Search NASA⌕ Search

SEARCH · Search NASA

Results for “Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Small Commercial Building Re-tuning: A Primer

To help building owners and managers address issues related to energy-efficient operation of small buildings, DOE has developed a Small Building Re-tuning training curriculum. This "primer" provides additional background information to understand some of the concepts presented in the Small Building Re-tuning training. The intent is that those who are less familiar with the building energy concepts will review this material before taking the building re-tuning training class.

building energy↗

Analysis for Building Envelopes and Mechanical Systems Using 2012 CBECS Data

This report describes the aggregation and mapping of certain building characteristics data available in the most recent Commercial Building Energy Consumption Survey (CBECS) (DOE EIA 2012) to describe most typical building construction practices. This report provides summary data for potential use in the support of modifications to the Pacific Northwest National Laboratory’s commercial building prototypes used for building energy code analysis. Specifically, this report outlines findings and most typical design choices for certain building envelope and heating, ventilating, and air-conditioning (HVAC) system choices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building heights and urban canopy parameters for urban modeling

GLObal Building heights for Urban Studies (UT-GLOBUS) is a random forest model based framework that provides a level-of-detail-1 (LoD-1) building height dataset. The primary objective of UT-GLOBUS is not to precisely predict the height and footprint of individual buildings, but rather to offer a functional framework for generating building level information using open-source datasets for modeling applications. Specifically, UT-GLOBUS is tailored to meet the requirements of deriving urban canopy parameters (UCPs) for the multi-layer model within the Weather Research and Forecasting (WRF) model and building heights for the SOLWEIG and SUEWS model. Building-level data is accessible in vector file format (GeoPackage: .gpkg), which can be converted into raster file format (geoTIFF). The vector files employ the Universal Transverse Mercator (UTM) projection. The vector files are compatible with GIS platforms like QGIS and ArcGIS, and can be imported for analysis using programming languages such as Python. We are also providing UCPs required by the multi-layer urban model in the urban WRF in binary file format. Additionally, we provide the urban fractions calculated using ESA world cover dataset (https://esa-worldcover.org/en) for WRF model in binary file format. These binary files can be directly incorporated into the WRF pre-processing system (WPS).

54 ENVIRONMENTAL SCIENCES↗

Final Technical Report for the Net-Zero Energy Commercial Buildings Consortium

The Commercial Buildings Consortium (CBC) was established in 2009, under the chairmanship of the National Association of State Energy Officials (NASEO), as a supporting organization to the Commercial Buildings Initiative (CBI). The CBI was created by Congress through the Energy Independence and Security Act of 2007 (EISA) and launched by the Department of Energy (DOE) in 2008 with the goal to “develop and disseminate technologies, practices, and policies for establishment of zero net energy commercial buildings.”. The impact of the CBC since 2009 has been multifold, resulting in increased collaboration, increased innovation, and increased demonstration and deployment. During the project performance period of 2009-2014, the CBC provided an organizational framework for sustained public-private collaboration among more than 600 commercial building professionals, researchers and educators, utilities, and government agencies at federal, state, and local level. The CBC’s research has identified emerging technologies, market strategies, and innovative public and corporate policies to help advance CBI’s zero-net-energy. Finally, the CBC worked in close partnership with DOE’s commercial building teams and the Better Buildings Alliances to identify opportunities for proving out and deploying energy-saving technologies and practices.

99 GENERAL AND MISCELLANEOUS↗

Development and Validation of Smart Building Technology Modules for Academic and Professional Education

Slipstream leads a team developing a semester-long smart building curriculum for college students and adapting the contents into 16 training videos for building professionals and the public. The topics cover smart building technologies related content including industry trends and benefits, building systems, sensors and IoT devices, advanced building monitoring and controls, smart building control platform, methods, and applications.

99 GENERAL AND MISCELLANEOUS↗

Methodology for Modeling Building Energy Performance across the Commercial Sector

This report uses EnergyPlus simulations of each building in the 2003 Commercial Buildings Energy Consumption Survey (CBECS) to document and demonstrate bottom-up methods of modeling the entire U.S. commercial buildings sector (EIA 2006). The ability to use a whole-building simulation tool to model the entire sector is of interest because the energy models enable us to answer subsequent 'what-if' questions that involve technologies and practices related to energy. This report documents how the whole-building models were generated from the building characteristics in 2003 CBECS and compares the simulation results to the survey data for energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INL High-Performance and Sustainable Building Strategy

