Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONSISTENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Quasiparticle self-consistent GW band structures and phase transitions of LiAlO 2 in tetrahedrally and octahedrally coordinated structures

In this work, a first-principles computational study is presented of various phases of LiAlO 2 . The relative total energies and equations of state of the α, β, and γ phases are determined after structural relaxation of each phase. The β and γ tetrahedral phases are found to be very close in energy and lattice volume with the γ phase having the lowest energy. The octahedral α phase is a high-pressure phase and the transition pressure from the γ and β phases to α is determined to be about 1 GPa. The electronic band structures of each phase at their own equilibrium volume are determined using the quasiparticle self-consistent (QS) GW method as well as using the 0.8 Σ approach in which the QS GW self-energy is reduced by a factor of 0.8 to correct for the underscreening of W in QS GW. The effective masses of the band edges and the nature of the band gaps are presented. The lowest energy γ phase is found to have a pseudodirect gap of 7.69 eV. The gap is direct at Γ but corresponds to a dipole forbidden transition. The imaginary part of the dielectric function and the absorption coefficient are calculated in the long-wavelength limit and the random phase approximation, without local field or electron-hole interaction effects for each phase, and their anisotropies are discussed. Si doping on the Al site is investigated as a possible n-type dopant in γ-LiAlO 2 using a 128-atom supercell corresponding to 3.125% Si on the Al sublattice in the generalized gradient approximation and a smaller 16-atom cell with 25% Si in the QS GW approximation. The Si is found to significantly perturb the conduction band and lower the gap but a clearly separated deep donor defect level is not found. However, the donor binding energy is still expected to be relatively deep, on the order of a few tenths eV in the hydrogenic effective mass approximation.

36 MATERIALS SCIENCE↗

Metriplectic four-bracket algorithm for constructing thermodynamically consistent dynamical systems

A unified thermodynamic algorithm is presented for constructing thermodynamically consistent dynamical systems, i.e., systems that have Hamiltonian and dissipative parts that conserve energy while producing entropy. The algorithm is based on the metriplectic 4-bracket given in Morrison and Updike [Phys. Rev. E 109, 045202 (2024)]. A feature of the unified thermodynamic algorithm is the force-flux relation 𝐉 𝛼 =−𝐿 𝛼⁢𝛽 𝛁(𝛿⁢𝐻⁡/𝛿⁢𝜉 𝛽 ) for phenomenological coefficients 𝐿 𝛼⁢𝛽 , Hamiltonian 𝐻, and dynamical variables 𝜉 𝛽 . The algorithm is applied to the Navier-Stokes-Fourier, the Cahn-Hilliard-Navier-Stokes, and Brenner-Navier-Stokes-Fourier systems, and significant generalizations of these systems are obtained.

Multiphase flows↗

Electronic structure and exchange interactions in altermagnetic MnGeP 2 in the quasiparticle self-consistent G W approach

The quasiparticle self-consistent 𝐺⁡𝑊 method is used to study the electronic band structure, optical dielectric function, and exchange interactions in chalcopyrite, 𝐼⁢ ‾ 4 ⁢2⁢𝑑, structure MnGeP 2 . The material is found to be an antiferromagnetic semiconductor with a lowest direct gap of 2.44 eV at the Γ point and a lower indirect gap of 1.87 eV from Γ to 𝑀. The material is an altermagnet because the two magnetic atoms of opposite spin are related by a twofold rotation operation perpendicular to the main fourfold rotation inversion axis. The spin splittings along a low symmetry line like 𝑃⁢𝑁 is sizable while at k points on the diagonal mirror planes or on the twofold symmetry axes the spin splitting is zero. The exchange interactions are calculated using a linear response approach. The antiferromagnetic exchange interaction between nearest neighbors in the primitive unit cell is dominating and found to be slightly decreasing upon carrier doping but not sufficiently to change the interaction to become ferromagnetic. The bare (noninteracting) and interacting transverse spin susceptibilities, which provide interatomic site exchange interactions after averaging over the muffin-tin spheres, are calculated from the 𝐺⁡𝑊 band structure and wave functions. From these exchange interactions, the spin wave spectra are obtained along the high symmetry lines and the Néel temperature is calculated using the mean-field and Tyablikov estimations. The dielectric function and the optical absorption spectra are calculated including excitonic effects using the Bethe Salpeter equation. The exchange interactions around Mn Ge defect sites is also studied. While we find it can generate ferromagnetic interactions with neighboring spins, we did not find direct evidence of producing an overall ferromagnetic phase. First, if Mn antisites are introduced by exchanging Mn with a nearby Ge, the interactions stay largely antiferromagnetic. Second, when we add additional Mn, in other words in Mn-rich stoichiometry, the Mn Ge antisites produce a strong ferromagnetic interaction primarily with the Mn in the same basal plane but weaker ferromagnetic interaction with adjacent plane Mn. The interactions between regular lattice Mn stay antiferromagnetic as before and thus favor keeping the antiferromagnetic order along the [001] direction. Adding Mn antisites, however, does lead to a metallic band structure.

