Search NASA⌕ Search

SEARCH · Search NASA

Results for “Assistant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Minilaparotomy-Assisted Transmesenteric-Transjugular Intrahepatic Portosystemic Shunt: Comparison with Conventional Transjugular Approach

PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in the conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Radiofrequency Ablation Versus Robotic-Assisted Partial Nephrectomy for the Treatment of Small Renal Cell Carcinoma

IntroductionThe authors compared the oncologic outcomes of radiofrequency ablation (RFA) with robotic-assisted partial nephrectomy (RPN) for the treatment of T1 stage renal cell carcinoma (RCC).Materials and methodsThis was a retrospective data analysis of a high-volume single tertiary centre. Patients were treated with RFA or RPN following multidisciplinary decision making. Only histologically proven RCCs were included. Baseline demographics were collected, and PADUA scores of tumour features were calculated to standardize baseline anatomy. Peri-operative complications, kidney function and oncological outcomes were compared.ResultsSixty-three cases were included in each group. Baseline renal function was poorer in RFA, and 16/63 RFA patients had tumours in single kidneys compared to 1/63 RPN cases (p < 0.001). Length of stay was shorter in RFA (1 vs. 3 days, p < 0.0001). Post-procedure renal function decline at 30 days was significantly less in RFA [(−0.8) ± 9.6 vs. (−16.1) ± 19.5 mls/min/1.73 m{sup 2}; p < 0.0001]. More minor complications were recorded in RPN (10/63 vs. 4/63, p = 0.15), but local recurrence was numerically higher in RFA (6/63 vs. 1/63, p = 0.11). Disease-free survival (DFS) was not significantly different (adjusted HR = 0.6, 95 % Cl 0.1–3.7; p = 0.60). Increasing tumour size was an independent predictor of local recurrence (adjusted HR = 1.7; 95 % Cl 1.1–2.6 per cm; p = 0.02).ConclusionsBoth RPN and RFA offer very good oncological outcomes for the treatment of T1 RCC with low peri-operative morbidity and similar oncologic outcomes. RFA demonstrated fewer peri-operative complications and better preservation of renal function, whereas RPN had an insignificantly lower local recurrence rate. RFA should be offered alongside RPN for selected cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted CBCT-Guided Needle Insertions: Preliminary Results in a Phantom Model

Aim: To compare robotic-assisted needle insertions performed under CBCT guidance to standard manual needle insertions. Materials and Methods: A homemade robotic prototype was used by two operators to perform robotic and manual needle insertions on a custom-made phantom. Both the operators had no experience with the prototype before starting the trial. The primary endpoint was accuracy (i.e., the minimal distance between the needle tip and the center of the target) between robotic and manual insertions. Secondary endpoints included total procedure time and operators’ radiation exposure. The Wilcoxon test was used. A p value less than 0.05 was considered statistically significant. Results: Thirty-three (17 manual, 16 robotic) needle insertions were performed. Mean accuracy for robotic insertion was 2.3 ± 0.9 mm (median 2.1; range 0.8–4.2) versus 2.3 ± 1 mm (median 2.1; range 0.7–4.4) for manual insertion (p = 0.84). Mean procedure time was 683 ± 57 s (median 670; range 611–849) for the robotic group versus 552 ± 40 s (median 548; range 486–621) for the manual group (p = 0.0002). Mean radiation exposure was 3.25 times less for the robotic insertion on comparison to manual insertion for the operator 1 (0.4 vs 1.3 µGy); and 4.15 times less for the operator 2 (1.9 vs 7.9 µGy). Conclusion: The tested robotic prototype showed accuracy comparable to that achieved with manual punctures coupled to a significant reduction of operators’ radiation exposure. Further, in vivo studies are necessary to confirm the efficiency of the system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted Sonic Therapy (RAST) for Noninvasive Hepatic Ablation in a Porcine Model: Mitigation of Body Wall Damage with a Modified Pulse Sequence

