Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISPLAY DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Facile and low cost oxidative conversion of MoS{sub 2} in α-MoO{sub 3}: Synthesis, characterization and application

This study describes a facile low cost route to synthesize the α-MoO{sub 3} through a conversion of the precursor MoS{sub 2} in oxidant media. The structure and morphology of the α-MoO{sub 3} were studied by high resolution transmission electron microscopy (HRTEM) and selected area electron diffraction (SAED), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy. The results show that α-MoO{sub 3} was obtained with reduced size, high purity, strongly-preferred orientation and structural defects, which ensures versatility and multifunctionality to this sample. For the purpose of applications, α-MoO{sub 3} was successfully employed in inverted organic solar cells devices as a possible alternative to the PEDOT:PSS in the hole transportation layer. - Graphical abstract: Synthesis process based on low cost oxidative conversion of MoS{sub 2} in α-MoO{sub 3} Display Omitted - Highlights: • A facile route to obtain α-MoO{sub 3} by refluxing the MoS{sub 2} precursor in oxidant media. • High purity and strongly-preferred orientation. • Belt-shaped material. • Enhanced conversion efficiency (PCE) when compared with conventional PEDOT:PSS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-performance carbon-nanotube-based complementary field-effect-transistors and integrated circuits with yttrium oxide

High-performance p-type carbon nanotube (CNT) transistors utilizing yttrium oxide as gate dielectric are presented by optimizing oxidization and annealing processes. Complementary metal-oxide-semiconductor (CMOS) field-effect-transistors (FETs) are then fabricated on CNTs, and the p- and n-type devices exhibit symmetrical high performances, especially with low threshold voltage near to zero. The corresponding CMOS CNT inverter is demonstrated to operate at an ultra-low supply voltage down to 0.2 V, while displaying sufficient voltage gain, high noise margin, and low power consumption. Yttrium oxide is proven to be a competitive gate dielectric for constructing high-performance CNT CMOS FETs and integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Blast Overpressure on the Pharmacokinetics of Various Antibiotics in Sprague Dawley Rats

ABSTRACT Introduction Combat injuries are complex and multimodal. Most injuries to the extremities occur because of explosive devices such as improvised explosive devices. Blast exposure dramatically increases the risk of infection in combat wounds, and there is limited available information on the best antibiotic treatments for these injuries. We previously demonstrated that mice exposed to blast displayed a delayed clearance of cefazolin from the plasma and liver; further semi-mechanistic modeling determined that cefazolin concentrations in the skin of these mice were reduced. Our objective was to investigate the effects of blast on the pharmacokinetics of antibiotics of different types used for the treatment of combat wounds in the rat model. Materials and Methods Male Sprague Dawley rats were exposed to blast overpressure followed by injection of a bolus of animal equivalent doses of an antibiotic (cefazolin, cefepime, ertapenem, or clindamycin) into the tail vein at 1-hour post-blast exposure. Blood was collected at predetermined time points via repeated sampling from the tail vein. Animals were also euthanized at predetermined time points, at which time liver, kidney, skin, and blood via cardiac puncture were collected. Antibiotic concentrations were determined by ultra-performance liquid chromatography–tandem mass spectrometry. Results Blast-exposed rats exhibited a similar rate of clearance compared to non-blasted rats in the blood, liver, kidney, and skin, which is inconsistent with the data regarding cefazolin in blast-exposed mice. Conclusions Our results in rats do not recapitulate our previous observation of delayed cefazolin clearance in mice following the blast overpressure exposure. Although using rats permitted us to collect multiple blood samples from the same animals, rats may not be a suitable model for measuring the pharmacokinetics of antibiotics following blast. The interpretation of the results may be challenging because of variation in data among rat subjects in the same sample groups.

General & Internal Medicine↗

Micron-scale measurements of low anisotropic strain response of local $T_c$ in Sr$_2$RuO$_4$

Strontium ruthenate (Sr$_2$RuO$_4$) is a multiband superconductor that displays evidence of topological superconductivity, although a model of the order parameter that is consistent with all experiments remains elusive. We integrated a piezoelectric-based strain apparatus with a scanning superconducting quantum interference device (SQUID) microscope to map the diamagnetic response of single-crystal Sr$_2$RuO$_4$ as a function of temperature, uniaxial pressure, and position with micron-scale spatial resolution. We thereby obtained local measurements of the superconducting transition temperature $T_c$ vs. anisotropic strain $\epsilon$ with sufficient sensitivity for comparison to theoretical models that assume a uniform $p_x\pm ip_y$ order parameter. We found that $T_c$ varies with position and that the locally measured $T_c$ vs. $\epsilon$ curves are quadratic ($T_c\propto\epsilon^2$), as allowed by the C$_4$ symmetry of the crystal lattice. We did not observe the low-strain linear cusp ($T_c\propto \left| \epsilon \right|$) that would be expected for a two-component order parameter such as $p_x\pm ip_y$. Lastly, these results provide new input for models of the order parameter of Sr$_2$RuO$_4$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-I-20: Comprehensive Quality Assurance Test of Second Generation Toshiba Aquilion Large Bore CT Simulator Based On AAPM TG-66 Recommendations