36 MATERIALS SCIENCE↗

Mapping the gas density with the kinematic Sunyaev-Zel’dovich and patchy screening effects: A self-consistent comparison

The secondary anisotropies of the cosmic microwave background (CMB) provide a wealth of astrophysical and cosmological information. Pairing measurements of the CMB temperature map obtained by DR5 of the Atacama Cosmology Telescope (ACT) with the imaging survey conducted by the Dark Energy Spectroscopic Instrument for the purposes of target selection, DECaLS DR9, we investigate two effects that are sensitive to the gas density 𝜏: kinematic Sunyaev-Zel’dovich (kSZ) and patchy screening or anisotropic screening (resulting from the Thomson scattering of CMB photons away from the line-of-sight by free electrons). In particular, we measure the stacked profiles of the gas density around luminous red galaxies (LRGs) at a mean redshift of 𝑧 ≈ 0.7. We detect the kSZ signal at 7.2⁢𝜎, and we find a signal at ∼ 4.1⁢𝜎 for the patchy screening estimator, which is in excess relative to the kSZ signal. We attribute this excess to contamination from CMB lensing. Here, we demonstrate the effect of lensing using 𝑁-body simulations, and we show that the screening signal is dominated by it. Accounting for lensing, our measurement places a 95% upper bound on the optical depth of the Extended DESI LRG sample of 𝜏 < 2.5 10 −4 for a mean value of the sample of 𝜏 ≈ 1.6 10 −4 . Furthermore, via hydro simulations, we show that the underlying optical depth signal measured by both effects (after removing the CMB lensing contribution) is in perfect agreement when adopting either a compensated aperture photometry (CAP) filter or a high-pass filter. Consistent with previous measurements, we see evidence for excess baryonic feedback around DESI LRGs in the patchy screening measurement. In the future, when both effects can be measured with high signal-to-noise, one can measure the amplitude ratio between them, which is proportional to the root-mean-square velocity of the host halo sample, and even place constraints on velocity-sensitive models such as modified gravity and phantom dark energy.

Astrophysical & cosmological simulations↗

New consistency tests for high-accuracy measurements of X-ray mass attenuation coefficients by the X-ray extended-range technique

An extension of the X-ray extended-range technique is described for measuring X-ray mass attenuation coefficients by introducing absolute measurement of a number of foils - the multiple independent foil technique. Illustrating the technique with the results of measurements for gold in the 38-50 keV energy range, it is shown that its use enables selection of the most uniform and well defined of available foils, leading to more accurate measurements; it allows one to test the consistency of independently measured absolute values of the mass attenuation coefficient with those obtained by the thickness transfer method; and it tests the linearity of the response of the counter and counting chain throughout the range of X-ray intensities encountered in a given experiment. In light of the results for gold, the strategy to be ideally employed in measuring absolute X-ray mass attenuation coefficients, X-ray absorption fine structure and related quantities is discussed.