Purpose: Robotically assisted sonic therapy (RAST) is a nonthermal, noninvasive ablation method based on histotripsy. Prior animal studies have demonstrated the ability to create hepatic ablation zones at the focal point of an ultrasound therapy transducer; however, these treatments resulted in thermal damage to the body wall within the path of ultrasound energy delivery. The purpose of this study was to evaluate the efficacy and safety of a pulse sequence intended to mitigate prefocal body wall injury. Materials and Methods: Healthy swine (n = 6) underwent hepatic RAST (VortxRx software version 1.0.1.3, HistoSonics, Ann Arbor MI) in the right hepatic lobe. A 3.0 cm spherical ablation zone was prescribed for each. Following treatment, animals underwent MRI which was utilized for ablation zone measurement, evaluation of prefocal injury, and assessment of complications. Each animal was euthanized, underwent necropsy, and the tissue was processed for histopathologic analysis of the ablation zone and any other sites concerning for injury. Results: No prefocal injury was identified by MRI or necropsy in the body wall or tissues overlying the liver. Ablation zones demonstrated uniform cell destruction, were nearly spherical (sphericity index = 0.988), and corresponded closely to the prescribed size (3.0 × 3.1 × 3.4 cm, p = 0.70, 0.36, and 0.01, respectively). Ablation zones were associated with portal vein (n = 3, one occlusive) and hepatic vein thrombosis (n = 4, one occlusive); however, bile ducts remained patent within ablation zones (n = 2). Conclusions: Hepatic RAST performed with a modified ultrasound pulse sequence in a porcine model can mitigate prefocal body wall injuries while maintaining treatment efficacy. Further study of hepatic RAST appears warranted, particularly in tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of the target structure and composition on the ejection and transport of polymer molecules and carbon nanotubes in matrix-assisted pulsed laser evaporation

Matrix-assisted pulsed laser evaporation (MAPLE) is a prominent member of a broad and expanding class of laser-driven deposition techniques where a matrix of volatile molecules absorbs laser irradiation and provides the driving force for the ejection and transport of the material to be deposited. The mechanisms of MAPLE are investigated in coarse-grained molecular dynamic simulations focused on establishing the physical regimes and limits of the molecular transfer from targets with different structures and compositions. The systems considered in the simulations include dilute solutions of polymer molecules and individual carbon nanotubes (CNTs), as well as continuous networks of carbon nanotubes impregnated with solvent. The polymer molecules and nanotubes are found to be ejected only in the ablation regime and are incorporated into matrix-polymer droplets generated in the process of the explosive disintegration of the overheated matrix. The ejection and deposition of droplets explain the experimental observations of complex surface morphologies in films deposited by MAPLE. In simulations performed for MAPLE targets loaded with CNTs, the ejection of individual nanotubes, CNT bundles, and tangles with sizes comparable or even exceeding the laser penetration depth is observed. The ejected CNTs align along the flow direction in the matrix plume and tend to agglomerate into bundles at the initial stage of the ablation plume expansion. In a large-scale simulation performed for a target containing a network of interconnected CNT bundles, a large tangle of CNT bundles with the total mass of 50 MDa is separated from the continuous network and entrained with the matrix plume. No significant splitting and thinning of CNT bundles in the ejection process is observed in the simulations, suggesting that fragile structural elements or molecular agglomerates with complex secondary structures may be transferred and deposited to the substrate with the MAPLE technique.

Materials Science↗

MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling

Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269–1274, 2016; Arch Dis Child 81.2:172–173, 1999) atlas. The evaluation of BAA can be a tedious and time-consuming process for the radiologist. As such, several computer-assisted detection/diagnosis (CAD) methods have been proposed for automation of BAA. Classical CAD tools have traditionally relied on hard-coded algorithmic features for BAA which suffer from a variety of drawbacks. Recently, the advent and proliferation of convolutional neural networks (CNNs) has shown promise in a variety of medical imaging applications. There have been at least two published applications of using deep learning for evaluation of bone age (Med Image Anal 36:41–51, 2017; JDI 1–5, 2017). However, current implementations are limited by a combination of both architecture design and relatively small datasets. The purpose of this study is to demonstrate the benefits of a customized neural network algorithm carefully calibrated to the evaluation of bone age utilizing a relatively large institutional dataset. In doing so, this study will aim to show that advanced architectures can be successfully trained from scratch in the medical imaging domain and can generate results that outperform any existing proposed algorithm. The training data consisted of 10,289 images of different skeletal age examinations, 8909 from the hospital Picture Archiving and Communication System at our institution and 1383 from the public Digital Hand Atlas Database. The data was separated into four cohorts, one each for male and female children above the age of 8, and one each for male and female children below the age of 10. The testing set consisted of 20 radiographs of each 1-year-age cohort from 0 to 1 years to 14–15+ years, half male and half female. The testing set included left-hand radiographs done for bone age assessment, trauma evaluation without significant findings, and skeletal surveys. A 14 hidden layer-customized neural network was designed for this study. The network included several state of the art techniques including residual-style connections, inception layers, and spatial transformer layers. Data augmentation was applied to the network inputs to prevent overfitting. A linear regression output was utilized. Mean square error was used as the network loss function and mean absolute error (MAE) was utilized as the primary performance metric. MAE accuracies on the validation and test sets for young females were 0.654 and 0.561 respectively. For older females, validation and test accuracies were 0.662 and 0.497 respectively. For young males, validation and test accuracies were 0.649 and 0.585 respectively. Finally, for older males, validation and test set accuracies were 0.581 and 0.501 respectively. The female cohorts were trained for 900 epochs each and the male cohorts were trained for 600 epochs. An eightfold cross-validation set was employed for hyperparameter tuning. Test error was obtained after training on a full data set with the selected hyperparameters. Using our proposed customized neural network architecture on our large available data, we achieved an aggregate validation and test set mean absolute errors of 0.637 and 0.536 respectively. To date, this is the best published performance on utilizing deep learning for bone age assessment. Our results support our initial hypothesis that customized, purpose-built neural networks provide improved performance over networks derived from pre-trained imaging data sets. We build on that initial work by showing that the addition of state-of-the-art techniques such as residual connections and inception architecture further improves prediction accuracy. This is important because the current assumption for use of residual and/or inception architectures is that a large pre-trained network is required for successful implementation given the relatively small datasets in medical imaging. Instead we show that a small, customized architecture incorporating advanced CNN strategies can indeed be trained from scratch, yielding significant improvements in algorithm accuracy. It should be noted that for all four cohorts, testing error outperformed validation error. One reason for this is that our ground truth for our test set was obtained by averaging two pediatric radiologist reads compared to our training data for which only a single read was used. This suggests that despite relatively noisy training data, the algorithm could successfully model the variation between observers and generate estimates that are close to the expected ground truth.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave-Assisted Combustion Synthesis of ZnO:Eu Nanoparticles: Effect of Fuel Types

