Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Protein Crystal Movements and Fluid Flows During Microgravity Growth

The growth of protein crystals suitable for x-ray crystal structure analysis is an important topic. The quality (perfection) of protein crystals is now being evaluated by mosaicity analysis (rocking curves) and x-ray topographic images as well as the diffraction resolution limit and overall data quality. In yet another study, use of hanging drop vapour diffusion geometry on the IML-2 shuttle mission showed, again via CCD video monitoring, growing apocrustacyanin C(sub 1) protein crystal executing near cyclic movement, reminiscent of Marangoni convection flow of fluid, the crystals serving as "markers" of the fluid flow. A review is given here of existing results and experience over several microgravity missions. Some comment is given on gel protein crystal growth in attempts to 'mimic' the benefits of microgravity on Earth. Finally, the recent new results from our experiments on the shuttle mission LMS are described. These results include CCD video as well as interferometry during the mission, followed, on return to Earth, by reciprocal space mapping at the NSLS, Brookhaven, and full X-ray data collection on LMS and Earth control lysozyme crystals. Diffraction data recorded from LMS and ground control apocrustacyanin C(sub 1) crystals are also described.

Boggon, Titus J.↗

Crystallization of Chicken Egg White Lysozyme from Assorted Sulfate Salts

Chicken egg white lysozyme has been found to crystallize from ammonium, sodium, potassium, rubidium, magnesium, and manganese sulfates at acidic and basic pH, with protein concentrations from 60 to 190 mg/ml. Crystals have also been grown at 4 C in the absence of any other added salts using isoionic lysozyme which was titrated to pH 4.6 with dilute sulfuric acid. Four different crystal forms have been obtained, depending upon the temperature, protein concentration, and precipitating salt employed. Crystals grown at 15 C were generally tetragonal, with space group P4(sub 3)2(sub 1)2. Crystallization at 20 C typically resulted in the formation of orthorhombic crystals, space group P2(sub 1)2(sub 1)2(sub 1). The tetragonal reversible reaction orthorhombic transition appeared to be a function of both the temperature and protein concentration, occurring between 15 and 20 C and between 100 and 125 mg/ml protein concentration. Crystallization from 1.2 M magnesium sulfate at pH 7.8 gave a trigonal crystal, space group P3(sub 1)2(sub 1), a = b = 87.4, c = 73.7, gamma = 120 deg, which diffracted to 2.8 A. Crystallization from ammonium sulfate at pH 4.6, generally at lower temperatures, was also found to result in a monoclinic form. space group C2, a = 65.6, b = 95.0, c = 41.2, beta = 119.2 deg. A crystal of approximately 0.2 x 0.2 x 0.5 mm grown from bulk solution diffracted to approximately 3.5 A.

Forsythe, Elizabeth L.↗

A Critical Assessment of Protein Crystal Growth in Microgravity

Experiments to grow higher diffraction quality protein crystals in the microgravity environment of an orbiting spacecraft are one of the most frequently flown space experiments. Ground-based research has shown that convective flows occur even about protein crystals growing in the Earth's gravitational field. Further, this research has shown that the resultant flow velocities can cause growth cessation, and probably affect the measured X-ray data quality obtained. How flow deleteriously affects protein crystal growth (PCG) is still not known, and is the subject of ongoing research. Failing a rational method for ameliorating flow effects on Earth, one can, through NASA and other nations space agency sponsored programs, carry out protein crystal growth in the microgravity environment of an orbiting spacecraft. Early first generation PCG hardware was characterized by a very low success rate and a steep design learning curve. Subsequent hardware designs have improved upon their predecessors. Now the crystal grower has a wide variety of hardware configurations and crystal growth protocols to choose from, many of which implement "standard" laboratory protein crystal growth methods. While many of these are first or early second generation hardware the success rate, defined as growing crystals giving data better than has been obtained on Earth, is at least 20% overall and may be considerably higher if one only considers latter experiments. There are a large number of protein crystals grown every year, with hundreds of structures determined. Those crystallized in microgravity represent a small proportion of this total, and there is concern that the costs of the microgravity PCG program(s) do not justify such limited returns. Empirical evidence suggests that optimum crystal growth conditions in microgravity differ from those determined on Earth, further exacerbating the chances of success. Microgravity PCG is probably best suited for "mature" crystallizations, where one has considerable experience with the particular macromolecular system and has reached an apparent limit in diffraction resolution. Under such circumstances the cost of one or two successful flight experiments may more than offset the equivalent cost of several years effort to obtain the same improvement in data quality.

