Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collective levels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Modulation of centimetric waves by long gravity waves - Progress report on field and laboratory results

Results are presented from laboratory and field experiments on the modulation of short waves by long waves. The field study employed a wave follower capable of tracking ocean waves with frequencies less than 1.0 Hz and heights less than 2.0 m. A high-response laser-optical system was used to detect upwind-downwind and cross-wind slopes of short waves. The laboratory study was conducted with wind over periodic long waves. The laboratory findings are discussed and compared with laboratory radar measurements and also short wave measurements obtained in the field. It is found that long waves significantly modulate the short wave dispersion by their orbital velocity, and that demodulation is necessary if the data collected by remote sensors are to be compared to surface penetrating devices. The modulation level is weak for wavelengths in the range 2.76-3.30 cm. Other relevant results are also presented.

Shemdin, O. H.↗

Comparison of level I land cover classification accuracy for MSS and AVHRR data

The capabilities of the Advanced Very-High-Resolution Radiometer (AVHRR) for land-cover mapping were investigated by comparing the accuracy of land-cover information for the Washington, DC area derived from NOAA-7 AVHRR data with that from Landsat Multispectral Scanner Subsystem (MSS) data. Unsupervised level I land-cover classifications were performed for MSS and AVHRR data sets collected on July 11, 1981. A detailed accuracy assessment was conducted based on ground data delineated on 12 U.S. Geological Survey 7-5 min series topographic maps. These results produced overall land-cover classification accuracies of 71.9 and 76.8 per cent for AVHRR and MSS, respectively. While the accuracies for predominant categories were similar for both sensors, land-cover discrimination for less commonly occurring and/or spatially heterogeneous categories was improved with the MSS data set. The AVHRR, however, performed as well as or better than the MSS in classifying large homogeneous areas. The application of AVHRR data with its lower processing cost and more frequent worldwide coverage appears promising for regional land-cover mapping.

Gervin, J. C.↗

O 7774 A diagnostic for quiescent prominences

Results are reported from photometric observations and statistical analyses of the O 7774 A (3/5/P yields 3/5/S) transition in quiescent solar prominences. The goal of the study was to derive accurate values for the ratio between the population density of the upper level of the observed transition relative to the total O population. The data were collected with the 25 cm coronagraph/3 m spectrograph at the Mees Solar Observatory. A strong temperature dependence was found for the transition, indicating that the O 7774 A/Na 5890 A ratio is of use for diagnostic studies of quiescent prominences. The possibility of applying the ratio as a diagnostic for spicules is discussed.

Brickhouse, Nancy S.↗

Precision orbit determination for the Geosat Exact Repeat Mission

Precise ephemerides have been determined for the U.S. Navy Geosat Exact Repeat Mission (ERM) using an improved gravity-field model, PTGF-4A (Shum et al. 1989). The Geosat orbits were computed in a terrestrial reference system which is tied to the reference system defined by satellite laser ranging (SLR) to Lageos through a survey between the Tranet Doppler receiver and the SLR system located at Wettzell, FRG. The remaining Doppler tracking station coordinates were estimated simultaneously with the geopotential in the PTGF-4A solution. In this analysis, three continuous 17-day Geosat orbits, which were computed using the 46-station Tranet data and global altimeter crossover data, have a crossover residual rms of 20 cm, indicating that the Geosat radial orbit error is of the order of 20 cm. The orbits computed based on data collected by a 7-station OPNET tracking network and crossover data have the same level of accuracy.

Shum, C. K.↗

Nonconservative force model parameter estimation strategy for TOPEX/Poseidon precision orbit determination

