Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

High power operation of a nitrogen doped, vanadium compensated, 6H-SiC extrinsic photoconductive switch

We report the high power operation of nitrogen doped, vanadium compensated, 6H-SiC, extrinsic photoconductive switches with improved vanadium and nitrogen dopant density. Photoconductive switching tests are performed on 1 mm thick, m-plane, switch substrates at switch voltage and currents up to 17 kV and 1.5 kA, respectively. Sub-ohm minimum switch on resistance is achieved for peak optical intensities ≥35 MW/cm{sup 2} at 532 nm applied to the switch facet. A reduction of greater than nine orders of magnitude is observed in switch material resistivity between dark and illuminated states.

36 MATERIALS SCIENCE↗

Adaptive Voltage Regulation for Solar Power Inverters on Distribution Systems

The most recent version of IEEE 1547 has incorporated four reactive power control modes, including constant power factor, voltage-reactive power (Volt-Var), active power-reactive power and constant reactive power. These modes are specified to be mutually exclusive, and they don’t include every smart inverter function proposed by industry collaboration. In earlier work, we found that Volt-Var settings could be optimized but were sensitive to changes in the normal grid voltage. This sensitivity can be mitigated by combining Volt-Var with dynamic reactive current (DRC), but neither DRC nor combined modes appear in IEEE 1547. One problem with Volt-Var is the default dead-band; it mitigates the sensitivity to setpoint, but also limits the effectiveness in managing voltage fluctuations. There has been continued interest in tuning smart inverter functions locally, and in combining central with local control, but this process still requires extensive simulations. The goal is to find a default inverter setting that will effectively mitigate voltage fluctuations even as grid conditions change. It must be compatible with the current version of IEEE 1547. It should also be compatible with advanced control methods when available. Otherwise, it should not require communications, detailed engineering studies or field commissioning of custom settings. This would facilitate the integration of distributed solar in larger amounts. Adaptive voltage regulation (AVR) is a Volt-Var implementation, but with “autonomously adjusting” setpoint as described below Table 8 in IEEE 1547. Through simulation of a test system in OpenDSS, it was shown that AVR having a high gain and a time constant of 300 seconds could work well in any location. This mode and setting should be considered for a new universal default setting on smart inverters.

McDermott, Thomas E.↗

Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter

The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short 1 , Short 2 , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short 2 with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. Here, a 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.

42 ENGINEERING↗

Frequency and temperature dependences of capacitance-voltage characteristics of InGaN/GaN light-emitting structures with multiple quantum wells

A frequency dependence of capacitance-voltage (C-V) characteristics in multiple quantum well InGaN/GaN heterostructures in the range of 60 Hz-5 MHz is investigated at temperatures from 77 to 300 K. It is found that temperature lowering and test frequency increase lead to the similar changes in obtained apparent carrier distributions. It is shown that commonly used conditions for capacitance-voltage profiling of InGaN/GaN LEDs correspond to an intermediate case between low- and high-frequency capacitance approximations. At all temperatures investigated, the edge low-frequency capacitance-voltage profiles are experimentally reached and found to be identical. The process of attainment of equilibrium of the charges in the active region is most likely determined by tunneling of the carriers through the barriers.

36 MATERIALS SCIENCE↗

Improved electron-beam probe for hypersonic flows

Probe uses differentially-pumped drift tube to connect high and low pressure regions thereby allowing higher gas densities to be studied. System uses higher beam voltages (50 kV) and currents (1 mA delivered to gas), and extends boundary layer penetration up to 15.2 cm, and test duration to one hour.

Mcronald, A. D.↗

Development of the VOLT-A shuttle experiment

The NASA Lewis Research Center (LeRC) is investigating potential problems associated with the operation of high voltage solar cell arrays in the space plasma environment. At high voltages, interactions between the solar array and the space plasma could result in unacceptable levels of electrical discharge (arcing) and/or parasitic losses (current drains from the array to the plasma). The objective of the Voltage Operating Limit Tests (VOLT-A) Shuttle bay experiment is to characterize space plasma/solar cell panel interactions in low earth orbit. VOLT-A consists of an experiment plate subassembly which contains four solar panels, an electronics subassembly and a Langmuir probe subassembly mounted on an MPESS carrier. During a given 8.25 hour data taking period (5-1/2 continuous orbits), the solar panels, which represent state-of-the-art solar cell technologies, will be sequentially subjected to bias voltages in steps ranging from minus 626 V to plus 313 V. Appropriate measurements will be made at each voltage to characterize arcing and parasitic losses. Corresponding measurements of the plasma environment (plasma density, electron temperature and neutral density) will also be made. Data will be recorded on an on-board tape recorder for subsequent data reduction and analysis.

