At least 1,027 records · Page 57

Wick assisted embedded evaporative cooling of motors

A cooling system for an electric motor that includes a stator having a plurality of slot windings and a rotor, coaxial with the stator, having a plurality of magnets, includes a coolant inlet to the motor and a coolant outlet from the motor. A coolant pathway is in fluid communication with the inlet and the outlet. Heat is transferable from the slot windings to the coolant pathway. A coolant flows through the coolant pathway and is in a liquid phase as it enters the coolant inlet, changing into a gaseous phase as heat is transferred to the coolant from the slot windings. A cooling loop is in fluid communication with the coolant inlet and the coolant outlet. The cooling loop cools the coolant so that substantially all of the coolant is in the liquid phase when it enters the coolant inlet.

Joshi, Yogendra K.↗

Thermal-Hydraulic Performance of a Zeotropic Refrigerant in a Brazed Plate Evaporator

In this work we report the results of a preliminary investigation focused on evaluating the thermal-hydraulic performance of R455A (CO2, R32, R1234yf – 3/21.5/75.5) in a commercial brazed plate heat exchanger. Three key parameters were measured which were refrigerant flow maldistribution, overall refrigerant side heat transfer coefficient, and total refrigerant side pressure drop. These same parameters were also measured for R134a which served as a base-line refrigerant for comparison. The experimental test matrix was set up to investigate the influence of refrigerant mass flux (3 ≤ Gref ≤ 5 kg m-2 s-1), refrigerant inlet vapor quality (0.1 ≤ xin ≤ 0.4), and refrigerant exit superheat (5 ≤ Tsh ≤ 10 K) on the above mentioned thermal-hydraulic parameters. For these experimental conditions, on average, the overall refrigerant side heat transfer coefficients for R455A were 45.2% lower than those of R134a. Refrigerant flow maldistribution for R455A, on average, was observed to be 62.6 % higher than that measured for R134a, and the total pressure drop across the heat exchanger (minor and frictional losses) for R455A was on average 26.5% higher than that measured for R134a. These initial results set the stage for a comprehensive investigation focused on further investigating the thermal-hydraulic performance of zeotropic refrigerants in brazed plate heat exchangers.

Jajja, Saad [ORNL]↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

Path Forward for Groundwater Compliance Strategy at the Tuba City, Arizona, Disposal Site - 19581