The TOPEX/Poseidon spacecraft was launched on August 10, 1992 to study the Earth's oceans. To achieve maximum benefit from the altimetric data it is to collect, mission requirements dictate that TOPEX/Poseidon's orbit must be computed at an unprecedented level of accuracy. To reach our pre-launch radial orbit accuracy goals, the mismodeling of the radiative nonconservative forces of solar radiation, Earth albedo an infrared re-radiation, and spacecraft thermal imbalances cannot produce in combination more than a 6 cm rms error over a 10 day period. Similarly, the 10-day drag modeling error cannot exceed 3 cm rms. In order to satisfy these requirements, a 'box-wing' representation of the satellite has been developed in which, the satellite is modelled as the combination of flat plates arranged in the shape of a box and a connected solar array. The radiative/thermal nonconservative forces acting on each of the eight surfaces are computed independently, yielding vector accelerations which are summed to compute the total aggregate effect on the satellite center-of-mass. Select parameters associated with the flat plates are adjusted to obtain a better representation of the satellite acceleration history. This study analyzes the estimation of these parameters from simulated TOPEX/Poseidon laser data in the presence of both nonconservative and gravity model errors. A 'best choice' of estimated parameters is derived and the ability to meet mission requirements with the 'box-wing' model evaluated.

Luthcke, S. B.↗

A distributed parallel storage architecture and its potential application within EOSDIS

We describe the architecture, implementation, use of a scalable, high performance, distributed-parallel data storage system developed in the ARPA funded MAGIC gigabit testbed. A collection of wide area distributed disk servers operate in parallel to provide logical block level access to large data sets. Operated primarily as a network-based cache, the architecture supports cooperation among independently owned resources to provide fast, large-scale, on-demand storage to support data handling, simulation, and computation.

Johnston, William E.↗

Conservative force model performance for TOPEX/Poseidon precision orbit determination

The TOPEX/Poseidon spacecraft was launched on August 10, 1992 to study the Earth's oceans. To achieve maximum benefit from the altimetric data collected, mission requirements dictate that TOPEX/Poseidon's orbit must be computed at an unprecedented level of accuracy. In order to satisfy these requirements, a model which accounts for the satellite's complex geometry, attitude, and surface properties has been developed. This `box-wing' representation treats the spacecraft as the combination of flat plates arranged in the shape of a box and a connecetd solar array. The nonconservative forces acting on each of the eight surfaces are computed independently, yielding vector accelerations which are summed to compute the total aggregate effect on the satellite center-of-mass. Parameters associated with each flat plate were derived from a finite element analysis of the spacecraft. Certain parameters can be inferred from tracking data and have been adjusted to obtain a better representation of the satellite acceleration history. Changes in the nominal mission profile and the presence of an `anomalistic' force have complicated this tuning process. Model performance, parameter sensitivities, and the `anomalistic' force will be discussed.

Marshall, J. Andrew↗

Laboratory Astrophysics Needs of the Herschel Space Observatory

The science teams of the Herschel Space Observatory have identified a number of areas where laboratory study is required for proper interpretation of Herschel observational data. The most critical is the collection and compilation of laboratory data on spectral line frequencies, transition probabilities and energy levels for the known astrophysical atomic and molecular species in 670 to 57 micron wavelength range of Herschel. The second most critical need is the compilation of collisional excitation cross sections for the species known to dominate the energy balance in the ISM and the temperature dependent chemical reaction rates. On the theoretical front, chemical and radiative transfer models need to be prepared in advance to assess calibration and identify instrument anomalies. In the next few years there will be a need to incorporate spectroscopists and theoretical chemists into teams of astronomers so that the spectroscopic surveys planned can he properly calibrated and rapidly interpreted once the data becomes available. The science teams have also noted that the enormous prospects for molecular discovery will be greatly handicapped by the nearly complete lack of spectroscopic data for anything not already well known in the ISM. As a minimum, molecular species predicted to exist by chemical models should be subjected to detailed laboratory study to ensure conclusive detections. This has the greatest impact on any astrobiology program that might be proposed for Herschel. Without a significant amount of laboratory work in the very near future Herschel will not be prepared for many planned observations, much less addressing the open questions in molecular astrophysics.

