Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Higher certainty of the laser-induced damage threshold test with a redistributing data treatment

As a consequence of its statistical nature, the measurement of the laser-induced damage threshold holds always risks to over- or underestimate the real threshold value. As one of the established measurement procedures, the results of S-on-1 (and 1-on-1) tests outlined in the corresponding ISO standard 21 254 depend on the amount of data points and their distribution over the fluence scale. With the limited space on a test sample as well as the requirements on test site separation and beam sizes, the amount of data from one test is restricted. This paper reports on a way to treat damage test data in order to reduce the statistical error and therefore measurement uncertainty. Three simple assumptions allow for the assignment of one data point to multiple data bins and therefore virtually increase the available data base.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Longitudinal-Phase-Space Manipulation for Efficient Beam-Driven Structure Wakefield Acceleration

Collinear beam-driven structure wakefield acceleration (SWFA) is an advanced acceleration technique that could support the compact generation of high-energy beams for future multi-user x-ray free-electron-laser facilities*. Producing an ideal shaped drive beam through phase space manipulation is crucial for an efficient SWFA. Controlling the final longitudinal-phase space of the drive beam necessitate staged beam manipulations during acceleration. This paper describes the preliminary design of an accelerator beamline capable of producing drive beam with tailored current distribution and longitudinal-phase-space correlation. The proposed design is based on simple analytical models combined in a 1-D longitudinal beam-dynamics simulation tracking program supporting forward and backward (time reversal) tracking.

43 PARTICLE ACCELERATORS↗

Quasi-periodic structures in the large-scale galaxy distribution and three-dimensional Voronoi tessellation

It has been suggested that the void and wall structure associated with the large-scale galaxy distribution might be qualitatively, or perhaps even physically, modeled by a Voronoi tessellation, and that such structure might account for the surprisingly regular, sharp peaks in the galaxy redshift distributions obtained from 'pencil beam' surveys. Taking cell wall crossings by random line segments to correspond to such redshift peaks, an exact expression is derived for the distribution of spacings of these intersections in a three-dimensional Voronoi tessellation. This result verifies that the spacings are nonrandom and quasi-periodic, qualitatively resembling the observed pattern, even though the cell wall structure is generated from randomly placed seeds. Finally, moments of the spacing distribution are used to show that apparently periodic samples, similar to those recently reported, represent only one to two sigma fluctuations in a Voronoi tesselation.

Ikeuchi, Satoru↗

LONGITUDINAL-PHASE-SPACE MANIPULATION FOR EFFICIENT BEAM-DRIVEN STRUCTURE WAKEFIELD ACCELERATION∗

Collinear beam-driven structure wakefield acceleration (SWFA) is an advanced acceleration technique that could support the compact generation of high-energy beams for future multi-user x-ray free-electron-laser facilities [1]. Producing an ideal shaped drive beam through phase space manipulation is crucial for an efficient SWFA. Controlling the final longitudinal-phase space of the drive beam necessitate staged beam manipulations during acceleration. This paper describes the preliminary design of an accelerator beamline capable of producing drive beam with tailored current distribution and longitudinal-phase-space correlation. The proposed design is based on simple analytical models combined in a 1-D longitudinal beam-dynamics simulation tracking program supporting forward and backward (time reversal) tracking.

wakefield↗

Influence of lithium coating on the optics of Doppler backscatter system

This paper presents the first investigation of the effect of lithium coating on the optics of Doppler backscattering. A liquid lithium limiter has been applied in the Experimental Advanced Superconducting Tokamak (EAST), and a Doppler backscattering has been installed in the EAST. A parabolic mirror and a flat mirror located in the vacuum vessel are polluted by lithium. An identical optical system of the Doppler backscattering is set up in laboratory. The power distributions of the emission beam after the two mirrors with and without lithium coating (cleaned before and after), are measured at three different distances under four incident frequencies. The results demonstrate that the influence of the lithium coating on the power distributions are very slight, and the Doppler backscattering can work normally under the dosage of lithium during the 2014 EAST campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A pepper-pot emittance meter for low-energy heavy-ion beams