Pusey, Marc↗

Protein Crystal Movements and Fluid Flows During Microgravity Growth

The growth of protein crystals suitable for X-ray crystal structure analysis is an important topic. The methods of protein crystal growth are under increasing study whereby different methods are being compared via diagnostic monitoring including Charge Coupled Device (CCD) video and interferometry. The quality (perfection) of protein crystals is now being evaluated by mosaicity analysis (rocking curves) and X-ray topographic images as well as the diffraction resolution limit and overall data quality. Choice of a liquid-liquid linear crystal growth geometry and microgravity can yield a spatial stability of growing crystals and fluid, as seen in protein crystallization experiments on the unmanned platform EURICA. A review is given here of existing results and experience over several microgravity missions. The results include CCD video as well as interferometry during the mission, followed, on return to earth, by rocking curve experiments and full X-ray data collection on LMS and earth control lysozyme crystals. Diffraction data recorded from LMS and ground control apocrustacyanin C(sub 1) crystals are also described.

Boggon, Titus J.↗

Crystal Chemistry of Melanite Garnet

This original project resulted in a detailed crystal chemical data map of a titanium rich garnet (melanite) suite that originates from the Crowsnest Volcanics of Alberta Canada. Garnet is typically present during the partial melting of the earth's mantle to produce basalt. Prior studies conducted at Youngstown State University have yielded questions as to the crystal structure of the melanite. In the Studies conducted at Youngstown State University, through the use of single crystal x-ray diffraction, the c-axis appears to be distorted creating a tetragonal crystal instead of the typical cubic crystal of garnets. The micro probe was used on the same suite of titanium rich garnets as used in the single crystal x-ray diffraction. The combination of the single crystal x-ray research and the detailed microprobe research will allow us to determine the exact crystal chemical structure of the melanite garnet. The crystal chemical data was gathered through the utilization of the SX100 Electron Probe Micro Analyzer. Determination of the exact chemical nature may prove useful in modeling the ultramafic source rock responsible for the formation of the titanium rich lunar basalts.

Nguyen, Dawn Marie↗

Searching for the Best Protein Crystals: Synchrotron Based Measurements of Protein Crystal Quality

We are developing X-ray diffraction methods to quantitatively evaluate the quality of protein crystals. The ultimate use for these crystal quality will be to optimize crystal growth and freezing conditions to obtain the best diffraction data. We have combined super fine-phi slicing with highly monochromatic, low divergence synchrotron radiation and the ADSC Quantum 4 CCD detector at the Stanford Synchrotron Radiation laboratory beamline 1.5 to accurately measure crystal mosaicity. Comparisons of microgravity versus earth-grown insulin crystals using these methods will be presented.

Borgstahl, Gloria↗

Angular Broadening: Effects of Nonzero, Spatially Varying Plasma Frequency Between the Source and Observer

Angular broadening of radiation due to scattering by density irregularities is usually described using geometric optics (GO) or the parabolic wave equation (PWE) with the assumptions that the radiation frequency f greatly exceeds the local plasma frequency f(sub p0) or that f(sub p0)/f is constant along the path. These assumptions are inappropriate for many solar system radio phenomena. Here the PWE and GO formalisms are extended to treat angular broadening in plasmas with nonzero, spatially varying ratios, f(sub p0)(z)/f < 1. The new PWE results show that the correlation function, scattered angular spectrum, and other quantities are modified by inclusion of a denominator factor [1 - f(sup 2, sub p0)(z prime)/f prime] inside the path integral over z prime, while the mean-square scattering angle depends on both f(sub p0)(z)/f at the observer and the foregoing factor inside the path integral. The PWE and GO predictions for are identical and involve equivalent assumptions. Previous GO and PWE results are recovered in the limits that f(sub p0)(z prime)/f is constant or zero. The new PWE and GO results will permit more accurate calculation of angular broadening for solar system and astrophysical sources. Moreover and importantly, due to the PWE and GO results for being identical, previous GO analyses of in solar system contexts are essentially correct, except for the neglect of or minor deficiencies in the treatment of nonzero, spatially varying f(sub p0)/f effects. The identical GO and PWE results for and the form of the PWE equation for the correlation function raise questions as to whether diffraction is unimportant for angular broadening (under the usual PWE conditions). Future direct comparisons of the PWE predictions with angular spectra calculated using existing GO ray-tracing codes should answer these questions. Diffraction effects are probably important when the medium and turbulence are not sufficiently homogeneous transverse to the central ray path. The implications are also discussed for studies of the 2-3.5 kHz radiation observed in the outer heliosphere.