Purpose: AAPM radiation therapy committee task group No. 66 (TG-66) published a report which described a general approach to CT simulator QA. The report outlines the testing procedures and specifications for the evaluation of patient dose, radiation safety, electromechanical components, and image quality for a CT simulator. The purpose of this study is to thoroughly evaluate the performance of a second generation Toshiba Aquilion Large Bore CT simulator with 90 cm bore size (Toshiba, Nasu, JP) based on the TG-66 criteria. The testing procedures and results from this study provide baselines for a routine QA program. Methods: Different measurements and analysis were performed including CTDIvol measurements, alignment and orientation of gantry lasers, orientation of the tabletop with respect to the imaging plane, table movement and indexing accuracy, Scanogram location accuracy, high contrast spatial resolution, low contrast resolution, field uniformity, CT number accuracy, mA linearity and mA reproducibility using a number of different phantoms and measuring devices, such as CTDI phantom, ACR image quality phantom, TG-66 laser QA phantom, pencil ion chamber (Fluke Victoreen) and electrometer (RTI Solidose 400). Results: The CTDI measurements were within 20% of the console displayed values. The alignment and orientation for both gantry laser and tabletop, as well as the table movement and indexing and scanogram location accuracy were within 2mm as specified in TG66. The spatial resolution, low contrast resolution, field uniformity and CT number accuracy were all within ACR’s recommended limits. The mA linearity and reproducibility were both well below the TG66 threshold. Conclusion: The 90 cm bore size second generation Toshiba Aquilion Large Bore CT simulator that comes with 70 cm true FOV can consistently meet various clinical needs. The results demonstrated that this simulator complies with the TG-66 protocol in all aspects including electromechanical component, radiation safety component, and image quality component. Employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-80: A Mobile Application for Intra-Operative Electron Radiotherapy Treatment Planning

Purpose: Intraoperative electron radiotherapy (IORT) poses a unique set of challenges for treatment planning. Planning must be performed in a busy operating room environment over a short timeframe often with little advance knowledge of the treatment depth or applicator size. Furthermore, IORT accelerators can have a large number of possible applicators, requiring extensive databooks that must be searched for the appropriate dosimetric parameters. The goal of this work is to develop a software tool to assist in the planning process that is suited to the challenges faced in the IORT environment. Methods: We developed a mobile application using HTML5 and Javascript that can be deployed to tablet devices suitable for use in the operating room. The user selects the desired treatment parameters cone diameter, bevel angle, and energy (a total of 141 datasets) and desired bolus. The application generates an interactive display that allows the user to dynamically select points on the depth-dose curve and to visualize the shape of the corresponding isodose contours. The user can indicate a prescription isodose line or depth. The software performs a monitor unit calculation and generates a PDF report. Results: We present our application, which is now used routinely in our IORT practice. It has been employed successfully in over 23 cases. The interactivity of the isodose distributions was found to be of particular use to physicians who are less-frequent IORT users, as well as for the education of residents and trainees. Conclusion: This software has served as a useful tool in IORT planning, and demonstrates the need for treatment planning tools that are designed for the specialized challenges encountered in IORT. This software is the subject of a license agreement with the IntraOp Medical Corporation. This software is the subject of a license agreement between Massachusetts General Hospital / Partners Healthcare and the IntraOp Medical Corporation. CLW is consulting on software development with the IntraOp Medical Corporation.

60 APPLIED LIFE SCIENCES↗

ENG 572 Final Report

Thermo-electric coolers (TECs) provide an essential function in many high-powered applications by diverting heat away from a temperature-sensitive load. This summer I have worked with Sandia National Laboratories in exploring the failure mechanisms behind said devices. I have been tasked with determining a plan of action for two TECs manufactured by two different companies labeled A and B respectively. Prior to my involvement in the project, the former has displayed failures during normal operation within its packaging. The latter was subsequently chosen to resolve these issues. Thermal cycling between the extreme expected operating temperatures (-40°C to 80°C) was applied to 5 unmounted TECAs over a period of 5 hours with 1-hour soaks at each extreme. The unmounted TECBs are currently undergoing the same process, and the task is expected to be completed over the next few weeks. The results of the TECA characterization have indicated no failure has occurred, which indicates that failure will need to be induced through either higher temperature extremes or additional mechanical stress.