A novel emittance meter has been developed to measure the four-dimensional, transverse phase-space distribution of a low-energy ion beam using the pepper-pot technique. A characteristic feature of this instrument is that the pepper-pot plate, which has a linear array of holes in the vertical direction, is scanned horizontally through the ion beam. This has the advantage that the emittance can also be measured at locations along the beam line where the beam has a large horizontal divergence. A set of multi-channel plates, scintillation screen, and ccd camera is used as a position-sensitive ion detector allowing a large range of beam intensities that can be handled. This paper describes the design, construction, and operation of the instrument as well as the data analysis used to reconstruct the four-dimensional phase-space distribution of an ion beam. Measurements on a 15 keV He{sup +} beam are used as an example.

43 PARTICLE ACCELERATORS↗

Oblique incidence for broad monoenergetic proton beams

Purpose: The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial Gaussian angular distribution. Methods: The Bortfeld model of depth dose in a broad normally incident proton beam has been extended to the case of oblique incidence. This extension uses an empirically determined Gaussian parameter {sigma}{sub x} which (roughly) characterizes the off-axis dose of a proton pencil beam. As with Bortfeld's work, the modeling is done in terms of parabolic cylinder functions. To obtain the depth dose for an initial angular distribution, the result is integrated over the angle of incidence, weighted by a Gaussian probability function. The predictions of the theory have been compared to MCNPX Monte Carlo calculations for four phantom materials (water, bone, aluminum, and copper) and for initial proton energies of 50, 100, 150, 200, and 250 MeV. Results: Comparisons of the depth dose predicted by this theory with Monte Carlo calculations have established that with very good accuracy, {sigma}{sub x} can be taken to be independent both of the depth and of the angle of incidence. As a function of initial proton range or of initial proton energy, {sigma}{sub x} has been found to obey a power law to very high accuracy. Good fits to Monte Carlo calculations have also been found for an initial Gaussian angular distribution. Conclusions: This investigation is the first step in the accurate modeling of a proton pencil beam with initial Gaussian angular distribution. It provides the longitudinal factor, with its Bragg peak buildup and sharp distal falloff. A transverse factor must still be incorporated into this theory and this will give the lateral penumbra of a collimated proton beam. Also, it will be necessary to model the dose of product particles from nuclear interactions of the proton beam. With the accurate modeling of a pencil beam, it will be possible to accurately take into account the effect of localized tissue inhomogeneities.

60 APPLIED LIFE SCIENCES↗

Video-rate terahertz electric-field vector imaging

We present an experimental setup to dramatically reduce a measurement time for obtaining spatial distributions of terahertz electric-field (E-field) vectors. The method utilizes the electro-optic sampling, and we use a charge-coupled device to detect a spatial distribution of the probe beam polarization rotation by the E-field-induced Pockels effect in a 〈110〉-oriented ZnTe crystal. A quick rotation of the ZnTe crystal allows analyzing the terahertz E-field direction at each image position, and the terahertz E-field vector mapping at a fixed position of an optical delay line is achieved within 21 ms. Video-rate mapping of terahertz E-field vectors is likely to be useful for achieving real-time sensing of terahertz vector beams, vector vortices, and surface topography. The method is also useful for a fast polarization analysis of terahertz beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SUBMILLIMETER H{sub 2}O MASER IN CIRCINUS GALAXY-A NEW PROBE FOR THE CIRCUMNUCLEAR REGION OF ACTIVE GALACTIC NUCLEI