58 GEOSCIENCES↗

Structure of Rhodococcus equi virulence-associated protein B (VapB) reveals an eight-stranded antiparallel β-barrel consisting of two Greek-key motifs

The structure of VapB, a member of the Vap protein family that is involved in virulence of the bacterial pathogen R. equi, was determined by SAD phasing and reveals an eight-stranded antiparallel β-barrel similar to avidin, suggestive of a binding function. Made up of two Greek-key motifs, the topology of VapB is unusual or even unique. Members of the virulence-associated protein (Vap) family from the pathogen Rhodococcus equi regulate virulence in an unknown manner. They do not share recognizable sequence homology with any protein of known structure. VapB and VapA are normally associated with isolates from pigs and horses, respectively. To contribute to a molecular understanding of Vap function, the crystal structure of a protease-resistant VapB fragment was determined at 1.4 Å resolution. The structure was solved by SAD phasing employing the anomalous signal of one endogenous S atom and two bound Co ions with low occupancy. VapB is an eight-stranded antiparallel β-barrel with a single helix. Structural similarity to avidins suggests a potential binding function. Unlike other eight- or ten-stranded β-barrels found in avidins, bacterial outer membrane proteins, fatty-acid-binding proteins and lysozyme inhibitors, Vaps do not have a next-neighbour arrangement but consist of two Greek-key motifs with strand order 41238567, suggesting an unusual or even unique topology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Endogenous Interface Pricing for Consistent Transmission–Distribution Co-Optimization With Discrete Distribution Controls

This paper proposes an endogenous interface pricing model for day-ahead transmission–distribution co-optimization that co-determines the interface locational marginal price (LMP) and the transmission–distribution exchange, ensuring price–dispatch consistency while optimally scheduling discrete distribution controls. The formulation couples a DC optimal power flow (OPF) with a branch-flow AC OPF that schedules distributed energy resources (DERs), tap-changer settings, capacitor banks (CBs), and multi-period energy storage systems (ESSs) under feeder voltage and current limits, and is solved as a mixed-integer second-order cone program (MISOCP). In a T14–D33 system, coordinated device scheduling recovers about 90% of the distribution-to-transmission export achievable in a reference case that ignores distribution network (DN) limits, while satisfying a 1.05 p.u. voltage upper bound. In a T39–D34/D37/D123 system, a sequential decoupled benchmark produces interface LMP distortions up to 12.5% and a 7.28% mismatch in net export energy, whereas the proposed model removes these distortions and the associated settlement mismatches. Second-order cone (SOC) relaxation gaps remain below $10^{-3}$ in all cases.

Noh, Seung-Gil↗

CMAD: A Self-consistent Parallel Code to Simulate the Electron Cloud Build-up and Instabilities

We present the features of CMAD, a newly developed self-consistent code which simulates both the electron cloud build-up and related beam instabilities. By means of parallel (Message Passing Interface - MPI) computation, the code tracks the beam in an existing (MAD-type) lattice and continuously resolves the interaction between the beam and the cloud at each element location, with different cloud distributions at each magnet location. The goal of CMAD is to simulate single- and coupled-bunch instability, allowing tune shift, dynamic aperture and frequency map analysis and the determination of the secondary electron yield instability threshold. The code is in its phase of development and benchmarking with existing codes. Preliminary results on benchmarking are presented in this paper.

43 PARTICLE ACCELERATORS↗

Toward Consistent High-Fidelity Quantum Learning on Unstable Devices via Efficient In-Situ Calibration

