Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Experiential findings for sustainable software ecosystems to support experimental and observational science

In the search for a sustainable approach for software ecosystems that supports experimental and observational science (EOS) across Oak Ridge National Laboratory (ORNL), we conducted a survey to understand the current and future landscape of EOS software and data. This paper describes the survey design we used to identify significant areas of interest, gaps, and potential opportunities, followed by a discussion on the obtained responses. The survey formulates questions about project demographics, technical approach, and skills required for the present and the next five years. Here, the study was conducted among 38 ORNL participants between June and July of 2021 and followed the required guidelines for human subjects training. We plan to use the collected information to help guide a vision for sustainable, community-based, and reusable scientific software ecosystems that need to adapt effectively to: (i) the evolving landscape of heterogeneous hardware in the next generation of instruments and computing (e.g. edge, distributed, accelerators), and (ii) data management requirements for data-driven science using artificial intelligence.

97 MATHEMATICS AND COMPUTING↗

On Comparing the Quality of Head and Neck Imrt Plans Delivered with Two Different Linear Accelerator Manufacturers

The purpose of this work was to determine whether 2 different types of linear accelerators manufacturers with similar MLC leaf widths deliver equivalent IMRT distributions for head and neck radiotherapy patients. In this study, plans delivered with Siemens linacs were re-optimized with an Elekta linac and vice versa. To test for significance, paired t-tests were computed to examine differences in target and normal tissue doses and monitor units. Dose distributions, dose-volume histograms, and dose to targets and normal tissues were found to be equivalent irrespective of the linac type. However, approximately 15% more monitor units were delivered when planned on the Elekta machine (p < 0.002). Both linear accelerators provide plans of comparable dosimetric quality; however, Elekta machines deliver slightly more monitor units than Siemens machines. This increase is likely due differences in geometric properties of the machine head designs, as modeled in the treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reference Cross Sections for Charged-particle Monitor Reactions

Evaluated cross sections of beam-monitor reactions are expected to become the de-facto standard for cross-section measurements that are performed over a very broad energy range in accelerators in order to produce particular radionuclides for industrial and medical applications. The requirements for such data need to be addressed in a timely manner, and therefore an IAEA coordinated research project was launched in December 2012 to establish or improve the nuclear data required to characterise charged-particle monitor reactions. An international team was assembled to recommend more accurate cross-section data over a wide range of targets and projectiles, undertaken in conjunction with a limited number of measurements and more extensive evaluations of the decay data of specific radionuclides. Least-square evaluations of monitor-reaction cross sections including uncertainty quantification have been undertaken for charged-particle beams of protons, deuterons, 3 He- and 4 He-particles. In conclusion, recommended beam monitor reaction data with their uncertainties are available at the IAEA-NDS medical portal www-nds.iaea.org/medical/monitor_reactions.html.

43 PARTICLE ACCELERATORS↗

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

Compact spectroscopy of keV to MeV X-rays from a laser wakefield accelerator

We reconstruct spectra of secondary X-rays from a tunable 250–350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarized Proton-Proton Elastic Scattering at RHIC

The Relativistic Heavy Ion Collider provides colliding polarized proton beams of 25 to 250 GeV/c momentum. With silicon strip detectors installed in Roman Pots at about 58 m on either side of the interaction point (IP) of the STAR detector, elastic scattering will be studied at a center of mass (cms) energy of 200 GeV and four momentum transfer squared range of 0.003 GeV{sup 2}/c{sup 2}<=|t|<=0.03 GeV{sup 2}/c{sup 2}, with 100% acceptance and full phi coverage. Measurements of single and double spin asymmetries will be carried out with special beam optics. An upgrade with additional Roman pots closer to the IP will increase the kinematic range to |t|<=1.5 GeV{sup 2}/c{sup 2} at sq root(s) = 500 GeV. Simulation studies of the detector acceptance for 200 GeV cms energy will be given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Drell-Yan Process with Polarized Proton Beams at J-PARC

