Search NASA⌕ Search

SEARCH · Search NASA

Results for “Generating Source(s)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Single-shot structural analysis by high-energy X-ray diffraction using an ultrashort all-optical source

High-energy X-rays (HEX-rays) with photon energies on order of 100 keV have attractive characteristics, such as comparably low absorption, high spatial resolution and the ability to access inner-shell states of heavy atoms. These properties are advantageous for many applications ranging from studies of bulk materials to the investigation of materials in extreme conditions. Ultrafast X-ray diffraction allows the direct imaging of atomic dynamics simultaneously on its natural time and length scale. However, using HEX-rays for ultrafast studies has been limited due to the lack of sources that can generate pulses of sufficiently short (femtosecond) duration in this wavelength range. Here we show single-crystal diffraction using ultrashort ~90 keV HEX-ray pulses generated by an all-optical source based on inverse Compton scattering. We also demonstrate a method for measuring the crystal lattice spacing in a single shot that contains only ~10 5 photons in a spectral bandwidth of ~50% full width at half maximum (FWHM). Our approach allows us to obtain structural information from the full X-ray spectrum. As target we use a cylindrically bent Ge crystal in Laue transmission geometry. As a result, this experiment constitutes a first step towards measurements of ultrafast atomic dynamics using femtosecond HEX-ray pulses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dephasingless laser wakefield acceleration in the bubble regime

Abstract Laser wakefield accelerators (LWFAs) have electric fields that are orders of magnitude larger than those of conventional accelerators, promising an attractive, small-scale alternative for next-generation light sources and lepton colliders. The maximum energy gain in a single-stage LWFA is limited by dephasing, which occurs when the trapped particles outrun the accelerating phase of the wakefield. Here, we demonstrate that a single space–time structured laser pulse can be used for ionization injection and electron acceleration over many dephasing lengths in the bubble regime. Simulations of a dephasingless laser wakefield accelerator driven by a 6.2-J laser pulse show 25 pC of injected charge accelerated over 20 dephasing lengths (1.3 cm) to a maximum energy of 2.1 GeV. The space–time structured laser pulse features an ultrashort, programmable-trajectory focus. Accelerating the focus, reducing the focused spot-size variation, and mitigating unwanted self-focusing stabilize the electron acceleration, which improves beam quality and leads to projected energy gains of 125 GeV in a single, sub-meter stage driven by a 500-J pulse.

43 PARTICLE ACCELERATORS↗

Entropy removal of medical diagnostics

Shannon entropy is a core concept in machine learning and information theory, particularly in decision tree modeling. To date, no studies have extensively and quantitatively applied Shannon entropy in a systematic way to quantify the entropy of clinical situations using diagnostic variables (true and false positives and negatives, respectively). Decision tree representations of medical decision-making tools can be generated using diagnostic variables found in literature and entropy removal can be calculated for these tools. This concept of clinical entropy removal has significant potential for further use to bring forth healthcare innovation, such as quantifying the impact of clinical guidelines and value of care and applications to Emergency Medicine scenarios where diagnostic accuracy in a limited time window is paramount. This analysis was done for 623 diagnostic tools and provided unique insights into their utility. For studies that provided detailed data on medical decision-making algorithms, bootstrapped datasets were generated from source data to perform comprehensive machine learning analysis on these algorithms and their constituent steps, which revealed a novel and thorough evaluation of medical diagnostic algorithms.

97 MATHEMATICS AND COMPUTING↗

Bio-inspired strategies for next-generation perovskite solar mobile power sources