In the near-term noisy intermediate-scale quantum (NISQ) era, high noise will significantly reduce the fidelity of quantum computing. What's worse, recent works reveal that the noise on quantum devices is not stable, that is, the noise is dynamically changing over time. This leads to an imminent challenging problem: At run-time, is there a way to efficiently achieve a consistent high-fidelity quantum system on unstable devices? To study this problem, we take quantum learning (a.k.a., variational quantum algorithm) as a vehicle, which has a wide range of applications, such as combinatorial optimization and machine learning. A straightforward approach is to optimize a variational quantum circuit (VQC) with a parameter-shift approach on the target quantum device before using it; however, the optimization has an extremely high time cost, which is not practical at run-time. To address the pressing issue, in this paper, we proposed a novel quantum pulse-based noise adaptation framework, namely QuPAD. In the proposed framework, first, we identify that the CNOT gate is the fidelity bottleneck of the conventional VQC, and we employ a more robust parameterized multi-qubit gate (i.e., Rzx gate) to replace CNOT gate. Second, by benchmarking Rzx gate with different parameters, we build a fitting function for each coupling qubit pair, such that the deviation between the theoretic output of Rzx gate and its on-device output under a given pulse amplitude and duration can be efficiently predicted. On top of this, an evolutionary algorithm is devised to identify the pulse amplitude and duration of each Rzx gate (i.e., calibration) and find the quantum circuits with high fidelity. Experiments show that the runtime on quantum devices of QuPAD with 8–10 qubits is less than 15 minutes, which is up to 270 x faster than the parameter-shift approach. In addition, compared to the vanilla VQC as a baseline, QuPAD can achieve 59.33% accuracy gain on a classification task, and average 66.34% closer to ground state energy for molecular simulation.

Hu, Zhirui↗

Cycle-Consistent Adversarial Networks for Realistic Pervasive Change Generation in Remote Sensing Imagery

This paper introduces a new method of generating realistic pervasive changes in the context of evaluating the effectiveness of change detection algorithms in controlled settings. The method - a cycle-consistent adversarial network (CycleGAN) - requires low quantities of training data to generate realistic changes. Here we show an application of CycleGAN in creating realistic snow-covered scenes of multispectral Sentinel-2 imagery, and demonstrate how these images can be used as a test bed for anomalous change detection algorithms.

97 MATHEMATICS AND COMPUTING↗

Switchgrass ( Panicum Virgatum ) and Miscanthus ( Miscanthus × Giganteus ) Long-Term Yield Patterns Reveal Consistent Productivity Declines

Perennial grasses like switchgrass ( Panicum virgatum ) and miscanthus ( Miscanthus × giganteus ) are expected to supply a substantial amount of the United States bioeconomy's feedstock demand. However, uncertainties around their long-term yields challenge the viability of their potential and limit their wider adoption. To resolve their long-term yield patterns, we analyzed over 200 plantings of switchgrass and miscanthus across Michigan and Wisconsin, USA, measured over 5–15 years. We found a consistent two-phase long-term yield dynamic; during a yield-building phase , peak yields occurred within 4–5 years after planting, followed by a yield-decline phase in which switchgrass and miscanthus lost 30%–47% and 14%–40% of peak yields, respectively. Among the potential drivers of this dynamic and the yield decline, we found that weather conditions had little impact, as the variation across years was not large enough to drive the observed yield differences. Added nitrogen increased peak yields by 10%–20% and attenuated the yield decline by 20%–50%. However, since fertilized stands still showed a yield decline, other factors became limiting as stands aged. This conserved long-term yield dynamic has direct implications on management. A farm-to-gate economic analysis suggests replanting switchgrass and miscanthus 5 and 9 years following their peak yields maximizes profit over a 30-year time horizon. Results call for further management and breeding strategies to mitigate the yield-decline phase, and for reparameterization of global bioenergy models with carbon capture and storage, which may overestimate yields and the economic and environmental benefits of crops grown for bioenergy feedstocks.

bioenergy↗

A Minimum Creep Rate for 2-1/4Cr-1Mo Steel Consistent With the ASME Section III, Division 5 Rules

This technical note describes a minimum creep rate model for 2-1/4Cr-1Mo steel that is consistent with the current creep strain equation embedded in the ASME Boiler & Pressure Vessel Code Section III, Division 5, Subsection HB, Subpart B isochronous stress–strain curves. Minimum creep rate models for all the Section III, Division 5 Class A materials are required for the development of improved high temperature design methods. Of all the Class A materials, only 2-1/4Cr-1Mo does not have a readily identifying minimum creep rate term in the current isochronous stress–strain curve model.