The Tuba City, Arizona, Disposal Site is located in the Navajo Nation and near the Hopi Reservation. A uranium mill operated at the site from 1956 to 1966. During the operational period, mill tailings were slurried to an unlined impoundment. Excess slurry water was transferred to unlined evaporation ponds. Groundwater contamination resulting from the infiltration of fluids in the mill tailings impoundment and evaporation ponds was characterized in the 1990's. The site's Groundwater Compliance Action Plan was prepared in 1999, and a groundwater extraction and treatment system was constructed in 2002. Issues with aquifer productivity and treatment plant reliability led to the suspension of operations in 2014. The limitations of the remediation system prompted a realization that the site conceptual model should be reevaluated. An integrated study to better understand the geochemical and hydrologic factors affecting contaminant transport, to support the development of a new groundwater compliance strategy, was initiated in 2017 and is ongoing. In addition to the groundwater science components, the study included the evaluation of enhanced evaporation methods. The integrated evaluation will lead to refinement of the site groundwater flow model and development of a contaminant transport model and subsequent development of remedial alternatives. Remedial alternatives will be evaluated to determine a new groundwater compliance strategy. The objectives of geochemical testing were to confirm and quantify geochemical reactions controlling uranium fate and transport. These reactions are important because they control the distribution of uranium on the solid phase; potential for release from the solid phase; mobility of uranium in the water phase; and potential for uranium redistribution onto the currently uncontaminated solid phase. A key outcome is the change in understanding of the mass of uranium in the subsurface that is potentially soluble. These results contradict the previous basis for remediation: that uranium was almost exclusively present in soluble form, within the boundaries of the contaminant plume. Testing showed that uranium sorption downgradient from the plume was measurable but relatively minimal. The movement of other mill-related constituents (nitrate, sulfate, alkalinity) results in the dissolution of naturally occurring uranium and a higher than background concentration of uranium in groundwater. These constituents are not subject to sorption, and their downgradient concentrations are reduced only by diffusion and dispersion. The geochemical testing provides conceptual and quantitative information on potential plume migration. While the testing revealed the potential availability of uranium contaminant sources, the aquifer buffering capacity, pH, and presence of oxygen in groundwater may, individually or in combination, be controlling factors for plume movement. Evaluation of evaporative treatment alternatives was undertaken to determine one or more sustainable and efficient methods capable of treating 151 liters per minute (L/min) (40 gallons per minute), the annual average flow rate. In addition to establishing the baseline capacity for evaporation using the site's existing pond, prospective methods of enhanced evaporation included preheating water before inflow to the evaporation pond, vertical circulation in the pond, dye addition, and Wind-Aided Intensified Evaporation. Consideration of a 151 L/min evaporative treatment arose from previous analysis of extraction well production rates and contaminant mass removal, which indicated that about 80% contaminant removal, relative to full-scale operation of the site's groundwater treatment plant, could be achieved with a smaller capacity system. The lower-flow evaporative option also represented a potentially more sustainable treatment system in comparison to restarting or reconfiguring the groundwater treatment plant. Aquifer pumping tests were designed to develop or improve estimates of hydraulic properties such as transmissivity, horizontal and vertical hydraulic conductivity, storativity, and storage coefficient. Testing involved pumping from one well at a constant flow rate for up to 5 days while monitoring groundwater drawdown in the pumping well and five surrounding wells and then shutting down the pumping well to observe groundwater recovery. The aquifer pumping test results provide insight regarding the hydraulics of the saturated zone. The saturated zone is in a low-conductivity formation with preferential flow in the horizontal direction. The aquifer exhibits low vertical conductance. The use of AQTESOLV software indicates that the saturated zone is a layered system due to the cross-bedded sand-grain orientation within the Navajo Sandstone. These indicators of limited vertical flow provide a potential justification for the observed depth of the contaminant plume of 15-46 meters (50-150 feet) below ground surface). Given the relatively low vertical conductance, groundwater extraction should be focused on the upper portions of the saturated zone. Aquifer response testing provided an improved understanding of aquifer characteristics. However, the primary objective, to identify optimal groundwater extraction strategies, has not been fully addressed. A list of path forward activities for hydrologic analyses was developed, with an overarching objective of providing input parameters for groundwater flow and contaminant transport modeling. Defensible predictions of contaminant transport, through modeling, are critical to the development of a new site groundwater compliance strategy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grounding our Understanding of the Impacts of Boreal Forest Expansion on Shallow Cumulus Clouds with a Simple Modeling Framework