Smart electronic devices are becoming ubiquitous due to many appealing attributes including portability, long operational time, rechargeability and compatibility with the user-desired form factor. Integration of mobile power sources (MPS) based on photovoltaic technologies with smart electronics will continue to drive improved sustainability and independence. With high efficiency, low cost, flexibility and lightweight features, halide perovskite photovoltaics have become promising candidates for MPS. Realization of these photovoltaic MPS (PV-MPS) with unconventionally extraordinary attributes requires new ‘out-of-box’ designs. Natural materials have provided promising designing solutions to engineer properties under a broad range of boundary conditions, ranging from molecules, proteins, cells, tissues, apparatus to systems in animals, plants, and humans optimized through billions of years of evolution. Applying bio-inspired strategies in PV-MPS could be biomolecular modification on crystallization at the atomic/meso-scale, bio-structural duplication at the device/system level and bio-mimicking at the functional level to render efficient charge delivery, energy transport/utilization, as well as stronger resistance against environmental stimuli (e.g., self-healing and self-cleaning). In this paper, we discuss the bio-inspired/-mimetic structures, experimental models, and working principles, with the goal of revealing physics and bio-microstructures relevant for PV-MPS. Here the emphasis is on identifying the strategies and material designs towards improvement of the performance of emerging halide perovskite PVs and strategizing their bridge to future MPS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mean-field limit of a hybrid system for multi-lane multi-class traffic

This article aims to study coupled mean-field equation and ODEs with discrete events motivated by vehicular traffic flow. Precisely, multi-lane traffic flow in presence of human-driven and autonomous vehicles is considered, with autonomous vehicles possibly influenced by external policymakers. First, a finite-dimensional hybrid system is developed based on the continuous Bando-Follow-the-Leader dynamics coupled with discrete events due to lane-change maneuvers. Then the mean-field limit of the finite-dimensional hybrid system is rigorously derived for the dynamics of the human-driven vehicles. The microscopic lane-change maneuvers of the human-driven vehicles generate a source term for the mean-field PDE. This leads to an infinite-dimensional hybrid system described by coupled Vlasov-type PDE, ODEs, and discrete events.

97 MATHEMATICS AND COMPUTING↗

Two-dimensional/three-dimensional simulations for the optimization of an electron-beam-generated-plasma-based-type ion source

To fulfill the need of a plasma ion source for SPIRAL-2 and EURISOL, capable of producing radioactive ion beams under strong radiation, the first prototype of the IRENA (Ionization by Radial Electrons Neat Adaptation) ion source has been designed. For designing an optimized prototype based on the first one, the influence of the geometrical parameters on the electron trajectories is investigated by means of two-dimensional/three-dimensional (3D) simulations. Due to the strong space charge effect in this kind of ion source, 3D simulations help particularly to better estimate effects on ion confinement and extraction. Simulation constructions will be presented and results discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Schwinger-Dyson operators as invariant vector fields on a matrix model analog of the group of loops

For a class of large-N multimatrix models, we identify a group G that plays the same role as the group of loops on space-time does for Yang-Mills theory. G is the spectrum of a commutative shuffle-deconcatenation Hopf algebra that we associate with correlations. G is the exponential of the free Lie algebra. The generating series of correlations is a function on G and satisfies quadratic equations in convolution. These factorized Schwinger-Dyson or loop equations involve a collection of Schwinger-Dyson operators, which are shown to be right-invariant vector fields on G, one for each linearly independent primitive of the Hopf algebra. A large class of formal matrix models satisfying these properties are identified, including as special cases, the zero momentum limits of the Gaussian, Chern-Simons, and Yang-Mills field theories. Moreover, the Schwinger-Dyson operators of the continuum Yang-Mills action are shown to be right-invariant derivations of the shuffle-deconcatenation Hopf algebra generated by sources labeled by position and polarization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of transverse ion beam emittance generated by high current ion sources at the GSI test injector facility HOSTI

The first emittance measurements with a new test injector facility (HOSTI) at GSI, designed for optimization of high current beam injection scheme, are discussed. The emittance of the ion beam (88 kV, Ar{sup 1+} ions) was investigated as a function of various parameters related to the ion source, extraction, and postacceleration systems and the optimum parameters for future low energy beam transport line are concluded. The preliminary results of the emittance measurements with superconducting solenoid are presented. The influence of the focusing strength as well as the longitudinal field shape of the solenoid on the beam emittance is described.

