Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Spatial Variations in Titan's Atmospheric Temperature: ALMA and Cassini Comparisons from 2012 to 2015

Submillimeter emission lines of carbon monoxide (CO) in Titan's atmosphere provide excellent probes of atmospheric temperature due to the molecule's long chemical lifetime and stable, well constrained volume mixing ratio. Here we present the analysis of 4 datasets obtained with the Atacama Large Millimeter/Submillimeter Array (ALMA) in 2012, 2013, 2014, and 2015 that contain strong CO rotational transitions. Utilizing ALMA's high spatial resolution in the 2012, 2014, and 2015 observations, we extract spectra from 3 separate regions on Titan's disk using datasets with beam sizes ranging from 0.35 ×0.28'' to 0.39 ×0.34''. Temperature profiles retrieved by the NEMESIS radiative transfer code are compared to Cassini Composite Infrared Spectrometer (CIRS) and radio occultation science results from similar latitude regions. Disk-averaged temperature profiles stay relatively constant from year to year, while small seasonal variations in atmospheric temperature are present from 2012 to 2015 in the stratosphere and mesosphere ( approx. 100-500 km) of spatially resolved regions. We measure the stratopause (320 km) to in- crease in temperature by 5 K in northern latitudes from 2012 to 2015, while temperatures rise throughout the stratosphere at lower latitudes. We observe generally cooler temperatures in the lower stratosphere ( approx. 100 km) than those obtained through Cassini radio occultation measurements, with the notable exception of warming in the northern latitudes and the absence of previous instabilities; both of these results are indicators that Titan's lower atmosphere responds to seasonal effects, particularly at higher latitudes. While retrieved temperature profiles cover a range of latitudes in these observations, deviations from CIRS nadir maps and radio occultation measurements convolved with the ALMA beam-footprint are not found to be statistically significant, and discrepancies are often found to be less than 5 K throughout the atmosphere. ALMA's excellent sensitivity in the lower stratosphere (60-300 km) provides a highly complementary dataset to contemporary CIRS and radio science observations, including altitude regions where both of those measurement sets contain large uncertainties. The demonstrated utility of CO emission lines in the submillimeter as a tracer of Titan's atmospheric temperature lays the groundwork for future studies of other molecular species -particularly those that exhibit strong polar abundance enhancements or are pressure-broadened in the lower atmosphere, as temperature profiles are found to consistently vary with latitude in all three years by up to 15 K.

Thelen, Alexander E.↗

Crossed beam energy transfer in the presence of laser speckle ponderomotive self-focusing and nonlinear sound waves

Crossed beam energy transfer, CBET, is investigated by taking into account the speckle structure of smoothed laser beams that overlap in a plasma with an inhomogeneous flow profile. Using the two-dimensional simulation code Harmony, it is shown how ponderomotive self-focusing of laser speckles in crossing beams can significantly affect the transfer of energy from one beam to the other. The role of plasma flow in speckle self-focusing is investigated and revisited, in particular its consequences in terms of redirection and increasing angular spread of the laser beams due to beam bending and plasma-induced smoothing, respectively. In close-to-sonic flow, the onset of self-focusing in the beam speckle structure occurs at considerably lower beam intensities than expected for the case without flow. CBET and speckle self-focusing can, hence, occur together when two crossed beams with equal frequency resonantly exchange energy via their ponderomotively driven density perturbations flowing with sound speed. From the simulations, it is found that consequences of ponderomotive self-focusing can be expected above an average intensity threshold scaling as $I_L~ 2 × 10^{14} W cm^{-2}(λ_0/1 μm)^{-2}(T_e/ keV)$, with an impact on the spatial and temporal coherence of the transmitted light. The density perturbations due to the ponderomotive force of the crossing beams can locally be enhanced in self-focusing speckles, partly leading to shock-like structures. These structures eventually increase the effect of plasma-induced smoothing and are at the origin of the stronger angular spread.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Atmospheric Boundary Layer Observations of Tropical Cyclones with the Imaging Wind and Rain Airborne Profiler

