Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

On the Equivalence of Two Schemes for Convective Momentum Transport

The Gregory–Kershaw–Inness (GKI) parameterization of convective momentum transport, which has a tunable parameter C, is shown to be identical to a parameterization with no pressure gradient force and a mass flux smaller by a factor of 1 - C. Using cloud-resolving simulations, the transilient matrix for momentum is diagnosed for deep convection in radiative–convective equilibrium. Using this transilient matrix, it is shown that the GKI scheme underestimates the compensating subsidence of momentum by a factor of 1 - C, as predicted. This result is confirmed using a large-eddy simulation.

54 ENVIRONMENTAL SCIENCES↗

Equivalent radiation damage in zirconium irradiated in various reactors - 2016-0101

The physical properties and in-reactor performance of core components made from zirconium alloys are a function of the radiation-induced atomic displacements that occur during service. The vacancy and interstitial point defects and their clusters created by the atomic displacements modify the microstructure, and therefore physical properties such as strength and ductility, by forming dislocation loops. The rate of production of point defects also affects time-dependent properties such as creep and diffusion (mass transport). To simulate the effect of irradiation on core components, researchers have used materials test reactors for many years to irradiate and test materials. Such reactor tests can target an accumulated displacement damage dose to simulate the state of a material at a given stage in reactor life but at an accelerated rate. Each nuclear reactor has a specific neutron energy spectrum that also depends on the in-reactor location. Therefore, to use test reactor data to determine the effect of radiation damage on power reactor materials, one must convert the accumulated dose into a unit that is common in its effect on the material properties. For many property changes in nuclear reactor cores, this unit is displacements per atom. This paper compares the damage production for zirconium irradiated under differing neutron energy spectra in various power and test reactors. The damage rates as a function of different measures of neutron flux were used to relate atomic displacements in various materials test reactors to CANDU and light-water reactor conditions. (authors)

36 MATERIALS SCIENCE↗

$2+1$ dimensional Floquet systems and lattice fermions: Exact bulk spectral equivalence

A connection has recently been proposed between periodically driven systems known as Floquet insulators in continuous time and static fermion theories in discrete time. This connection has been established in a (1+1) ( 1 + 1 ) -dimensional free theory, where an explicit mapping between the spectra of a Floquet insulator and a discrete-time Dirac fermion theory has been formulated. Here we investigate the potential of static discrete-time theories to capture Floquet physics in higher dimensions, where so-called anomalous Floquet topological insulators can emerge that feature chiral edge states despite having bulk bands with zero Chern number. Starting from a particular model of an anomalous Floquet system, we provide an example of a static discrete-time theory whose bulk spectrum is an exact analytic match for the Floquet spectrum. The spectra with open boundary conditions in a particular strip geometry also match up to finite-size corrections. However, the models differ in several important respects. The discrete-time theory is spatially anisotropic, so that the spectra do not agree for all lattice terminations, e.g. other strip geometries or on half spaces. This difference can be attributed to the fact that the static discrete-time model is quasi-one-dimensional in nature and therefore has a different bulk-boundary correspondence than the Floquet model.

Iadecola, Thomas (ORCID:0000000251456441)↗

Macroencapsulation Equivalency Guidance for Classified Weapon Components and NNSSWAC Compliance

The U.S. Department of Energy (DOE) complex has a surplus of classified legacy weapon components generated over the years with no direct path for disposal. The majority of the components have been held for uncertainty of future use or no identified method of sanitization or disposal. As more weapons are retired, there is an increasing need to reduce the amount of components currently in storage or on hold. A process is currently underway to disposition and dispose of the legacy/retired weapons components across the DOE complex.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of Equivalent Sea Level Cosmic Ray Exposure for Low Background Experiment

While scientists at CERN and other particle accelerators around the world explore the boundaries of high energy physics, the Majorana project investigates the other end of the spectrum with its extremely sensitive, low background, low energy detector. The MAJORANA DEMONSTRATOR aims to detect neutrinoless double beta decay (0νββ), a rare theoretical process in which two neutrons decay into two protons and two electrons, without the emission of the two antineutrinos that are a product of a normal double beta decay. This process is only possible if – and therefore a detection would prove — the neutrino is a Majorana particle, meaning that it is its own antiparticle. The existence of such a decay would also disprove lepton conservation and give information about the neutrino's mass.

Greene, Austen T.↗

Package Equivalent Reactor Networks as Reduced Order Models for Use with CAPE-OPEN Compliant Simulation

Engineering simulations of coal gasifiers are typically performed using computational fluid dynamics (CFD) software, where a 3-D representation of the gasifier equipment is used to model the fluid flow in the gasifier and source terms from the coal gasification process are captured using discrete-phase model source terms. Simulations using this approach can be very time consuming, making it difficult to imbed such models into overall system simulations for plant design and optimization. For such system-level designs, process flowsheet software is typically used, such as Aspen Plus®, where each component where each component is modeled using a reduced-order model. For advanced power-generation systems, such as integrated gasifier/gas-turbine combined-cycle systems (IGCC), the critical components determining overall process efficiency and emissions are usually the gasifier and combustor. Providing more accurate and more computationally efficient reduced-order models for these components, then, enables much more effective plant-level design optimization and design for control.

