Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Auger Heating and Thermal Dissipation in Zero-Dimensional CdSe Nanocrystals Examined Using Femtosecond Stimulated Raman Spectroscopy

In this paper, we report femtosecond stimulated Raman spectroscopy (FSRS) measurements on dispersions of CdSe semiconductor nanocrystals (NCs) as a function of particle size and pump fluence. Upon photoexcitation we observe depletion of stimulated Raman gain corresponding to generation of longitudinal optical (LO) phonons followed by recovery on picosecond timescales. At higher fluences, production of multiple excitons slows recovery of FSRS signals, which we attribute to sustained increases of LO phonon populations due to multiexcitonic Auger heating. Additionally, owing to discretized electronic structure of these NCs, such heating cannot be readily monitored via electronic spectroscopic analysis of high energy band tails as has been performed for higher-dimensionality materials. Notably, recovery timescales exceed those of the biexcitonic Auger recombination process and as such reveal overall thermalization timescales likely owing to an acoustic phonon thermalization bottleneck that dictates the cooling timescale.

36 MATERIALS SCIENCE↗

Laser-metal interaction dynamics during additive manufacturing resolved by detection of thermally-induced electron emission

In situ monitoring is required to improve the understanding and increase the reliability of additive manufacturing methods such as laser powder bed fusion (LPBF). Current diagnostic methods for LPBF capture optical images, X-ray radiographs, or measure the emission of thermal or acoustic signals from the component. Herein, a methodology based on the thermal emission of electrons - thermionic emission - from the metal surface during LPBF is proposed which can resolve laser-material interaction dynamics. The high sensitivity of thermionic emission to surface temperature and surface morphology is revealed to enable precise determination of the transition between conduction and keyhole mode melting regimes. Increases in thermionic emission are correlated to laser scanning conditions that give rise to pore formation and regions where surface defects are pronounced. The information presented here is a critical step in furthering our understanding and validation of laser-based metal additive manufacturing.

36 MATERIALS SCIENCE↗

Radiation damage characterization in reactor pressure vessel steels with nonlinear ultrasound

Nuclear generation currently accounts for roughly 20% of the US baseload power generation. Yet, many US nuclear plants are entering their first period of life extension and older plants are currently undergoing assessment of technical basis to operate beyond 60 years. This means that critical components, such as the reactor pressure vessel (RPV), will be exposed to higher levels of radiation than they were originally intended to withstand. Radiation damage in reactor pressure vessel steels causes microstructural changes such as vacancy clusters, precipitates, dislocations, and interstitial loops that leave the material in an embrittled state. The development of a nondestructive evaluation technique to characterize the effect of radiation exposure on the properties of the RPV would allow estimation of the remaining integrity of the RPV with time. Recent research has shown that nonlinear ultrasound is sensitive to radiation damage. The physical effect monitored by nonlinear ultrasonic techniques is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave, arising from the interaction of the ultrasonic wave with microstructural features such as dislocations, precipitates, and their combinations. Current findings relating the measured acoustic nonlinearity parameter to increasing levels of neutron fluence for different representative RPV materials are presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Illuminating the North Korean nuclear explosion test in 2017 using remote infrasound observations

North Korea conducted its sixth underground nuclear explosion test (mb 6.3) on 2017 September 3. The underground explosion produced substantial low-frequency atmospheric waves, which were detected by infrasound arrays located up to a distance of 566 km. These infrasound waves are formed by the conversion of seismic energy to acoustic energy across the lithosphere–atmosphere interface. While infrasound records at regional distances produce estimates of ground motion amplitude over spatially extended regions covering about 26 500 km 2 , 3-D full seismo-acoustic simulations within the lithosphere and atmosphere provide quantitative information about seismo-acoustic energy partitioning. Our results demonstrate the capability of remote infrasound observations combined with 3-D propagation modelling to further develop discrimination methods for underground sources. These results contribute to enhance the confidence of source identification and characterization in nuclear test monitoring research, which is essential for the enforcement of the Comprehensive Nuclear-Test-Ban Treaty.

