Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Anomaly Detection in DUNE FD LArTPC Readouts

We designed and built an AI/ML model to detect anomalies in the DUNE far detector data. The model has been trained on simulated radiological background (rbkg) data, which is the major background for supernova burst neutrinos that we want to detect as anomaly in thios work. The trained model was evaluated on both new samples of radiological backgrounds and supernova burst neutrino events in the elastic scattering and charged current interaction channels. We found that the trained model can successfully identify supernova burst neutrino events as anomalies while identifying radiological backgrounds as nominal events.

Novello, Eric [Fermilab]↗

Antenna-coupled TES bolometers used in BICEP2, Keck Array, and Spider

We have developed antenna-coupled transition-edge sensor bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including Bicep2, Keck Array, and the balloon borne Spider. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%–30% bandwidth at 95, 150, or 230 GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ∼0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET ∼ 300 μK{sub CMB}√s. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ∼9 μK{sub CMB}√s, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the Spider instrument, and development of this technology is ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the engineering run of the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)

The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW(th) nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed around the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The in-situ calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor ON and OFF are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below 2 e – RMS and stable background rates. In conclusion, the success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CMS hadron calorimeter front-end upgrade for SLHC phase I

We present an upgrade plan for the CMS HCAL detector. The HCAL upgrade is required for the increased luminosity (3 * 10E34) of SLHC Phase I which is targeted for 2014. A key aspect of the HCAL upgrade is to add longitudinal segmentation to improve background rejection, energy resolution, and electron isolation at the L1 trigger. The increased segmentation is achieved by replacing the hybrid photodiodes (HPDs) with silicon PMTs (SIPMs). We plan to instrument each fiber of the calorimeter with an SIPM (103,000 total). We will then electrically sum outputs from selected SIPMs to form the longitudinal readout segments. In addition to having more longitudinal information, the upgrade plans include a new custom ADC with matched sensitivity and timing information. The increased data volume requires higher speed transmitters and the additional power dissipation for the readout electronics requires better thermal design, since much of the on-detector infrastructure (front-end electronics crates, cooling pipes, optical fiber plant, etc.) will remain the same. We will report on the preliminary designs for these upgraded systems, along with performance requirements and initial design studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a FELIX based readout system for ITk strip hybrid module demonstrator for ATLAS Phase-II Upgrade

The Large Hadron Collider (LHC) will undergo a major upgrade around 2024 with a roughly tenfold increase in luminosity. It results in corresponding increases in particle rates and radiation doses that the current ATLAS Inner Tracking Detector cannot cope with. Therefore the ATLAS experiment will build a new all-silicon tracking system called the ITk (Inner Tracker) that includes an inside pixel detector close to the beam line and a strip detector in outside layer. Meanwhile the ATLAS experiment will adopt the Front-End Link eXchange (FELIX) system as the interface between the data acquisition and front-end electronics for all sub-detectors in the Phase II Upgrade. In this contribution, we present a prototype of FELIX based readout system for the strip hybrid module. Its hardware, firmware and software GUI application will be discussed, as well as integration test results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of the 4th Concept Detector

For the support of a new technology high energy collider ("4th") for potential use at a new lepton collider. In addition, support for dual-readout calorimetry, CERN RD52.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light propagation in a neutron detector based on 6 Li glass scintillator particles in an organic matrix

Composite materials consisting of 6 Li scintillator particles in an organic matrix can enable thermal neutron detectors with excellent rejection of gamma-ray backgrounds. The efficiency of transporting scintillation light through such a composite is critical to the detector performance. This optical raytracing study of a composite thermal neutron detector quantifies the various sources of scintillation light loss and identifies favorable photomultiplier tube (PMT) readout schemes. The composite material consisted of scintillator cubes within an organic matrix shaped as a right cylinder. The cylinder surface was surrounded by an optical reflector, and the light was detected by PMTs attached to the cylinder end faces. A reflector in direct contact with the composite caused 53% loss of scintillation light. This loss was reduced 8-fold by creating an air gap between the composite and the reflector to allow a fraction of the scintillation light to propagate by total internal reflection. Replacing a liquid mineral oil matrix with a solid acrylic matrix decreased the light transport efficiency by only ~10% for the benefit of creating an all-solid-state device. The light propagation loss was found to scale exponentially with the distance between the scintillation event and the PMT along the cylinder main axis. This enabled a PMT readout scheme that corrects for light propagation loss on an event-by-event basis and achieved a 4.0% energy resolution that approached Poisson-limited performance. These results demonstrate that composite materials can enable practical thermal neutron detectors for a wide range of nuclear non-proliferation and safeguard applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forward Pixel Detector for the Phase 2 Upgrade of CMS And Module Testing at UIC