We have proposed the construction of a spectrometer at J-PARC designed for the detection of high-mass dimuons produced in the interactions of 50 GeV primary proton beams. We have also proposed the acceleration of polarized proton beams at the J-PARC facility. Through the detections of the Drell-Yan events, a broad physics program addressing various issues in QCD is pursued. In the Drell-Yan transverse single-spin asymmetry measurement, we can explore the Sivers effect which is closely related to the orbital angular motion of partons inside the proton. Many other rich programs of spin-dependent structure function physics are carried out through the measurements of unpolarized, singly polarized, and doubly polarized Drell-Yan processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Maia Spectroscopy Detector System: Engineering for Integrated Pulse Capture, Low-Latency Scanning and Real-Time Processing

The Maia detector system is engineered for energy dispersive x-ray fluorescence spectroscopy and elemental imaging at photon rates exceeding 10{sup 7}/s, integrated scanning of samples for pixel transit times as small as 50 {micro}s and high definition images of 10{sup 8} pixels and real-time processing of detected events for spectral deconvolution and online display of pure elemental images. The system developed by CSIRO and BNL combines a planar silicon 384 detector array, application-specific integrated circuits for pulse shaping and peak detection and sampling and optical data transmission to an FPGA-based pipelined, parallel processor. This paper describes the system and the underpinning engineering solutions.

43 PARTICLE ACCELERATORS↗

Search for Strangeonia in Photoproduction using CLAS

The HyCLAS experiment at Jefferson Lab is a program to search for new and unusual mesons produced via photoproduction. The strangeonia sector is poorly known and a main component of this program is a search for new strangeonium states. The reaction {gamma}p{yields}p{phi}{eta} is an ideal channel to look for strangeonium states due to the strangeness content of both the {phi} and {eta}. The data was acquired at the JLAB CLAS facility using a 4-5.5 GeV tagged photon beam. The {phi} meson is identified via the K{sup +}K- decay. The recoil proton is observed in the CLAS spectrometer and the {eta} meson is identified through the missing mass. Also of interest is the search for strangeonia decaying to {phi}{pi}{sup 0} and {phi}{omega}. These channels are OZI suppressed for qq-bar mesons and an observation of a meson decaying to these channels would provide a strong evidence of mesons beyond qqa-bar. Preliminary results describing the data quality, kinematics and dynamics will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scaling Phenomenology in Meson Photoproduction from CLAS

In the high energy limit, perturbative QCD predicts that hard scattering amplitudes should follow simple scaling laws. For hard scattering at 90 deg., we show that experiments support this prediction even in the ''medium energy'' regime of 2.3 GeV{<=}{radical}(s){<=}2.84 GeV, as long as there are no s-channel resonances present. Our data consists of high statistics measurements for five different exclusive meson photoproduction channels (p{omega}, p{eta}, p{eta}', K{sup +{Lambda}}and K{sup +{Sigma}0}) recently obtained from CLAS at Jefferson Lab. The same power-law scaling also leads to ''saturated'' Regge trajectories at high energies. That is, at large -t and -u, Regge trajectories must approach constant negative integers. We demonstrate the application of saturated Regge phenomenology by performing a partial wave analysis fit to the {gamma}yp{yields}p{eta}'differential cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Spectra in a 15 MV LINAC

Neutron spectra were calculated inside the treatment hall of a 15 MV LINAC, calculations were carried out using Monte Carlo methods. With a Bonner sphere spectrometer with pairs of thermoluminiscent dosimeters the neutron spectrum at 100 cm from the isocenter was measured and compared with the calculated spectrum. All the spectra in the treatment hall show the presence of evaporation and knock-on neutrons; also the room-return due to the hall features is shown. In the maze the large contribution are due to epithermal and thermal neutrons. A good agreement between the calculated and measured spectrum at 100 cm was noticed, from this comparison the differences are attributed to the water content in the concrete of the hall.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Process Performance of Optima XEx Single Wafer High Energy Implanter

To meet the process requirements for well formation in future CMOS memory production, high energy implanters require more robust angle, dose, and energy control while maintaining high productivity. The Optima XEx high energy implanter meets these requirements by integrating a traditional LINAC beamline with a robust single wafer handling system. To achieve beam angle control, Optima XEx can control both the horizontal and vertical beam angles to within 0.1 degrees using advanced beam angle measurement and correction. Accurate energy calibration and energy trim functions accelerate process matching by eliminating energy calibration errors. The large volume process chamber and UDC (upstream dose control) using faraday cups outside of the process chamber precisely control implant dose regardless of any chamber pressure increase due to PR (photoresist) outgassing. An optimized RF LINAC accelerator improves reliability and enables singly charged phosphorus and boron energies up to 1200 keV and 1500 keV respectively with higher beam currents. A new single wafer endstation combined with increased beam performance leads to overall increased productivity. We report on the advanced performance of Optima XEx observed during tool installation and volume production at an advanced memory fab.