58 GEOSCIENCES↗

Nondestructive Evaluation of Adhesively Bonded Joints

The final report consists of 5 published papers in referred journals and a technical letter to the technical monitor. These papers include the following: (1) Comparison of the effects of debonds and voids in adhesive; (2) On the peak shear stresses in adhesive joints with voids; (3) Nondestructive evaluation of adhesively bonded joints by acousto-ultrasonic technique and acoustic emission; (4) Multiaxial fatigue life evaluation of tubular adhesively bonded joints; (5) Theoretical and experimental evaluation of the bond strength under peeling loads. The letter outlines the progress of the research. Also included is preliminary information on the study of nondestructive evaluation of composite materials subjected to localized heat damage. The investigators studied the effects of localized heat on unidirectional fiber glass epoxy composite panels. Specimens of the fiber glass epoxy composites were subjected to 400 C heat for varying lengths of time. The specimens were subjected to nondestructive tests. The specimens were then pulled to their failure and acoustic emission of these specimens were measured. The analysis of the data was continuing as of the writing of the letter, and includes a finite element stress analysis of the problem.

Nayeb-Hashemi, Hamid↗

Improved Open-Microphone Speech Recognition

Many current and future NASA missions make extreme demands on mission personnel both in terms of work load and in performing under difficult environmental conditions. In situations where hands are impeded or needed for other tasks, eyes are busy attending to the environment, or tasks are sufficiently complex that ease of use of the interface becomes critical, spoken natural language dialog systems offer unique input and output modalities that can improve efficiency and safety. They also offer new capabilities that would not otherwise be available. For example, many NASA applications require astronauts to use computers in micro-gravity or while wearing space suits. Under these circumstances, command and control systems that allow users to issue commands or enter data in hands-and eyes-busy situations become critical. Speech recognition technology designed for current commercial applications limits the performance of the open-ended state-of-the-art dialog systems being developed at NASA. For example, today's recognition systems typically listen to user input only during short segments of the dialog, and user input outside of these short time windows is lost. Mistakes detecting the start and end times of user utterances can lead to mistakes in the recognition output, and the dialog system as a whole has no way to recover from this, or any other, recognition error. Systems also often require the user to signal when that user is going to speak, which is impractical in a hands-free environment, or only allow a system-initiated dialog requiring the user to speak immediately following a system prompt. In this project, SRI has developed software to enable speech recognition in a hands-free, open-microphone environment, eliminating the need for a push-to-talk button or other signaling mechanism. The software continuously captures a user's speech and makes it available to one or more recognizers. By constantly monitoring and storing the audio stream, it provides the spoken dialog manager extra flexibility to recognize the signal with no audio gaps between recognition requests, as well as to rerecognize portions of the signal, or to rerecognize speech with different grammars, acoustic models, recognizers, start times, and so on. SRI expects that this new open-mic functionality will enable NASA to develop better error-correction mechanisms for spoken dialog systems, and may also enable new interaction strategies.

Abrash, Victor↗

Magnetoelastic sensors in combination with nanometer-scale honeycombed thin film ceramic TiO2 for remote query measurement of humidity

Ribbonlike magnetoelastic sensors can be considered the magnetic analog of an acoustic bell; in response to an externally applied magnetic field impulse the sensors emit magnetic flux with a characteristic resonant frequency. The magnetic flux can be detected external to the test area using a pick-up coil, enabling query remote monitoring of the sensor. The characteristic resonant frequency of a magnetoelastic sensor changes in response to mass loads. [L.D. Landau and E. M. Lifshitz, Theory of Elasticity, 3rd ed. (Pergamon, New York, 1986). p. 100].Therefore, remote query chemical sensors can be fabricated by combining the magnetoelastic sensors with a mass changing, chemically responsive layer. In this work magnetoelastic sensors are coated with humidity-sensitive thin films of ceramic, nanodimensionally porous TiO2 to make remote query humidity sensors. c2000 American Institute of Physics.

NASA Discipline Life Sciences Technologies↗

Computational Modeling and Experimental Characterization of Martensitic Transformations in Nicoal for Self-Sensing Materials

Fundamental changes to aero-vehicle management require the utilization of automated health monitoring of vehicle structural components. A novel method is the use of self-sensing materials, which contain embedded sensory particles (SP). SPs are micron-sized pieces of shape-memory alloy that undergo transformation when the local strain reaches a prescribed threshold. The transformation is a result of a spontaneous rearrangement of the atoms in the crystal lattice under intensified stress near damaged locations, generating acoustic waves of a specific spectrum that can be detected by a suitably placed sensor. The sensitivity of the method depends on the strength of the emitted signal and its propagation through the material. To study the transition behavior of the sensory particle inside a metal matrix under load, a simulation approach based on a coupled atomistic-continuum model is used. The simulation results indicate a strong dependence of the particle's pseudoelastic response on its crystallographic orientation with respect to the loading direction and suggest possible ways of optimizing particle sensitivity. The technology of embedded sensory particles will serve as the key element in an autonomous structural health monitoring system that will constantly monitor for damage initiation in service, which will enable quick detection of unforeseen damage initiation in real-time and during onground inspections.