Nanoparticles of Europium oxide doped with Zinc oxide were synthesized via microwave-assisted combustion method. Citric acid as a simultaneous fuel and chelating agent and glycine as a fuel and mixture of these fuels were sleeted. X-Ray diffraction patterns (XRD) indicated the formation of ZnO structure with a few amount of Eu{sub 2}O{sub 3} phase. Fourier transformation infra red (FTIR) spectra reveal the increase of ZnO{sub 4} bonds with glycine content of fuels mixture. Scanning electron microscope (SEM) images showed the conversion of nanosphere to spongy-like structure with respect to change of fuel mixtures from citric to glycine. From transmission electron microscopy (TEM) nanoparticles of a mean size 30 nm are observed Green fluorescence emission of different samples was due to activation of self activated center of ZnO structure through transition of electron from Eu{sup 3+} to V{sub zn} sites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sensitive Fluorescent Determination of Cobalt by Microwave Assisted Synthesized TPTZ Functionalized Carbon Dots

Novel fluorescent carbon dots (CDs) for cobalt ions sensing were synthesized from 2,4,6-tris(2′-pyridyl)-s-triazine (TPTZ) and citric acid by microwave-assisted method in one pot. This sensor was water soluble, simple, sensitive and cheap. The size of the CDs was determined from transmission electron microscope image and was in the range of 10 nm. Under optimized experimental conditions, this luminescent system had stable response for Co (II) over a concentration range from 0.4 to 50 µM with a detection limit as low as 230 nM. The proposed method showed good sensitivity and selectivity with respect to interference ions. Finally, this system was used for Co (II) determination in tap water, river water and mineral water and B{sub 12} ampoule samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of Genetic Algorithm (GA) Assisted Partial Least Square (PLS) Analysis on Trilinear and Non-trilinear Fluorescence Data Sets to Quantify the Fluorophores in Multifluorophoric Mixtures: Improving Quantification Accuracy of Fluorimetric Estimations of Dilute Aqueous Mixtures

Excitation-emission matrix fluorescence (EEMF) and total synchronous fluorescence spectroscopy (TSFS) are the 2 fluorescence techniques that are commonly used for the analysis of multifluorophoric mixtures. These 2 fluorescence techniques are conceptually different and provide certain advantages over each other. The manual analysis of such highly correlated large volume of EEMF and TSFS towards developing a calibration model is difficult. Partial least square (PLS) analysis can analyze the large volume of EEMF and TSFS data sets by finding important factors that maximize the correlation between the spectral and concentration information for each fluorophore. However, often the application of PLS analysis on entire data sets does not provide a robust calibration model and requires application of suitable pre-processing step. The present work evaluates the application of genetic algorithm (GA) analysis prior to PLS analysis on EEMF and TSFS data sets towards improving the precision and accuracy of the calibration model. The GA algorithm essentially combines the advantages provided by stochastic methods with those provided by deterministic approaches and can find the set of EEMF and TSFS variables that perfectly correlate well with the concentration of each of the fluorophores present in the multifluorophoric mixtures. The utility of the GA assisted PLS analysis is successfully validated using (i) EEMF data sets acquired for dilute aqueous mixture of four biomolecules and (ii) TSFS data sets acquired for dilute aqueous mixtures of four carcinogenic polycyclic aromatic hydrocarbons (PAHs) mixtures. In the present work, it is shown that by using the GA it is possible to significantly improve the accuracy and precision of the PLS calibration model developed for both EEMF and TSFS data set. Hence, GA must be considered as a useful pre-processing technique while developing an EEMF and TSFS calibration model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enzyme-Assisted Extraction and Pb{sup 2+} Biosorption of Polysaccharide from Cordyceps militaris

