Search NASA⌕ Search

SEARCH · Search NASA

Results for “Efficient Envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Applying Best Practices to Florida Local Government Retrofit Programs

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multi-year field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the 'current best practices.' A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. Our new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% SAVINGS↗

Applying Best Practices to Florida Local Government Retrofit Programs, Central Florida (Fact Sheet)

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multi-year field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the "current best practices". A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. Our new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% SAVINGS↗

Initial Flight Test Evaluation of the F-15 ACTIVE Axisymmetric Vectoring Nozzle Performance

A full envelope database of a thrust-vectoring axisymmetric nozzle performance for the Pratt & Whitney Pitch/Yaw Balance Beam Nozzle (P/YBBN) is being developed using the F-15 Advanced Control Technology for Integrated Vehicles (ACTIVE) aircraft. At this time, flight research has been completed for steady-state pitch vector angles up to 20' at an altitude of 30,000 ft from low power settings to maximum afterburner power. The nozzle performance database includes vector forces, internal nozzle pressures, and temperatures all of which can be used for regression analysis modeling. The database was used to substantiate a set of nozzle performance data from wind tunnel testing and computational fluid dynamic analyses. Findings from initial flight research at Mach 0.9 and 1.2 are presented in this paper. The results show that vector efficiency is strongly influenced by power setting. A significant discrepancy in nozzle performance has been discovered between predicted and measured results during vectoring.

Orme, John S.↗

Determination for the 2006 International Energy Conservation Code, Residential Buildings (Technical Support Document)

The Energy Conservation and Production Act of 1976, as amended, requires the U.S. Department of Energy (DOE) to determine whether revisions to the 2006 International Energy Conservation Code (IECC) would improve energy efficiency in residential buildings. An “affirmative determination” for any IECC revision triggers a requirement that each state certify to DOE, within two years of the publication of the determination, that it has reviewed the provisions of the new code and made a determination whether it is appropriate to update its building code(s) to meet or exceed the revised IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

GENERALIZED SEMI-ANALYTICAL MODELS OF SUPERNOVA LIGHT CURVES

We present generalized supernova (SN) light curve (LC) models for a variety of power inputs including the previously proposed ideas of radioactive decay of {sup 56}Ni and {sup 56}Co and magnetar spin-down. We extend those solutions to include finite progenitor radius and stationary photospheres as might be the case for SN that are powered by interaction of the ejecta with circumstellar matter (CSM). We provide an expression for the power input that is produced by self-similar forward and reverse shocks that efficiently convert their kinetic energy into radiation. We find that this ejecta-CSM interaction luminosity that we derive is in agreement with results from multi-dimensional radiation hydrodynamics simulations in the case of an optically thin CSM. We develop a semi-analytical model for the case of an optically thick CSM by invoking an approximation for the effects of radiative diffusion similar to that adopted by Arnett for SN II and compare this model to the results of numerical radiation hydrodynamics models. This model can give complex LCs, but for monotonically declining shock input, the LCs have a smooth rise, peak, and decline. In the context of this model, we provide predictions of the shock breakout of the forward shock from the optically thick part of the CSM envelope. We also introduce a hybrid LC model that incorporates ejecta-CSM interaction plus {sup 56}Ni and {sup 56}Co radioactive decay input. We fit this hybrid model to the LC of the super-luminous supernova (SLSN) 2006gy. We find that shock heating produced by ejecta-CSM interaction plus some contribution from radioactive decay provides a better fit to the LC of this event than previously presented models. We also address the relation between SN IIL and SN IIn with ejecta-CSM interaction models. The faster decline of SN IIL can be reproduced by the diffusion of previously deposited shock power if the shock power input to the diffusive component vanishes when the reverse shock sweeps up the whole ejecta and/or the forward shock propagates through the optically thick CSM. A CSM interaction with forward and reverse shock power input can produce the LCs of SN IIn in terms of duration, shape, and decline rate, depending on the properties of the CSM envelope and the progenitor star. This model can also produce LCs that are symmetric in shape around peak luminosity, which is the case for the observed LCs of some recently discovered peculiar transient events. We conclude that the observed LC variety of SN IIn and of some SLSNe is likely to be a byproduct of the large range of conditions relevant to significant ejecta-CSM interaction as a power source.