We present the first detection of extragalactic submillimeter H{sub 2}O maser in the 321 GHz transition toward the center of Circinus galaxy, the nearby Type 2 Seyfert using the Atacama Large Millimeter/Submillimeter Array. We find that Doppler features of the detected 321 GHz H{sub 2}O maser straddle the systemic velocity of the galaxy as seen in the spectrum of the known 22 GHz H{sub 2}O maser in the galaxy. By comparing the velocities of the maser features in both transitions, it can be deduced that the 321 GHz maser occurs in a region similar to that of the 22 GHz maser, where the sub-parsec-scale distribution of the 22 GHz maser was revealed by earlier very long baseline interferometry observations. The detected maser features remain unresolved at the synthesized beam of {approx}0.''66 ({approx}15 pc) and coincide with the 321 GHz continuum peak within small uncertainties. We also present a tentative detection of the highest velocity feature (redshifts up to {approx}635 km s{sup -1}) in the galaxy. If this high-velocity feature arises from a Keplerian rotating disk well established in this galaxy, it is located at a radius of {approx}0.018 pc ({approx}1.2 Multiplication-Sign 10{sup 5} Schwarzschild radii), which might probe molecular material closest to the central engine.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstruction of Six-Dimensional Phase Space

A phase space is a mathematical representation of all possible physical states of a system. Particle beams at Fermilab exist within a six-dimensional (6D) phase space defined by three positional components, (x, y, z) and three momentum components, (px, py, pz). To reconstruct this space implies taking measurement data from detectors and mapping out particle behavior using computational methods. The beam detectors, however, are only able to detect spatial distribution among the events of the beam, therefore being limited to positional data. Also, due to the vast number of events in a particle beam, it is extremely difficult to analyze and differentiate every single one’s behavior. However, with Machine Learning (ML), which can distinguish between patterns and map out particle behavior more efficiently. We first used the particle beam software, G4beamline, to simulate a 10,000-event muon beam, adjusting parameters such as initial momentum magnitude (p¬0) and virtual detector position. Using ten virtual detectors, we analyzed p0 values such that minimum 9,990 events were analyzed by every detector. We then input the data from these beam simulations to a C++ program, that randomly selects 100 events, and creates a 2D histogram based on spatial distribution, detector position, and event intensity. This process is repeated 100 times to create 100 histograms per p0 value. These images were then input to a modified ResNet18 Convolutional Neural Network (CNN) for training, and to predict p0 from some unseen set of histograms. The model was accurate when trained on momentum increments of 5 MeV/c and provided with denser training samples around highly variable test values. These results displayed machine learning being able to accurately predict p0 from being trained on different particle behaviors.

Shirlee, Jermain [Fermilab]↗

Flow velocity measurement with the nonlinear acoustic wave scattering

A problem of noninvasive measurement of liquid flow velocity arises in many practical applications. To this end the most often approach is the use of the linear Doppler technique. The Doppler frequency shift of signal scattered from the inhomogeneities distributed in a liquid relatively to the emitted frequency is proportional to the sound frequency and velocities of inhomogeneities. In the case of very slow flow one needs to use very high frequency sound. This approach fails in media with strong sound attenuation because acoustic wave attenuation increases with frequency and there is limit in increasing sound intensity, i.e. the cavitation threshold. Another approach which is considered in this paper is based on the method using the difference frequency Doppler Effect for flows with bubbles. This method is based on simultaneous action of two high-frequency primary acoustic waves with closed frequencies on bubbles and registration of the scattered by bubbles acoustic field at the difference frequency. The use of this method is interesting since the scattered difference frequency wave has much lower attenuation in a liquid. The theoretical consideration of the method is given in the paper. The experimental examples confirming the theoretical equations, as well as the ability of the method to be applied in medical diagnostics and in technical applications on measurement of flow velocities in liquids with strong sound attenuation is described. It is shown that the Doppler spectrum form depends on bubble concentration velocity distribution in the primary acoustic beams crossing zone that allows one to measure the flow velocity distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Residual-gas-ionization beam profile monitors in RHIC

Four ionization profile monitors (IPMs) are in RHIC to measure vertical and horizontal beam profiles in the two rings. These work by measuring the distribution of electrons produced by beam ionization of residual gas. During the last two years both the collection accuracy and signal/noise ratio have been improved. An electron source is mounted across the beam pipe from the collector to monitor microchannel plate (MCP) aging and the signal electrons are gated to reduce MCP aging and to allow charge replenishment between single-turn measurements. Software changes permit simultaneous measurements of any number of individual bunches in the ring. This has been used to measure emittance growth rates on six bunches of varying intensities in a single store. Also the software supports FFT analysis of turn-by-turn profiles of a single bunch at injection to detect dipole and quadrupole oscillations.