Wallace, T. A.↗

ASTRID sodium cooled fast reactor: Program for improving in service inspection and repair

In the frame of the CEA, EDF, AREVA coordinated research program for the development of Generation IV sodium-cooled fast reactors (SFR), the ASTRID project was launched in 2010. For the future prototype, the improvement of in-service inspection and repair (ISI and R) capabilities was identified as a major issue. Following the pluri-annual SFR research program, the ISI and R main R and D axes remain: i) improvement of the primary system conceptual design, ii) development of measurement and inspection techniques (continuous monitoring instrumentation and periodic inspection tools), iii) accessibility and associated robotics, and iv) development and validation of repair processes. Associated ISI and R needs are being defined through an iterative method between designers and instrumentation specialists: adaptation of the Design to ISI and R requirements, fission chamber development, validation of the ultrasonic and chemical transducers, of ultrasonic non destructive simulation, of acoustic surveillance, of laser repair intervention processes, of connected robotic equipment. Moreover, CEA, as leader of the ASTRID Project, is willing to find new contributors, partners or suppliers, in order to get innovative, diversified, exhaustive and efficient solutions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-G-JeP1-09: Evaluation of Transperineal Ultrasound Imaging as a Potential Solution for Target Tracking During Ablative Body Radiotherapy for Prostate Cancer

Purpose: Prostate SABR is emerging as a clinically viable, potentially cost effective alternative to prostate IMRT but its adoption is contingent on providing solutions for accurate tracking during beam delivery. Our goal is to evaluate the performance of the Clarity Autoscan ultrasound monitoring system for inter-fractional prostate motion tracking in both phantoms and in-vivo. Methods: In-vivo evaluation was performed under IRB protocol to allow data collection in prostate patients treated with VMAT whereby prostate was imaged through the acoustic window of the perineum. The probe was placed before KV imaging and real-time tracking was started and continued until the end of treatment. Initial absolute 3D positions of fiducials were estimated from KV images. Fiducial positions in MV images subsequently acquired during beam delivery were compared with predicted positions based on Clarity estimated motion. Results: Phantom studies with motion amplitudes of ±1.5, ±3, ±6 mm in lateral direction and ±2 mm in longitudinal direction resulted in tracking errors of −0.03 ± 0.3, −0.04 ± 0.6, −0.2 ± 0.9 mm, respectively, in lateral direction and −0.05 ± 0.30 mm in longitudinal direction. In phantom, measured and predicted fiducial positions in MV images were within 0.1 ± 0.6 mm. Four patients consented to participate in the study and data was acquired over a total of 140 fractions. MV imaging tracking was possible in about 75% of the time (due to occlusion of fiducials) compared to 100% with Clarity. Overall range of estimated motion by Clarity was 0 to 4.0 mm. In-vivo fiducial localization error was 1.2 ± 1.0 mm compared to 1.8 ± 1.9 mm if not taking Clarity estimated motion into account. Conclusion: Real-time transperineal ultrasound tracking reduces uncertainty in prostate position due to intrafractional motion. Research was supported by Elekta.

60 APPLIED LIFE SCIENCES↗

A dedicated mirror-magnet experiment to study quench characteristics and dependencies in $Nb_{3}Sn$ coils and explore improvements of diagnostics capabilities

A single Nb3Sn short quadrupole coil in a mirror-magnet configuration was employed to investigate a wide range of phenomena and to serve as test-bed for diagnostics developments. A configurable array of spot-heaters was installed on the inner coil surface for control of induced quench conditions. Several different quench antenna arrays were positioned along the coil inner surface, and included significant sensor overlap for assessment of their relative efficiency and operation. Multiple acoustic sensors were placed on the pole and at coil ends. Optical fibers in grid configurations were put in different places on the coil and magnet for strain assessment, along with standard resistive strain gauges. Current spikes in the magnet circuit were monitored. This plethora of instrumentation aimed to support investigations on induced and spontaneous quenches, among other goals, and was supplemented by standard voltage-tap-based measurements. Voltage tap data of induced quenches from various spot-heater configurations was investigated for similarities to voltage development in spontaneous quenches. Quench antennas provided insights about current redistribution in the quenching coil and coil splices. The Quench Current-boosting Device was applied and the effect on coil training examined. This paper describes motivations behind the research, the overall test setup and main results.