Pearson, J. C.↗

Genesis Discovery Mission: Science Canister Processing at JSC

Genesis addresses questions about materials and processes involved in the origins of the solar system by providing precise knowledge of solar isotopic and elemental compositions. Solar wind ions are collected and returned to Earth for analyses. The spacecraft has two primary instruments to collect solar wind: a set of collector arrays each of which can deploy to sample different solar wind regimes, and a concentrator that is an electrostatic mirror to concentrate and focus low mass ions onto a 6 cm target. One of the key challenges to obtaining a good sample of solar wind, uncontaminated by terrestrial atoms, is to have clean collection surfaces in a clean sample canister and clean facilities to handle the samples for allocation and future reference. The Johnson Space Center (JSC) is responsible for contamination control for the mission, for ensuring the cleanliness of collection surfaces, and for providing a clean environment for handling of the samples. The level of cleanliness required is high; at the time of analysis (after sample return), the surface contamination by C, N, O must each be <10(exp 15) atoms/sq cm and for other elements the number of atoms/sq cm of each surface contaminant shall not exceed the estimated solar wind fluence of the species (varies by element between U at approx. 10(exp 4) atoms/sq cm to Fe, Si, Mg, and Ne at approx. 10(exp 12) atoms/sq cm).

Stansbery, E. K.↗

Techniques for measurement of thoracoabdominal asynchrony

Respiratory motion measured by respiratory inductance plethysmography often deviates from the sinusoidal pattern assumed in the traditional Lissajous figure (loop) analysis used to determine thoraco-abdominal asynchrony, or phase angle phi. We investigated six different time-domain methods of measuring phi, using simulated data with sinusoidal and triangular waveforms, phase shifts of 0-135 degrees, and 10% noise. The techniques were then used on data from 11 lightly anesthetized rhesus monkeys (Macaca mulatta; 7.6 +/- 0.8 kg; 5.7 +/- 0.5 years old), instrumented with a respiratory inductive plethysmograph, and subjected to increasing levels of inspiratory resistive loading ranging from 5-1,000 cmH(2)O. L(-1). sec(-1).The best results were obtained from cross-correlation and maximum linear correlation, with errors less than approximately 5 degrees from the actual phase angle in the simulated data. The worst performance was produced by the loop analysis, which in some cases was in error by more than 30 degrees. Compared to correlation, other analysis techniques performed at an intermediate level. Maximum linear correlation and cross-correlation produced similar results on the data collected from monkeys (SD of the difference, 4.1 degrees ) but all other techniques had a high SD of the difference compared to the correlation techniques.We conclude that phase angles are best measured using cross-correlation or maximum linear correlation, techniques that are independent of waveform shape, and robust in the presence of noise. Copyright 2002 Wiley-Liss, Inc.

Non-NASA Center↗

Space Acceleration Measurement System for Free Flyers

Experimenters from the fluids, combustion, materials, and life science disciplines all use the microgravity environment of space to enhance their understanding of fundamental physical phenomena caused by disturbances from events such as spacecraft maneuvers, equipment operations, atmospheric drag, and (for manned flights) crew movement. Space conditions reduce gravity but do not eliminate it. To quantify the level of these disturbances, NASA developed the Space Acceleration Measurement System (SAMS) series to collect data characterizing the acceleration environment on the space shuttles. This information is provided to investigators so that they can evaluate how the microgravity environment affects their experiments. Knowledge of the microgravity environment also helps investigators to plan future experiments. The original SAMS system flew 20 missions on the shuttle as well as on the Russian space station Mir. Presently, Lewis is developing SAMS-II for the International Space Station; it will be a distributed system using digital output sensor heads. The latest operational version of SAMS, SAMS-FF, was originally designed for free flyer spacecraft and unmanned areas. SAMS-FF is a flexible, modular system, housed in a lightweight package, and it uses advances in technology to improve performance. The hardware package consists of a control and data acquisition module, three different types of sensors, data storage devices, and ground support equipment interfaces. Three different types of sensors are incorporated to measure both high- and low-frequency accelerations and the roll rate velocity. Small, low-power triaxial sensor heads (TSH's) offer high resolution and selectable bandwidth, and a special low-frequency accelerometer is available for high-resolution, low-frequency applications. A state-of-the-art, triaxial fiberoptic gyroscope that measures extremely low roll rates is housed in a compact package. The versatility of the SAMS-FF system is shown in the three different types of missions SAMS-FF has supported.

