Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen solid polymer electrolyte (SPE) fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. These solid electrolyte devices have been under continuous development for over 30 years. This experience has resulted in a demonstrated ten-year SPE cell life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluoride loss rates and average expected ultimate cell life. This relationship is shown. Several features have been introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability has been demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density.

Baldwin, R.↗

The NASA space power technology program

NASA has a broad technology program in the field of space power. This paper describes that program, including the roles and responsibilities of the various NASA field centers and major contractors. In the power source area, the paper discusses the SP-100 Space Nuclear Power Project, which has been under way for about seven years and is making substantial progress toward development of components for a 100-kilowatt power system that can be scaled to other sizes. This system is a candidate power source for nuclear electric propulsion, as well as for a power plant for a lunar base. In the energy storage area, the paper describes NASA's battery- and fuel-cell development programs. NASA is actively working on NiCd, NiH2, and lithium batteries. A status update is also given on a U.S. Air Force-sponsored program to develop a large (150 ampere-hour) lithium-thionyl chloride battery for the Centaur upper-stage launch vehicle. Finally, the area of power management and distribution (PMAD) is addressed, including power system components such as solid-state switches and power integrated circuits. Automated load management and other computer-controlled functions offer considerable payoffs. The state of the art in space power is described, along with NASA's medium- and long-term goals in the area.

Stephenson, R. Rhoads↗

Thermal Modeling and Correlation of the Space Environments Complex Vacuum Chamber and Cryoshroud

From Presentation: Formerly known as the Space Power Facility (SPF) Located at Plum Brook Station in Sandusky, OH -- Houses large-scale test facilities including the Space Simulation Vacuum Chamber -- Largest vacuum chamber in the world -- 100 ft diameter, 122 ft tall -- Cryoshroud operates between -250 °F and +140 °F -- To be used for Orion EM-1 thermal vacuum test -- Thermal Desktop model of vacuum chamber, cryoshroud, mechanical ground support equipment (MGSE) including fluid model of GN2 -- Primary uses: Predict MGSE temperatures; Predict heat load on GN2 system -- Includes 96 TD Temperature Measures that represent test thermocouples -- Steady state correlation with 3 tests: 2 hot; 1 cold -- Two ISTs performed with no MGSE inside the cryoshroud: Insulated test: operated at 170 °F for 37 hours; Uninsulated test: operated at 170 °F for 14 days -- Only cryoshroud thermocouples were installed

Thermal modeling↗

Modelling Concentrating Solar Power with Thermal Energy Storage for Integration Studies (Presentation)

Concentrating solar power with thermal energy storage (CSP-TES) can provide multiple benefits to the grid, including low marginal cost energy and the ability to levelize load, provide operating reserves, and provide firm capacity. It is challenging to properly value the integration of CSP because of the complicated nature of this technology. Unlike completely dispatchable fossil sources, CSP is a limited energy resource, depending on the hourly and daily supply of solar energy. To optimize the use of this limited energy, CSP-TES must be implemented in a production cost model with multiple decision variables for the operation of the CSP-TES plant. We develop and implement a CSP-TES plant in a production cost model that accurately characterizes the three main components of the plant: solar field, storage tank, and power block. We show the effect of various modelling simplifications on the value of CSP, including: scheduled versus optimized dispatch from the storage tank and energy-only operation versus co-optimization with ancillary services.

14 SOLAR ENERGY↗

Modelling Concentrating Solar Power with Thermal Energy Storage for Integration Studies: Preprint

Concentrating solar power with thermal energy storage (CSP-TES) can provide multiple benefits to the grid, including low marginal cost energy and the ability to levelize load, provide operating reserves, and provide firm capacity. It is challenging to properly value the integration of CSP because of the complicated nature of this technology. Unlike completely dispatchable fossil sources, CSP is a limited energy resource, depending on the hourly and daily supply of solar energy. To optimize the use of this limited energy, CSP-TES must be implemented in a production cost model with multiple decision variables for the operation of the CSP-TES plant. We develop and implement a CSP-TES plant in a production cost model that accurately characterizes the three main components of the plant: solar field, storage tank, and power block. We show the effect of various modelling simplifications on the value of CSP, including: scheduled versus optimized dispatch from the storage tank and energy-only operation versus co-optimization with ancillary services.