Cairns, Iver H.↗

The Effect of Solution Parameters on Lysozyme Nucleation Rates and Crystal Quality

In the pursuit of strongly diffracting high quality macromolecule crystals of suitable volume, this study investigates how the formation of macromolecules in solution and their growth characteristics effect crystal volume and diffracting quality. We systematically investigated the effect of solution conditions on lysozyme nucleation rates and the volume of crystals produced. Batch crystallization plates were used in combination with a video microscope system to measure nucleation rates and crystal volume. As expected from classical nucleation theory, crystal numbers were found to increase with increases in temperature and supersaturation. Small changes in solution pH, at constant supersaturation values were found, however, to dramatically effect the number of crystals nucleated in the wells varying from 1000s to 10s in the pH range 4.0 to 5.2. Having optimized the conditions required to produce an appropriate number of crystals of a suitable volume for X-ray analysis, a large number of uniform crystals were produced under exactly the same conditions. In the X-ray analysis of more than 50 such crystals there was found a wide variation in crystal lattice parameters and data quality. The variation in X-ray quality crystal samples is thought to be related to the growth rate variation caused by growth rate dispersion seen in lysozyme crystal growth experiments.

Judge, R. A.↗

Macromolecule Crystal Quality Improvement in Microgravity: The Role of Impurities

While macromolecule impurities may affect crystal size and morphology the over-riding question is; "How do macromolecule impurities effect crystal X-ray quality and diffraction resolution?" In the case of chicken egg white lysozyme, crystals can be grown in the presence of a number of impurities without affecting diffraction resolution. One impurity however, the lysozyme dimer, does negatively impact the X-ray crystal properties. Crystal quality improvement as a result of better partitioning of this impurity during crystallization in microgravity has been reported'. In our recent experimental work dimer partitioning was found to be not significantly different between the two environments. Mosaicity analysis of pure crystals showed a reduced mosaicity and increased signal to noise for the microgravity grown crystals. Dimer incorporation however, did greatly reduce the resolution limit in both ground and microgravity grown crystals. These results indicate that impurity effects in microgravity are complex and may rely on the conditions or techniques employed.

Judge, Russell A.↗

Recent Trends in the Analysis of Quasioptical Systems

The recent trend in microwave instruments is the use of multiple millimeter and submillimeter wavelength bands. These systems are typically analyzed by using physical optics, Gaussian beams or ray tracing techniques. Physical optics offers high accuracy at the expense of computation time. This trade-off becomes particularly apparent in the analysis of multiple reflector antennas, such as beam waveguide antennas, where physical optics is used to compute the current on each reflector from the current on the previous reflector. At the other end of the spectrum is ray tracing approaches that ignore diffraction effects entirely. These methods are fast but sacrifice the ability to predict some effects accurately. An intermediate approach is to use an appropriate set of expansion functions to model the field between the reflectors. If the set is chosen wisely only a few coefficients need to be determined from each reflector current. The field is then computed at the next reflector through the use of the expansion functions and their coefficients rather than by using the previous reflector current. For a beam waveguide system with no enclosing tubes an excellent set of expansion functions is the Gaussian beam mode set. In many cases a preliminary design which includes the effects on diffraction may be obtained by considering only the fundamental mode and a thin lens model for the reflectors. Higher-order modes are included to model the effects of the curved reflector, which include asymmetric distortion of the beam, cross polarization, and beam truncation. This paper describes a computer code implementing higher-order Gaussian beam scattering by multiple reflector systems. There are four essential steps in the algorithm. (1) Compute the current on the first reflector using physical optics using either a feed model or by an incident set of Gaussian beam modes. (2) Find the direction of propagation for the reflected Gaussian beam-set using ray tracing. (3) Determine the waist size and location for the output beam set by examining the amplitude and phase distribution of the current on the reflector. (4) Compute the amplitudes of the individual modes in the output mode set. These steps are then repeated for each addition reflector in the chain. In each of these cases the previous Gaussian beam set provides the input field for the current calculation. Details of the four steps discussed above will be discussed. Examples will compare results from the Gaussian beam approach to pure physical optics, illustrating both its merits and limitations. Hybrid approaches capable of eliminating some of the limitations will also be discussed.