36 MATERIALS SCIENCE↗

SU-E-T-96: Demonstration of a Consistent Method for Correcting Surface Dose Measurements Using Both Solid State and Ionization Chamber Detectors

Purpose: To compare the surface dose (SD) measured using a PTW 30-360 extrapolation chamber with different commonly used dosimeters (Ds): parallel plate ion chambers (ICs): RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial; TLD chips (cTLD), TLD powder (pTLD), optically stimulated (OSLs), radiochromic (EXR2) and radiographic (EDR2) films, and to provide an intercomparison correction to Ds for each of them. Methods: Investigations were performed for a 6 MV x-ray beam (Varian Clinac 2300, 10x10 cm{sup 2} open field, SSD = 100 cm). The Ds were placed at the surface of the solid water phantom and at the reference depth dref=1.7cm. The measurements for cTLD, OSLs, EDR2 and EXR2 were corrected to SD using an extrapolation method (EM) indexed to the baseline PTW 30-360 measurements. A consistent use of the EM involved: 1) irradiation of three Ds stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. An additional measurement was performed with externally exposed OSLs (eOSLs), that were rotated out of their protective housing. Results: All single Ds measurements overestimated the SD compared with the extrapolation chamber, except for Attix IC. The closest match to the true SD was measured with the Attix IC (− 0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EXR2 (14%), EDR2 (14.8%) and OSL (26%). The EM method of correction for SD worked well for all Ds, except the unexposed OSLs. Conclusion: This EM cross calibration of solid state detectors with an extrapolation or Attix chamber can provide thickness corrections for cTLD, eOSLs, EXR2, and EDR2. Standard packaged OSLs were not found to be simply corrected.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-01: Consistency of Lung Expansion and Contraction During Respiration: Implications for Quantitative Imaging

Purpose: Four-dimensional computed tomography (4DCT) can be used to evaluate longitudinal changes in pulmonary function. The sensitivity of such measurements to identify function change may be improved with reproducible breathing patterns. The purpose of this study was to determine if inhale was more consistent than exhale, i.e., lung expansion during inhalation compared to lung contraction during exhalation. Methods: Repeat 4DCT image data acquired within a short time interval from 8 patients. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. Equivalent lung volumes (ELV) were used for 5 subjects and equivalent title volumes (ETV) for the 3 subjects who experienced a baseline shift between scans. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2mm distance-to-agreement and 5% ventilation difference. The gamma pass rates were then compared using paired t-test to determine if there was a significant difference. Results: Inhalation was more reproducible than exhalation. In the 5 ELV subjects 78.5% of the lung voxels met the gamma criteria for expansion during inhalation when comparing the two scans, while significantly fewer (70.9% of the lung voxels) met the gamma criteria for contraction during exhalation (p = .027). In the 8 total subjects analyzed the average gamma pass rate for expansion during inhalation was 75.2% while for contraction during exhalation it was 70.3%; which trended towards significant (p = .064). Conclusion: This work implies inhalation is more reproducible than exhalation, when equivalent respiratory volumes are considered. The reason for this difference is unknown. Longitudinal investigation of pulmonary function change based on inhalation images appears appropriate for Jacobian-based measure of lung tissue expansion. NIH Grant: R01 CA166703.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-04: Quantitative Texture Features Calculated in Lung Tissue From CT Scans Demonstrate Consistency Between Two Databases From Different Institutions