High-performance buildings are reliable, cost effective, and sustainable structures that minimize energy and water use, reduce solid waste and pollutant emissions, and limit the depletion of natural resources. High-performance buildings also provide a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) is the nation’s premier nuclear energy research laboratory, the physical infrastructure requires continual updating and repurposing to help accomplish that mission. INL’s infrastructure must incorporate high-performance sustainable design features to be fiscally responsible and reflect an image of innovation to the public and prospective employees. INL is a large consumer of energy with annual energy costs exceeding $16M. This High-Performance and Sustainable Building Strategy will help engineering and construction project teams design sustainable facilities, reduce life cycle operating costs, and support the INL net-zero plan while providing INL employees with a safe and healthy working environment. With these goals in mind, the recommendations described in this document are intended to form INL’s foundation for sustainable and high-performance building standards. This strategy incorporates the latest federal and Department of Energy (DOE) orders and directives, including DOE Order 436.1A, “Departmental Sustainability,” the DOE Sustainability Plan (SP), the INL Site Sustainability Plan (SSP), and Code of Federal Regulations (CFR). This document identifies the requirements of the “Guiding Principles for Sustainable Federal Buildings” (Guiding Principles) and briefly highlights the Leadership in Energy and Environmental Design (LEED) Gold certification. LEED Gold certification can be used to meet many of the requirements of the Guiding Principles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DOE Commercial Building Benchmark Models: Preprint

To provide a consistent baseline of comparison and save time conducting such simulations, the U.S. Department of Energy (DOE) has developed a set of standard benchmark building models. This paper will provide an executive summary overview of these benchmark buildings, and how they can save building analysts valuable time. Fully documented and implemented to use with the EnergyPlus energy simulation program, the benchmark models are publicly available and new versions will be created to maintain compatibility with new releases of EnergyPlus. The benchmark buildings will form the basis for research on specific building technologies, energy code development, appliance standards, and measurement of progress toward DOE energy goals. Having a common starting point allows us to better share and compare research results and move forward to make more energy efficient buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-based coefficients for adjusting climate impact on energy consumption of commercial buildings

This paper presents a new technique for and the results of normalizing building energy consumption to enable a fair comparison among various types of buildings located near different weather stations across the U.S. The method was developed for the U.S. Building Energy Asset Score, a whole-building energy efficiency rating system focusing on building envelope, mechanical systems, and lighting systems. The Asset Score is calculated based on simulated energy use under standard operating conditions. Existing weather normalization methods such as those based on heating and cooling degrees days are not robust enough to adjust all climatic factors such as humidity and solar radiation. In this work, over 1000 sets of climate coefficients were developed to separately adjust building heating, cooling, and fan energy use at each weather station in the United States. This paper also presents a robust, standardized weather station mapping based on climate similarity rather than choosing the closest weather station. This proposed simulated-based climate adjustment was validated through testing on several hundreds of thousands of modeled buildings. Results indicated the developed climate coefficients can isolate and adjust for the impacts of local climate for asset rating.

Asset Rating↗

A hybrid building thermal modeling approach for predicting temperatures in typical, detached, two-story houses

Within the residential building sector, the air-conditioning (AC) load is the main target for peak load shifting and reduction since it is the largest contributor to peak demand. By leveraging its power flexibility, residential AC is a good candidate to provide building demand response and peak load shifting. For realization of accurate and reliable control of AC loads, a building thermal model, which characterizes the properties of a building’s envelope and its thermal mass, is an essential component for accurate indoor temperature or cooling/heating demand prediction. Building thermal models include two types: “Forward” and “Data-Driven”. Due to time-saving and cost-effective characteristics, different data-driven models have been developed in a number of research studies. However, few developed models can predict temperatures in respective zones of a multiple-zone building with an open air path between zones e.g., an open stairwell connecting two floors of a home. In this research, a novel hybrid modeling approach is proposed to predict the average indoor air temperatures of both the upstairs and downstairs. This “hybrid” solution integrates both gray-box, i.e. RC model and black-box models. A developed RC model is used to predict the building mean temperature, and black-box model, in which the supervised machine learning algorithms are leveraged, is used to predict the temperature difference between the downstairs and upstairs. Compared with the measured data from a real house, the results obtained have acceptable/satisfactory accuracy. The method proposed in this study integrates the advantages of black-box and gray-box modeling. As a result, it can be used as a reliable alternative to predict the average temperatures in respective floors of typical detached two-story houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards COP27: Decarbonization patterns of residential building in China and India

As the two largest emerging emitters with the highest growth in operational carbon emissions from residential buildings, the historical emission patterns and decarbonization efforts of China and India warrant further exploration. This study aims to be the first to present a carbon intensity model considering end-use performances, assessing the operational decarbonization progress of residential building in India and China over the past two decades using the newest decomposing structural decomposition approach. Results indicate (1) the annual operational carbon intensity increased by 1.4% and 2.5% in China and India, respectively, between 2000 and 2020. Household expenditure-related energy intensity and emission factors were crucial in decarbonizing residential buildings. (2) Building electrification played a significant role in decarbonizing space cooling (–87.7 in China and – 130.2 kg of carbon dioxide (kgCO 2 ) per household in India) and appliances (~ –169.7 in China and ~ –43.4 kgCO 2 per household in India). (3) China and India collectively decarbonized 1498.3 and 399.7 M-tons of CO 2 in residential building operations, respectively. In terms of decarbonization intensity, India (164.8 kgCO 2 per household) nearly caught up with China (182.5 kgCO 2 per household) in 2020 and is expected to surpass China in the upcoming years, given the country's robust annual growth rate of 7.3%. Overall, this study provides an effective data-driven tool for investigating the building decarbonization potential in China and India, and offers valuable insights for other emerging economies seeking to decarbonize residential buildings in the forthcoming COP28 1 age.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An international review of occupant-related aspects of building energy codes and standards