79 ASTRONOMY AND ASTROPHYSICS↗

Bounding Methods for Heterogeneous Lidar-derived Navigational Geofences

Safe Unmanned Aerial Vehicle (UAV) operations near the ground require navigation methods that avoid fixed obstacles such as buildings, power lines and trees. Aerial lidar surveys of ground structures are available with the precision and accuracy to geolocate obstacles, but the high volume of raw survey data can exceed the compute power of onboard processors and the rendering ability of ground-based flight planning maps. Representing ground structures with bounding polyhedra instead of point clouds greatly reduces the data size and can enable effective obstacle avoidance, as long as the bounding geometry envelopes the structures with high spatial fidelity. This report describes in detail four methods to compute bounding geometries of ground obstacles from lidar point clouds. The four methods are: 1) 2.5D Maximum Elevation Box, 2) 2.5D Ground Map Extrusion, 3) 3D Bounding Cylinder, and 4) 3D Bounding Box. The methods are applied to five point cloud datasets from lidar surveys of UAV flight research sites in Georgia and Virginia with an average point spacing that ranges from 0.1m to 0.6m. The methods are assessed using survey areas with geometrically heterogeneous ground structures: buildings, vegetation, power lines, and sub-meter structures such as road signs and guy wires. The 2.5D Maximum Elevation Box method is useful for simple structures. The 2.5D Ground Map Extrusion method efficiently encloses vegetation, but requires handdrawn ground footprints. The 3D Bounding Cylinder method excels at enclosing linear structures such as power lines and fences. The 3D Bounding Box method excels at enclosing planar structures such as buildings. The methods are compared on the basis of data compression and boundary fidelity on selected areas. The 2.5D methods yield the highest data compression but the polyhedra produced by them enclose significant amounts of empty space. Boundary fidelity is superior for the 3D methods, though this fidelity comes at the cost of a roughly thirtyfold lower data compression ratio than the 2.5D Maximum Elevation Box method. A mix of these output geometries is proposed for autonomous UAV navigation with limited on-board computing. Both the accuracy and spatial detail of emerging satellite-based survey technology lower than that of aerial lidar scanning survey technology. Sub-meter structures and thin linear structures are not reliably mapped at present by satellite-based surveys.

Moore, Andrew J.↗

Seamless metal-clad fiber-reinforced organic matrix composite structures and process for their manufacture

A metallic outer sleeve is provided which is capable of enveloping a hollow metallic inner member having continuous reinforcing fibers attached to the distal end thereof. The inner member is then introduced into outer sleeve until inner member is completely enveloped by outer sleeve. A liquid matrix member is then injected into space between inner member and outer sleeve. A pressurized heat transfer medium is flowed through the inside of inner member, thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. The novelty of this invention resides in the development of a efficient method of producing seamless metal clad fiber reinforced organic matrix composite structures.

Bluck, Raymond M.↗

COMFEN 3.0 - Evolution of an Early Design Tool for Commercial Facades and Fenestration Systems

Achieving a net-zero energy building cannot be done solely by improving the efficiency of the engineering systems. It also requires consideration of the essential nature of the building including factors such as architectural form, massing, orientation and enclosure. Making informed decisions about the fundamental character of a building requires assessment of the effects of the complex interaction of these factors on the resulting performance of the building. The complexity of these interactions necessitates the use of modeling and simulation tools to dynamically analyze the effects of the relationships, yet decisions about the building fundamentals are often made in the earliest stages of design, before a `building? exists to model. To address these issues, Lawrence Berkeley National Laboratory (LBNL) has developed an early-design energy modeling tool (COMFEN) specifically to help make informed decisions about building facade fundamentals by considering the design of the building envelope, orientation and massing on building performance. COMFEN focuses on the concept of a ?space? or ?room? and uses the EnergyPlus, and RadianceTM engines and a simple, graphic user interface to allow the user to explore the effects of changing key early-design input variables on energy consumption, peak energy demand, and thermal and visual comfort. Comparative results are rapidly presented in a variety of graphic and tabular formats to help users move toward optimal facade and fenestration design choices.While COMFEN 1.0 utilized an ExcelTM-based user interface, COMFEN 3.0 has been reworked to include a simple, more intuitive, yet powerful Graphic User Interface (GUI), a broader range of libraries for associated system and component choices and deliver a wider range of graphic outputs and options. This paper (and presentation) outlines the objectives in developing and further refining COMFEN, the mechanics of the program, and plans for future development.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Advancing Energy Justice in Alaska

