Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Wing Shape Sensing from Measured Strain

A new two-step theory is investigated for predicting the deflection and slope of an entire structure using strain measurements at discrete locations. In the first step, a measured strain is fitted using a piecewise least-squares curve fitting method together with the cubic spline technique. These fitted strains are integrated twice to obtain deflection data along the fibers. In the second step, computed deflection along the fibers are combined with a finite element model of the structure in order to interpolate and extrapolate the deflection and slope of the entire structure through the use of the System Equivalent Reduction and Expansion Process. The theory is first validated on a computational model, a cantilevered rectangular plate wing. The theory is then applied to test data from a cantilevered swept-plate wing model. Computed results are compared with finite element results, results using another strain-based method, and photogrammetry data. For the computational model under an aeroelastic load, maximum deflection errors in the fore and aft, lateral, and vertical directions are -3.2 percent, 0.28 percent, and 0.09 percent, respectively; and maximum slope errors in roll and pitch directions are 0.28 percent and -3.2 percent, respectively. For the experimental model, deflection results at the tip are shown to be accurate to within 3.8 percent of the photogrammetry data and are accurate to within 2.2 percent in most cases. In general, excellent matching between target and computed values are accomplished in this study. Future refinement of this theory will allow it to monitor the deflection and health of an entire aircraft in real time, allowing for aerodynamic load computation, active flexible motion control, and active induced drag reduction..

system equivalent reduction and expansion process↗

SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential with different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

Open Rotor Computational Aeroacoustic Analysis with an Immersed Boundary Method

Reliable noise prediction capabilities are essential to enable novel fuel efficient open rotor designs that can meet the community and cabin noise standards. Toward this end, immersed boundary methods have reached a level of maturity where more and more complex flow problems can be tackled with this approach. This paper demonstrates that our higher-order immersed boundary method provides the ability for aeroacoustic analysis of wake-dominated flow fields generated by a contra-rotating open rotor. This is the first of a kind aeroacoustic simulation of an open rotor propulsion system employing an immersed boundary method. In addition to discussing the methodologies of how to apply the immersed boundary method to this moving boundary problem, we will provide a detailed validation of the aeroacoustic analysis approach employing the Launch Ascent and Vehicle Aerodynamics (LAVA) solver. Two free-stream Mach numbers with M=0.2 and M=0.78 are considered in this analysis that are based on the nominally take-off and cruise flow conditions. The simulation data is compared to available experimental data and other computational results employing more conventional CFD methods. Spectral analysis is used to determine the dominant wave propagation pattern in the acoustic near-field.

Analysis↗

Recent Testing of ENDF/B-VIII.0 at ORNL [Slides]

This presentation provides an overview of comparisons of ENDF/B-VII.1 and ENDF/B-VIII.0 and uses VALID suite to test >600 cases with ENDF/B-VII.1 and ENDF/B-VIII.0 in KENO V.a/KENO-VI, although a limited number of cases have been tested with TSUNAMI. It provides a results summary of KENO V.a/KENO-VI with a pooled results summary. The presentation also discusses changes for LCT experiments, MCT experiments, MST experiments, and PST experiments. A few words about graphite are also provided and the presentation states that graphite performance investigated across ENDF/B-VII.0, ENDF/B-VII.1, and ENDF/B-VIII.0 for MSR and HTGR models. A brief summary of the results is presented to make sure the Validation Committee is aware of the work. Also presented is an Eigenvalue comparison with a graphite moderated system, and comparison between an HTR-10 pebble model ENDF/B-VII.1 vs. ENDF/B-VIII.0, which provides different graphite data. In conclusion, ORNL has recently completed a comparison of ENDF/B-VIII.0 and ENDF/B-VII.1 using the VALID library. Work is also being performed for advanced reactor applications. Other efforts on-going and they are also trying to investigate more intermediate spectrum cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancing ACPF Analysis: Integrating Newton-Raphson Method with Gradient Descent and Computational Graphs

This paper presents a new method for enhancing Alternating Current Power Flow (ACPF) analysis. The method integrates the Newton-Raphson (NR) method with Enhanced-Gradient Descent (GD) and computational graphs. The integration of renewable energy sources in power systems introduces variability and unpredictability, and this method addresses these challenges. It leverages the robustness of NR for accurate approximations and the flexibility of GD for handling variable conditions, all without requiring Jacobian matrix inversion. Furthermore, computational graphs provide a structured and visual framework that simplifies and systematizes the application of these methods. The goal of this fusion is to overcome the limitations of traditional ACPF methods and improve the resilience, adaptability, and efficiency of modern power grid analyses. We validate the effectiveness of our advanced algorithm through comprehensive testing on established IEEE benchmark systems. Furthermore, our findings demonstrate that our approach not only speeds up the convergence process but also ensures consistent performance across diverse system states, representing a significant advancement in power flow computation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Absorbing boundary conditions in material point method adopting perfectly matched layer theory