43 PARTICLE ACCELERATORS↗

950 keV X-Band Linac For Material Recognition Using Two-Fold Scintillator Detector As A Concept Of Dual-Energy X-Ray System

One of the advantages of applying X-band linear accelerator (Linac) is the compact size of the whole system. That shows us the possibility of on-site system such as the custom inspection system in an airport. As X-ray source, we have developed X-band Linac and achieved maximum X-ray energy 950 keV using the low power magnetron (250 kW) in 2 {mu}s pulse length. The whole size of the Linac system is 1x1x1 m{sup 3}. That is realized by introducing X-band system. In addition, we have designed two-fold scintillator detector in dual energy X-ray concept. Monte carlo N-particle transport (MCNP) code was used to make up sensor part of the design with two scintillators, CsI and CdWO4. The custom inspection system is composed of two equipments: 950 keV X-band Linac and two-fold scintillator and they are operated simulating real situation such as baggage check in an airport. We will show you the results of experiment which was performed with metal samples: iron and lead as targets in several conditions.

43 PARTICLE ACCELERATORS↗

Combined Photoneutron And X Ray Interrogation Of Containers For Nuclear Materials

Effective cargo inspection systems for nuclear material detection require good penetration by the interrogating radiation, generation of a sufficient number of fissions, and strong and penetrating detection signatures. Inspection systems need also to be sensitive over a wide range of cargo types and densities encountered in daily commerce. Thus they need to be effective with highly hydrogenous cargo, where neutron attenuation is a major limitation, as well as with dense metallic cargo, where x-ray penetration is low. A system that interrogates cargo with both neutrons and x-rays can, in principle, achieve high performance over the widest range of cargos. Moreover, utilizing strong prompt-neutron ({approx}3 per fission) and delayed-gamma ray ({approx}7 per fission) signatures further strengthens the detection sensitivity across all cargo types. The complementary nature of x-rays and neutrons, used as both probing radiation and detection signatures, alleviates the need to employ exceedingly strong sources, which would otherwise be required to achieve adequate performance across all cargo types, if only one type of radiation probe were employed. A system based on the above principles, employing a commercially-available 9 MV linac was developed and designed. Neutrons are produced simultaneously with x-rays by the photonuclear interaction of the x-ray beam with a suitable converter. A total neutron yield on the order of 10{sup 11} n/s is achieved with an average electron beam current of 100 {mu}A. If fissionable material is present, fissions are produced both by the high-energy x-ray beam and by the photoneutrons. Photofission and neutron fission dominate in hydrogenous and metallic cargos, respectively. Neutron-capture gamma rays provide information on the cargo composition. The prompt neutrons resulting from fission are detected by two independent detector systems: by very efficient Differential Die Away Analysis (DDAA) detectors, and by direct detection of neutrons with energies higher than 3 MeV using a recently developed fluorine-based threshold activation detector (TAD). The delayed gamma-ray signals are measured with high efficiency with the same TAD and with additional lower-cost plastic scintillators.

07 ISOTOPE AND RADIATION SOURCES↗

Electromagnetic production of hyperon resonances

The study of hyperon resonances has entered a new era of precision with advent of high-statistics photoproduction data from the CLAS detector at Jefferson Lab. These data have multi-particle final states, allowing clean identification of exclusive reactions associated with strange mesons and baryons. Examples of physics results are: evidence for isospin interference in the decay of the {Lambda}(1405) resonance; a strong suggestion of meson cloud effects in the structure of the {Sigma}(1385) resonance; data from K* photoproduction that will test the existence of the purported K{sub 0}(800) meson. Properties of other hyperon resonances will also be studied in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