Kacpura, Thomas J.↗

International Satellite Cloud Climatology Project (ISCCP) Stage DX Pixel Level Cloud Product - Revised Algorithm in Native (NAT) Format (ISCCP_DX_NAT)

Since 1983 an international group of institutions has collected and analyzed satellite radiance measurements from up to five geostationary and two polar orbiting satellites to infer the global distribution of cloud properties and their diurnal, seasonal and interannual variations. The primary focus of the first phase of the project (1983-1995) was the elucidation of the role of clouds in the radiation budget (top of the atmosphere and surface). In the second phase of the project (1995 onwards) the analysis also concerns improving understanding of clouds in the global hydrological cycle. [Location=TROPOSPHERE] [Temporal_Coverage: Start_Date=1983-07-01; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=30 Km; Longitude_Resolution=30 Km; Temporal_Resolution=3 Hourly].

CLOUD ICE↗

Feasibility Study of a Lunar Analog Bed Rest Model

The purpose of this study was to determine the feasibility of using a 9.5deg head-up tilt bed rest model to simulate the effects of the 1/6 g load to the human body that exists on the lunar surface. The lunar analog bed rest model utilized a modified hospital bed. The modifications included mounting the mattress on a sled that rolled on bearings to provide freedom of movement. The weight of the sled was off-loaded using a counterweight system to insure that 1/6 body weight was applied along the long axis (z-axis) of the body. Force was verified through use of a force plate mounted at the foot of the bed. A seating assembly was added to the bed to permit periods of sitting. Subjects alternated between standing and sitting positions throughout the day. A total of 35% of the day was spent in the standing position and 65% was spent sitting. In an effort to achieve physiologic fluid shifts expected for a 1/6 G environment, subjects wore compression stockings and performed unloaded foot and ankle exercises. Eight subjects (3 females and 5 males) participated in this study. Subjects spent 13 days in the pre-bed rest phase, 6 days in bed rest and 3 days post bed rest. Subjects consumed a standardized diet throughout the study. To determine feasibility, measures of subject comfort, force and plasma volume were collected. Subject comfort was assessed using a Likert scale. Subjects were asked to assess level of comfort (0-100) for 11 body regions and provide an overall rating. Results indicated minimal to no discomfort as most subjects reported scores of zero. Force measures were performed for each standing position and were validated against subject s calculated 1/6 body weight (r(sup 2) = 0.993). The carbon monoxide rebreathing technique was used to assess plasma volume during pre-bed rest and on the last day of bed rest. Plasma volume results indicated a significant decrease (p = 0.001) from pre to post bed rest values. Subjects lost on average 8.3% (sd = 6.1%) during the bed rest phase. Findings from this feasibility study indicated that 1) the lunar analog bed rest model was well tolerated by subjects; 2) a 1/6 load was accurately applied to the z-axis of the body; and 3) plasma volume losses could be achieved in a head-up tilt bed rest model. Future work to refine this model should include extending the duration of bed rest to mimic longer mission durations and a comprehensive assessment of the physiological responses to this bed rest analog.

Cromwell, Ronita L.↗

SCB Quantum Computers Using iSWAP and 1-Qubit Rotations

Units of superconducting circuitry that exploit the concept of the single- Cooper-pair box (SCB) have been built and are undergoing testing as prototypes of logic gates that could, in principle, constitute building blocks of clocked quantum computers. These units utilize quantized charge states as the quantum information-bearing degrees of freedom. An SCB is an artificial two-level quantum system that comprises a nanoscale superconducting electrode connected to a reservoir of Cooper-pair charges via a Josephson junction. The logical quantum states of the device, .0. and .1., are implemented physically as a pair of charge-number states that differ by 2e (where e is the charge of an electron). Typically, some 109 Cooper pairs are involved. Transitions between the logical states are accomplished by tunneling of Cooper pairs through the Josephson junction. Although the two-level system contains a macroscopic number of charges, in the superconducting regime, they behave collectively, as a Bose-Einstein condensate, making possible a coherent superposition of the two logical states. This possibility makes the SCB a candidate for the physical implementation of a qubit. A set of quantum logic operations and the gates that implement them is characterized as universal if, in principle, one can form combinations of the operations in the set to implement any desired quantum computation. To be able to design a practical quantum computer, one must first specify how to decompose any valid quantum computation into a sequence of elementary 1- and 2-qubit quantum gates that are universal and that can be realized in hardware that is feasible to fabricate. Traditionally, the set of universal gates has been taken to be the set of all 1-qubit quantum gates in conjunction with the controlled-NOT (CNOT) gate, which is a 2-qubit gate. Also, it has been known for some time that the SWAP gate, which implements square root of the simple 2-qubit exchange interaction, is as computationally universal as is the CNOT operation.