Hoppe, D. J.↗

The Question of Impurities in Macromolecule Crystal Quality Improvement in Microgravity

While macromolecule impurities may affect crystal size and morphology the over-riding question is how do macromolecule impurities effect crystal X-ray quality and diffraction resolution. In the case of chicken egg white lysozyme previous researchers have reported that crystals grown in the presence of ovalbumin, ovotransferrin, and turkey egg white lysozyme show no difference in diffraction resolution compared to those grown in pure solutions. One impurity however, a naturally occurring lysozyme dimer, does negatively impact the X-ray crystal properties. For this impurity it has been reported that crystal quality improvement in microgravity may be due to improved impurity partitioning during crystallization. In this study we have examined the incorporation of the dimer into lysozyme crystals, both on the ground and in microgravity experiments, and have performed detailed X-ray analysis of the crystals using a new technique for finely probing the mosaicity of the crystal at the Stanford Synchrotron Radiation Laboratory. Dimer partitioning was not significantly different in microgravity compared to the ground based experiments, although it is significantly better than that previously reported in microgravity. Mosaicity analysis of pure crystals, 1422 indexed reflections (microgravity) and 752 indexed reflections (ground), gave average results of 0.0066 and 0.0092 degrees (FWHM) respectively. The microgravity crystals also provided an increased signal to noise. Dimer incorporation increased the average mosaicity in microgravity but not on the ground. However, dimer incorporation did greatly reduce the resolution limit in both ground and microgravity grown crystals. The data is being treated anisotropically to explore these effects. These results indicate that impurity effects in microgravity are complex and that the conditions or techniques employed may greatly affect the role of impurities.

Judge, Russell A.↗

Freely Suspended Smectic Filaments and the Structure of the B7 Phase of MHOBOW

Our recent discovery of the spontaneous formation of chiral domains in fluid smectic phases of achiral bow-shaped molecules opens up a wide variety of possibilities for new liquid crystal phases and phenomena. The basic, spontaneously chiral layer structure of the highest temperature fluid smectic phases, the B2 and B7, are shown. One of the most intriguing aspects of this structure is the plethora of possible phases coming from different stacking sequences of the polar ordering and tilt directions. The four possibilities of next-nearest neighbor alternation are shown. In the original material studied, NOBOW, the ground states found are antiferroelectric, either the racemic SmC(sub S)P(sub A) or the chiral SmC(sub A)P(sub A). We are currently studying MHOBOW, synthesized by D. Walba which, by virtue of its methyl hexyloxy tail has a tendency to form anticlinic layer interfaces, in the hope of finding a phase with a ferroelectric ground state, either SmC(sub A)P(sub S) or SmC(sub S)P(sub A), which can be obtained in NOBOW only by applying a field. Preliminary observations of MHO-BOW have made its study, from the point of view of understanding novel LC structures, extremely high priority. The following truly remarkable characteristics have been revealed: (i) The smectic phase grows out of the isotropic in the form of helical ribbons. The resulting planar aligned textures of focal conics with layers normal to glass plates exhibit bizarre modulations, including stripes and checker-boards. These have also been seen in other materials suggesting that this is a new phase (tentatively called B7), which is a fluid smectic with some kind of in-layer structure. (ii) It is virtually impossible to make freely suspended films of MHOBOW. Rather it makes the freely suspended filaments which preliminary x-ray scattering experiments reveal to have the nested cylinder layer structure indicated; (iii) The powder x-ray diffraction exhibits four resolution-limited smectic layering peaks, very close in layer spacing, which vary continuously with T. This is further evidence for a more complex three dimensional structure than NOBOW, which has a typical single layering reflection. (iv) The x-ray structure factor of the layering peak of the filaments is extraordinarily complex and rich. Varying in qL (the scattering vector component along the filament axis) from a double slit-like pattern to modulated layer-like patterns, as qH (the scattering vector component normal to the filament axis) is varied over the range where the four powder peaks are located. These results suggest some kind of mosaic structure, perhaps with different layer spacings corresponding to the different stacking sequences. Recent x-ray diffraction experiments show that the peaks are modulated in intensity upon translation along a filament, in domains of several hundred microns dimension. These preliminary experiments suggest that the B7 is a fluid smectic with extremely unusual and fascinating structures. Of all of the many hundreds of fluid smectic materials we have attempted to study in the freely suspended film geometry over the years, only a few have failed to form films, and none showed any great tendency to form filaments, although this clearly should be a possible freely suspended smectic LC morphology. On several occasions in the past we have intentionally tried to make filaments from a variety of smectics without success. Thus the smectic filament formation property makes the B7 phase unique. It seems quite likely that the stability of filaments is related to the in-plane structure. The filaments exhibit other interesting structural and optical features. They are birefringent with a local optic axis which is oblique and which can vary continuously along filament and which can be manipulated with an electric field applied normal to the fiber, as if the field were causing a rotation of the optic axis about the fiber axis. Rapid displacement of the ends of the fiber toward one another causes a macroscopic helixing at low T and causes thick regions to transiently appear at high T, a 1D analog of island formation on a rapidly compressed film.

