term (9 months) occupancy data (people count) from an 11,000 square foot commercial office (second floor of Bosch Research and Technology Center Pittsburgh). In this paper, we outline some statistical results from our empirical study and explore their implications for saving energy.

42 ENGINEERING↗

Are low-cost sensors good enough for IAQ controls?

Over the past few years there have been advances in sensing of some pollutants, primarily particles, that might lead to ventilation controls based on direct sensing of pollutants – particularly those relating to health. In this study we evaluated low-cost (about $200 US) IAQ monitors that measured PM2.5 - the most important health-related pollutant in indoor air. Controlled laboratory tests were carried out with known sources of particles (cooking, cleaning, candles, cigarettes) and by comparing the IAQ monitors response to research-grade and reference measurement methods. The results show a wide range of performance with the better IAQ monitors able to detect most particle sources/events and the worst ones detecting almost none. The best devices perform well enough to reliably operate a ventilation or filtration system but do not always report the correct magnitude of PM2.5 so there are restrictions on their use for calculating health effects.

Walker, Iain↗

Rooftop Unit Replacement: Target's Rooftop Unit Replacement Program

This case study describes how Target developed an optimized, re-engineered process that integrates several energy-efficiency measures such as reduced lighting loads, improved roof insulation, optimized ventilation, and more accurate load calculations through its rooftop unit (RTU) replacement program. Target's approach achieved ongoing energy reduction, operations and maintenance reduction, and improved heating, ventilating, and air-conditioning (HVAC) performance by reducing equipment cycling.

HVAC, Rooftop Unit, RTU, commercial, retail, air c↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Computational Risk Analysis of Propane Releases in Maintenance Facilities

Liquefied petroleum gas (LPG) is a viable, cleaner alternative to traditional diesel fuel used in busses and other heavy-duty vehicles and could play a role in helping the US meet its lower emission goals. While the LPG industry has focused efforts on developing vehicles and fueling infrastructure, we must also establish safe parameters for maintenance facilities which are servicing LPG fueled vehicles. Current safety standards aid in the design of maintenance facilities, but additional quantitative analysis is needed to prove safeguards are adequate and suggest improvements where needed. In this report we aim to quantify the amount of flammable mass associated with propane releases from vehicle mounted fuel vessels within enclosed garages. Furthermore, we seek to qualify harm mitigation with variable ventilations and facility layout. To accomplish this we leverage validated computational resources at Sandia National Laboratories to simulate various release scenarios representative of real world vehicles and maintenance facilities. Flow solvers are used to predict the dynamics of fuel systems as well as the evolution of propane during release events. From our simulated results we observe that both inflow and outflow ventilation locations play a critical role in reducing flammable cloud size and potential overpressure values during a possible combustion event.

03 NATURAL GAS↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Healthy Buildings Guide for Small Businesses: A Quick Reference to Improve Indoor Air Quality (Restaurants Excluded)

Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time – not just during a public health crisis – and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures – the building owner and business owner can be different parties – so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.

air filtration↗