Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Finite Element Analysis (FEA) for Water-Foam Fracturing of Granite Rock

In addition to the foam data that were obtained from literature and that were collected from the current study, simulation data was also generated from finite element analysis (FEA) conducted in this study using COMSOL Multiphysics software. The FEA models were built to simulate the experiments conducted at Oak Ridge National Laboratory (ORNL) on cement and granite samples. In these FEA models, temperature was kept at ambient while the pressure profile resembled the loading conditions during the ORNL experiments, where pressure was either monotonically increased or applied cyclically. The cement material was used as a model material and was used to study Von Mises stress and tensile stress distribution for different bore hole length geometry using a parametric sweep with water as fracturing fluid using solid-fluid interaction module. For the granite material, FEA models were developed for stress analysis of cylindrical samples with water or foam fluids. The solid mechanics module in COMSOL was implemented to solve for Von Mises stress and tensile stress. The fluid-structure interaction module was implemented to solve for water-foam interaction on granite cylinder with addition of fluid-loading on structure, i.e., large deformation in solid mechanics with no impact on fluid deformation. Foam was considered as a pseudo single-phase compressible fluid for which material properties were calculated from water and gas (nitrogen) phases. The density of foam is calculated as a function of the densities of water and nitrogen, while viscosity is a function of temperature. Four types of FEA analyses were modelled: 1. Monotonic injection with water 2. Monotonic injection with foam 3. Cyclic injection with water 4. Cyclic injection with foam All the COMSOL files are converted to a zip file which is save in .mph.

15 GEOTHERMAL ENERGY↗

The Effect of Weld Metal Composition on Microstructural and Mechanical Properties of Dissimilar Welds Between Monel 400 and Inconel 600

The current work was carried out to characterize welding of Inconel 600 superalloy and Monel 400. In the present study, gas tungsten arc welding (GTAW) with four types of filler metals (ENiCu, ENiCu-7, ENiCr-3 and ENiCrFe-3) was utilized. The filler metals were categorized into two groups based on the presence of Cr and Nb in their chemical composition. This paper describes the selection and application of welding consumables in manufacturing dissimilar metal combinations. It was found that (Nb/Cr) ratio and Fe content can affect on the size and amount of carbides. During solidification of ENiCr-3 and ENiCrFe-3 filler metals, Nb leaves dendritic cores and is rejected to inter-dendritic regions because of its high tendency for segregation. However, No brittle Laves phase was detected in the welds. The interface between weld metal and base metal and gradual changes in alloying elements were also investigated by scanning electron microscopy. EDX analysis was also applied for different samples. Microhardness measurements and tensile test were performed on the joints. The average hardness value in the weld metal obtained from ENiCrFe-3 is higher than the other welds. ENiCu-7 weld exhibited the highest tensile strength of 540 MPa and percent elongation of 53% in contrast to ENiCrFe-3 weld with the lowest tensile strength (518 MPa) and percent elongation (39%).

36 MATERIALS SCIENCE↗

Development and Integration of a Stochastic Clad Damage Propagation Model into PRONGHORN-SC Subchannel Analysis Code