43 PARTICLE ACCELERATORS↗

Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94.62%, respectively, for the bolus ECT plans and 89.2% and 95.1%, respectively, for the mixed beam plans. For all regions, pass rates for the parotid and CW plans were 98.8% and 97.3%, respectively, for the bolus ECT plans and 97.5% and 95.9%, respectively, for the mixed beam plans. For the IMXT component of the mixed beam plans, pass rates for the parotid and CW plans were 93.7% and 95.8%. Conclusions: Bolus ECT and mixed beam therapy dose delivery to the phantom were more accurate than IMXT delivery, adding confidence to the use of planning, fabrication, and delivery for bolus ECT tools either alone or as part of mixed beam therapy. The methodology reported in this work could serve as a basis for future standardization of the commissioning of bolus ECT or mixed beam therapy. When applying this technology to patients, it is recommended that an electron dose algorithm more accurate than the pencil beam algorithm, e.g., a Monte Carlo algorithm or analytical transport such as the pencil beam redefinition algorithm, be used for planning to ensure the desired accuracy.

60 APPLIED LIFE SCIENCES↗

THz Radar Observations of Hydrometeors in a Spray Chamber

Abstract A THz radar, with its wide bandwidth, is capable of high‐resolution imaging down to the centimeter scale. In this study, a THz radar is applied to detect hydrometeors generated in a spray chamber. The observed backscattering signals show fluctuations at centimeter scales, indicating various hydrometeor distribution patterns along the radar beam. A co‐located High‐Speed Imaging (HSI) sensor is used to measure the Drop Size Distributions (DSD) in the spray chamber. The radar sampling beam is well aligned with the HSI probes, allowing an objective comparison between the remote sensing and in situ observations. In this study, the observed radar power is compared with the power estimated from the HSI measurements. Results show great consistency, with power difference smaller than 0.5 dB. This study demonstrates the feasibility and great potential of using a THz radar for ultra‐high‐resolution observations of clouds in a laboratory facility, and in the real atmosphere.

54 ENVIRONMENTAL SCIENCES↗

A Distributed Simulation-to-Flight Framework to Support Investigating Trust/Trustworthiness in Multi-Agent Systems

As autonomous systems continue to grow both in use and complexity, the necessity for robust and extensible simulation-to-flight frameworks is paramount for establishing an effective architecture for autonomous systems. Hardware test flights are time-consuming and cost prohibitive during early system design and development. Simulation environments can be useful tools to accelerate algorithm development and testing. However, transitions from simulation to flight (sim-to-flight) can be challenging, unless systems are designed with this transition in mind and with the necessary capabilities built into the architecture and framework. One of the objectives of Autonomy Teaming and TRAjectories for Complex Trusted Operational Reliability (ATTRACTOR) was to design and develop a distributed mixed-reality simulation environment to begin establishing a basis for certification of autonomous systems via research into trust and trustworthiness. ATTRACTOR’s objective was to construct computational concepts of trustworthiness and justifiable trust in multi-agent autonomous teams, to inform future certification of safety-critical and time-critical autonomous systems in aviation. In this paper, we present an autonomous systems architecture and development framework paired with a persistent distributed modeling and simulation (ModSim) environment for test and evaluation of autonomous systems. They were designed under ATTRACTOR in order to measure and establish trustworthiness and trust in single-and multi-agent human-machine systems whether these machines are fixed-wing general aviation, rotary-wing Unmanned Aerial Vehicles (UAVs), ground rovers, or even spacecraft. The Autonomous Entity Operational Network (AEON) framework enables autonomous system development with an easily extensible collection of libraries and plug-n-play nodes facilitated by the Data Distribution Service (DDS) communication protocol standard. The Baseline Environment for Autonomous Modeling (BEAM) simulation environment is a distributed mixed-reality Unity™-based environment built around the same DDS communication paradigm allowing for easy integration with AEON-based autonomous applications, enabling sim-to-flight with minimal configuration changes. Using AEON and BEAM, source code that runs in simulation ports directly to hardware and has successfully flown in the National Airspace System (NAS) at NASA LaRC many times over the lifetime of ATTRACTOR.