This study focuses on solving the numerical challenges of imposing absorbing boundary conditions for dynamic simulations in the material point method (MPM). To attenuate elastic waves leaving the computational domain, the current work integrates the Perfectly Matched Layer (PML) theory into the implicit MPM framework. The proposed approach introduces absorbing particles surrounding the computational domain that efficiently absorb outgoing waves and reduce reflections, allowing for accurate modeling of wave propagation and its further impact on geotechnical slope stability analysis. The study also includes several benchmark tests to validate the effectiveness of the proposed method, such as several types of impulse loading and symmetric and asymmetric base shaking. The conducted numerical tests also demonstrate the ability to handle large deformation problems, including the failure of elasto-plastic soils under gravity and dynamic excitations. The findings extend the capability of MPM in simulating continuous analysis of earthquake-induced landslides, from shaking to failure.

58 GEOSCIENCES↗

A Clustering-based biased Monte Carlo Approach to Protein Titration Curve Prediction

We develop and implement a novel approach to computing the ensemble averages in systems characterized by pair-wise interactions between the entities. Methods involving full enumeration of the configuration space result in exponential complexity. Sampling methods such as Markov Chain Monte Carlo (MCMC) algorithms have been proposed to tackle the exponential complexity of these problems. In certain scenarios where significant energetic coupling exists between the entities, the accuracy of the such algorithms can be diminished. We propose a strategy to improve the accuracy of the MCMC runs by taking advantage of the cluster structure in the interaction energy matrix. We propose two different schemes for performing the biased MCMC runs on the partitioned systems and show that they are valid MCMC schemes. We then apply these algorithms to the problem of computing the protonation fractions and hence the titration curves of titratable protein residues that constitute a given protein. We leverage both synthesized and real-world systems and show the improved performance of our biased MCMC methods when compared to the regular MCMC method.

Visweswara Sathanur, Arun↗

Comprehensive Silicon-Solar-Cell Program

Comprehensive Silicon Solar Cell Computer Modeling (SICELL) program simulates silicon solar cell. Predicts device parameters as efficiency, voltage-vs.-current characteristic fill factor, and temperature coefficients of parameters. Technique used similar to numerical-integration methods, but commonality described by use of mesh-point field. Validation studies show accuracies of simulations range from 0.08 percent to 3.6 percent for 27 experimental data points over temperature range of 300K to 421K. Results obtained by use of 10 mesh points in n- and p-type regions and for two iterations. SICELL runs interactively on VAX computer under VMS and written in VAX/VMS FORTRAN 77.

Lamorte, Michael F.↗

Boundary coefficient determination for an eddy current problem based on the potential field method

We study a recovery problem for an unknown boundary coefficient relating to one material characteristic in an eddy current field. The field equations are represented in terms of the potential field method (T-ψ method) and can be solved numerically by the nodal finite element method. We introduce a measurement as an additional condition and prove the existence and uniqueness of the weak solution. Further, we present an iteration algorithm for the recovery problem and validate its efficiency by two numerical experiments.

97 MATHEMATICS AND COMPUTING↗

Data Collection Methods for Validation of Advanced Multi-Resolution Fast Reactor Simulations

In pool-type Sodium Fast Reactors (SFR) the regions most susceptible to thermal striping are the upper instrumentation structure (UIS) and the intermediate heat exchanger (IHX). This project experimentally and computationally (CFD) investigated the thermal mixing in the region exiting the reactor core to the UIS. The thermal mixing phenomenon was simulated using two vertical jets at different velocities and temperatures as prototypic of two adjacent channels out of the core. Thermal jet mixing of anticipated flows at different temperatures and velocities were investigated. Velocity profiles are measured throughout the flow region using Ultrasonic Doppler Velocimetry (UDV), and temperatures along the geometric centerline between the jets were recorded using a thermocouple array. CFD simulations, using COMSOL, were used to initially understand the flow, then to design the experimental apparatus and finally to compare simulation results and measurements characterizing the flows. The experimental results and CFD simulations show that the flow field is characterized into three regions with respective transitions, namely, convective mixing, (flow direction) transitional, and post-mixing. Both experiments and CFD simulations support this observation. For the anticipated SFR conditions the flow is momentum dominated and thus thermal mixing is limited due to the short flow length associated from the exit of the core to the bottom of the UIS. This means that there will be thermal striping at any surface where poorly mixed streams impinge; rather unless lateral mixing is ‘actively promoted out of the core, thermal striping will prevail. Furthermore we note that CFD can be considered a ‘separate effects (computational) test’ and is recommended as part of any integral analysis. To this effect, poorly mixed streams then have potential impact on the rest of the SFR design and scaling, especially placement of internal components, such as the IHX that may see poorly mixed streams. Finally, due to lack or infrastructural support for carrying out sodium experiments, only water experiments and CFD studies were realized in, an otherwise sodium approved facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and Validation of the New MCNP6.3 Criticality Features