NREL works with remote and rural communities across Alaska and the world to develop energy and building technologies that enhance culture, strengthen economies, and improve resilience in a changing environment. Alaska and Arctic communities not only face one of the harshest climates on earth; they also pay some of the highest energy and housing costs in the nation. NREL's Alaska Campus collaborates with communities and tribes to develop affordable, culturally appropriate homes and buildings that combine traditional knowledge and twenty-first century technology. Demonstration homes deployed all over Alaska prove out new technologies in energy efficiency, foundations, indoor air quality, and clean energy. Local workforce development is incorporated into every project: new homes are built by local workers, often including the home's future occupant. With the Arctic warming twice as fast as the rest of the planet, coastal erosion and thawing permafrost are wreaking havoc on roads, buildings, and infrastructure across Alaska. With an inclusive approach to R&D, NREL is helping communities adapt to a changing environment and advancing energy justice in the world's extremes.

Alaska housing prototypes↗

Correlation between cationic lipid-based transfection and cell division

We evaluate the temporal relation between protein expression by cationic lipid-mediated transfection and cell division using time lapse fluorescence microscopy. Detailed image analysis provides new insights on the single cell level while simultaneously achieving appropriate statistics. Earlier evidence by less direct methods such as flow cytometry indicates a primary route for transfection involving nuclear envelope breakdown, but also suggests the existence of a pathway independent of mitosis. We confirm and quantify both mechanisms. We found the timing for successful transfection to be unexpectedly flexible, contrary to assertions of a narrow time window. Specifically, cells dividing more than 24 h after exposure to the transfection medium express the probed protein at a comparable level to cells in a mitotic state during or shortly after transfection. This finding can have a profound impact on the guidance and development of non-viral gene delivery materials. - Highlights: • Cationic lipid-based transfection supports protein expression without cell division. • Protein expression is unrelated to cell cycle status at the time of transfection. • Time-lapse imaging provides direct evaluation without statistical averaging. • Lipoplex dissociation is a likely target for improvement of transfection efficiency.

60 APPLIED LIFE SCIENCES↗

Predicting Envelope Leakage in Attached Dwellings

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Envelope Leakage in Attached Dwellings

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes

In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit test homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Envelope Time Synchronous Averaging for Wind Turbine Gearbox Fault Diagnosis

Vibration-based condition monitoring techniques are widely used for diagnosing faults in rotating machines. These techniques are implemented in the time domain, the frequency domain, or both. However, the composite and noisy nature of the raw data collected requires a preprocessing stage such as filtering and decomposition using in-depth processing techniques. Moreover, these methods require good frequency resolution and involve examining a broad frequency range to discern both healthy and faulty cases. In this work, we introduce a simple and fast diagnostic scheme for wind turbine gear teeth wear based on time domain analysis. The proposed method is based on the local minima interpolation of a filtered version of the vibration signal following time synchronous averaging (TSA) technique. Given tachometer signal, the TSA of the vibration data is performed using MTALAB software. Then, local minima of the filtered signal are interpolated using the Piecewise Cubic Hermite Interpolating Polynomial (PCHIP) function. The variance of the interpolated curve built a gear fault index. The derived fault index resulting of the proposed technique allows a substantial distinction between the healthy and faulty cases. Its efficiency is validated using 10 real-world datasets of vibration stemmed from a wind turbine planetary gearbox. The proposed method boasts a low computation time and ease of interpretation, specifically beneficial for gearbox fault diagnosis purposes.