Abstract The expansion of the boreal forest poleward is a potentially important driver of feedbacks between the land surface and Arctic climate. A growing body of work has highlighted the importance of differences in evaporative resistance between different possible future Arctic land covers, which in turn alters humidity and cloudiness in the boundary layer, for these feedbacks. While thus far this problem has been studied primarily with complex Earth system models, we turn to a locally focused, idealized model capable of diagnosing and testing the sensitivity of first-order processes connecting vegetation, the atmospheric boundary layer, and low clouds in this critical region. This allows us to benchmark the mechanisms and results at the center of predictions from larger-scale simulations. A surface dominated by broadleaf trees, characterized by higher albedo and lower surface evaporative resistance, drives cooling and moistening of the boundary layer relative to a surface of needleleaf trees, characterized by lower albedo and higher surface evaporative resistance. Differences in evaporative resistance between these hypothetical Arctic vegetation covers are of equal importance to changes in albedo for the initial response of the boundary layer to boreal expansion, even with our idealized approach. However, compensation between the elevation of the lifting condensation level (LCL) and more rapid growth of the mixed layer over higher evaporative resistance surfaces can minimize changes in the favorability of shallow clouds over different land cover types under some conditions. We then perform two tests on the sensitivity of this compensating effect, to changes in water availability, represented first by a reduction in boundary layer humidity and then by both a reduction in humidity and soil moisture available to our vegetation surface. Finally, given the importance of this potential LCL–mixed-layer height compensation in our idealized modeling results, we look to determine its relevance in observational data from a field campaign in boreal Finland. These observations do confirm that such a coupling plays an important role in cumulus-topped boundary layers over a needleleaf forest surface. While our results confirm some underlying mechanisms at the center of prior work with Earth system models, they also provide motivation for future work to constrain the impact of boreal forest expansion. This will include both large eddy simulations to examine the impact of processes and feedbacks not resolved by a mixed-layer model, as well as a more systematic evaluation and comparison of relevant observations at the site in Finland and sites from prior boreal field campaigns. Significance Statement Clouds and vegetation are both important components of the climate system that interact across a range of scales. These interactions are central to understanding how changes at the land surface feedback on climate. For example, if a forest expands or recedes, diagnosing how that will impact clouds will determine whether you predict warming or cooling temperatures from that shift in the forest area. These predictions are often made with complex Earth system models, but we look to a more idealized representation of the land–atmosphere system to diagnose how shallow clouds should respond to changes in surface properties with different scenarios of boreal forest expansion at a more foundational level. This both grounds our understanding of previous analysis and provides helpful direction for future studies of this relevant and impactful land cover change.

Meteorology & Atmospheric Sciences↗

Experimental Investigation of the Effect of Gravity on Heat Pipe Startup

This paper describes an experimental investigation of the effect of the gravity pressure head on the startup of a heat pipe under the reflux mode. In this study, a heat pipe with internal axial grooves was placed in an upright position with two different tilt angles relative to the horizontal plane. Heat was applied to the evaporator at the bottom and cooling was provided to the condenser at the top. The liquid-flooded evaporator was divided into seven segments along the axial direction, and electrical heaters were attached to each segment. Heat was applied to individual heaters in various combinations and sequences. Test results show that as long as an individual evaporator segment was flooded with liquid initially, a superheat was required to vaporize the liquid in that segment. The amount of superheat required for liquid vaporization was a function of gravity pressure head imposed on that evaporator segment. The most effective way to start the heat pipe was to apply a heat load with a high heat flux to the lowest segment of the evaporator. This paper describes an experimental investigation of the effect of the gravity pressure head on the startup of a heat pipe under the reflux mode. In this study, a heat pipe with internal axial grooves was placed in an upright position with two different tilt angles relative to the horizontal plane. Heat was applied to the evaporator at the bottom and cooling was provided to the condenser at the top. The liquid-flooded evaporator was divided into seven segments along the axial direction, and electrical heaters were attached to each segment. Heat was applied to individual heaters in various combinations and sequences. Test results show that as long as an individual evaporator segment was flooded with liquid initially, a superheat was required to vaporize the liquid in that segment. The amount of superheat required for liquid vaporization was a function of gravity pressure head imposed on that evaporator segment. The most effective way to start the heat pipe was to apply a heat load with a high heat flux to the lowest segment of the evaporator.

Heat Pipes↗

Purfication kinetics of beryllium during vacuum induction melting

The kinetics of evaporation in binary alloys were quantitatively treated. The formalism so developed works well for several systems studied. The kinetics of purification of beryllium was studied through evaporation data actually acquired during vacuum induction melting. Normal evaporation equations are shown to be generally valid and useful for understanding the kinetics of beryllium purification. The normal evaporation analysis has been extended to cover cases of limited liquid diffusion. It was shown that under steady-state evaporation, the solute concentration near the surface may be up to six orders of magnitude different from the bulk concentration. Corrections for limited liquid diffusion are definitely needed for the highly evaporative solute elements, such as Zn, Mg, and Na, for which the computed evaporation times are improved by five orders of magnitude. The commonly observed logarithmic relation between evaporation time and final concentration further supports the validity of the normal evaporation equations.