Bifano, W. J.↗

Development of the VOLT-A Shuttle experiment

The NASA Lewis Research Center (LeRC) is investigating potential problems associated with the operation of high voltage solar cell arrays in the space plasma environment. At high voltages, interactions between the solar array and the space plasma could result in unacceptable levels of electrical discharge (arcing) and/or parasitic losses (current drains from the array to the plasma). The objective of the Voltage Operating Limit Tests (VOLT-A) Shuttle bay experiment is to characterize space plasma/solar cell panel interactions in low earth orbit. VOLT-A consists of an experiment plate subassembly which contains four solar panels, an electronics subassembly and a Langmuir probe subassembly mounted on an MPESS carrier. During a given 8.25 hour data taking period (5-1/2 continuous orbits), the solar panels, which represent state-of-the-art solar cell technologies, will be sequentially subjected to bias voltages in steps ranging from minus 626 V to plus 313 V. Appropriate measurements will be made at each voltage to characterize arcing and parasitic losses. Corresponding measurements of the plasma environment (plasma density, electron temperature and neutral density) will also be made. Data will be recorded on an on-board tape recorder for subsequent data reduction and analysis.

Bifano, William J.↗

The Solar Array Module Plasma Interactions Experiment (SAMPIE) - A Shuttle-based plasma interactions experiment

The Solar Array Module Plasma Interactions Experiment (SAMPIE), an approved Shuttle space flight experiment with a tentative launch date in July 1993, is intended to investigate plasma interactions of high-voltage space power systems. Solar cell modules, representing several technologies, will be biased to high voltages to characterize both arcing (negative potential) and current collection (positive potential). Other solar modules, specially modified in accordance with current theories of arcing and breakdown, will demonstrate the possibility of arc suppression. Finally, several additional test specimens will be included to study the basic nature of these interactions. The authors describe the rationale for the space flight experiment, the measurements to be made, the significance of the expected results, and the current design status of the flight hardware.

Wald, Lawrence W.↗

Photovoltaic Plasma Interaction Test 2

The International Space Station (ISS) program is developing a plasma contactor to mitigate the harmful effects of charge collection on the station's large photovoltaic arrays. The purpose of the present test was to examine the effects of charge collection on the solar array electrical circuit and to verify the effectiveness of the plasma contactor. The results showed that the plasma contactor was able to eliminate structure arcing for any array output voltage. However, the current requirements of the plasma contactor were higher than those for prior testing and predicted by analysis. Three possible causes for this excess current demand are discussed. The most likely appeared to be a high local pressure on or very near the surface of the array as a result of vacuum tank conditions. Therefore, in actual space conditions, the plasma contactor should work as predicted.

Kaufman, Bradford A.↗

A Force to Reckon With

Through a licensing agreement with NASA, Face International Corporation has successfully commercialized ferroelectric actuator/sensor technology developed at Langley Research Center. Face International manufactures both ferroelectric actuators and sensors under the trademark "Thunder" (Thin Layer Composite Unimorph Ferroelectric Driver and Sensor). As actuators the Thunder technology provides a high level of movement not seen before in piezoelectric devices. Crystal structures generate electricity when stressed and move when voltage is applied. As sensors, the technology can be used in such applications as microphones, non-destructive testing, and vibration sensing. Thunder technology is being researched as a noise reduction device for aircraft engines. The technology is durable enough to be used in harsh environments, making it applicable to many commercial applications.

Source record↗

MAP Propulsion System Thermal Design

The propulsion system of the Microwave Anisotropy Probe (MAP) had stringent requirements that made the thermal design unique. To meet instrument stability requirements the system had to be designed to keep temperatures of all components within acceptable limits without heater cycling. Although the spacecraft remains at a fixed 22 sun angle at L2, the variations in solar constant, property degradation, and bus voltage range all significantly affect the temperature. Large portions of the fuel lines are external to the structure and all components are mounted to non-conductive composite structure. These two facts made the sensitivity to the MLI effective emissivity and bus temperature very high. Approximately two years prior to launch the propulsion system was redesigned to meet MAP requirements. The new design utilized hardware that was already installed in order to meet schedule constraints. The spacecraft design and the thermal requirements were changed to compensate for inadequacies of the existing hardware. The propulsion system consists of fuel lines, fill and drain lines/valve, eight thrusters, a HXCM, and a propulsion tank. A voltage regulator was added to keep critical components within limits. Software was developed to control the operational heaters. Trim resistors were put in series with each operational heater circuits and the tank survival heater. A highly sophisticated test program, which included real time model correlation, was developed to determine trim resistors sizes. These trim resistors were installed during a chamber break and verified during thermal balance testing.