The Imaging Wind and Rain Arborne Profilers (IWRAP) is a dual-frequency, conically-scanning Doppler radar that measures high-resolution, dual-polarized, multi-beam C- and Ku-band reflectivity and Doppler velocity profiles of the atmospheric boundary layer (ABL) within the inner core of hurricanes.From the datasets acquired during the 2002 through 20O5 hurricane seasons as part of the ONR Coupled Boundary Layer Air-Sea Transfer (CBLAST) program and the NOAA/NESDIS Ocean Winds and Rain experiments, very high resolution radar observations of hurricanes have been acquired and made available to the CBLAST community. Of particular interest am the ABL wind fields and 3-D structures found within the inner core of hurricanes. As a result of these analysis, a limitation in the ability to retrieve the ABL wind field at very low altitudes was identified. This paper shows how this limitation has been removed and presents initial results demonstrating its new capabilities to derive the ABL wind field within the inner are of hurricanes to much lower altitudes than the ones the original system was capable of.

wind field↗

Multi-Beam Surface Lidar for Lunar and Planetary Mapping

Surface lidar techniques are now being demonstrated in low Earth orbit with a single beam of pulsed laser radiation at 1064 nm that profiles the vertical structure of Earth surface landforms along the nadir track of a spacecraft. In addition, a profiling laser altimeter, called MOLA, is operating in elliptical Martian orbit and returning surface topography data. These instruments form the basis for suggesting an improved lidar instrument that employs multiple beams for extension of sensor capabilities toward the goal of true, 3-dimensional mapping of the Moon or other similar planetary surfaces. In general the lidar waveform acquired with digitization of a laser echo can be used for laser distance measurement (i.e. range-to-the-surface) by time-of-flight measurement and for surface slope and shape measurements by examining the detailed lidar waveform. This is particularly effective when the intended target is the lunar surface or another planetary body free of any atmosphere. The width of the distorted return pulse is a first order measure of the surface incidence angle, a combination of surface slope and laser beam pointing. Assuming an independent and absolute (with respect to inertial space) measurement of laser beam pointing on the spacecraft, it is possible to derive a surface slope with-respect-to the mean planetary surface or its equipotential gravity surface. Higher-order laser pulse distortions can be interpreted in terms of the vertical relief of the surface or reflectivity variations within the area of the laser beam footprint on the surface.

Bufton, Jack L.↗

Local measurement of thermal conductivity and diffusivity

Simultaneous measurement of local thermal diffusivity and conductivity is demonstrated on a range of ceramic samples. This was accomplished by measuring the temperature field spatial profile of samples excited by an amplitude modulated continuous wave laser beam. A thin gold film is applied to the samples to ensure strong optical absorption and to establish a second boundary condition that introduces an expression containing the substrate thermal conductivity. The diffusivity and conductivity are obtained by comparing the measured phase profile of the temperature field to a continuum based model. A sensitivity analysis is used to identify the optimal film thickness for extracting the both substrate conductivity and diffusivity. Proof of principle studies were conducted on a range of samples having thermal properties that are representatives of current and advanced accident tolerant nuclear fuels. It is shown that by including the Kapitza resistance as an additional fitting parameter, the measured conductivity and diffusivity of all the samples considered agreed closely with the literature values. A distinguishing feature of this technique is that it does not require a priori knowledge of the optical spot size which greatly increases measurement reliability and reproducibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-BRB-05: Automation of the Photon Dosimetric Quality Assurance Program of a Linear Accelerator

Purpose: To develop an automated method to calculate a linear accelerator (LINAC) photon radiation field size, flatness, symmetry, output and beam quality in a single delivery for flattened (FF) and flattening-filter-free (FFF) beams using an ionization chamber array. Methods: The proposed method consists of three control points that deliver 30×30, 10×10 and 5×5cm{sup 2} fields (FF or FFF) in a step-and-shoot sequence where the number of monitor units is weighted for each field size. The IC Profiler (Sun Nuclear Inc.) with 5mm detector spacing was used for this study. The corrected counts (CCs) were calculated and the locations of the maxima and minima values of the first-order gradient determined data of each sub field. Then, all CCs for each field size are summed in order to obtain the final profiles. For each profile, the radiation field size, symmetry, flatness, output factor and beam quality were calculated. For field size calculation, a parameterized gradient method was used. For method validation, profiles were collected in the detector array both, individually and as part of the step-and-shoot plan, with 9.9cm buildup for FF and FFF beams at 90cm source-to-surface distance. The same data were collected with the device (plus buildup) placed on a movable platform to achieve a 1mm resolution. Results: The differences between the dosimetric quantities calculated from both deliveries, individually and step-and-shoot, were within 0.31±0.20% and 0.04±0.02mm. The differences between the calculated field sizes with 5mm and 1mm resolution were ±0.1mm. Conclusion: The proposed single delivery method proved to be simple and efficient in automating the photon dosimetric monthly and annual quality assurance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Reconfigurable Terahertz Metasurface Pure Phase Holograms