The enzyme assisted extraction conditions of polysaccharide from Cordyceps militaris mycelia were firstly investigated by kinetics analysis and the optimal operating was found to be: extraction temperature 40 °C; solid-solvent ratio 1:20; extraction pH 4.0; cellulase concentration 2.0%. The polysaccharide extraction yield was 5.99% under these optimized conditions. Furthermore, a fundamental investigation of the biosorption of Pb{sup 2+} from aqueous solution by the C. militaris polysaccharide was performed under batch conditions. The suitable pH (5.0), polysaccharide concentration (0.20 g L{sup −1}), initial Pb{sup 2+} concentration (300 mg L{sup −1}) and contact time (40 min) were outlined to enhance Pb{sup 2+} biosorption from aqueous medium. The Langmuir isotherm model and pseudo first order kinetic model fitted well to the data of Pb{sup 2+} biosorption, suggesting the biosorption of Pb{sup 2+} onto C. militaris polysaccharide was monolayer biosorption and physical adsorption might be the rate-limiting step that controlled the adsorption process. FTIR analysis showed that the main functional groups of C. militaris polysaccharide involved in adsorption process were carbonyl, carboxyl, and hydroxyl groups.

36 MATERIALS SCIENCE↗

Optimization of Microwave-Assisted Preparation of TPA from Waste PET Using Response Surface Methodology

Terephthalic acid (TPA) was prepared from waste polyethylene terephthalate by microwave-assisted depolymerization with TOMAB as catalyst, the structure and properties of TPA were elucidated by using physico-chemical and spectroscopic methods. Single-factors experiments demonstrated that the TPA yield was affected significantly by the factors of catalyst and alkali amount, depolymerization temperature and time. The effects of variables, including catalyst and alkali amount, depolymerization temperature and time, on the TPA yield were evaluted by response surface methodology with a Box-Behnken design. The modified and verified experiments were completed after considering product performance and actual operation, the optimum parameters were determined to be TOMAB 2.7 g, 15% NaOH 260 mL, temperature 85 °C, degradation time 2.2 h. Under these conditions, the average yield of TPA in three replicated experiments is 97.53%, and this value is not significantly different from the value of 98.59% predicted by the model. These results demonstrate that this method is feasible.

36 MATERIALS SCIENCE↗

Conferring Antibacterial Properties on Sesbania Gum via Microwave-Assisted Graft Copolymerization of DADMAC

Microbial contamination, the consequences of both anthropogenic and geogenic activity, includes high health and environmental threats and may adversely affects the ecological niche. The present work is a successful attempt towards the fabrication of anti-bacterial agent by incorporation of cationic monomer, diallyldimethylammonium chloride (DADMAC) on sesbania gum through microwave assisted method. The grafted chains of poly (DADMAC) provide positive charge to sesbania gum which in turn confers antibacterial activity. The synthesized product was characterized through FTIR, SEM, TGA, DSC elemental and viscometric analysis. The inhibitory activity of the synthesized product has been evaluated in vitro against both Gram-positive (Staphylococcus aureus NCIM 2122 and Bacillus anthracis) as well as Gram-negative (Salmonella typhi NCIM 2501 and Escherichia coli NCIM 2832) bacteria through standard agar cup method. Optimum minimum inhibitory concentration for each grade of graft copolymer measured by calculating the zone of inhibition has been found at 750 µg/ml. Graphical Abstract: .