The failure of fuel pins in nuclear reactors is intrinsically stochastic. Typically, a combination of variation in manufacturing that affects the material characteristics and the fuel assembly dimensions, variation in operating conditions, such as local power, coolant flow rate, and irradiation induced changes in material properties lead to a large uncertainty in failure margin of the fuel pins. Failure, therefore, may occur in exceptional pins with adverse combinations of these variations. Upon a metal fuel pin (U-Pu-Zr/HT9) failure, depressurization of the fuel pin takes place by release of fission gas, liquid sodium bond, and potentially solid fuel particles or molten/eutectic fuel droplets through the hole in cladding. The effect of a fission gas jet on neighbor fuel pins and possible propagation of a clad damage during normal operation was studied experimentally in 1970s and it was found that the post-failure fission gas jet insulates the jet impingement area of the target fuel pin surface and could increase the target pin’s surface temperature by as much as 100 – 200 K during the failed pin depressurization. It was concluded that the effect should not lead to fuel pin failure propagation during normal operation. In accident scenarios of sodium and lead fast reactors such as Unprotected Loss-Of-Flow (ULOF) or Unprotected Transient Over Power (UTOP), the fuel pins can be subjected to higher clad temperatures and fuel pin pressures or fuel clad mechanical/chemical interaction where thermal creep margin becomes significantly lower compared to the normal operation conditions. Therefore, possible stochastic failure and the post-failure fission gas/fuel jet impingement could be critical in order to predict fuel pin failure propagation. Pin depressurization due to fission gas release may degrade the heat transfer by formation of a gas blanket on a neighboring pin surface, which is a local phenomenon, and by causing coolant flow deceleration and starvation, which could affect a surrounding region as well. Furthermore, the potential presence of solid fuel particles or molten fuel at the time of clad failure could boost post-failure jet induced degradation even further. The present study models the U-Pu-Zr/HT9 metal fuel pin failure and stochastic clad damage propagation by biased sampling based on a Cumulative Damage Fraction (CDF) type clad failure criterion and the normal distribution of fuel failure probability density as a function of logarithm of Cumulative Damage Fraction. In addition, the effect of post-failure fission gas jet on heat transfer degradation is modeled for the target pins. This model is called stochastic Clad Damage Propagation (CDAP). The CDAP model is now fully integrated into developmental version of PRONGHORN-SC subchannel analysis code, allowing for modeling local failures and its propagation potential. Section 2 describes the components of the CDAP models. Section 3 describes the model implementation to PRONGHORN-SC and input specifications. Section 4 describes the CDAP model validation coupled to PRONGHORN-SC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Search for Xe-129 in mineral grains from Allende inclusions - An exercise in miniaturized rare gas analysis

The paper considers the use of a static mass spectrometer modified by installation of a Baur-Signer ion source and an ion-counting system to detect xenon from single grains from inclusions in the C3 meteorite Allende. The inferred iodine concentrations increased from pentlandite to melilite, but vary widely from one grain to another, indicating that the iodine resides in a minor phase which is included 'spottily' in the bulk phases. It is likely that the detectability for excess Xe achieved here could be improved; about 23,000 of fissiogenic Xe-132 was detected in the largest melelite sample analyzed, but it cannot be determined from this study whether the PU-244 is 'spotty' like I-129 or is uniformly distributed in the melilite.

Reynolds, J. H.↗

Analysis of Chiral Carboxylic Acids in Meteorites

Homochirality of amino acids in proteins and sugars in DNA and RNA is a critical feature of life on Earth. In the absence of a chiral driving force, however, reactions leading to the synthesis of amino acids and sugars result in racemic mixtures. It is currently unknown whether homochirality was necessary for the origins of life or if it was a product of early life. The observation of enantiomeric excesses of certain amino acids of extraterrestrial origins in meteorites provides evidence to support the hypothesis that there was a mechanism for the preferential synthesis or destruction of a particular amino acid enantiomer [e.g., 1-3]. The cause of the observed chiral excesses is un-clear, although at least in the case of the amino acid isovaline, the degree of aqueous alteration that occurred on the meteorite parent body is correlated to the isovaline L-enantiomeric excess [3, 4]. This suggests that chiral symmetry is broken and/or amplified within the meteorite parent bodies. Besides amino acids, there have been only a few reports of other meteoritic compounds found in enantiomeric excess: sugars and sugar acids [5, 6] and the hydroxy acid lactic acid [7]. Determining whether or not additional types of molecules in meteorites are also present in enantiomeric excesses of extraterrestrial information will provide insights into mechanisms for breaking chiral symmetry. Though the previous measurements (e.g., enantiomeric composition of lactic acid [7], and chiral carboxylic acids [8]) were made by gas chromatography-mass spectrometry, the potential for increased sensitivity of liquid chromatography-mass spectrometry (LC-MS) analyses is important because for many meteorite samples, only small sample masses are available for study. Furthermore, at least in the case of amino acids, many of the largest amino acid enantiomeric excesses were observed in samples that contained lower abundances (tens of ppb) of a given amino acid enantiomer. In the present work, we describe our efforts to develop highly sensitive LC-MS methods for the analysis of chiral carboxylic acids including hydroxy acids.