Stoynev, Stoyan [Fermilab]↗

Remote sensing operations (multispectral scanner and photographic) in the New York Bight, 22 September 1975

Ocean dumping of waste materials is a significant environmental concern in the New York Bight. One of these waste materials, sewage sludge, was monitored in an experiment conducted in the New York Bight on September 22, 1975. Remote sensing over controlled sewage sludge dumping included an 11-band multispectral scanner, fiver multispectral cameras and one mapping camera. Concurrent in situ water samples were taken and acoustical measurements were made of the sewage sludge plumes. Data were obtained for sewage sludge plumes resulting from line (moving barge) and spot (stationary barge) dumps. Multiple aircraft overpasses were made to evaluate temporal effects on the plume signature.

Johnson, R. W.↗

Automatic electronic fish tracking system

A newly developed electronic fish tracking system to automatically monitor the movements and migratory habits of fish is reported. The system is aimed particularly at studies of effects on fish life of industrial facilities which use rivers or lakes to dump their effluents. Location of fish is acquired by means of acoustic links from the fish to underwater Listening Stations, and by radio links which relay tracking information to a shore-based Data Base. Fish over 4 inches long may be tracked over a 5 x 5 mile area. The electronic fish tracking system provides the marine scientist with electronics which permit studies that were not practical in the past and which are cost-effective compared to manual methods.

Osborne, P. W.↗

Acoustic Techniques for Density and Mass Flow in Enrichment Plants

In recent years, the IAEA has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by advanced centrifuge technologies and the growth in capacity at gaseous centrifuge enrichment plants (GCEPs) [1; 2]. A prominent theme in the development of a new generation of safeguards measures for GCEPs is the use of permanently installed, unattended instruments that can provide continuous monitoring of facility activities, while also reducing the need for on-site inspections [3]. For example, the U.S. Support Program to the IAEA leads the development of an On-Line Enrichment Monitor (OLEM) [4; 5] and an Unattended Cylinder Verification Station (UCVS) [6]. OLEM units will provide continuous enrichment measurement for 100% of the declared gas flowing through unit header pipes, thereby improving the IAEA’s capabilities to verify operator declarations of enrichment. The OLEM concept requires an accurate determination of gas density in order to produce accurate enrichment calculations (Fig. 1). The current OLEM design assumes that this gas density is derived from a pressure transducer signal shared with the operator. The IAEA has expressed the desire for a technology that can independently and noninvasively measures gas density, in support of a next-generation OLEM design.

IAEA, Enrichment Plants, Acoustic Techniques, OLEM↗

Bat Acoustical Surveys at the National Renewable Energy Laboratory, National Wind Technology Center: July 2010-November 2010

An acoustical bat use survey was conducted at the NWTC from July 6, 2010 to November 7, 2010, using a passive acoustical method with AnaBat Systems Bat Detectors (Titley Electronics). The purpose of this survey was to obtain information about use by bats within the Project area. All data were collected from one bat detector. Bat activity was determined by the number of bat passes (number of echolocation calls recorded with = 2 chirps) per detector night. Species composition, temporal distribution (by month), and peak activity levels were analyzed. A total of 12,425 bat passes was recorded during the survey period for an index of activity of 99.40 bat passes per detector night. Of the 12,425 total bat passes, 8,772 passes could be identified to species (70.18 identified bat passes per detector night). Species identified included big brown bat, eastern red bat, fringed myotis, hoary bat, silver-haired bat, and Myotis bat group (which may include western small-footed myotis, western long-eared myotis, little brown myotis, and long-legged myotis). Most bats were detected in July (3,952 total bat passes) and August (5,058 total bat passes). The Myotis bat group was most the most frequently detected (4,373 identified bat passes). There were no peaks of activity during the monitoring period, but rather constant fluctuation. No Federally- or state-listed threatened, endangered, or candidate species or species of special concern were identified during surveys.

