Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Strain and Magnetization Properties of High Subelement Count Tube-Type Nb3Sn Strands

A tubular technique for economical production of Nb{sub 3}Sn material with large numbers of subelements is being explored by Supergenics I LLC and Hyper Tech Research Inc. The number of subelements was increased to 919 (744 subelements plus 175 Cu filaments) by increasing the size at which restacking is carried out. The product exhibited no fabrication problems and was drawn down and tested at a wire diameter of 0.42 mm, where the subelements are 10 {micro}m in diameter. Recently we increased the subelement number to 1387 (1248 subelements plus 139 Cu filaments), which gives a subelement size of 12 {micro}m in 0.7 mm diameter wires. Heat treatment (HT) of different subelement restacks has been investigated, and the best results of critical current and stability are presented. The strain tolerance of the strands with 192 and 744 subelements was also tested, and the strand with fine subelement size showed a high intrinsic irreversible strain limit.

99 GENERAL AND MISCELLANEOUS↗

Anniversary Paper: Nuclear medicine: Fifty years and still counting

The history, present status, and possible future of nuclear medicine are presented. Beginning with development of the rectilinear scanner and gamma camera, evolution to the present forms of hybrid technology such as single photon emission computed tomography/computed tomography (CT) and positron emission tomography/CT is described. Both imaging and therapy are considered and the recent improvements in dose estimation using hybrid technologies are discussed. Future developments listed include novel radiopharmaceuticals created using short chains of nucleic acids and varieties of nanostructures. Patient-specific radiotherapy is an eventual outcome of this work. Possible application to proving the targeting of potential chemotherapeutics is also indicated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Criteria for projected discovery and exclusion sensitivities of counting experiments

Abstract The projected discovery and exclusion capabilities of particle physics and astrophysics/cosmology experiments are often quantified using the median expected p-value or its corresponding significance. We argue that this criterion leads to flawed results, which for example can counterintuitively project lessened sensitivities if the experiment takes more data or reduces its background. We discuss the merits of several alternatives to the median expected significance, both when the background is known and when it is subject to some uncertainty. We advocate for standard use of the “exact Asimov significance” $$Z^\mathrm{A}$$ Z A detailed in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quark counting rules: old and new approaches

I discuss the subject of powerlike asymptotic behavior of hadronic form factors in pre-QCD analyses of soft (Feynman/Drell-Yan) and hard (West) mechanisms, and also recent derivation of $1/Q^2$ asymptotics of meson form factors in AdS/QCD. At the end, I briefly comment on ``light-front holography' ansatz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing Adaptive Physics Refinement Simulations Through the Addition of Realistic Red Blood Cell Counts

Simulations of cancer cell transport require accurately modeling mm-scale and longer trajectories through a circulatory system containing trillions of deformable red blood cells, whose intercellular interactions require submicron fidelity. Using a hybrid CPU-GPU approach, we extend the advanced physics refinement (APR) method to couple a finely-resolved region of explicitly-modeled red blood cells to a coarsely-resolved bulk fluid domain. We further develop algorithms that: capture the dynamics at the interface of differing viscosities, maintain hematocrit within the cell-filled volume, and move the finely-resolved region and encapsulated cells while tracking an individual cancer cell. Comparison to a fully-resolved fluid-structure interaction model is presented for verification. Finally, we use the advanced APR method to simulate cancer cell transport over a mm-scale distance while maintaining a local region of RBCs, using a fraction of the computational power required to run a fully-resolved model.

Roychowdhury, Sayan↗

A high-density, high-channel count, multiplexed μECoG array for auditory-cortex recordings

Our understanding of the large-scale population dynamics of neural activity is limited, in part, by our inability to record simultaneously from large regions of the cortex. Here, we validated the use of a large-scale active microelectrode array that simultaneously records 196 multiplexed micro-electrocortigraphical (μECoG) signals from the cortical surface at a very high density (1,600 electrodes/cm 2 ). We compared μECoG measurements in auditory cortex using a custom “active” electrode array to those recorded using a conventional “passive” μECoG array. Both of these array responses were also compared with data recorded via intrinsic optical imaging, which is a standard methodology for recording sound-evoked cortical activity. Custom active μECoG arrays generated more veridical representations of the tonotopic organization of the auditory cortex than current commercially available passive μECoG arrays. Furthermore, the cortical representation could be measured efficiently with the active arrays, requiring as little as 13.5 s of neural data acquisition. Next, we generated spectrotemporal receptive fields from the recorded neural activity on the active μECoG array and identified functional organizational principles comparable to those observed using intrinsic metabolic imaging and single-neuron recordings. Furthermore, this new electrode array technology has the potential for large-scale, temporally precise monitoring and mapping of the cortex, without the use of invasive penetrating electrodes.

60 APPLIED LIFE SCIENCES↗

Stochastic analog neutron transport with TRIPOLI-4 and FREYA: Bayesian uncertainty quantification for neutron multiplicity counting

From nuclear safeguards to homeland security applications, the need for the better modeling of nuclear interactions has grown over the past decades. Current Monte Carlo radiation transport codes compute average quantities with great accuracy and performance; however, performance and averaging come at the price of limited interaction-by-interaction modeling. These codes often lack the capability of modeling interactions exactly: for a given collision, energy is not conserved, energies of emitted particles are uncorrelated, and multiplicities of prompt fission neutrons and photons are uncorrelated. Many modern applications require more exclusive quantities than averages, such as the fluctuations in certain observables (e.g., the neutron multiplicity) and correlations between neutrons and photons. In an effort to meet this need, the radiation transport Monte Carlo code TRIPOLI-4® was modified to provide a specific mode that models nuclear interactions in a full analog way, replicating as much as possible the underlying physical process. Furthermore, the computational model FREYA (Fission Reaction Event Yield Algorithm) was coupled with TRIPOLI-4 to model complete fission events. As a result, FREYA automatically includes fluctuations as well as correlations resulting from conservation of energy and momentum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantum-enhanced phase imaging without coincidence counting

Quantitative phase imaging provides a way to image transparent objects, such as biological cells, and measure their thickness. We report on a phase-imaging method that achieves twice the phase shift and approximately 1.7 times the spatial resolution of an equivalent spatially and temporally coherent classical quantitative phase-imaging system by using quantum interference between successive spontaneous parametric downconversion events in a nonlinear crystal. Furthermore, our method is approximately 1000 times faster than imaging the parametric downconversion photons in coincidence, which requires measurement times on the order of tens of hours. Our method may be useful for imaging sensitive transparent objects that require low illumination intensities at near-infrared and longer illumination wavelengths, such as photosensitive biological samples.

47 OTHER INSTRUMENTATION↗

Clicks versus Citations: Click Count as a Metric in High Energy Physics Publishing

High-energy physicists worldwide rely on online resources such as SPIRES and arXiv to perform gather research and share their own publications. SPIRES is a tool designed to search the literature within high-energy physics, while arXiv provides the actual full-text documents of this literature. In high-energy physics, papers are often ranked according to the number of citations they acquire - meaning the number of times a later paper references the original. This paper investigates the correlation between the number of times a paper is clicked in order to be downloaded and the number of citations it receives following the click. It explores how physicists truly read what they cite.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Coincidence Counting Studies

The efficiency comparison for measured and simulated responses of a 10 B-lined proportional counter and a 3 He proportional counter in a close, symmetrical geometry are presented. The measurement geometry was modeled in MCNPX to validate the methods used for simulating the response of both the 3 He and 10 B-lined tubes. The MCNPX models agree within 1% with the 3 He tube measurements and within 3% for the 10 B-lined tubes when a 0.75-µm boron-metal lining is used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