Burton, A. S.↗

Exhaled breath condensate profiles of U.S. Navy divers following prolonged hyperbaric oxygen (HBO) and nitrogen-oxygen (Nitrox) chamber exposures

Prolonged exposure to hyperbaric hyperoxia can lead to pulmonary oxygen toxicity (PO 2 tox). PO 2 tox is a mission limiting factor for special operations forces divers using closed-circuit rebreathing apparatus and a potential side effect for patients undergoing hyperbaric oxygen (HBO) treatment. In this study, we aim to determine if there is a specific breath profile of compounds in exhaled breath condensate (EBC) that is indicative of the early stages of pulmonary hyperoxic stress/PO 2 tox. Using a double-blind, randomized 'sham' controlled, cross-over design 14 U.S. Navy trained diver volunteers breathed two different gas mixtures at an ambient pressure of 2 ATA (33 fsw, 10 msw) for 6.5 h. One test gas consisted of 100% O 2 (HBO) and the other was a gas mixture containing 30.6% O 2 with the balance N 2 (Nitrox). The high O 2 stress dive (HBO) and low O 2 stress dive (Nitrox) were separated by at least seven days and were conducted dry and at rest inside a hyperbaric chamber. EBC samples were taken immediately before and after each dive and subsequently underwent a targeted and untargeted metabolomics analysis using liquid chromatography coupled to mass spectrometry (LC-MS). Following the HBO dive, 10 out of 14 subjects reported symptoms of the early stages of PO 2 tox and one subject terminated the dive early due to severe symptoms of PO 2 tox. No symptoms of PO 2 tox were reported following the nitrox dive. A partial least-squares discriminant analysis of the normalized (relative to pre-dive) untargeted data gave good classification abilities between the HBO and nitrox EBC with an AUC of 0.99 (±2%) and sensitivity and specificity of 0.93 (±10%) and 0.94 (±10%), respectively. Furthermore, the resulting classifications identified specific biomarkers that included human metabolites and lipids and their derivatives from different metabolic pathways that may explain metabolomic changes resulting from prolonged HBO exposure.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of structures of gas atomized and of emulsified highly undercooled Ni-Sn alloy droplets

A comparison is made of microstructures of droplets of Ni-Sn alloys rapidly solidified by gas atomization and in a glass emulsifying medium. Cooling rate of the gas atomized particles ranged from 10 to the 3rd to 10 to the 6th K/s depending on droplet diameter (20-230 microns). In the hypoeutectic alloy studied, /Ni-(25 wt pct Sn)/, most particles showed a dendritic structure. These same particles, melted and resolidified in a glass medium using DTA (Differential Thermal Analysis), showed undercoolings up to 280 K: the structures were dendritic at low undercoolings and nondendritic at undercoolings above 220 K. It is concluded that the gas atomized particles exhibited little or no undercooling before nucleation; the solidification time of the undercooled emulsified droplets is substantially less than that of gas atomized droplets, and the undercooling required to achieve nondendritic structure depends on sample size.

Yamamoto, M.↗

X-Ray Computed Tomography During Preliminary Examination of Apollo Drive Tube 73001

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This began with unsealed core tube 73002 [1,2] that is the upper part of a station 3 double drive tube. More recently the pro-gram extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dis-section [5] of 73001, the lower half of the station 3 double drive tube, that was sealed under vacuum on the Moon. In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) Core Sample Vacuum Container (CSVC). XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube, to ensure it was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into In-Ag alloy). Both scans will provide constraints on future work of this type, particularly for samples collected during the Artemis mission. Another finding from these "engineering" scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection; and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. So far, 92 of the 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition. Because of the dust adhering to particle exteriors it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and basalts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

Galaxy And Mass Assembly (GAMA): Gas Fueling of Spiral Galaxies in the Local Universe. I. The Effect of the Group Environment on Star Formation in Spiral Galaxies