Mukherjee, J. L.↗

Experimental Investigation of Heat Pipe Startup Under Reflux Mode

In the absence of body forces such as gravity, a heat pipe will start as soon as its evaporator temperature reaches the saturation temperature. If the heat pipe operates under a reflux mode in ground testing, the liquid puddle will fill the entire cross sectional area of the evaporator. Under this condition, the heat pipe may not start when the evaporator temperature reaches the saturation temperature. Instead, a superheat is required in order for the liquid to vaporize through nucleate boiling. The amount of superheat depends on several factors such as the roughness of the heat pipe internal surface and the gravity head. This paper describes an experimental investigation of the effect of gravity pressure head on the startup of a heat pipe under reflux mode. In this study, a heat pipe with internal axial grooves was placed in a vertical position with different tilt angles relative to the horizontal plane. Heat was applied to the evaporator at the bottom and cooling was provided to the condenser at the top. The liquid-flooded evaporator was divided into seven segments along the axial direction, and an electrical heater was attached to each evaporator segment. Heat was applied to individual heaters in various combinations and sequences. Other test variables included the condenser sink temperature and tilt angle. Test results show that as long as an individual evaporator segment was flooded with liquid initially, a superheat was required to vaporize the liquid in that segment. The amount of superheat required for liquid vaporization was a function of gravity pressure head imposed on that evaporator segment and the initial temperature of the heat pipe. The most efficient and effective way to start the heat pipe was to apply a heat load with a high heat flux to the lowest segment of the evaporator.

Thermal Control Systems↗

Seawater Desalination Derived Entirely from Ocean Biomass

Solar-driven interfacial evaporation shows great prospects for seawater desalination with its rapid fast evaporation rate and high photothermal conversion efficiency. Here, a sustainable, biodegradable, non-toxic, and highly efficient full ocean biomass-based solar-driven evaporator is reported, which is composed of chitosan (CS) hydrogel as the hydratable skeleton and cuttlefish ink (CI) as the photothermal material. Under solar irradiation, the cuttlefish ink powder harvests solar energy and heats the surrounding water. Simultaneously, the water in the three-dimensional network of chitosan hydrogel is rapidly replenished by the interconnected porous structure and the hydrophilic functional groups attached to the polymer chains. With its enlarged evaporation surface, high solar absorptance, adequate water transportation, good salt drainage, and heat localization, the CI/CS-based evaporator achieves a remarkable evaporation rate of 4.1 kg m-2 h-1 under one sun irradiance (1 kW m-2) with high-quality freshwater yields. This full ocean biomass-based evaporator with abundant raw material availability provides new possibilities for an efficient, stable, sustainable, and environmentally friendly solar evaporator with guaranteed water quality.

BIOMASS FUELS,INORGANIC, ORGANIC, PHYSICAL, AND AN↗

Cold-cap formation from a slurry feed during nuclear waste vitrification

The time-temperature history of waste slurry feed during melting strongly affects various kinetic processes, such as reaction or dissolution rates, and, consequently, the melting rate. To analyze the time-temperature history of the feed in a cold-cap during nuclear waste vitrification, this work focuses on understanding how the main coldcap body forms, how the aqueous feed slurry interacts with the cold-cap, and estimating the cold-cap heat conductivity. To simulate the conditions during cold-cap formation, samples were prepared by rapid water evaporation from slurry feed. After water evaporated from the sample, a fresh slurry with tracer was poured onto the dry sample. X-ray fluorescence was then used to investigate the degree of penetration and/or mixing between the incoming slurry and the original sample. We show that the slurry does not interact or mix with the previously dry cold-cap crust, but that water-soluble components concentrate at the bottom of the boiling pools, where most of the water evaporates. Further, using the rate of water evaporation, the heat conductivity of the cold-cap was calculated from the measured temperature profile. The resulting conductivity is significantly higher than the values obtained in previous studies. We discuss the implications of the results for the cold-cap formation in the melter and for the development of the cold-cap mathematical model.