High-Luminosity Large Hadron Collider (HL-LHC) upgrade aims to increase performance. In order to efficiently handle the larger particle flux and increased radiation, an upgrade is planned for the inner Tracker of the Compact Muon Solenoid (CMS) detector, which is located at the innermost part of the CMS. To efficiently reconstruct and track particles, the existing pixel tracker will be upgraded with novel sensors, readout chips, and front-end electronics designed to handle increased data rates. These improvements will allow the detector to track particles more precisely. In the United States, we are working on assembling new sensor modules to be inserted into disks, referred to as TFPX, for installation in the CMS detector for the HL-LHC era. We are currently testing the prototype of TFPX modules to ensure the upgrade is carried out in the best way possible. The University of Ilinois Chicago has been tasked with testing the final versions of the TFPX sensor modules before they are sent to CERN to be installed into the CMS detector. This work is supported by NSF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. Lastly, we detail the characteristics, operation, testing and application of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of an intensified CCD detector for the Solar and Heliospheric Observatory

An engineering model intensified CCD detector for the SOHO Coronal Diagnostics Spectrometer has been built and tested at the NASA Goddard Space Flight Center. A windowless MCP intensifier tube converts EUV radiation (30-65 nm) into visible light, which is focused via a lens system onto a Tektronix 1024 x 1024 CCD. Tests have been made of this engineering model to determine the following characteristics: quantum efficiency, resolution, throughput, linearity, statistical variation, readout noise, scattering, and flat-field response. In almost all respects, the detector performed as expected. This detector has been delivered, and work is underway on the flight detector.

Thompson, William T.↗

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

Here, we present results from a 3.25 kg–day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ~7 events per kg-day and electron-equivalent energies of ~80 eV, whose origin remains unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing and Modeling the Influence of Geometry on the Performance of Superconducting Nanowire Cryotrons

The scaling of superconducting nanowire detectors to larger arrays is often limited by room-temperature-readout cabling. Cryogenic integrated circuits constructed from nanowire cryotrons, or nanocryotrons, can address this limitation by performing signal processing on chip. In this study, we characterize key performance metrics of the nanocryotron to elucidate its potential as a logical element in cryogenic integrated circuits and develop an electro-thermal model to connect material parameters with device performance. We find that the performance of the nanocryotron depends on the device geometry, and trade-offs are associated with optimizing the gain, jitter, and energy dissipation. Here, we demonstrate that nanocryotrons fabricated on niobium nitride can achieve a grey zone less than 210 nA wide for a 5 ns long input pulse corresponding to a maximum achievable gain of 48 dB, an energy dissipation of less than 20 aJ per operation, and a jitter of less than 60 ps.

Superconductor↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

Development of a 1K x 1K GaAs QWIP Far IR Imaging Array

In the on-going evolution of GaAs Quantum Well Infrared Photodetectors (QWIPs) we have developed a 1,024 x 1,024 (1K x1K), 8.4-9 microns infrared focal plane array (FPA). This 1 megapixel detector array is a hybrid using the Rockwell TCM 8050 silicon readout integrated circuit (ROIC) bump bonded to a GaAs QWIP array fabricated jointly by engineers at the Goddard Space Flight Center (GSFC) and the Army Research Laboratory (ARL). The finished hybrid is thinned at the Jet Propulsion Lab. Prior to this development the largest format array was a 512 x 640 FPA. We have integrated the 1K x 1K array into an imaging camera system and performed tests over the 40K-90K temperature range achieving BLIP performance at an operating temperature of 76K (f/2 camera system). The GaAs array is relatively easy to fabricate once the superlattice structure of the quantum wells has been defined and grown. The overall arrays costs are currently dominated by the costs associated with the silicon readout since the GaAs array fabrication is based on high yield, well-established GaAs processing capabilities. In this paper we will present the first results of our 1K x 1K QWIP array development including fabrication methodology, test data and our imaging results.

Jhabvala, M.↗

Delta-doped hybrid advanced detector for low energy particle detection

A delta-doped hybrid advanced detector (HAD) is provided which combines at least four types of technologies to create a detector for energetic particles ranging in energy from hundreds of electron volts (eV) to beyond several million eV. The detector is sensitive to photons from visible light to X-rays. The detector is highly energy-sensitive from approximately 10 keV down to hundreds of eV. The detector operates with milliwatt power dissipation, and allows non-sequential readout of the array, enabling various advanced readout schemes.

Cunningham, Thomas J.↗