43 PARTICLE ACCELERATORS↗

Diamond Photodetectors for X-Ray Absorption Spectroscopy Applications

Synchrotron radiation (SR) is a fundamental tool for X-ray research. In particular, X-ray absorption spectroscopy (XAS) accesses information as electronic properties, local structure or chemical-physical state in condensed-matter studies. Ionization chambers (ICs) are the most widely used XAS detectors for transmission measurements because of their reliability, high linearity and good stability. Recently, solid-state detectors have been considered and Si p-i-n has been applied to high fluxes (10{sup 11} ph/s), where the linearity of ICs is no longer guaranteed. Silicon photodiodes exhibit an extremely linear response in at least 5 decades but show diffraction peaks. Diamond is an ideal substrate to produce radiation-hard, low dark current (<1 pA/cm{sup 2}), visible-blind and fast-response X-ray detectors with a high S/N ratio. Diamond detectors were tested as SR monitor capable to withstand the high photon flux density of the 3{sup rd} generation SR sources. Being the lowest X-ray-absorbing solid-state dielectric material, diamond maximizes the flux through thin self-standing devices with minimal spectral effect down to the soft x-ray range. We will present results of X-ray tests of photoconductors based on different diamond substrates. The results will be compared to standard ICs for XAS applications in terms of spectral quality, noise and linearity in the 4-13 keV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of polyaromatic molecules via ion-molecule reactions: An experimental and theoretical mechanistic study

The reactivity of naphthyl cations with benzene is investigated in a joint experimental and theoretical approach. Experiments are performed by using guided ion beam tandem mass spectrometers equipped with electron impact or atmospheric pressure chemical ion sources to generate C{sub 10}H{sub 7}{sup +} with different amounts of internal excitation. Under single collision conditions, C-C coupling reactions leading to hydrocarbon growth are observed. The most abundant ionic products are C{sub 16}H{sub 13}{sup +}, C{sub 16}H{sub n}{sup +} (with n=10-12), and C{sub 15}H{sub 10}{sup +}. From pressure-dependent measurements, absolute cross sections of 1.0{+-}0.3 and 2{+-}0.6 A{sup 2} (at a collision energy of about 0.2 eV in the center of mass frame) are derived for channels leading to the formation of C{sub 16}H{sub 12}{sup +} and C{sub 15}H{sub 10}{sup +} ions, respectively. From cross section values a phenomenological total rate constant k=(5.8{+-}1.9)x10{sup -11} cm{sup 3} s{sup -1} at an average collision energy of about 0.27 eV can be estimated for the process C{sub 10}H{sub 7}{sup +}+C{sub 6}H{sub 6}{yields} all products. The energy behavior of the reactive cross sections, as well as further experiments performed using partial isotopic labeling of reagents, support the idea that the reaction proceeds via a long lived association product, presumably the covalently bound protonated phenylnaphthalene, from which lighter species are generated by elimination of neutral fragments (H, H{sub 2}, CH{sub 3}). A major signal relevant to the fragmentation of the initial adduct C{sub 16}H{sub 13}{sup +} belongs to C{sub 15}H{sub 10}{sup +}. Since it is not obvious how CH{sub 3} loss from C{sub 16}H{sub 13}{sup +} can take place to form the C{sub 15}H{sub 10}{sup +} radical cation, a theoretical investigation focuses on possible unimolecular transformations apt to produce it. Naphthylium can act as an electrophile and add to the {pi} system of benzene, leading to a barrierless formation of the ionic adduct with an exothermicity of about 53 kcal mol{sup -1}. From this structure, an intramolecular electrophilic addition followed by H shifts and ring opening steps leads to an overall exothermic loss (-7.1 kcal mol{sup -1} with respect to reagents) of the methyl radical from that part of the system which comes from benzene. Methyl loss can take place also from the ''naphthyl'' part, though via an endoergic route. Experimental and theoretical results show that an ionic route is viable for the growth of polycyclic aromatic species by association of smaller building blocks (naphthyl and phenyl rings) and this may be of particular relevance for understanding the formation of large molecules in ionized gases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remotely induced atmospheric lasing