Hujova, Miroslava↗

Measurement of Heat of Vaporization for Research Gasolines and Ethanol Blends by DSC/TGA

The heat of vaporization (HOV) is a relatively poorly studied fuel property that can be related to a fuel's evaporation characteristics and knock resistance and, therefore, the emissions and efficiency of direct-injection spark-ignition engines. Methods for measuring the HOV of complex gasoline mixtures and blends of gasoline with ethanol and other oxygenates require additional development. Recently, we described a differential scanning calorimetry/thermogravimetric (DSC/TGA) method to perform HOV measurements. Herein we describe a detailed investigation of factors affecting the precision and accuracy of the DSC/TGA method and examine enthalpy evolution and mass loss rate for research gasolines as a function of fraction evaporated. Examination of n-hexane evaporation using several DSC/TGA pan/lid configurations showed that initial sample loss can be reduced using a well-fitting pinhole lid on the sample pan, which reduces the evaporation rate during the balance of the experiment. However, additional experiments with research gasolines revealed that tight lid placement on the pans is not always achieved. Nevertheless, accurate total HOV measurements, with less than 10% initial sample loss, could be achieved for low volatility gasolines regardless of lid placement. A higher mass loss might be expected for higher vapor pressure (wintertime) gasolines. Because of variations in pan lids and their placement and their significant impact on results, quantitative comparisons between different samples of mass loss rate and heat flow curves versus time or fraction evaporated are not yet possible. However, features in the mass loss rate and heat flow curves are reproducible. Furthermore, results show that ethanol-gasoline blend evaporation is highly influenced by the formation of near-azeotropic mixtures of ethanol and specific gasoline components, causing a flattening of the mass and heat curves, with a sharp evaporation rate reduction after the ethanol is evaporated.

33 ADVANCED PROPULSION SYSTEMS↗

Effects of Evaporation/Condensation on Spreading and Contact Angle of a Volatile Liquid Drop

Effects of evaporation/condensation on spreading and contact angle were experimentally studied. A sessile drop of R-113 was tested at different vapor environments to determine the effects of evaporation/condensation on the evolution of contact diameter and contact angle of the drop. Condensation on the drop surface occurs at both the saturated and a nonsaturated vapor environments and promotes the spreading. When the drop is placed in the saturated vapor environment it tends to completely wetting and spreads rapidly. In a nonsaturated vapor environment, the evolution of the sessile drop is divided three stages: condensation-spreading stage, evaporation-retracting stage and rapid contracting stage. In the first stage the drop behaves as in the saturated environment. In the evaporation -retracting stage, the competition between spreading and evaporation of the drop determines the evolution characteristics of the contact diameter and the contact angle. A lower evaporation rate struggles against the spreading power to turn the drop from spreading to retracting with a continuous increase of the contact angle. The drop placed in open air has a much higher evaporation rate. The strong evaporation suppresses the spreading and accelerates the retraction of the drop with a linear decrease of the contact diameter. The contraction of the evaporating drops is gradually accelerated when the contact diameter decreases to 3 min and less till drying up, though the evaporation rate is gradually slowing down.

Zhang, Nengli↗

Tropical Ocean Evaporation/SST Sensitivity and It's Link to Water and Energy Budget Variations During ENSO

