Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONNECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Evaluating the Environmental Impacts of Connected and Automated Vehicles: Potential Shortcomings of a Binned-Based Emissions Model

In addition to providing safety and mobility benefits, Connected and Automated Vehicles (CAVs) have the potential to reduce fuel consumption and emissions. As new CAV applications are developed, it is valuable to estimate these potential environmental benefits, typically using vehicle activity data and emissions models. To date, most researchers in the U.S. have used the MOVES vehicle emissions model, developed and maintained by the U.S. Environmental Protection Agency (EPA). However, because MOVES uses a binning approach, it is likely underestimating the true energy and emissions savings that occur when CAV applications smooth traffic flow. To illustrate this problem, we measure and model the fuel consumption and CO 2 emissions for a real-world CAV application: Eco-Approach and Departure (EAD) at signalized intersections. Real-world measurements are compared to a MOVES-based estimate, as well as to an estimate provided by the physical-based Comprehensive Modal Emissions Model (CMEM). Results show that MOVES consistently underestimates the energy and emissions benefits of the CAV application, primarily since the bin sizes in MOVES are too large to catch the nuances of traffic smoothing. On the other hand, CMEM provided a more accurate energy and emissions estimate, primarily since it uses analytical functions to model emissions and does not suffer from the same binning problem.

42 ENGINEERING↗

Switching-cycle-based Startup for Grid-connected Inverters

Conventional inverter startups, or grid synchronization, are hindered by slow dynamics and inrush current issues, which impede the integration of more renewable energy resources into the power grid. This paper overcomes the barriers by introducing a novel switching cycle-based startup approach for grid-connected inverters, eliminating the need for voltage sensors and phase-locked loops (PLLs). The proposed method surpasses the bandwidth constraints of traditional PLL-based techniques and achieves grid synchronization in just two switching cycles. Relying solely on sensed three-phase currents, synchronization is accomplished without inrush currents or the need for additional hardware or increased software complexity, resulting in a faster inverter startup. The paper also presents a sensitivity analysis to discuss the impact of critical parameters on the method's accuracy. As a result, the effectiveness of the proposed technique is demonstrated through simulation and experimental results.

14 SOLAR ENERGY↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

Distributed Estimation of All the Eigenvalues and Eigenvectors of Matrices Associated With Strongly Connected Digraphs

This letter considers the problem of estimating all the eigenvalues and eigenvectors of an irreducible matrix, corresponding to a strongly connected digraph, in the absence of knowledge on the global network topology. To this end, in this work we propose a unified distributed strategy performed by each node in the network and relies only on the local information. The key idea is to transform the nonlinear problem of computing both the eigenvalues and eigenvectors of an irreducible matrix into a linear one. Specifically, we first transform distributively the irreducible matrix into a nonsingular irreducible matrix. Each node in the network then estimates in a distributed fashion the inverse of the nonsingular matrix by solving a set of linear equations based on a consensus-type algorithm. The eigenvalues and the corresponding eigenvectors are finally computed by exploiting the relations between the eigenvalues and eigenvectors of both the inverse and the original irreducible matrices. A numerical example is provided to demonstrate the effectiveness of the proposed distributed strategy.

14 SOLAR ENERGY↗

Using Map Matching for DeIdentification of Connected Vehicle Locations

In this paper we introduce a location deidentification procedure that uses road network structure to protect against certain types of inference-based attacks. Our target is large databases containing vehicle locations. Previous anonymization approaches are inappropriate because location generalization and perturbation of geopositions could negatively affect development of safety-critical applications that require precise position information. Furthermore, k-anonymity-based clustering approaches would lead to significant data suppression. Our algorithm attempts to balance privacy protection and data utility, while protecting against re-identification attacks. Our data is from the first connected vehicle model deployment in the United States.

97 MATHEMATICS AND COMPUTING↗

Bringing Different Views Together: A Hybrid Cooperative Perception Framework for Connected Autonomous Vehicles

Cooperative perception will be essential for connected autonomous vehicles to enhance object recognition and optimize path planning by sending data information about the surrounding environment. However, an inherent challenge in existing systems is the high bandwidth cost of transmitting information in real-time, which restricts cooperative perception’s practicality. Here, this work presents a hybrid cooperative perception fusion framework aimed at mitigating this issue by optimizing data transmission according to available bandwidth or through data reduction techniques. Our methods ensure that vehicles can rapidly transmit high-confidence data without overwhelming the network. Experimental results indicate that our methodology substantially diminishes data transmission sizes while maintaining object detection accuracy. For cooperative perception in autonomous vehicle systems, our approach provides a scalable and effective way to get past the bandwidth barrier.