Mosier, Carol L.↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

36 MATERIALS SCIENCE↗

Roles of temperature, materials, and domain inversion in high-performance, low-bias-drift thin film lithium niobate blue light modulators

We demonstrate a thin film lithium niobate electro-optic modulator operating at 456 nm with an RF voltage-length product of 0.38 V-cm and a bandwidth of 6.9 GHz. We test the dielectric relaxation of the modulator with sweeps of temperature and optical input power, and compare equivalent modulators with electrode materials of Cr-Au, Ti-Au and Al in terms of bias stability and current-voltage characteristics. We demonstrate bias stability over at least 8 hours with Al devices, and show relationships between drift, I-V characteristics and ferroelectric domain switching.

Celik, Oguz Tolga (ORCID:0000000264542306)↗

Perovskite Sr2Fe1.5Mo0.5O6-δ as electrode materials for symmetrical solid oxide electrolysis cells

Perovskite Sr2Fe1.5Mo0.5O6-δ (SFM) has been successfully prepared by a microwave-assisted combustion method in air and employed as both anode and cathode in symmetrical solid oxide electrolysis cells (SOECs) for hydrogen production for the first time in this work. Influence of cell operating temperature, absolute humidity (AH) as well as applied direct current (DC) on the impedance of single cells with the configuration of SFM|La0.9Sr0.1Ga0.8Mg0.2O3 (LSGM)|SFM has been evaluated. Under open circuit conditions and 60 vol.% AH, the cell polarization resistance, RP is as low as 0.26 Ω cm2 at 900 °C. An electrolysis current of 0.88 A cm-2 and a hydrogen production rate as high as 380 mL cm-2 h have been achieved at 900 °C with an electrolysis voltage of 1.3 V and 60 vol.% AH. Further, the cell has demonstrated good stability in the long-term steam electrolysis test. The results showed that the cell electrolysis performance was even better than that of the reported strontium doped lanthanum manganite (LSM) – yttria stabilized zirconia (YSZ)|YSZ|Ni–YSZ cell, indicating that SFM could be a very promising electrode material for the practical application of SOEC technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new approach to the design of surface subsystems of polymeric insulators for HV and MV apparatus under AC voltage

The design of high voltage and medium voltage AC and DC standoff insulators, and, in general, of insulation systems where surface and interface properties are predominant factors, is based on specifications and standards that rely upon long-term experiences and lab testing. Surface insulating properties depend on electrical and thermal stresses, besides environmental factors, and the inception of extrinsic ageing phenomena, such as partial discharges, can be already a cause of reduced reliability and premature failure (for organic insulating materials). An innovative approach, based on field simulation, discharge modelling, and partial discharge inception measurements is presented by the authors, which can establish a solid basis to optimise insulation design for any type of supply voltage waveform. This method, the three-leg approach, is applied here to a cable system under AC sinusoidal voltage, but it can work for any type of insulation system, such as bushings, switch gears, transformers, rotating machines, and power electronics boards.

42 ENGINEERING↗

Converter-Based Emulation of Battery Energy Storage Systems (BESS) for Grid Applications

Battery energy storage systems (BESSs) tend to be too costly, restrictive, and require high maintenance for experimental use, but power system tests often need their representation. As a solution, we propose an all-in-one, reconfigurable BESS emulation tool for grid applications that only requires one three-phase voltage-source converter. This emulator provides chemistry-specific battery behavior like previous work, but it also includes the BESS's power electronics interface and control as well as automatic frequency and voltage support functions for the attached power system. Thus, it allows simple, plug-and-play BESS emulation for grid applications. Here, this paper details the construction, verification, and use of the BESS emulator in an existing grid testbed and concludes that it provides an inexpensive, easy-to-use alternative to using real BESSs in power system experiments.

25 ENERGY STORAGE↗