The continuing debate over feedback mechanisms governing tropical sea surface temperatures (SSTs) and tropical climate in general has highlighted the diversity of potential checks and balances within the climate system. Competing feedbacks due to changes in surface evaporation, water vapor, and cloud long- and shortwave radiative properties each may serve critical roles in stabilizing or destabilizing the climate system. It is also intriguing that even those climate variations having origins internal to the climate system - changes in ocean heat transport for example, apparently require complementary equilibrating effects by changes in atmospheric energy fluxes. Perhaps the best observational evidence of this is the relatively invariant nature of tropically averaged net radiation exiting the top-of-atmosphere (TOA) as measured by broadband satellite sensors over the past two decades. Thus, analyzing how these feedback mechanisms are operating within the context of current interannual variability may offer considerable insight for anticipating future climate change. In this paper we focus primarily on interannual variations of ocean evaporative fluxes and their significance for coupled water and energy cycles within the tropical climate system. In particular, we use both the da Silva estimates of surface fluxes (based on the Comprehensive Ocean Atmosphere Data Set, COADS) and numerical simulations from several global climate models to examine evaporation sensitivity to perturbations in SST associated with warm and cold ENSO events. The specific questions we address are as follows: (1) What recurring patterns of surface wind and humidity anomalies are present during ENSO and how do they combine to yield systematic evaporation anomalies?, (2) What is the resulting tropical ocean mean evaporation-SST sensitivity associated with this climate perturbation?, and (3) What role does this evaporation play in tropical heat and water balance over tropical oceanic regions? We use the da Silva ocean flux data to identify composite structure of departures of latent heat flux from climatology. We also show how these patterns arise out of associated wind and humidity anomaly distributions. Our preliminary work shows that evaporation sensitivity estimates from the da Silva / COADS data, computed for the tropical oceans (30 degrees N/S) are in the neighborhood of 5 to 6 W/square m K. Model estimates are also quite close to this figure. This rate is only slightly less than a rate corresponding to constant relative humidity; however, substantial regional departures from constant relative humidity are present. These patterns are robust and we relate the associated wind and humidity fluctuations noted in previous investigations to the derived evaporation anomalies. Finally, these results are interpreted with other data from the Earth radiation Budget Experiment (ERBE), Global Precipitation Climatology Project (GPCP) and NASA's Surface Radiation Budget (SRB) data set to characterize the tropical energetics of ENSO-related climate variability.

Robertson, Franklin R.↗

Pulse thermal loop

A pulse thermal loop heat transfer system includes a means to use pressure rises in a pair of evaporators to circulate a heat transfer fluid. The system includes one or more valves that iteratively, alternately couple the outlets the evaporators to the condenser. While flow proceeds from one of the evaporators to the condenser, heating creates a pressure rise in the other evaporator, which has its outlet blocked to prevent fluid from exiting the other evaporator. When the flow path is reconfigured to allow flow from the other evaporator to the condenser, the pressure in the other evaporator is used to circulate a pulse of fluid through the system. The reconfiguring of the flow path, by actuating or otherwise changing the configuration of the one or more valves, may be triggered when a predetermined pressure difference between the evaporators is reached.

Weislogel, Mark M.↗

Stratification in Drying Films Containing Bidisperse Mixtures of Nanoparticles

Large scale molecular dynamics simulations for bidisperse nanoparticle suspensions with an explicit solvent are used to investigate the effects of evaporation rates and volume fractions on the nanoparticle distribution during drying. Our results show that “small-on-top” stratification can occur when Pe s Φ s ≳ c with c ~1, where Pe s is the Péclet number and Φ s is the volume fraction of the smaller particles. This threshold of Pe s Φ s for “small-on-top” is larger by a factor of ~α 2 than the prediction of the model treating solvent as an implicit viscous background, where α is the size ratio between the large and small particles. Our simulations further show that when the evaporation rate of the solvent is reduced, the “small-on-top” stratification can be enhanced, which is not predicted by existing theories. This unexpected behavior is explained with thermophoresis associated with a positive gradient of solvent density caused by evaporative cooling at the liquid/vapor interface. For ultrafast evaporation the gradient is large and drives the nanoparticles toward the liquid/vapor interface. This phoretic effect is stronger for larger nanoparticles, and consequently the “small-on-top” stratification becomes more distinct when the evaporation rate is slower (but not too slow such that a uniform distribution of nanoparticles in the drying film is produced), as thermophoresis that favors larger particles on the top is mitigated. A similar effect can lead to “large-on-top” stratification for Pe s Φ s above the threshold when Pe s is large but Φ s is small. Lastly, our results reveal the importance of including the solvent explicitly when modeling evaporation-induced particle separation and organization and point to the important role of density gradients brought about by ultrafast evaporation.