Carrillo, Dominic [Univ. of North Texas, Denton, T↗

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

Findings from Design and Operation of Connected Neighborhoods

Distributed energy resources and load management are an important emerging part of smart grids. Concurrent management of homeowner preferences and utility objectives requires an intelligent negotiation strategy supported by physical infrastructure that learns, optimizes, and controls the system. While there is a wide body of research related to modelling and simulation of distributed resources, relatively little is known about their practical feasibility. One of the first attempts to address this knowledge gap was through a 62-house connected neighborhood in Alabama. This study makes one more step in advancing this knowledge through a 46-townhome demonstration neighborhood located in Atlanta, GA. It reports hardware design, system architecture, and the results from the summer experimental work. The findings are discussed in the context of earlier experience, and analysis is expanded to areas which were not the focus of earlier research.

Tsybina, Eve↗

Fast Determination of Distribution-Connected PV Impacts Using a Variable-Time-Step Quasi-Static Time-Series Approach

The increasing deployment of distribution-connected photovoltaic (DPV) systems requires utilities to complete ever more complex interconnection studies. Relatively simple interconnection study methods worked well for low penetrations of photovoltaic systems, but more complicated quasistatic time-series (QSTS) analysis is required to make better interconnection decisions as DPV penetration levels increase. Tools and methods must be developed to support this type of complex analysis to enable efficient completion of PV impact studies. This paper presents a variable-time-step solver for QSTS analysis that significantly shortens the computational time and effort to complete a detailed analysis of the operation of a distribution circuit with many DPV systems. Specifically, it demonstrates that the proposed variable-time-step solver can reduce the required computational time by as much as 84% without introducing any important errors to metrics, such as the number of voltage regulator tap operations and highest and lowest voltage occurring on the distribution circuit during a 1-yr simulation period. Further improvement in computational speed is possible with the introduction of only modest errors in these metrics, such as a 91% reduction with less than 5% error when predicting voltage regulator operations. Furthermore, an alternate variable time-step method is also shown to perform adequately and shows promise of even greater reductions in simulation runtime.

14 SOLAR ENERGY↗

Base Station Antenna Uptilt Optimization for Cellular-Connected Drone Corridors

Reliable wireless coverage in drone corridors is critical to enable a connected, safe, and secure airspace. To support beyond visual line of sight (BVLOS) operations of aerial vehicles in a drone corridor, cellular base stations (BSs) can serve as a convenient infrastructure as they are widely deployed to provide seamless wireless coverage. However, antennas in the existing cellular networks are down-tilted to optimally serve their ground users, which results in coverage holes at higher altitudes when they are used to serve drones. In this paper, we consider the use of additional uptilted antennas at each cellular BS and optimize the uptilt angle to maximize the wireless coverage probability across a given drone corridor. Through numerical results, we can characterize the optimal value of the antenna uptilt angle for a given antenna pattern as well as the minimum/maximum altitudes of the drone corridor.

42 ENGINEERING↗

Brain Modulyzer: Interactive Visual Analysis of Functional Brain Connectivity

Here, we present Brain Modulyzer, an interactive visual exploration tool for functional magnetic resonance imaging (fMRI) brain scans, aimed at analyzing the correlation between different brain regions when resting or when performing mental tasks. Brain Modulyzer combines multiple coordinated views—such as heat maps, node link diagrams, and anatomical views—using brushing and linking to provide an anatomical context for brain connectivity data. Integrating methods from graph theory and analysis, e.g., community detection and derived graph measures, makes it possible to explore the modular and hierarchical organization of functional brain networks. Providing immediate feedback by displaying analysis results instantaneously while changing parameters gives neuroscientists a powerful means to comprehend complex brain structure more effectively and efficiently and supports forming hypotheses that can then be validated via statistical analysis. In order to demonstrate the utility of our tool, we also present two case studies—exploring progressive supranuclear palsy, as well as memory encoding and retrieval

59 BASIC BIOLOGICAL SCIENCES↗

Generic Multi-Frequency Modelling of Converter-Connected Renewable Energy Generators Considering Frequency and Sequence Couplings