Benjamin N Kelley↗

Diagnostic beam absorber in Mu2e beam line

Star density, hadron flux, and residual dose distributions are calculated around the {mu}2e diagnostic beam absorber. Corresponding surface and ground water activation, and air activation are presented as well.

43 PARTICLE ACCELERATORS↗

Optical diffraction radiation from a beam off a circular target

The use of optical diffraction radiation (ODR) as a diagnostic tool has increased in recent years. The potential of this technique has been demonstrated in several experiments at KEK [1], APS [2], FLASH [3] and possibly other facilities. These experiments were performed in extraction beam lines of lepton machines. However this technique can also be applied to high energy hadron beams. In this report we consider the ODR produced by such beams with the target as a round hole and apply the results to the Tevatron. This radiation is produced when a beam passes in the vicinity of a conducting target. The electro-magnetic fields due to the beam induce currents on the target and as the beam propagates, the currents change in time producing radiation both in the direction of beam propagation and along the direction of specular reflection from the target. This latter radiation, also termed backward diffraction radiation (BDR), is more useful for diagnostics since it can be directed out at the same longitudinal location as the target. This radiation is different from optical transition radiation (OTR) in which the beam passes through a metal target. Transition radiation is not suitable for continuous monitoring of a beam in a collider due to the beam energy loss and emittance growth and the fact that the target may be damaged. However the techniques for analyzing ODR are similar in many respects to those for OTR. Measurements of the radiation intensity either in the near field or far-field have been used to determine beam positions and sizes. For example, the beam size and beam position of a 1.28 GeV electron beam were measured in an extraction beam line at KEK [1] using the far-field angular distribution of the radiation. The near-field image was used to monitor the relative beam size of a 7 GeV electron beam in the extraction line at APS [2]. In principle, measurements of the beam divergence are also possible using the interference of ODR between two targets, as has been done with OTR. This paper is motivated by the desire to use this technique in colliders, especially for the LHC and possibly for future colliders envisaged such as the muon collider. A brief report on these prospects was presented earlier [4]. If the technique yields beam measurements with sufficient accuracy and reliability then the non-invasive nature would allow continuous monitoring during the length of a luminosity run. This would be valuable if the beam can be imaged close to the interaction points. Synchrotron radiation is already used as a non-invasive diagnostic tool in the Tevatron and will also be used in the LHC. The principal advantage of ODR is that it can be generated in a straight section and therefore used for imaging in an experimental insertion. The disadvantage is that the ODR flux is less copious than synchrotron radiation (OSR) and imaging will take longer than with OSR. In Section 2 we briefly discuss the parameters of different hadron colliders. In Section 3 we derive the basic results for the angular differential spectrum of ODR from a round hole due to a bunch. We apply these results in Section 4 to find the sensitivity of the spectrum to beam size and offset changes. In Section 5, we calculate the expected photon yield from a bunch per turn as a function of frequency and we use this to find the frequency range where a sufficiently strong ODR signal can be obtained. In Section 6 we do a brief comparison of the ODR spectrum with the OTR spectrum. We briefly list in Section 7 the experimental issues associated with measuring ODR when two beams are present. We end with our conclusions in Section 8. We will use CGS units throughout.

43 PARTICLE ACCELERATORS↗