The MCNP6® code, version 6.3, has been extensively verified and validated for many applications. The use of the same default capabilities existing in the MCNP6.2 code are also used in the verification and validation (V&V) of the MCNP6.3 code. In this paper, selected new features, code enhancements, and bug fixes in the MCNP6.3 code that impact criticality safety applications are described and investigated. More specifically, the changes within the MCNP6.3 code that are studied in this work include both the new fission matrix and the Doppler broadening resonance correction (DBRC) features. For nuclear criticality safety applications, the V&V benchmark problems within the criticality, extended criticality, and Rossi-α suites are used to study the upgrades within the MCNP6.3 code. Some additional investigations into benchmarks at elevated temperatures are used to showcase the impacts of the temperature-specific capabilities.

97 MATHEMATICS AND COMPUTING↗

Simulating NMIS Imaging and Fission-Mapping Measurements

The Nuclear Materials Identification System (NMIS) detects and characterizes fissile and nonfissile materials using time correlations between a time-tagged source and one or more detectors. The first fieldable configuration of dedicated hardware and software was developed in the 1990s. In its original configuration, the measurement system consisted of a time-tagged source and two to four detectors. Measurements with this configuration were easily simulated using a single Monte Carlo run. The present measurement configuration is far more complex than the original. The source is now divided into multiple neutron cones; significantly more detectors are included; and the source, detectors, and object being interrogated can all be moved during the measurement to capture different views of the object. In addition to the hardware changes, the software can now reconstruct high-resolution tomographs of the 14 MeV neutron attenuation coefficients and fission sites inside the object. This work shows how a complex measurement of an object that consists of both fissile and nonfissile parts can be simulated by using multiple input decks and combining the resulting output into the desired format. The results of this simulation were then reconstructed using the imaging and fission-mapping software used with measurements. These reconstructions are consistent with the original model, thus validating the simulation method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bond Line Thickness Estimation in Composite Structures Using Multiple Inspection Techniques

Imaging and other nondestructive evaluation techniques are commonly used for material characterization and defect recognition in safety critical aerospace applications, with data fusion providing the framework for uncertainty quantification in these contexts. Most commonly, forward physics-based modeling predicts the response conditioned on material properties and defect assumptions, and probabilistic methods are used to infer the hidden state of subject of the inspection from a combination of prior information, likelihoods, and inspection data. In this paper Bayesian methods are used to estimate bond thickness in lap joints comprised of aluminum adherends using a combination of infrared thermography, digital radiography, and ultrasound. The accuracy of the fused estimates are validated against data generated from synthetic specimens, and by comparison against high resolution X-ray computed tomography inspections of built specimens.

thermal nondestructive evaluation↗

An efficient method for computing unsteady transonic aerodynamics of swept wings with control surfaces

A transonic equivalent strip (TES) method was further developed for unsteady flow computations of arbitrary wing planforms. The TES method consists of two consecutive correction steps to a given nonlinear code such as LTRAN2; namely, the chordwise mean flow correction and the spanwise phase correction. The computation procedure requires direct pressure input from other computed or measured data. Otherwise, it does not require airfoil shape or grid generation for given planforms. To validate the computed results, four swept wings of various aspect ratios, including those with control surfaces, are selected as computational examples. Overall trends in unsteady pressures are established with those obtained by XTRAN3S codes, Isogai's full potential code and measured data by NLR and RAE. In comparison with these methods, the TES has achieved considerable saving in computer time and reasonable accuracy which suggests immediate industrial applications.

Liu, D. D.↗

Electronic structure of aqueous solutions: Bridging the gap between theory and experiments

Predicting the electronic properties of aqueous liquids has been a long-standing challenge for quantum mechanical methods. However, it is a crucial step in understanding and predicting the key role played by aqueous solutions and electrolytes in a wide variety of emerging energy and environmental technologies, including battery and photoelectrochemical cell design. Here, we propose an efficient and accurate approach to predict the electronic properties of aqueous solutions, on the basis of the combination of first-principles methods and experimental validation using state-of-the-art spectroscopic measurements. We present results of the photoelectron spectra of a broad range of solvated ions, showing that first-principles molecular dynamics simulations and electronic structure calculations using dielectric hybrid functionals provide a quantitative description of the electronic properties of the solvent and solutes, including excitation energies. The proposed computational framework is general and applicable to other liquids, thereby offering great promise in understanding and engineering solutions and liquid electrolytes for a variety of important energy technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomic regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed displacements, acceptable postimplant dosimetry was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