Frequency and sequence couplings can compromise the trustworthiness of multi-frequency models for converter-based systems. There have been effective attempts to address the couplings mainly by linearized averaged models. Only a few studies have been conducted on practical optimization of such models with enormous matrices and experimental results. This paper provides a generic theory for coupling patterns and proposes a multi-frequency modelling method to detect and address only the main couplings in the sequence domain for converter-connected renewable energy generators. The proposed generic model is based on empirical tests using small-signal perturbations and adopting Fourier transform on the switching converter response. The proposed theory and modelling methodology are verified using a 7MVA grid emulator for voltage perturbation tests on a 2MVA photo-voltaic converter. Accordingly, the couplings can exist in more generic forms, including multiples of perturbation and fundamental frequencies. To the best of our knowledge, the patterns with the multiples of the perturbation frequency have been overlooked in the literature. Furthermore, the mirror frequency concept is valid for all coupling patterns and is included in the proposed model. Besides, the proposed patterns and the environment noise levels have been practical criteria for selecting the main couplings.

frequency and sequence couplings↗

A Blockchain-Enabled Sustainable Safety Management Framework for Connected Vehicles

The notion of an intelligent transportation system (ITS) aims to boost the performance of transportation networks, which has gained more and more traction in both academic and commercial circles. ITS is a constantly evolving vision that combines cutting-edge transportation approaches with new information, communication, computers, and other technology. ITS should discover consequence routes to enhance the sustainability, safety, and trustworthiness of the entire transportation system utilizing emerging technologies. In this paper, a sustainable safety management framework for connected vehicles is proposed by integrating blockchain. It introduces smart transportation equipment called an AI-enabled vehicle smart device (AVSD) for vehicular communications. AVSD can reduce energy consumption by decreasing the computational costs in vehicular communications. Smart contracts are used to identify vehicles automatically and establish secure communication among vehicles and emergency service stations (ESSs) like hospitals, police stations, and fire stations. The experiment results show that the proposed framework provides a communication environment for sustainable safety and security using the introduced smart transportation device. In conclusion, the proposed blockchain-enabled sustainable safety management framework has the potential to improve safety and sustainability in the transportation industry by creating a secure, decentralized, and transparent platform for managing safety data and promoting safe and sustainable driving behaviors.

42 ENGINEERING↗

Decentralized Interleaving of Parallel-Connected Buck Converters

We present a decentralized control strategy that yields switch interleaving for parallel-connected dc-dc buck converters. Compared to state-of-the-art methods that are distributed at best, the proposed architecture requires no communication, and hence, presents a variety of advantages with regard to reliability, modularity, and cost. The method is based on the digital implementation of the dynamics of a Lienard-type oscillator circuit as the controller for the converters. Each controller only requires the locally measured output current to synthesize the pulsewidth modulation (PWM) carrier waveform. The intrinsic electrical coupling between converters drives the nonlinear-oscillator-based controllers to converge to an interleaved state with uniform phase spacing across PWM carriers, independent of the number of converters, the load, and initial conditions. We provide analytical guarantees for existence and stability of the interleaved state as well as extensive hardware results for a system of five 120 W 48 V-to-12 V dc-dc buck converters that demonstrate convergence to the interleaved state in the face of a variety of large-signal disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized Carrier Phase Shifting for Optimal Harmonic Minimization in Asymmetric Parallel-Connected Inverters

This paper presents a carrier phase shifting technique for minimizing the aggregate harmonics in networks of asymmetric parallel-connected inverters for distributed power generation system applications. The proposed technique is: 1) implemented in a decentralized manner, relying only on local voltage and current measurements, and 2) optimal in the sense that it minimizes a cost function representing the carrier-frequency current harmonics. The analysis indicates that the proposed optimal carrier phase shifting technique can enable order-of-magnitude reductions in harmonic power, and also universal improvements compared to symmetric carrier interleaving for asymmetric inverter networks. Moreover, compared to existing methods that require either centralized communication or information exchange between inverters to coordinate carriers, the proposed technique is completely decentralized, which provides important practical benefits for implementation, including improved robustness and reduced cost. The technique is experimentally validated on a network of three single-phase 2-kW inverters and demonstrates a 36.5% reduction in the weighted total harmonic distortion factor of the aggregate inverter current, and the ability to converge to the optimal carrier phase spacing dynamically in less than one line frequency cycle (16.7 ms) in steady state and transient operating conditions.

42 ENGINEERING↗

A Single Passive Gate-Driver for Series Connected Power Devices in DC Circuit Breaker Applications

This letter proposes a novel single passive gate driver solution based on passive devices to control series-connected power semiconductor devices for dc circuit breaker (DCCB) applications. The transient suppression devices (e.g., metal oxide varistors) are utilized to achieve natural voltage balancing among the series devices, while providing the discharge path of the gate capacitor of the upper devices. Here, the proposed method is very simple, cost effective and more compact compared with conventional voltage balancing method-based DCCBs. Besides, gate voltage oscillation during the voltage recovery process is mitigated by the addition of an extra gate capacitor. Simulation and experimental results are provided to verify the effectiveness of proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