Williams, Colin↗

SWOT: The Surface Water and Ocean Topography Mission. Wide- Swath Altimetric Elevation on Earth

The elevation of the surface of the ocean and freshwater bodies on land holds key information on many important processes of the Earth System. The elevation of the ocean surface, called ocean surface topography, has been measured by conventional nadirlooking radar altimeter for the past two decades. The data collected have been used for the study of large-scale circulation and sea level change. However, the spatial resolution of the observations has limited the study to scales larger than about 200 km, leaving the smaller scales containing substantial kinetic energy of ocean circulation that is responsible for the flux of heat, dissolved gas and nutrients between the upper and the deep ocean. This flux is important to the understanding of the ocean's role in regulatingfuture climate change.The elevation of the water bodies on land is a key parameter required for the computation of storage and discharge of freshwater in rivers, lakes, and wetlands. Globally, the spatial and temporal variability of water storage and discharge is poorly known due to the lack of well-sampled observations. In situ networks measuring river flows are declining worldwide due to economic and political reasons. Conventional altimeter observations suffers from the complexity of multiple peaks caused by the reflections from water, vegetation canopy and rough topography, resulting in much less valid data over land than over the ocean. Another major limitation is the large inter track distance preventing good coverage of rivers and other water bodies.This document provides descriptions of a new measurement technique using radar interferometry to obtain wide-swath measurement of water elevation at high resolution over both the ocean and land. Making this type of measurement, which addresses the shortcomings of conventional altimetry in both oceanographic and hydrologic applications, is the objective of a mission concept called Surface Water and Ocean Topography (SWOT), which was recommended by the National Research Council's first decadal survey of NASA's Earth science program. This document provides wide-ranging examples of research opportunities in oceanography and land hydrology that would be enabled by the new type of measurement. Additional applications in many other branches of Earth System science ranging from ocean bathymetry to sea ice dynamics are also discussed. Many of the technical issues in making the measurement are discussed as well. Also presented is a preliminary design of the SWOT Mission concept, which is being jointly developed by NASA and CNES, with contributions from the Canadian Space Agency.

altimetry↗

Completion of the Cassini-Huygens Prime Mission

The Cassini-Huygens mission is a joint endeavor between the United States and Europe to conduct an in-depth investigation of the Saturnian system. The agreement between the parties called for conducting operations in orbit at Saturn for a period of four years, and this was completed on July 1, 2008. The mission has been an unqualified success by any measure, and at the time of the completion of the four years, the spacecraft remained in excellent health and with sufficient consumables remaining that a decision has been reached to continue the endeavor for another two years at the same rate of data collection as in the four-year prime mission. This paper provides a high level overview of the mission's accomplishments in the four years, summarizes the current state of the spacecraft, and gives a summary of the plans and expectations for the two additional years of operations at Saturn.

Mitchell, Robert T.↗

Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100μm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

micro-XRF spectrometer↗

Landsat 9 Operational Land Imager2 (OLI2) Diffuser Panel Response Lab Predictions vs. Pre-Launch Measurements

The radiometric calibration of OLI-2 for Landsat 9 uses two types of sources: pre-launch radiance calibrated sphere sources and on-board flight solar diffuser panels. For both calibration articles the instrument contractor, Ball Aerospace Corp. assured the NIST scale transfer via laboratory measurements. The NIST reflectance scale transfer was conducted for the OLI-2 two flight diffusers at the University of Arizona Optical Sciences Center. In this report we present an approach in which the per detector information can be derived for the reflectance panel sources from their BRDF characterization. Using such information enables a cross-check of the as measured reflectance results during the prelaunch diffuser collects illuminated by a Heliostat. This information then enables a derivation of the uncertainty levels to allow assessment of the two radiometric calibration paths agreement.

Raviv Levy↗