We quantify the effect of the galaxy group environment (for group masses of 10{sup 12.5}–10{sup 14.0} M {sub ⊙}) on the current star formation rate (SFR) of a pure, morphologically selected sample of disk-dominated (i.e., late-type spiral) galaxies with redshift ≤0.13. The sample embraces a full representation of quiescent and star-forming disks with stellar mass M {sub *} ≥ 10{sup 9.5} M {sub ⊙}. We focus on the effects on SFR of interactions between grouped galaxies and the putative intrahalo medium (IHM) of their host group dark matter halos, isolating these effects from those induced through galaxy–galaxy interactions, and utilizing a radiation transfer analysis to remove the inclination dependence of derived SFRs. The dependence of SFR on M {sub *} is controlled for by measuring offsets Δlog(ψ {sub *}) of grouped galaxies about a single power-law relation in specific SFR, ψ{sub ∗}∝M{sub ∗}{sup −0.45±0.01}, exhibited by non-grouped “field” galaxies in the sample. While a small minority of the group satellites are strongly quenched, the group centrals and a large majority of satellites exhibit levels of ψ {sub *} statistically indistinguishable from their field counterparts, for all M {sub *}, albeit with a higher scatter of 0.44 dex about the field reference relation (versus 0.27 dex for the field). Modeling the distributions in Δlog(ψ {sub *}), we find that (i) after infall into groups, disk-dominated galaxies continue to be characterized by a similar rapid cycling of gas into and out of their interstellar medium shown prior to infall, with inflows and outflows of ∼1.5–5 x SFR and ∼1–4 x SFR, respectively; and (ii) the independence of the continuity of these gas flow cycles on M {sub *} appears inconsistent with the required fueling being sourced from gas in the circumgalactic medium on scales of ∼100 kpc. Instead, our data favor ongoing fueling of satellites from the IHM of the host group halo on ∼Mpc scales, i.e., from gas not initially associated with the galaxies upon infall. Consequently, the color–density relation of the galaxy population as a whole would appear to be primarily due to a change in the mix of disk- and spheroid-dominated morphologies in the denser group environment compared to the field, rather than to a reduced propensity of the IHM in higher-mass structures to cool and accrete onto galaxies. We also suggest that the required substantial accretion of IHM gas by satellite disk-dominated galaxies will lead to a progressive reduction in the specific angular momentum of these systems, thereby representing an efficient secular mechanism to transform morphology from star-forming disk-dominated types to more passive spheroid-dominated types.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of data from the Pioneer Venus Sounder Probe mass spectrometer

The composition of the lower atmosphere of the planet Venus from 62 km to the surface was measured by a neutral gas mass spectrometer onboard of the Pioneer Venus Sounder Probe. Fifty-one mass spectra were obtained with an average altitude resolution of approximately 1 km. The instrument measured the composition of the gases relative to CO2, the dominant gas, that is sampled from the Venus atmosphere through a special leak. The mass range extended from 1 to 208 amu with a sensitivity of the order of 1 ppm relative to CO2, but for the noble gases it was nearly 100 times better. A description of the instrument and the initial results are reported.

Hoffman, J. H.↗

The Combined Detection of Morphological and Molecular Biomarkers: Implications for Astrobiology