36 MATERIALS SCIENCE↗

Enhancement of Magnetization and Tailoring of Blocking Temperatures of Nano-Ni–Zn Ferrite Powder Synthesized Using Microwave-assisted Combustion Method

Single-phase nano-Ni–Zn ferrite samples in the range of 6 to 75 nm were synthesized using microwave-assisted combustion method. Enhancement of saturation magnetization (M{sub s}) was observed in comparison with previously reported results. Minor variation of (M{sub s}) due to composition change can be explained on the basis of strengthening of A–B exchange interaction due to replacement of nonmagnetic Zn ions by Ni ions. Low coercivity (H{sub c}) and retentivity (M{sub r}) indicate low loss in the samples. SQUID analysis showed that the blocking temperature (T{sub B}) of the samples can be tailored in the present work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural and Magnetic Properties of La-Substituted M-Type Hexagonal Sr–Ni Ferrites Synthesized by Ball-Milling-Assisted Ceramic Process

Sr{sub 0.5}Ni{sub 0.5}La{sub x}Fe{sub 12 − x}O{sub 19} (x = 0, 0.08, 0.16, and 0.24) hexaferrites have been synthesized by ball-milling-assisted ceramic process. The calcined samples are characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectra (FTIR), and vibrating sample magnetometry (VSM). XRD reveals that all samples consist of the main M-type hexagonal Sr ferrite phase and a low amount of rhombohedral Fe{sub 2}O{sub 3} as secondary phase, and a continuous increase of the hexagonal lattice parameters with substitution content (x). Magnetic characterization indicates that all Sr{sub 0.5}Ni{sub 0.5}La{sub x}Fe{sub 12 − x}O{sub 19} samples have a hard magnetic property. Substitution of Fe{sup 3+} ions by La{sup 3+} ions can obviously improve the specific saturation magnetization, remanence, magnetic moment, and effective anisotropy constant. Specific saturation magnetization, remanence, and the magnetic moment reach a maximum at x= 0.24 and calcination temperature of 1050 {sup ∘}C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermophysical Investigations of Ultrasonically Assisted Magnetic Nanofluids for Heat Transfer

The NiFe{sub 2}O{sub 4} magnetic nanoparticles synthesized and used to prepare stable water-based magnetic nanofluids of various concentrations by ultrasonically assisted two-step techniques. Thermophysical investigations are made on the nanofluids at different temperatures ranging from 20 to 80 °C. The measurements revealed that the thermal conductivity of nanofluids significantly enhances with an increase in the percentage of nanoparticle volume fraction. The thermal conductivity measurements showed that the maximum enhancement is 32.65% achieved at 1% nanoparticle volume fraction and at 80 °C. Specific heat of nanofluids was decreased with increasing nanoparticle volume fractions, and it augments with increasing temperature. Viscosity measurements showed that nanofluid had a Newtonian behavior at all nanoparticle volume fractions and temperatures considered. The viscosity of the nanofluid increased with increasing nanoparticle concentration and decreasing temperature. Experimental results revealed that the viscosity sensitivity to temperature variation is minor, while it is more sensitive to the variations of nanoparticle volume fraction. The density of nanofluids was increased with increasing nanoparticle volume fractions and decreased with increasing temperature. Lastly, efforts were made to provide a precise correlation to estimate the thermal conductivity, as well as other thermophysical properties at various temperatures and volume fractions of nanoparticles. The comparison between the results and the correlation results showed a good agreement.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CTAB-Assisted Synthesis of N-Doped Fe{sub 3}C Nanowires and Their Magnetic Properties

N-doped iron carbide (N-doped Fe{sub 3}C) nanomaterials have a wide range of applications. In this study, a hexadecyltrimethylammonium bromide (CTAB)-assisted two-step process was used to prepare N-doped Fe{sub 3}C nanomaterials. The effect of CTAB addition on the phase, structure, and morphologies of the products has been investigated in detail based on the characterization results of X-ray diffraction (XRD), scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS), Raman spectra (Raman), N{sub 2} adsorption–desorption, and elemental analysis. By tuning the amount of CTAB, N-doped Fe{sub 3}C nanowires were prepared. The magnetic hysteresis loops at room temperature of the N-doped Fe{sub 3}C nanomaterials show ferromagnetic characteristics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Chlorine-free, monolithic lanthanide series rare earth oxide aerogels via epoxide-assisted sol-gel method

Synthesis of chlorine-free, rare earth oxide aerogels from the lanthanide series was achieved using a modified epoxide-assisted sol-gel method. An ethanolic solution of the hydrated metal nitrate, propylene oxide, and ammonium carbonate was found to gel upon heating to 333 K. Critical point drying of the wet gel in CO 2 yielded monolithic aerogels. Most of the aerogels were amorphous as-prepared, but became nano-crystalline after calcination at 923 K in air. The aerogels had high surface areas (up to 150 m 2 /g), low densities (40–225 mg/cm 3 ), and were photoluminescent.

Rietveld refinement↗