In light of recent research, it is evident that occupants are playing an increasingly important role in building energy performance. Furthermore, despite the important role of building energy codes and standards in design, the occupant-related aspects are typically simple and have not kept up with the leading research. This paper reviews 23 regions’ building energy codes and standards by first comparing their quantitative aspects and then analyzing their mandated rules and approaches. While the present paper focuses on offices, general recommendations are applicable to other building types as well. The review revealed a wide range of occupant-related values, approaches, and attitudes. For example, code-specified occupant density varies by nearly a factor of three between different codes. This underlines the need for development of advancement in occupant behavior modeling approaches for future occupant-centric building performance codes and standards. Moreover, occupants are often referred to only implicitly; underlying expectations about energy-saving occupant behavior from building occupants varies greatly; and, only a few codes address occupant feedback and system usability. Based on the findings of the review, a set of initial recommendations for future building energy codes is proposed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An integrated environmental and health performance quantification model for pre-occupancy phase of buildings in China

To comprehensively pre-evaluate the damages to both the environment and human health due to construction activities in China, this paper presents an integrated building environmental and health performance (EHP) assessment model based on the Building Environmental Performance Analysis System (BEPAS) and the Building Health Impact Analysis System (BHIAS) models and offers a new inventory data estimation method. The new model follows the life cycle assessment (LCA) framework and the inventory analysis step involves bill of quantity (BOQ) data collection, consumption data formation, and environmental profile transformation. The consumption data are derived from engineering drawings and quotas to conduct the assessment before construction for pre-evaluation. The new model classifies building impacts into three safeguard areas: ecosystems, natural resources and human health. Thus, this model considers environmental impacts as well as damage to human wellbeing. The monetization approach, distance-to-target method and panel method are considered as optional weighting approaches. Finally, nine residential buildings of different structural types are taken as case studies to test the operability of the integrated model through application. The results indicate that the new model can effectively pre-evaluate building EHP and the structure type significantly affects the performance of residential buildings.

54 ENVIRONMENTAL SCIENCES↗

Survey and Analysis of Weather Data for Building Energy Simulations

In recent years, calibrated energy modeling of residential and commercial buildings has gained importance in a retrofit-dominated market. Accurate weather data plays an important role in this calibration process and projected energy savings. It would be ideal to measure weather data at the building location to capture relevant microclimate variation but this is generally considered cost-prohibitive. There are data sources publicly available with high temporal sampling rates but at relatively poor geospatial sampling locations. To overcome this limitation, there are a growing number of service providers that claim to provide real time and historical weather data for 20-35 km2 grid across the globe. Unfortunately, there is limited documentation from 3rd-party sources attesting to the accuracy of this data. This paper compares provided weather characteristics with data collected from a weather station inaccessible to the service providers. Monthly average dry bulb temperature; relative humidity; direct, diffuse and horizontal solar radiation; and wind speed are statistically compared. Moreover, we ascertain the relative contributions of each weather variable and its impact on building loads. Annual simulations are calculated for three different building types, including a closely monitored and automated energy efficient research building. The comparison shows that the difference for an individual variable can be as high as 90%. In addition, annual building energy consumption can vary by 7% while monthly building loads can vary by 40% as a function of the provided location s weather data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of peak power demand reduction available via modulation of building ventilation systems.

Peak power demand strains electrical grids and increases cost of electricity generation, transmission and distribution infrastructure. Many studies have examined ways of reducing peak power demand, including modification of room air temperature setpoints or reduction of lighting levels. However, very few or no studies have examined the peak power reduction resource offered by temporary curtailment of building ventilation systems. For this reason, we conducted a simulation campaign in which we examined the resource offered by temporary ventilation curtailment in commercial buildings of different use types across the United States and in residences in the state of California, with the essential constraint that any changes resulted in air quality acceptable to occupants through additional ventilation to compensate for the curtailment. To do this, we employed previously validated building models implemented in the airflow and contaminant transport tool CONTAM and building thermal and systems modeling tool EnergyPlus, in some cases co-simulated. Overall, results show savings are highly dependent on building type and climate but range from 0–2 W/ft 2 and up to 40% of total peak building power demand. Depending on building type, this power shed can be conducted for 1.5–8 h before acute exposure or odor concerns are expected, assuming a safety factor of 2. This reduction is of the same magnitude as that offered by thermal control strategies such as setpoint increase, or from lighting reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