Terahertz (THz) radiation has many potential applications. However, comparing with the rapid development of THz sources and detectors, functional devices for THz modulation, especially the spatial modulation devices, are still insufficient. Here, we present a novel approach for generating arbitrary wavefronts of a THz beam is presented. By dynamically creating metasurface structures through illuminating a thin silicon wafer with femtosecond laser, which is spatially modulated, an array of reconfigurable subwavelength resonators is generated. The wavefront of the THz beam is then determined by forming spatial profiles of the Pancharatnam–Berry scattering phase by dynamically controlling the resonator orientation. Proof-of-concept experiments demonstrate that streaming holographic images and lenses of variable focal length can be realized in real time. The reconfigurable scheme demonstrated here is convenient and fast, and may lead to advances in a host of THz applications.

36 MATERIALS SCIENCE↗

Reirradiation of Prostate Cancer Local Failures After Previous Curative Radiation Therapy: Long-Term Outcome and Tolerance

Purpose: To evaluate the safety, feasibility, side-effect profile, and proof of concept of external beam radiation therapy (EBRT) with or without a brachytherapy (BT) boost for salvage of exclusive local failure after primary EBRT for prostate cancer. Methods and Materials: Fourteen patients with presumed exclusive local recurrence after primary EBRT with or without BT were considered eligible for reirradiation. The median normalized total dose in 2-Gy fractions (NTD{sub 2Gy}, α/β ratio = 1.5 Gy) was 74 Gy (range, 66-98.4 Gy) at first irradiation. Median time between the first irradiation and the reirradiation was 6.1 years (range, 4.7-10.2 years). Results: Between 2003 and 2008 salvage treatment was delivered with a median NTD{sub 2Gy} of 85.1 Gy (range, 70-93.4) to the prostate with EBRT with (n=10) or without (n=4) BT. Androgen deprivation was given to 12 patients (median time of 12 months). No grade ≥3 toxicity was observed during and within 6 weeks after RT. After a median follow-up of 94 months (range, 48-172 months) after salvage RT, 5-year grade ≥3 genitourinary and gastrointestinal toxicity-free survival figures were 77.9% ± 11.3% and 57.1% ± 13.2%, respectively. Four patients presented with combined grade 4 genitourinary/gastrointestinal toxicity. The 5-year biochemical relapse-free, local relapse-free, distant metastasis-free, and cancer-specific survival rates were 35.7% ± 12.8%, 50.0% ± 13.4%, 85.7% ± 9.4%, and 100%, respectively. Conclusion: Salvage whole-gland reirradiation for patients with a suspicion of exclusive local recurrence after initial RT may be associated with a high rate of severe radiation-induced side effects and poor long-term biochemical and local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shock loading characteristics of Zr and Ti metals using dual beam velocimeter

The characteristics of titanium and zirconium metal foils under shock loading have been studied up to 16 GPa and 12 GPa pressure, respectively, using portable electric gun setup as projectile launcher. In these experiments, the capabilities of a single Fabry-Perot velocimeter have been enhanced by implementing it in dual beam mode to record the two velocity profiles on a single streak camera. The measured equation of state data for both the metals have been found to be well in agreement with the reported Hugoniot, within experimental accuracies. A phase transition from α to ω phase has been detected near to 11.4 GPa for titanium and 8.2 GPa for zirconium in the rising part of target-glass interface velocity profile.

36 MATERIALS SCIENCE↗

Static deflection analysis of non prismatic multilayer p-NEMS cantilevers under electrical load

Deflection of Euler-Bernoulli non prismatic multilayer piezoelectric nano electromechanical (p-NEMS) cantilever beams have been studied theoretically for various profiles of p-NEMS cantilevers by applying the electrical load. This problem has been answered by applying the boundary conditions derived by simple polynomials. This method is applied for various profiles like rectangular and trapezoidal by varying the thickness of the piezoelectric layer as well as the material. The obtained results provide the better deflection for trapezoidal profile with ZnO piezo electric layer of suitable nano cantilevers for nano scale applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The neutron camera upgrade for MAST Upgrade

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard γ-rays sources and a 252 Cf source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. Finally, the energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.