47 OTHER INSTRUMENTATION↗

An electronic circuit for sensing malfunctions in test instrumentation

Monitoring device differentiates between malfunctions occurring in the system undergoing test and malfunctions within the test instrumentation itself. Electronic circuits in the monitor use transistors to commutate silicon controlled rectifiers by removing the drive voltage, display circuits are then used to monitor multiple discrete lines.

Miller, W. M., Jr.↗

Nondestructive testing of electro thermal devices

This paper describes the results of a recent investigation into 'thermal time constant' nondestructive testing of high reliability electrical fuses. The use of established nondestructive test technology for examining the quality and firing characteristics of electro-explosive devices has been successfully applied to the inspection and prediction of the functional performance of electrical fuses. The technique requires application of a low level current pulse to the electrical fuse with an oscilloscope display of the curve as generated by the temperature coefficient of resistance feedback. The heating curve of temperature vs time is composed of one predominant thermal time constant, which is the product of the test unit's thermal capacity and thermal resistance. It has been found that the quality of the individual electrical fuse, for instance, the relative condition of the critical internal weld or solder joint, can be examined nondestructively.

Earnest, J. E., Jr.↗

A user's guide for DTIZE an interactive digitizing and graphical editing computer program

A guide for DTIZE, a two dimensional digitizing program with graphical editing capability, is presented. DTIZE provides the capability to simultaneously create and display a picture on the display screen. Data descriptions may be permanently saved in three different formats. DTIZE creates the picture graphics in the locator mode, thus inputting one coordinate each time the terminator button is pushed. Graphic input devices (GIN) are also used to select function command menu. These menu commands and the program's interactive prompting sequences provide a complete capability for creating, editing, and permanently recording a graphical picture file. DTIZE is written in FORTRAN IV language for the Tektronix 4081 graphic system utilizing the Plot 80 Distributed Graphics Library (DGL) subroutines. The Tektronix 4953/3954 Graphic Tablet with mouse, pen, or joystick are used as graphics input devices to create picture graphics.

Thomas, C. C.↗

COSMIC monthly progress report

Activities of the Computer Software Management and Information Center (COSMIC) are summarized for the month of May 1994. Tables showing the current inventory of programs available from COSMIC are presented and program processing and evaluation activities are summarized. Nine articles were prepared for publication in the NASA Tech Brief Journal. These articles (included in this report) describe the following software items: (1) WFI - Windowing System for Test and Simulation; (2) HZETRN - A Free Space Radiation Transport and Shielding Program; (3) COMGEN-BEM - Composite Model Generation-Boundary Element Method; (4) IDDS - Interactive Data Display System; (5) CET93/PC - Chemical Equilibrium with Transport Properties, 1993; (6) SDVIC - Sub-pixel Digital Video Image Correlation; (7) TRASYS - Thermal Radiation Analyzer System (HP9000 Series 700/800 Version without NASADIG); (8) NASADIG - NASA Device Independent Graphics Library, Version 6.0 (VAX VMS Version); and (9) NASADIG - NASA Device Independent Graphics Library, Version 6.0 (UNIX Version). Activities in the areas of marketing, customer service, benefits identification, maintenance and support, and dissemination are also described along with a budget summary.

Source record↗

Slow Scan Telemedicine

Originally developed under contract for NASA by Ball Bros. Research Corporation for acquiring visual information from lunar and planetary spacecraft, system uses standard closed circuit camera connected to a device called a scan converter, which slows the stream of images to match an audio circuit, such as a telephone line. Transmitted to its destination, the image is reconverted by another scan converter and displayed on a monitor. In addition to assist scans, technique allows transmission of x-rays, nuclear scans, ultrasonic imagery, thermograms, electrocardiograms or live views of patient. Also allows conferencing and consultation among medical centers, general practitioners, specialists and disease control centers. Commercialized by Colorado Video, Inc., major employment is in business and industry for teleconferencing, cable TV news, transmission of scientific/engineering data, security, information retrieval, insurance claim adjustment, instructional programs, and remote viewing of advertising layouts, real estate, construction sites or products.