Purpose: To evaluate the consistency of computed tomography (CT) scan texture features, previously identified as stable in a healthy patient cohort, in esophageal cancer patient CT scans. Methods: 116 patients receiving radiation therapy (median dose: 50.4Gy) for esophageal cancer were retrospectively identified. For each patient, diagnostic-quality pre-therapy (0-183 days) and post-therapy (5-120 days) scans (mean voxel size: 0.8mm×0.8mm×2.5mm) and a treatment planning scan and associated dose map were collected. An average of 501 32x32-pixel ROIs were placed randomly in the lungs of each pre-therapy scan. ROI centers were mapped to corresponding locations in post-therapy and planning scans using the displacement vector field output by demons deformable registration. Only ROIs with mean dose <5Gy were analyzed, as these were expected to contain minimal post-treatment damage. 140 texture features were calculated in pre-therapy and post-therapy scan ROIs and compared using Bland-Altman analysis. For each feature, the mean feature value change and the distance spanned by the 95% limits of agreement were normalized to the mean feature value, yielding normalized range of agreement (nRoA) and normalized bias (nBias). Using Wilcoxon signed rank tests, nRoA and nBias were compared with values computed previously in 27 healthy patient scans (mean voxel size: 0.67mm×0.67mm×1mm) acquired at a different institution. Results: nRoA was significantly (p<0.001) larger in cancer patients than healthy patients. Differences in nBias were not significant (p=0.23). The 20 features identified previously as having nRoA<20% for healthy patients had the lowest nRoA values in the current database, with an average increase of 5.6%. Conclusion: Despite differences in CT scanner type, scan resolution, and patient health status, the same 20 features remained stable (i.e., low variability and bias) in the absence of disease changes for databases from two institutions. Identification of these features is the first step towards quantifying radiation-induced changes between preand post-therapy scans. Supported, in part, by NIH Grant Nos. S10 RR021039, and P30 CA14599, the Virginia and D. K. Ludwig Fund for Cancer Research, Imaging Research Institute, Biological Sciences Division, The University of Chicago, and The Institute for Translational Medicine Pilot Award, The University of Chicago.

60 APPLIED LIFE SCIENCES↗

On the consistency of Monte Carlo track structure DNA damage simulations

Purpose: Monte Carlo track structures (MCTS) simulations have been recognized as useful tools for radiobiological modeling. However, the authors noticed several issues regarding the consistency of reported data. Therefore, in this work, they analyze the impact of various user defined parameters on simulated direct DNA damage yields. In addition, they draw attention to discrepancies in published literature in DNA strand break (SB) yields and selected methodologies. Methods: The MCTS code Geant4-DNA was used to compare radial dose profiles in a nanometer-scale region of interest (ROI) for photon sources of varying sizes and energies. Then, electron tracks of 0.28 keV–220 keV were superimposed on a geometric DNA model composed of 2.7 × 10{sup 6} nucleosomes, and SBs were simulated according to four definitions based on energy deposits or energy transfers in DNA strand targets compared to a threshold energy E{sub TH}. The SB frequencies and complexities in nucleosomes as a function of incident electron energies were obtained. SBs were classified into higher order clusters such as single and double strand breaks (SSBs and DSBs) based on inter-SB distances and on the number of affected strands. Results: Comparisons of different nonuniform dose distributions lacking charged particle equilibrium may lead to erroneous conclusions regarding the effect of energy on relative biological effectiveness. The energy transfer-based SB definitions give similar SB yields as the one based on energy deposit when E{sub TH} ≈ 10.79 eV, but deviate significantly for higher E{sub TH} values. Between 30 and 40 nucleosomes/Gy show at least one SB in the ROI. The number of nucleosomes that present a complex damage pattern of more than 2 SBs and the degree of complexity of the damage in these nucleosomes diminish as the incident electron energy increases. DNA damage classification into SSB and DSB is highly dependent on the definitions of these higher order structures and their implementations. The authors’ show that, for the four studied models, different yields are expected by up to 54% for SSBs and by up to 32% for DSBs, as a function of the incident electrons energy and of the models being compared. Conclusions: MCTS simulations allow to compare direct DNA damage types and complexities induced by ionizing radiation. However, simulation results depend to a large degree on user-defined parameters, definitions, and algorithms such as: DNA model, dose distribution, SB definition, and the DNA damage clustering algorithm. These interdependencies should be well controlled during the simulations and explicitly reported when comparing results to experiments or calculations.