54 ENVIRONMENTAL SCIENCES↗

Static Strain Modelling, Calibration, and Measurements for High-Temperature Wireless SAW Resonator Operation

Static strain measurements are relevant for Integrated System Health Monitoring of civil structures, aircrafts, power plants and advanced manufacturing equipment, with implications for safety, process efficiency, and maintenance costs. Wireless strain sensing is highly desirable where the presence of wires poses significant safety concerns, increases maintenance, and thus overall costs, or where they are not feasible, such as in applications which contain moving parts. This paper presents wireless interrogation of surface acoustic wave resonators (SAWRs) fabricated on langasite (LGS) along Euler angles (0°, 138.5°, 32.9°) and aimed at the detection of static strain at hightemperature (HT, above 100°C). Both commercial HT strain gauges and finite element analysis (FEA Abaqus software) were used and compared for SAWR strain calibration from room temperature (RT) to HT. In addition, this work investigated a compromise between high temperature operation vs. sensitivity based on the thickness of ceramic adhesive used. For instance, a reduction in the adhesive thickness from about 150 μm to 135 μm, resulted in a 39% increase in sensitivity at RT. It was also observed that the sensitivity dropped up to 34% from RT to 200°C. Furthermore, wireless operation, calibration, and increase in sensitivity constitute important advances in the use of LGS SAW devices to monitor static stress in high-temperature harsh environments.

42 ENGINEERING↗

Sensitivity measurements for a 250 MHz quartz shear-horizontal surface acoustic wave biosensor under liquid viscous loading

Surface acoustic wave (SAW) devices have been used in biochemical assays due to their high sensitivity. The device sensitivity is a function of changes in the density and viscosity of the liquid. Here, we studied the effect of fluid viscosity using a 250 MHz quartz shear-horizontal (SH)-SAW biosensor by monitoring different concentrations of binary aqueous/glycerol solutions. In this study, the sensitivity of the biosensor was determined by fitting the data to models derived from perturbation theory. Measurements in water were used as the reference. For a 0% to 50% glycerol solution, an 87°–204° separation in the phase shift was observed. The slope of the plot of the phase shift vs (ηρ)0.5 was used to indicate the sensor’s sensitivity. The sensitivity for our 250 MHz quartz SH-SAW sensors was calculated to be 3.7×10−3m2sKg. The corresponding mass sensitivity was determined to be 9.25 × 105m2Kg. The limit of detection was calculated to be 36 picograms (pg), while the limit of quantification or LOQ was calculated to be 109 pg. Traditionally, liquid phase measurements have been challenging for SAW devices because liquids dampen the vibrating sensors severely. This problem has been largely solved using a transverse (shear) wave instead of the more popular longitudinal or Rayleigh waves. Liquid measurements are now possible using transverse waves, also known as shear waves, because transverse waves are only minimally attenuated by liquids. Shear-horizontal SAW sensors (SH-SAW) show great promise as label-free biosensors because of their ability to handle liquid samples. However, the viscosity of the liquid still induces loading effects and can be measured when the liquid is loaded onto the SH-SAW propagating surface (delay line). When the liquid above the delay line is perturbed by physical or chemical changes, such as binding to a receptor, it alters the propagating acoustic wave. The SH-SAW device can measure these changes in liquid properties as a change in the wave’s phase compared to the original wave. The device’s phase shift was recorded as a function of the changes in the density and viscosity of the binary glycerol solution and used to determine the sensitivity in the linear dynamic range of responses.

Materials Science↗

Improvements to pulsed phase locked loop strain monitor

A pulse phase locked loop system according to the present invention is described. A frequency generator such as a voltage controlled oscillator (VCO) generates an output signal and a reference signal having a frequency equal to that of the output signal. A transmitting gate gates the output frequency signal and this gated signal drives a transmitting transducer which transmits an acoustic wave through a material. A sample/hold samples a signal indicative of the transmitted wave which is received by a receiving transducer. Divide-by-n counters control these gating and sampling functions in response to the reference signal of the frequency generator. Specifically, the output signal is gated at a rate of F/h, wherein F is the frequency of the output signal and h is an integer; and the received signal is sampled at a delay of F/n wherein n is an integer.

Froggatt, Mark E.↗