Source record↗

NASA Tech Briefs, June 2006

Topics covered include: Magnetic-Field-Response Measurement-Acquisition System; Platform for Testing Robotic Vehicles on Simulated Terrain; Interferometer for Low-Uncertainty Vector Metrology; Rayleigh Scattering for Measuring Flow in a Nozzle Testing Facility; "Virtual Feel" Capaciflectors; FETs Based on Doped Polyaniline/Polyethylene Oxide Fibers; Miniature Housings for Electronics With Standard Interfaces; Integrated Modeling Environment; Modified Recursive Hierarchical Segmentation of Data; Sizing Structures and Predicting Weight of a Spacecraft; Stress Testing of Data-Communication Networks; Framework for Flexible Security in Group Communications; Software for Collaborative Use of Large Interactive Displays; Microsphere Insulation Panels; Single-Wall Carbon Nanotube Anodes for Lithium Cells; Tantalum-Based Ceramics for Refractory Composites; Integral Flexure Mounts for Metal Mirrors for Cryogenic Use; Templates for Fabricating Nanowire/Nanoconduit- Based Devices; Measuring Vapors To Monitor the State of Cure of a Resin; Partial-Vacuum-Gasketed Electrochemical Corrosion Cell; Theodolite Ring Lights; Integrating Terrain Maps Into a Reactive Navigation Strategy; Reducing Centroid Error Through Model-Based Noise Reduction; Adaptive Modeling Language and Its Derivatives; Stable Satellite Orbits for Global Coverage of the Moon; and Low-Cost Propellant Launch From a Tethered Balloon

Source record↗

4D Light Field Imaging System Using Programmable Aperture

Complete depth information can be extracted from analyzing all angles of light rays emanated from a source. However, this angular information is lost in a typical 2D imaging system. In order to record this information, a standard stereo imaging system uses two cameras to obtain information from two view angles. Sometimes, more cameras are used to obtain information from more angles. However, a 4D light field imaging technique can achieve this multiple-camera effect through a single-lens camera. Two methods are available for this: one using a microlens array, and the other using a moving aperture. The moving-aperture method can obtain more complete stereo information. The existing literature suggests a modified liquid crystal panel [LC (liquid crystal) panel, similar to ones commonly used in the display industry] to achieve a moving aperture. However, LC panels cannot withstand harsh environments and are not qualified for spaceflight. In this regard, different hardware is proposed for the moving aperture. A digital micromirror device (DMD) will replace the liquid crystal. This will be qualified for harsh environments for the 4D light field imaging. This will enable an imager to record near-complete stereo information. The approach to building a proof-ofconcept is using existing, or slightly modified, off-the-shelf components. An SLR (single-lens reflex) lens system, which typically has a large aperture for fast imaging, will be modified. The lens system will be arranged so that DMD can be integrated. The shape of aperture will be programmed for single-viewpoint imaging, multiple-viewpoint imaging, and coded aperture imaging. The novelty lies in using a DMD instead of a LC panel to move the apertures for 4D light field imaging. The DMD uses reflecting mirrors, so any light transmission lost (which would be expected from the LC panel) will be minimal. Also, the MEMS-based DMD can withstand higher temperature and pressure fluctuation than a LC panel can. Robotics need near complete stereo images for their autonomous navigation, manipulation, and depth approximation. The imaging system can provide visual feedback

Bae, Youngsam↗

Development and testing of tip devices for horizontal axis wind turbines

A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. The objective was to improve performance by the reduction of tip losses. While power output can always be increased by a simple radial tip extension, such a modification also results in an increased gale load both because of the extra projected area and longer moment arm. Tip devices have the potential to increase power output without such a structural penalty. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbine. The types were a change in tip planform, and a single-element and double-element nonplanar tip extension (winglets). A complete data acquisition system was developed which recorded three wind speed components, ambient pressure, temperature, and turbine output. The system operated unattended and could perform real-time processing of the data, displaying the measured power curve as data accumulated in either a bin sort mode or polynomial curve fit. Approximately 270 hr of perormance data were collected over a three-month period. The sampling interval was 2.4 sec; thrus over 400,000 raw data points were logged. Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. Changes in orientation and angle-of-attack of the winglets were not made. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted.

Gyatt, G. W.↗

The role of surface ligands in quantum-dot devices: Villain or unsung hero?