47 OTHER INSTRUMENTATION↗

Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM

FIDASIM is a code that models signals produced by charge-exchange reactions between neutrals and ions (both fast and thermal) in magnetically confined plasmas. With the ion distribution function as input, the code predicts the efflux to a neutral particle analyzer diagnostic and the photon radiance of Balmer-alpha light to a fast-ion D α diagnostic, in addition to many other related quantities. A new, parallelized version of the Monte Carlo code FIDASIM has been developed in Fortran90 that is substantially faster than the original interactive data language version. Modified algorithms include more accurate treatments of the time dependent collisional-radiative equations that describe neutral energy levels, of the cloud of ‘halo’ neutrals that surround the injected neutral beam, and of finite Larmor radius effects. Enhanced physics capabilities include modelling ‘passive’ signals from cold edge neutrals, the ability to treat general three-dimensional magnetic confinement configurations, and calculations of diagnostic-specific weight functions that enable tomographic reconstructions of the fast-ion distribution function. Neutral beam attenuation, beam emission, and fast-ion birth profiles are also modelled. Finally, the new algorithms have been successfully validated against experimental data and new features have been tested through benchmarks between two independently developed versions of the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An examination of the performance of molecular dynamics force fields: Silicon and silicon dioxide reactive ion etching

Classical molecular dynamics (MD) simulations of plasma-surface interactions were performed of physical sputtering and reactive ion etching (RIE), with predictions based on several force fields. In this paper, we focus mainly on SiO 2 but include some results for Si substrates as well. Here, we compare predictions from these MD simulations to experimental studies of SiO 2 physical sputtering (by Ar + ions), RIE of Si, and RIE of SiO 2 (both using F atoms and Ar + ions). MD results using different published force fields are compared to reported yields from published vacuum beam experiments. The near-surface depth profiles predicted using different force fields are compared. One motivation for the present study is to document the nature and magnitude of differences in the predictions for selected systems and conditions of practical interest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-C-BRC-07: Parametrized GPU Accelerated Electron Monte Carlo Second Check

Purpose: I am presenting a parameterized 3D GPU accelerated electron Monte Carlo second check program. Method: I wrote the 3D grid dose calculation algorithm in CUDA and utilized an NVIDIA GeForce GTX 780 Ti to run all of the calculations. The electron path beyond the distal end of the cone is governed by four parameters: the amplitude of scattering (AMP), the mean and width of a Gaussian energy distribution (E and α), and the percentage of photons. In my code, I adjusted all parameters until the calculated PDD and profile fit the measured 10×10 open beam data within 1%/1mm. I then wrote a user interface for reading the DICOM treatment plan and images in Python. In order to verify the algorithm, I calculated 3D dose distributions on a variety of phantoms and geometries, and compared them with the Eclipse eMC calculations. I also calculated several patient specific dose distributions, including a nose and an ear. Finally, I compared my algorithm’s computation times to Eclipse’s. Results: The calculated MU for all of the investigated geometries agree with the TPS within the TG-114 action level of 5%. The MU for the nose was < 0.5 % different while the MU for the ear at 105 SSD was ∼2 %. Calculation times for a 12MeV 10×10 open beam ranged from 1 second for a 2.5 mm grid resolution with ∼15 million particles to 33 seconds on a 1 mm grid with ∼460 million particles. Eclipse calculation runtimes distributed over 10 FAS workers were 9 seconds to 15 minutes respectively. Conclusion: The GPU accelerated second check allows quick MU verification while accounting for patient specific geometry and heterogeneity.

60 APPLIED LIFE SCIENCES↗

TOWARD PRECISION BLACK HOLE MASSES WITH ALMA: NGC 1332 AS A CASE STUDY IN MOLECULAR DISK DYNAMICS

We present first results from a program of Atacama Large Millimeter/submillimeter Array (ALMA) CO(2–1) observations of circumnuclear gas disks in early-type galaxies. The program was designed with the goal of detecting gas within the gravitational sphere of influence of the central black holes (BHs). In NGC 1332, the 0.″3-resolution ALMA data reveal CO emission from the highly inclined (i≈83{sup ∘}) circumnuclear disk, spatially coincident with the dust disk seen in Hubble Space Telescope images. The disk exhibits a central upturn in maximum line-of-sight velocity, reaching ±500 km s{sup −1} relative to the systemic velocity, consistent with the expected signature of rapid rotation around a supermassive BH. Rotational broadening and beam smearing produce complex and asymmetric line profiles near the disk center. We constructed dynamical models for the rotating disk and fitted the modeled CO line profiles directly to the ALMA data cube. Degeneracy between rotation and turbulent velocity dispersion in the inner disk precludes the derivation of strong constraints on the BH mass, but model fits allowing for a plausible range in the magnitude of the turbulent dispersion imply a central mass in the range of ∼(4–8) × 10{sup 8} M{sub ⊙}. We argue that gas-kinematic observations resolving the BH’s projected radius of influence along the disk’s minor axis will have the capability to yield BH mass measurements that are largely insensitive to systematic uncertainties in turbulence or in the stellar mass profile. For highly inclined disks, this is a much more stringent requirement than the usual sphere-of-influence criterion.