Clark, N.↗

Measurements and Diagnostics of Diamond Films and Coatings

The commercial potential of chemical-vapor-deposited (CVD) diamond films has been established and a number of applications have been identified through university, industry, and government research studies. This paper discusses the methodologies used for property measurement and diagnostic of CVD diamond films and coatings. Measurement and diagnostic techniques studied include scanning electron microscopy, transmission electron microscopy, atomic force microscopy, stylus profilometry, x-ray diffraction, electron diffraction, Raman spectroscopy, Rutherford backscattering, elastic recoil spectroscopy, and friction examination. Each measurement and diagnostic technique provides unique information. A combination of techniques can provide the technical information required to understand the quality and properties of CVD diamond films, which are important to their application in specific component systems and environments. In this study the combination of measurement and diagnostic techniques was successfully applied to correlate deposition parameters and resultant diamond film composition, crystallinity, grain size, surface roughness, and coefficient of friction.

Miyoshi, Kazuhisa↗

Adjustable Focus Optical Correction Lens (AFOCL)

This report describes the activities and accomplishments along with the status of the characterization of a PLZT-based Adjustable Focus Optical Correction Lens (AFOCL) test device. The activities described in this report were undertaken by members of the Center for Applied Optics (CAO) at the University of Alabama in Huntsville (UAH) under NASA Contract NAS8-00188. The effort was led by Dr. Bruce Peters as the Principal Investigator and supported by Dr. Patrick Reardon, Ms. Deborah Bailey, and graduate student Mr. Jeremy Wong. The activities outlined for the first year of the contract were to identify vendors and procure a test device along with performing the initial optical characterization of the test device. This activity has been successfully executed and test results are available and preliminary information was published at the SPIE Photonics West Conference in San Jose, January 2001. The paper, "Preliminary investigation of an active PLZT lens," was well received and generated response with several questions from the audience. A PLZT test device has been commercially procured from an outside vendor: The University of California in San Diego (UCSD) in partnership with New Interconnect Packaging Technologies (NIPT) Inc. The device has been subjected to several tests to characterize the optical performance of the device at wavelengths of interest. The goal was to evaluate the AFOCL similar to a conventional lens and measure any optical aberrations present due to the PLZT material as a deviation in the size of the diffraction limited spot (blur), the presence of diffracted energy into higher orders surrounding the focused spot (a variation in Strehl), and/or a variation or spread in the location of the focused energy away from the optical axis (a bias towards optical wedge, spherical, comma, or other higher order aberrations). While data has been collected indicative of the imaging quality of the AFOCL test device, it was not possible to fully characterize the optical performance of the AFOCL alone because there were significant optical distortions due to fabrication related issues.