60 APPLIED LIFE SCIENCES↗

Data consistency conditions for truncated fanbeam and parallel projections

Purpose: In image reconstruction from projections, data consistency conditions (DCCs) are mathematical relationships that express the overlap of information between ideal projections. DCCs have been incorporated in image reconstruction procedures for positron emission tomography, single photon emission computed tomography, and x-ray computed tomography (CT). Building on published fanbeam DCCs for nontruncated projections along a line, the authors recently announced new DCCs that can be applied to truncated parallel projections in classical (two-dimensional) image reconstruction. These DCCs take the form of polynomial expressions for a weighted backprojection of the projections. The purpose of this work was to present the new DCCs for truncated parallel projections, to extend these conditions to truncated fanbeam projections on a circular trajectory, to verify the conditions with numerical examples, and to present a model of how DCCs could be applied with a toy problem in patient motion estimation with truncated projections. Methods: A mathematical derivation of the new parallel DCCs was performed by substituting the underlying imaging equation into the mathematical expression for the weighted backprojection and demonstrating the resulting polynomial form. This DCC result was extended to fanbeam projections by a substitution of parallel to fanbeam variables. Ideal fanbeam projections of a simple mathematical phantom were simulated and the DCCs for these projections were evaluated by fitting polynomials to the weighted backprojection. For the motion estimation problem, a parametrized motion was simulated using a dynamic version of the mathematical phantom, and both noiseless and noisy fanbeam projections were simulated for a full circular trajectory. The fanbeam DCCs were applied to extract the motion parameters, which allowed the motion contamination to be removed from the projections. A reconstruction was performed from the corrected projections. Results: The mathematical derivation revealed the anticipated polynomial behavior. The conversion to fanbeam variables led to a straight-forward weighted fanbeam backprojection which yielded the same function and therefore the same polynomial behavior as occurred in the parallel case. Plots of the numerically calculated DCCs showed polynomial behavior visually indistinguishable from the fitted polynomials. For the motion estimation problem, the motion parameters were satisfactorily recovered and ten times more accurately for the noise-free case. The reconstructed images showed that only a faint trace of the motion blur was still visible after correction from the noisy motion-contaminated projections. Conclusions: New DCCs have been established for fanbeam and parallel projections, and these conditions have been validated using numerical experiments with truncated projections. It has been shown how these DCCs could be applied to extract parameters of unwanted physical effects in tomographic imaging, even with truncated projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-211: Assessing the Consistency of the ViewRay 0.35 T MRI System

Purpose: ViewRay is a novel image-guided radiotherapy approach with an integrated 0.35 T MR unit and three Cobalt-60 heads. In order to continuously ensure the high resolution and high soft tissue contrast available in MR images, we quantified a multitude of relevant imaging parameters over a period of six months to establish its stability and imaging quality. In the assessment process, consideration is also given to the need to establish the number of tests required to have confidence in the performance of the system for radiation therapy planning applications. Methods: Daily, weekly, monthly and annual imaging tests were performed over a period of six months using standardized phantoms (a 24 cm diameter sphere and the ACR phantom) to quantify the performance of the system. In addition to the ACR and NEMA recommended tests, we also included element testing, spatial integrity, Eddy current and magnetic field inhomogeneity measurements. The ACR test is used for assessing the following parameters for T1 and T2: geometric accuracy, high contrast spatial resolution, slice thickness accuracy, slice position accuracy, percent signal ghosting, low contrast object detectability. It also includes percent image uniformity (PIU) for T1. The NEMA test is primarily designed to check SNR and PIU. Results: Over the period of six months, all the parameters were maintained within the recommendations provided in the ACR and NEMA standards. PIU and SNR were found to be sensitive to malfunctions in the components of the multileaf collimators. Details of the findings will be presented. Conclusion: The data suggests that ViewRay imaging system has functioned in a consistent and reliable manner. MR imaging from ViewRay 0.35T system complies with the ACR and NEMA recommended acceptance standards.

60 APPLIED LIFE SCIENCES↗