For over three decades, the study of nanocrystal quantum dots (QDs), which are solution-synthesized nanometer-scale bits of semiconductor materials, has produced singular advances in both our understanding of quantum confinement effects, and in our ability to make use of them in tech-relevant materials. Accordingly, QDs have found their way into the marketplace, specifically as high-performance fluorophores for, e.g., displays and biolabeling. In such applications, optimization of the QD surface, including the passivating ligands, is key to keeping photo-excited carriers from leaving the QD interior before recombining, resulting in a high fluorescence efficiency. Increasingly, attention has turned to realize the promise of QDs for optoelectronic applications (e.g., solar cells, LEDs, sensors) which require charge carriers to controllably enter, exit and/or travel through QDs, a much more challenging problem. In this scenario, the role of the QD surface must be completely reimagined, from being an impenetrable wall to being a gateway, or even a ramp. In this talk, I’ll explore the inherent contrast between QD fluorophore and device applications, and describe how ligands, originally thought only to be impediments to QD electronic devices, may actually give the savvy QD device designer control over function and performance in a manner unknown in bulk semiconductor devices. Finally, I’ll survey recent efforts at Los Alamos to develop a universal tool box for deposition of conductive QD films that may finally allow the manufacturing of economical, high-performance devices for a wide range of applications.

36 MATERIALS SCIENCE↗

Influence of Surface Ligands on Energetics at FASnI 3 /C 60 Interfaces and Their Impact on Photovoltaic Performance

Interfacial chemistry and energetics significantly impact the performance of photovoltaic devices. In the case of Pb-containing organic metal halide perovskites, photoelectron spectroscopy has been used to determine the energetic alignment of frontier electronic energy levels at various interfaces present in the photovoltaic device. For the Sn-containing analogues, which are less toxic, no such measurements have been made. Through a combination of ultraviolet, inverse, and X-ray photoelectron spectroscopy (UPS, IPES, and XPS, respectively) measurements taken at varying thickness increments during stepwise deposition of C 60 on FASnI 3 , we present the first direct measurements of the frontier electronic energy levels across the FASnI 3 /C 60 interface. The results show band bending in both materials and transport gap widening in FASnI 3 at the interface with C 60 . The XPS results show that iodide diffuses into C 60 and results in n-doping of C 60 . This iodide diffusion out of FASnI 3 impacts the valence and conduction band energies of FASnI 3 more than the core levels, with the core level shifts displaying a different trend than the valence and conduction bands. Surface treatment of FASnI 3 with carboxylic acids and bulky ammonium substituted surface ligands results in slight alterations in the interfacial energetics, and all surface ligands result in similar or improved PV performance relative to the untreated devices. Finally, the greatest PV stability results from treatment with a fluorinated carboxylic acid derivative; however, iodide diffusion is still observed to occur with this surface ligand.

interfacial energetics↗

Unraveling the Main Chain and Side Chain Effects on Thin Film Morphology and Charge Transport in Quinoidal Conjugated Polymers

Three series of low-bandgap polymers based on a novel quinoidal para -azaquinodimethane ( p -AQM) unit are devised and synthesized, enabling an in-depth study of the impact of structural factors such as polymer main chain, branching point of the side chain, and the length of the branch chains on the thin film morphologies and charge transport properties. Morphological studies reveal that the polymers composed of larger repeating units exhibit a stronger tendency to form edge-on lamella. In contrast, altering the side chain structures of polymers with the same main chain configuration indicates that the branching point position has a more deterministic impact than the branch chain length on the interchain interactions and the crystallite orientation. These results demonstrate a compound odd-even effect of the branching point on the chain packing and morphology, which correlates well with the corresponding field effect transistor performances. The polymer with the branching point at the fourth carbon displays the highest charge carrier mobility over 1.0 cm 2 V-Three series of low-bandgap polymers based on a novel quinoidal para -azaquinodimethane ( p -AQM) unit are devised and synthesized, enabling an in-depth study of the impact of structural factors such as polymer main chain, branching point of the side chain, and the length of the branch chains on the thin film morphologies and charge transport properties. Morphological studies reveal that the polymers composed of larger repeating units exhibit a stronger tendency to form edge-on lamella. On the other hand, altering the side chain structures of polymers with the same main chain configuration indicates that the branching point position has a more deterministic impact than the branch chain length on the interchain interactions and the crystallite orientation. These results reflect a compound odd-even effect of the branching point on the chain packing and morphology, which correlates well with the corresponding field effect transistor performances. The polymer with the branching point at the fourth carbon displays the highest charge carrier mobility over 1.0 cm 2 V -1 s -1 , concurrent with a bimodal texture. This study provides a comprehensive description of the correlations between polymer structures, thin film morphology, and device performances, providing a clear path to desirable bimodal thin film texture for charge transport.

36 MATERIALS SCIENCE↗