We propose and analyze a remote atmospheric lasing configuration which utilizes a combination of an ultrashort pulse laser to form a plasma filament (seed electrons) by tunneling ionization and a heater pulse which thermalizes the seed electrons. Electrons collisionally excite nitrogen molecules and induce lasing in the ultraviolet. The lasing gain is sufficiently high to reach saturation within the length of the plasma filament. A remotely generated ultraviolet source may have applications for standoff detection of biological and chemical agents.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray Microscopy Beamlines at SSRF--Present Status and Future Plan

The Shanghai Synchrotron Radiation Facility (SSRF) is a 3.5-GeV third-generation light source. The facility has been open for user experiments since May, 2009. This high-brightness x-ray source is an ideal platform for x-ray microscopy. Presently, SSRF has three beamlines related to x-ray microscopy or imaging, namely the soft x-ray spectromicroscopy beamline (STXM), the hard x-ray microfocusing beamline, and the x-ray imaging beamline. The construction of SSRF phase-II beamlines will be carried out during 2011-2017. Seven additional beamlines for x-ray microscopy or imaging will be built.

07 ISOTOPE AND RADIATION SOURCES↗

New methods for high current fast ion beam production by laser-driven acceleration

An overview of the last experimental campaigns on laser-driven ion acceleration performed at the PALS facility in Prague is given. Both the 2 TW, sub-nanosecond iodine laser system and the 20 TW, femtosecond Ti:sapphire laser, recently installed at PALS, are used along our experiments performed in the intensity range 10{sup 16}-10{sup 19} W/cm{sup 2}. The main goal of our studies was to generate high energy, high current ion streams at relatively low laser intensities. The discussed experimental investigations show promising results in terms of maximum ion energy and current density, which make the laser-accelerated ion beams a candidate for new-generation ion sources to be employed in medicine, nuclear physics, matter physics, and industry.

43 PARTICLE ACCELERATORS↗

Remote lasing in air by recombination and electron impact excitation of molecular nitrogen

We analyze and simulate the physical mechanisms for a remote atmospheric lasing configuration which utilizes a combination of an ultrashort pulse laser to form a plasma filament of seed electrons, and a heater beam to heat the seed electrons. Nitrogen molecules are excited by electron impact and recombination processes to induce lasing in the ultraviolet. Recombination excitation, thermal excitation, gain, and saturation are analyzed and simulated. The lasing gain is sufficiently high to reach saturation within the length of the plasma filament. A remotely generated ultraviolet source may have applications for standoff detection of biological and chemical agents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positron production using a 1.7 MV pelletron accelerator

We report the foremost phase of a fourth generation positron source, being constructed at the Federal University of Rio de Janeiro. Positron yields are reported by making use of the {sup 19}F(p,{alpha}e{sup +}e{sup -}){sup 16}O reaction, where the fluorine target is in the form of a CaF{sub 2} pellet. Positron production has been observed by detecting 511 keV annihilation gamma rays emerging from the irradiated CaF{sub 2} target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Damage of multilayer optics with varying capping layers induced by focused extreme ultraviolet beam

Extreme ultraviolet Mo/Si multilayers protected by capping layers of different materials were exposed to 13.5 nm plasma source radiation generated with a table-top laser to study the irradiation damage mechanism. Morphology of single-shot damaged areas has been analyzed by means of atomic force microscopy. Threshold fluences were evaluated for each type of sample in order to determine the capability of the capping layer to protect the structure underneath.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast synchrotron X-ray tomography study of the rod packing structures

We present a fast synchrotron X-ray tomography study of the packing structures of rods under tapping. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can complete a tomography scan within several seconds, after which the three-dimensional (3D) packing structure can be obtained for the subsequent structural analysis. Due to the high-energy nature of the X-ray beam, special image processing steps including image phase-retrieval has been implemented. Overall, this study suggests the possibility of acquiring statistically significant static packing structures within a reasonable time scale using high-intensity X-ray sources.

36 MATERIALS SCIENCE↗