Peters, Bruce R.↗

X-Ray Characterization of Structural Defects in Seeded and Self-Seeded ZnSe Crystal Grown by PVT in Horizontal and Vertical Configurations

As part of a pre-flight ground based investigation of crystal growth of II-VI compound semiconductors, a number of ZnSe boules have been grown by physical vapor transport (PVT) at Marshall Space Flight Center. Boules were grown in both horizontal and vertical configurations and seeded and self-seeded growth techniques were employed. As-grown and/or cleaved boules were examined by a combination of synchrotron white beam x-ray topography (SWBXT) and high resolution triple axis diffraction (HRTXD) to characterized the structural defects and correlate them with the growth conditions. Horizontal grown boules tend to grow away from the ampoule wall (contactless growth) and generally exhibit large (110) facets parallel to the gravity vector. Vertical grown boules grew to the full diameter of the ampoule and exhibited no faceting. X-ray topography combined with back reflection x-ray diffraction revealed the presence of lamellar twins (180 deg type about the [111] axis) in horizontal grown boules while vertically grown boules contain a few large grains, some of which are twinned. X-ray topographs and reciprocal space maps recorded from the boules show the better crystal quality of horizontal grown boules. The relationship between crystal quality and gravity vector is investigated. Further, an attempt is made to extend the Hurle theory of twin nucleation in Czochralski grown crystals to explain the twinning mechanisms in horizontal grown boules.

Raghothamachar, B.↗

A Test of Macromolecular Crystallization in Microgravity: Large, Well-Ordered Insulin Crystals

Crystals of insulin grown in microgravity on space shuttle mission STS-95 were extremely well-ordered and unusually large (many > 2 mm). The physical characteristics of six microgravity and six earth-grown crystals were examined by X-ray analysis employing superfine f slicing and unfocused synchrotron radiation. This experimental setup allowed hundreds of reflections to be precisely examined for each crystal in a short period of time. The microgravity crystals were on average 34 times larger, had 7 times lower mosaicity, had 54 times higher reflection peak heights and diffracted to significantly higher resolution than their earth grown counterparts. A single mosaic domain model could account for reflections in microgravity crystals whereas reflections from earth crystals required a model with multiple mosaic domains. This statistically significant and unbiased characterization indicates that the microgravity environment was useful for the improvement of crystal growth and resultant diffraction quality in insulin crystals and may be similarly useful for macromolecular crystals in general.

Borgstahl, Gloria E. O.↗

The AIRES Optical Design

AIRES (Airborne InfraRed Echelle Spectrometer) is the facility spectrometer for SOFIA (Stratospheric Observatory For Infrared Astronomy). AIRES is a long-slit (approximately 160 in) spectrometer designed to cover the 17 to 210-micron range with good sensitivity using three spectroscopic arrays. Initially, only the 30-130 micron, mid-wavelength array will be available. The instrument has a cryogenic K-mirror to perform field rotation and a slit-viewing camera (lambda < 28 microns, FOV = 160 in diameter) to image source morphology and verify telescope pointing. AIRES employs a large echelle grating to achieve a spectral resolving power (lambda/delta lambda) of approximately 1.0 x 10(exp 6)/lambda (sub mu), where lambda (sub mu) is the wavelength in microns. Hyperfine, Inc. has ruled and tested the AIRES' echelle; its wave-front error is 0.028 waves RMS (root mean square) at 10.6 microns. The instrument is housed in a liquid-helium cryostat which is constrained in diameter (approximately 1 m) and length (approximately 2 m) by the observatory. Hence, the length of the echelle (approximately 1.1 m) and the focal length of its collimator (approximately 5.2 m) severely drive the optical design and packaging. The final design uses diamond-turned aluminum optics and has up to 19 reflections inside the cryostat, depending on the optical path. This design was generated, optimized, and toleranced using Code V. The predicted performance is nearly diffraction-limited at 17 microns; the error budget is dominated by design residuals. Light loss due to slit rotation and slit curvature has been minimized. A thorough diffraction analysis with GLAD (G-Level Analysis Drawer) was used to size the mirrors and baffles; the internal light loss is shown to be a strong function of slit width.

Haas, Michael R.↗

Free-falling Crystals: Biological Macromolecular Crystal Growth Studies in Low Earth Orbit

Spacecraft orbiting the earth experience a reduced acceleration environment due to being in a state of continuous free-fall. This state colloquially termed microgravity, has produced improved X-ray diffraction quality crystals of biological macromolecules. Improvements in X-ray diffraction resolution (detail) or signal to noise, provide greater detail in the three-dimensional molecular structure providing information about the molecule, how it works, how to improve its function or how to impede it. Greater molecular detail obtained by crystallization in microgravity, has important implications for structural biology. In this article we examine the theories behind macromolecule crystal quality improvement in microgravity using results obtained from studies with the model protein, chicken egg white lysozyme.

Judge, Russell A.↗