79 ASTRONOMY AND ASTROPHYSICS↗

The CU 2-D-MAX-DOAS instrument – Part 1: Retrieval of 3-D distributions of NO 2 and azimuth-dependent OVOC ratios

Here, we present an innovative instrument telescope and describe a retrieval method to probe three-dimensional (3-D) distributions of atmospheric trace gases that are relevant to air pollution and tropospheric chemistry. The University of Colorado (CU) two-dimensional (2-D) multi-axis differential optical absorption spectroscopy (CU 2-D-MAX-DOAS) instrument measures nitrogen dioxide (NO 2 ), formaldehyde (HCHO), glyoxal (CHOCHO), oxygen dimer (O 2 –O 2 , or O 4 ), and water vapor (H 2 O); nitrous acid (HONO), bromine monoxide (BrO), and iodine monoxide (IO) are among other gases that can in principle be measured. Information about aerosols is derived through coupling with a radiative transfer model (RTM). The 2-D telescope has three modes of operation: mode 1 measures solar scattered photons from any pair of elevation angle (–20° < EA < +90° or zenith; zero is to the horizon) and azimuth angle (–180° < AA < +180°; zero being north); mode 2 measures any set of azimuth angles (AAs) at constant elevation angle (EA) (almucantar scans); and mode 3 tracks the direct solar beam via a separate view port. Vertical profiles of trace gases are measured and used to estimate mixing layer height (MLH). Horizontal distributions are then derived using MLH and parameterization of RTM (Sinreich et al., 2013). NO 2 is evaluated at different wavelengths (350, 450, and 560 nm), exploiting the fact that the effective path length varies systematically with wavelength. The area probed is constrained by O 4 observations at nearby wavelengths and has a diurnal mean effective radius of 7.0 to 25 km around the instrument location; i.e., up to 1960 km 2 can be sampled with high time resolution. The instrument was deployed as part of the Multi-Axis DOAS Comparison campaign for Aerosols and Trace gases (MAD-CAT) in Mainz, Germany, from 7 June to 6 July 2013. We present first measurements (modes 1 and 2 only) and describe a four-step retrieval to derive (a) boundary layer vertical profiles and MLH of NO 2 ; (b) near-surface horizontal distributions of NO 2 ; (c) range-resolved NO 2 horizontal distribution measurements using an "onion-peeling" approach; and (d) the ratios HCHO to NO 2 ( R FN ), CHOCHO to NO 2 ( R GN ), and CHOCHO to HCHO ( R GF ) at 14 pre-set azimuth angles distributed over a 360° view. Three-dimensional distribution measurements with 2-D-MAX-DOAS provide an innovative, regional perspective of trace gases as well as their spatial and temporal concentration gradients, and they maximize information to compare near-surface observations with atmospheric models and satellites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of the radial distribution of molecular gas and non-thermal radio continuum in spiral disks

The present study includes 65 spiral galaxies selected from the Five College Radio Astronomy Observatory (FCRAO) Extragalactic CO Survey for which the major axis distributions of CO emission and 1.49 GHz radio continuum emission are well determined. The radial distribution of the CO emission has been measured with the FCRAO at positions along the major axis that are spaced by one half power beam width (HPBW) (45 seconds). The radial profile of the 1.49 GHz radio continuum emission was constructed by determining the radio emission at the location of the CO measurements from the 1.49 GHz maps of Condon (1987). Large, greater than a factor of ten, radially decreasing gradients in the star formation efficiency are observed for a small percentage, approx. 10 percent, of the spirals in this sample. The majority of spirals, however, are associated with small gradients in the star formation efficiency that do not systematically increase or decrease with radius. That the star formation efficiency does not systematically decrease with radius tends to argue against a global dynamical mechanism, such as a spiral density wave, for being the dominant mechanism triggering disk star formation for the majority of spirals in this sample. The results tend to support the view that the star formation in spiral disks is dominated by a local process that depends more on the molecular cloud properties than the dynamical structure of a galaxy.

Devereux, Nicholas A.↗