fault diagnosis↗

Experimental space weathering of regolith material

Significant advances in the understanding of space weathering processes were recently reported. Submicroscopic iron blebs were produced in lunar simulant glass and natural terrestrial minerals by high-temperature reduction in controlled atmosphere furnaces. These experiments altered the samples' optical properties and microtextures so that they resembled those of extremely mature lunar soil. The results contributed to a revised model for natural reduction in the regolith. Subsequently, supporting results were obtained by reduction of lunar samples. Research to date has focused on reduction of three lunar surface components: basalt, pyroclastic glass, and mare soil. An extensive set of H reduction experiments with simulants has led to a detailed understanding of reaction mechanisms and kinetics. Reduction experiments using lunar basalt were recently conducted by Carbotek. Reduced samples from these test were analyzed. Reduction experiments on lunar glass 74220 were run at temperatures of 900-1100 C. Reduction efficiency of volcanic glass proved to be a function of the sample's FeO abundance and reaction temperature. We also reduced mare soil 75061 at temperatures of 900-1050 C. Partial reduction of FeO in olivine and pyroxene occurred, but was slower and less complete than reduction of ilmenite. Our experiments on simulants and lunar samples have indicated that the most readily reduced phases in the regolith are ilmenite and glass. Based on initial tests with simulants we proposed refinements to the accepted model for space weathering of the regolith. The impact of a micrometeoroid flash heats and melts and ejects from the impact point a small volume of soil that contains trapped solar wind H and C. Reduction occurs rapidly, while the melt volume is still in motion. When a droplet encounters unmelted soil, it envelopes cold mineral grains. The melt is chilled rapidly. Our analyses of experimentally reduced lunar basalt, glass, and mare soil support the proposed model for space weathering.

Mckay, D. S.↗

Seasonal Locking of the MJO’s Southward Detour of the Maritime Continent: The Role of the Australian Monsoon

Abstract This study investigates why the major convective envelope of the Madden–Julian oscillation (MJO) detours to the south of the Maritime Continent (MC) only during boreal winter [December–March (DJFM)]. To examine processes affecting this MJO detour, the MJO-related variance of precipitation and column-integrated moisture anomalies in DJFM are compared with those in the seasons before [October–November (ON)] and after [April–May (AM)]. While MJO precipitation variance is much higher in the southern MC (SMC) during DJFM than in other seasons, the MJO moisture variance is comparable among the seasons, implying that the seasonal locking of the MJO’s southward detour cannot be explained by the magnitude of moisture anomalies alone. The higher precipitation variance in the SMC region is partly explained by the much higher moisture sensitivity of precipitation in DJFM than in other seasons, resulting in a more efficient conversion of anomalous moisture to anomalous precipitation. DJFM is also distinguishable from the other seasons by stronger positive wind–evaporation feedback onto MJO precipitation anomalies due to the background westerly wind in the lower troposphere. It is found that the seasonal cycle of moisture–precipitation coupling and wind–evaporation feedback in the SMC region closely follows that of the Australian monsoon, which is active exclusively in DJFM. Our results suggest that the MJO’s southward detour in the MC is seasonally locked because it occurs preferentially when the Australian monsoon system produces a background state that is favorable for MJO development in the SMC.

Intraseasonal variability↗

Carbon Abundance Inhomogeneities and Deep Mixing Rates in Galactic Globular Clusters

Among stars in Galactic globular clusters the carbon abundance tends to decrease with increasing luminosity on the upper red giant branch, particularly within the lowest metallicity clusters. While such a phenomena is not predicted by canonical models of stellar interiors and evolution, it is widely held to be the result of some extra mixing operating during red giant branch ascent which transports material exposed to the CN(O)-cycle across the radiative zone in the stellar interior and into the base of the convective envelope, whereupon it is brought rapidly to the stellar surface. Here we present measurements of [C/Fe] abundances among 67 red giants in 19 globular clusters within the Milky Way. Building on the work of Martell et al., we have concentrated on giants with absolute magnitudes of M {sub V} ∼ −1.5 within clusters encompassing a range of metallicity (−2.4 < [Fe/H] < −0.3). The Kitt Peak National Observatory (KPNO) 4 m and Southern Astrophysical Research (SOAR) 4.1 m telescopes were used to obtain spectra covering the λ4300 CH and λ3883 CN bands. The CH absorption features in these spectra have been analyzed via synthetic spectra in order to obtain [C/Fe] abundances. These abundances and the luminosities of the observed stars were used to infer the rate at which C abundances change with time during upper red giant branch evolution (i.e., the mixing efficiency). By establishing rates over a range of metallicity, the dependence of deep mixing on metallicity is explored. We find that the inferred carbon depletion rate decreases as a function of metallicity, although our results are dependent on the initial [C/Fe] composition assumed for each star.

79 ASTRONOMY AND ASTROPHYSICS↗