01 COAL, LIGNITE, AND PEAT↗

TASLIMAGE System #2 Technical Equivalence Evaluation

In early 2017, a second TASLIMAGE system (TASL 2) was procured from Track Analysis Systems, Ltd. The new device is intended to complement the first system (TASL 1) and to provide redundancy to the original system which was acquired in 2009. The new system functions primarily the same as the earlier system, though with different X-Y stage hardware and a USB link from the camera to the host computer, both of which contribute to a reduction in CR-39 foil imaging time. The camera and image analysis software are identical between the two systems. Neutron dose calculations are performed externally and independent of the imaging system used to collect track data, relying only on the measured recoil proton track density per cm 2 for a set of known-dose CR-39 foils processed in each etch.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enrichment Meter Dataset from High-Resolution Gamma Spectroscopy Measurements of U3O8 Enrichment Standards and UF6 Cylinder Wall Equivalents

The Enrichment Meter Principle (EMP) is the basis for a commonly used standard test method for the non-destructive assay of 235 U enrichment in bulk compounds [1]. The technique involves determining the net count rate in the direct 186 keV peak using medium or high energy gamma-ray spectrometry in a fixed geometry. With suitable correction for wall attenuation, compound type, rate loss (live time), and peaked background (if significant), the atom fraction of 235 U may be obtained from the counting rate from a linear relationship through the origin. The widespread use of this method for field verification of enrichment [2,3] together with the fact that the response function rests on fundamental physics considerations (i.e., is not represented by a convenient but arbitrary form) makes it an interesting example of uncertainty quantification, one in which one can expect a valid measurement model can be applied. When applied using NaI(Tl) and region of interest analysis, the technique is susceptible to both interference error and bias [2-4]. When implemented using high-resolution gamma-ray spectroscopy, the spectrum interpretation is considerable simplified and more robust [5]. However, a practical challenge to studying the uncertainty budget of the EMP method (for example, to test linearity, extract wall corrections and so forth using modern methods) is the availability of quality experimental data that can be referenced and shared. To fill this gap, the research team undertook an experimental campaign [6]. A measurement campaign was conducted to produce high-resolution gamma spectroscopy enrichment meter data comparable to UF 6 cylinder measurements. The purpose of this report is to provide both an introduction to and quality assurance (QA) of the raw data produced. This report is intended for the analyst or researcher who uses the raw data. Unfortunately, the raw data (i.e., the spectra files) are too voluminous to include in this report but can be requested from Steven Croft of the Safeguards & Security Technology Group (scroft@ornl.gov 865-241-2834). The complete processed data are tabulated in Appendix A. The analysis techniques used to produce the QA data presented in this report [e.g., three regions-ofinterest (ROI) peak extraction and batch analysis processes] are not the most sophisticated techniques available; analysts are encouraged to reanalyze the raw data using more sensitive techniques and to improve upon the results presented here. With that being said, the analysis techniques used here are more than adequate to present and inspect the quality of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Equivalency Evaluation of Lynx Electronics and Apex-InVivo software for the LLNL Whole Body Scanning Bed System

Lawrence Livermore National Laboratory (LLNL) Whole Body Counter (WBC) is replacing the following components for its scanning bed counting system: NIM electronics with modern Lynx electronics, The Alpha Workstation running VMS with a PC running Windows , and Abacos-Plus in-vivo counting software with the new Apex-InVivo software. These new components provide a compact design, extend the lifecycle of the system as a whole, reduce maintenance and user time, an improve overall ease of use. The technical evaluations and results described in this document demonstrate that the total system, incorporating these new components, provides results that comply with Internal Dosimetry requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron Activation Self-Shielding Factors for Common Dosimetry Foils in an ACRR Equivalent Environment

The results of a computational analysis of self-shielding factors are presented. The analysis highlights the total self-shielding, which is a combination of energy and spatial self-shielding, associated with different neutron detection materials. The Monte Carlo N-Particle (MCNP) transport code was used in conjunction with the Evaluated Nuclear Data File (ENDF) and the International Reactor Dosimetry and Fusion Files (IRDFF). This analysis was done with neutron activation analysis in mind, and therefore is modeled and presented in a similar fashion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Many-Body Factorization & Position-Momentum Equivalence of SRC [Slides]

We study short-range correlations (SRC) using the generalized contact formalism (GCF) and quantum Monte Carlo (QMC) calculations of nuclei from deuteron to 40 Ca. We employ different realistic nuclear interactions and extract spin/isospin-dependent nuclear contacts in both coordinate and momentum space.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EPC-ES WIPP WAC Appendix A Equivalence Support Measurements 2019-2020

Characterization of low-level waste (LLW) at Los Alamos National Laboratory (LANL) is primarily performed by the Environmental Protection and Compliance - Environmental Stewardship (EPC-ES) Characterization Services team and/or the Nuclear Process Infrastructure (NPI--9) Nuclear Material Support Services team (hereafter referred to as the gamma spectroscopy teams). The gamma spectroscopy teams use portable high-purity germanium (HPGe) detector systems for the nondestructive assay (NDA) characterization of LLW. Controlled-approved procedures and processes for the use of such systems to assay LLW items are currently in place. Additionally, a number of performance studies have been conducted by the gamma spectroscopy teams to support the efficacy and quality of assay results generated by the established NDA process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