Experience gathered by previous researchers during their hunt for evidence of early Earth life has shown the complexity in interpreting observations of possible microfossils and to establish the evidence to be positive. Similarly, the stillsimmering controversy on the nature of the nano-structures in Martian meteorite ALH84001 described by McKay et al. (1996) emphasizes the difficulties of conclusively identifying those structures as (a) fossilized bacterial cells and (b) establish their indigeneity. A better understanding of biological signatures in rocks is needed in order to identify traces of microbial life, which include morphological, mineralogical and chemical traces. It is thus considered crucial to tackle the problems emerging in the search for evidence of early life on Earth and in exopaleontological research with a multidisciplinary approach. With this is mind we applied surface sensitive Time of Flight-Secondary Ion Mass Spectroscopy (ToF-SIMS) to a previously described 25 m.y. old fossil bacterial biofilm. This technique allows in situ analysis with high mass resolution as well as molecular imaging of micron sized structures. As no extraction or derivatisation of the sample is required for ToF-SIMS analysis, electron microscopical investigation of the same samples subsequent to analysis is possible, thus allowing the combination of molecular and morphological biomarkers. The analysed fossil bacterial biofilms were associated with macrofossils from volcanoclastic lacustrine sediments from the Upper Oligocene Enspel formation (Germany). Preliminary scanning electron microscopy (SEM) studies have shown that a fossil structure interpreted as a coprolite purely consisted of fossilized bacterial biofilm. For ToF-SIMS investigation small particles were taken from the fossil biofilm and mounted onto Au-coated In-foil and analysed in a Phi Evans T-2000 TRIFT system. The ToF-SIMS analysed samples were Au/Pd-sputter coated and imaged using a Philips XL40 Field Emission Gun SEM (FEG-SEM). ToF-SIMS analysis of the organic rich fossil biofilm (TOC 29%) in the 0-100 Dalton (Da) range showed significant amounts of inorganic species, confirming the results obtained previously by EDX analysis, clearly showing the bacterial fossils to be mineralised. ToF-SIMS furthermore revealed the presence of a variety of low- and high-mass organic molecules and fragments thereof. These include peaks indicative of alkenes and alkanes, aromatic organic species and the polycyclic aromatic hydrocarbon naphthalene. More tentatively, peaks indicative of alkyl pyrroles and pyridyl-CH2 were identified. Other peaks of interest include peaks indicative of C(n)H(2n)O2 and C(n)H(2n-2)O2, which according to their general formula would suggest the presence of both saturated and unsaturated fatty acids although further in situ derivatisation experiments and GC-MS (Gas Chromatography MS) need to be applied to verify this beyond doubt. Furthermore, peaks at m/z 370, 384, 398, 412, 426, 440, 454 and 468 were identified, which indicate the potential presence of bacterial hopanes, a class of biomarkers indicative of bacteria. The main diagnostic peak for this group of chemicals is the fragment at m/z 191.18. Our studies conducted on purified hopane standards have shown that in the high-mass resolution mode differentiation of this diagnostic hopane peak and polyethylene at m/z 191.05 is possible. However, the spectra discussed here were collected in the lower resolution mapping mode, therefore this differentiation was not possible. The centroids of the possible hopane peaks obtained on the fossil biofilms are well within the range associated with bacterial hopanes. There is a strong possibility therefore that hopanoids may be associated with the fossil bacterial cells. Due to the non-destructive nature of ToF-SIMS, analysed samples can be studied using SEM, thus allowing the combination of morphological and molecular biomarkers. Subsequent SEM analysis of the ToF-SIMS analysed samples confirmed that the analysed material purely consists of fossil bacterial cells. This is thus the first successful effort to demonstrate the combination of spectral and morphological biomarkers. The advantages of highly sensitive non-destructive in situ analysis techniques for biomarker detection are invaluable, particularly with respect to envisaged Mars sample return missions, as it may allow us to identify remains and traces of former microbial life in both ancient terrestrial and extraterrestrial materials. This technique may prove particularly useful in the quest for extraterrestrial life with respect to precious extraterrestrial materials, as minute quantities are sufficient to conduct analysis.

Toporski, J.↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Failure Analysis and Magnetic Evaluation of Tertiary Superheater Tube Used in Gas-Fired Boiler

Failure analysis was carried out on a prematurely failed tertiary superheater tube used in gas-fired boiler. The analysis includes a comparative study of visual examination, chemical composition, hardness and microstructure at failed region, adjacent and far to failure as well as on fresh tube. The chemistry was found matching to the standard specification, whereas the hardness was low in failed tube compared to the fish mouth opening region and the fresh tube. Microscopic examination of failed sample revealed the presence of spheroidal carbides of Cr and Mo predominantly along the grain boundaries. The primary cause of failure is found to be localized heating. Magnetic hysteresis loop (MHL) measurements were carried out to correlate the magnetic parameters with microstructure and mechanical properties to establish a possible non-destructive evaluation (NDE) for health monitoring of the tubes. The coercivity of the MHL showed a very good correlation with microstructure and mechanical properties deterioration enabling a possible NDE technique for the health monitoring of the tubes.