36 MATERIALS SCIENCE↗

Evaluations of the Fates of Alkali Metals, Actinides, Mercury, and Iodine During DWPF Recycle Diversion

The fates of alkali metals, actinides, mercury, and iodine in the Defense Waste Processing Facility Recycle Diversion process (as currently conceptualized) have been evaluated through paper studies based on available knowledge of the chemistry, physical properties, solubility, and volatility of the various species involved. The effect of pH in the range from 9 to 13 has been discussed. Recommendations for additional studies to close technology gaps have been provided, many of which are contingent upon the results of pending testing and sample characterization efforts. There is uncertainty in the amounts of soluble actinides passing through the process filter, though the bulk of the actinides should be captured on the filter with the Recycle Collection Tank solids and the total amounts of actinides should be relatively low. The Recycle Collection Tank pH could impact the fraction of actinides reaching the evaporator, but the primary factors determining the actinide fate are expected to be the amount of CO 2 sorption from air sparging or, for certain actinides (such as plutonium), oxidation and/or sorption to MnO 2 solids from permanganate additions to destroy the glycolate anion. Process optimization could minimize the amounts of actinides passing the filter. Depending upon the levels of mercury observed in recycle stream samples and because of the volatility of mercury, the evaporator should be designed with the capability to remove dense mercury phases from the condensate to avoid exceeding ETP WAC limits. The facility design must be adequate to transfer dense mercury phases and testing to confirm mercury transfer is needed. Simulant containing mercury is recommended for both filtration and evaporation testing. OLI Modeling of the various recycle streams is recommended to provide insight on the fate of iodine. Iodine-spiked simulants are recommended for upcoming evaporation tests. The pro) ect should consider the likelihood and impact of NAS scale formation in the evaporators. Process optimization may be needed to minimize the accumulation of NAS scale and possibly the sorption of actinides in the evaporator. Actual waste testing of the Recycle Diversion filtration and evaporation should include the analysis of actinides, mercury, and iodine to determine their partitioning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternate high capacity heat pipe

The performance predictions for a fifty foot heat pipe (4 foot evaporator - 46 foot condensor) are discussed. These performance predictions are supported by experimental data for a four foot heat pipe. Both heat pipes have evaporators with axial groove wick structures and condensers with powder metal external artery wick structures. The predicted performance of a rectangular axial groove/external artery heat pipe operating in space is given. Heat transport versus groove width is plotted for 100, 200 and 300 grooves in the evaporator. The curves show that maximum power is achieved for groove widths from 0.040 to 0.053 as the number of grooves varies from 300 to 100. The corresponding range of maximum power is 3150 to 2400 watts. The relationships between groove width and heat pipe evaporate diameter for 100, 200 and 300 grooves in the evaporator are given. A four foot heat pipe having a three foot condenser and one foot evaporator was built and tested. The evaporator wick structure used axial grooves with rectangular cross sections, and the condenser wick structure used powder metal with an external artery configuration. Fabrication drawings are enclosed. The predicted and measured performance for this heat pipe is shown. The agreement between predicted and measured performance is good and therefore substantiates the predicted performance for a fifty foot heat pipe.

Voss, F. E.↗

Crystallization of proteins by dynamic control of supersaturation

The growth of protein crystals is known to be the limiting factor in the determination of the three-dimensional structures of most proteins. It is expected that the kinetics of supersaturation, which is directly related to solvent evaporation, will affect protein crystal growth and nucleation and accordingly determine the quality, number, size, and morphology of the crystals. With a technique that controls the evaporation of solvent from a protein solution with N2(g) it is possible to determine the effect of different evaporation profiles on hen egg white lysozyme crystals. Hen egg white lysozyme was chosen as the model protein because it crystallizes easily and has solubility data available for most salt, pH, and temperature ranges. Commercially available lysozyme was further purified by a number of methods. Crystals grown with the purified lysozyme and with the unpurified lysozyme in citrate buffer were different shapes but were found to be of the same symmetry space group by precession photos. Differences were seen in the lysozyme crystals grown using different evaporation rates. At three of the four initial conditions for lysozyme crystal growth, longer evaporation times yielded better crystals. The evaporation times required to see a change in the appearance of the crystals was much longer than expected. The number of rates studied so far represent only a small fraction of the ones now available with the gas evaporation device. The technique also provides for control of both solution pH and temperature which are related to the solubilities of proteins.