36 MATERIALS SCIENCE↗

Two-Stage Conversion of Silicon to Nanostructured Carbon by the Method of Coordinated Atomic Substitution

Abstract—: A fundamentally new method of obtaining epitaxial layers of nanostructured carbon on silicon substrates has been considered. Epitaxial growth in the case of seemingly incompatible lattices has been achieved by converting the crystal by the method of coordinated substitution of atoms, in which the overall structure of the bonds between the atoms is not destroyed. In the first stage of conversion, the first half of the silicon atoms are concertedly replaced by the carbon atoms due to the reaction of silicon with CO gas, during which an epitaxial layer of SiC–3C cubic silicon carbide is obtained. In the second stage of conversion, the remaining half of silicon atoms is concertedly replaced by carbon atoms due to the reaction of SiC with CF{sub 4} gas. Carbon structures with different properties from nanodiamonds to nanotubes and carbon nanoonions have been obtained depending on the orientation of the silicon surface, pressure of the reagent gas, and temperature and growth time. A key feature of this method is that the substrate orders the resulting structures using the original chemical bonds between the atoms in silicon. The term “concertedly” means that new chemical bonds are formed simultaneously and concertedly with the destruction of old bonds. Data on electron diffraction and analysis of Raman and ellipsometric spectra of the obtained samples of nanostructured carbon on silicon substrates have been presented. Two competing growth mechanisms have been discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mass spectrometric analysis of organic compounds, water and volatile constituents in the atmosphere and surface of Mars - The Viking Mars Lander.

An experiment centering around a mass spectrometer is described, which is aimed at the identification of organic substances present in the top 10 cm of the surface of Mars and an analysis of the atmosphere for major and minor constituents as well as isotopic abundances. In addition, an indication of the abundance of water in the surface and some information concerning the mineralogy can be obtained by monitoring the gases produced upon heating the soil sample. The organic material will simply be expelled by heating to 150, 300, and 500 C into the carrier gas stream of a gas chromatograph interfaced to the mass spectrometer or by slowly heating the sample in direct communication with the spectrometer. It is planned to analyze a total of up to nine soil samples in order to study diurnal and seasonal variations. The system is designed to give useful data even for minor constituents if the total of organics should be as low as 5 ppm. The spectrometer covers the mass range of 12-200 with adequate resolution.

Anderson, D. M.↗

Techniques for the analysis of gases sequentially released from lunar samples

Description of two methods for the analysis of light gases that are sequentially evolved from 2 to 10 mg of lunar sample. A hydrofluoric acid hydrolysis of lunar material is achieved by repeated exposure of the sample to hydrogen fluoride. In the second technique, gases are evolved from lunar samples by the stepwise heating of these samples to 1400 C. The gases evolved by either hydrolysis or pyrolysis are analyzed in a gas chromatographic system using a helium ionization detector. The sensitivities of this detector for the gases, as analyzed, range from 20 picograms/sec for hydrogen to 0.2 picogram/sec for carbon dioxide.

Desmarais, D. J.↗

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.↗

A Unique, Optically Accessible Flame Tube Facility for Lean Combustor Studies

A facility that allows interrogation of combusting flows by advanced diagnostic methods and instrumentation has been developed at the NASA Lewis Research Center. An optically accessible flame tube combustor is described which has high temperature, pressure, and air flow capabilities. The windows in the combustor measure 3.8 cm axially by 5.1 cm radially, providing 67% optical access to the 7.6 cm x 7.6 cm cross section flow chamber. Advanced gas analysis instrumentation is available through a gas chromatography/mass spectrometer system (GC/MS), which has on-line capability for heavy hydrocarbon measurement with resolution to the parts per billion level. The instrumentation allows one to study combusting flows and combustor subcomponents, such as fuel injectors and air swirlers. Planar Laser Induced Fluorescence (PLIF) can measure unstable combustion species, which cannot be obtained with traditional gas sampling. This type of data is especially useful to combustion modellers. The optical access allows measurements to have high spatial and temporal resolution. GC/MS data and PLIF images of OH- are presented from experiments using a lean direct injection (LDI) combustor burning Jet-A fuel at inlet temperatures ranging from 810 K to 866 K, combustor pressures up to 1380 kPa, and equivalence ratios from 0.41 to 0.59.

Hicks, Yolanda R.↗