14 SOLAR ENERGY↗

Thermomechanical Characterization and Analysis of Insulation Materials for Nuclear-Based Space Power Systems

Testing was carried out to characterize and predict the long-term thermomechanical properties of various thermal insulation materials for use in nuclear-based space power systems. In particular, the high temperature compressive strength and stress relaxation behavior of these materials under vacuum or an inert atmosphere and up to 950 C were evaluated under either isothermal conditions or under various thermal gradients for test times of over two years. Several tests subjected to thermal gradient conditions were also evaluated for changes in strain due to cooling or heating events. Other testing of these materials included evaluation of their response to lateral (as opposed to axial) loads, their response to triaxial loading conditions, thermal shock behavior of these materials, and shrinkage effects in these materials due to elevated temperature exposure. Additionally, finite element and mathematical models were formulated to predict the mechanical behavior exhibited by these materials out to 35,000 hours (4 years) based on this testing. This paper will summarize the design and construction of unique test equipment to carry out this testing, along with the results of the testing and the subsequent modeling.

NESDPS Office of Nuclear Energy Space and Defense ↗

Quantifying Solar PV Variability at Multiple Timescales for Power Systems Studies: Preprint

Increasing penetration of solar photovoltaics (PV) has concerned power system operators about their ability to balance load and generation over multiple timescales and maintain acceptable frequency profile because of the variability and uncertainty associated with solar PV. This paper focuses on developing metrics to quantify solar PV variability at multiple temporal scales ranging from seconds to an hour to help power system operators and planners better understand and account for solar PV variability under high solar PV penetration. Fourier coefficients of solar irradiation spectrum and average size of solar irradiation ramps over a day are the two metrics that are used to quantity the variability. It is shown that by using the two metrics the days with highest and lowest solar irradiation variability can be identified, which is useful information for operations planning or long-term power system planning studies. The key findings of the paper are (i) single sensor-based variability quantification can significantly exaggerate the variability of a solar PV plant, particularly at seconds to 1-min temporal resolution, (ii) at 1-minute or lower temporal resolutions, single sensor-based variability quantification of an entire plant can be fairly accurate, with the accuracy increasing as the temporal resolution reduces from 1-minute to 1-hour, (iii) at each 1-minute and lower temporal resolutions, maximum solar irradiation ramps appear to be independent of the geographical location of the sensor, and (iv) significant reduction in solar PV plant variability over a region with multiple plants is possible at all temporal scales, but more high quality, high temporal resolution data is needed to quantify the reduction with high confidence.

photovoltaics↗

Laboratory Experiments Examining the Effect of Thermal and Mechanical Processes on Hydraulic Transmissivity Evolution

Using laboratory slide-hold-slide experiments, at temperatures from 22 to 200 degrees C, to examine effects of fracture reactivation and quasi-static loading on the evolution of fluid transport properties of simulated fractures in Westerly granite. At all temperatures, the in-plane hydraulic transmissivity consistently decays during hold periods resulting in an overall reduction in transmissivity. During the first three to fifteen hours of an experiment, transmissivity decreases rapidly due to the generation of wear products, development of a sliding surface, and compaction of the resulting gouge. Once the sliding surface has developed, the long-term transmissivity decay rate at 22 and 100 degrees C is significantly lower than the transmissivity decay rate during the initial 3-15 hours of the experiment. However, at 200 degrees C, the decay of hydraulic transmissivity remains high throughout the experiment. The long-term decay of hydraulic transmissivity can be fitted with a power law model with more rapid reduction of hydraulic transmissivity at higher temperature. Periods of sliding on the fracture surface result in transient increases in the transmissivity, due to shear dilation, as is expected for Coulomb materials. These transients are superimposed on the long-term decay. When sliding ceases and a new hold period commences, there is a rapid reduction in transmissivity and return to the long-term rate of transmissivity decay. The rate of decay of the transmissivity transients is inversely correlated with temperature, in contrast to the long-term decay and the expected behavior for processes like subcritical crack growth and indentation creep. The higher decay rates that are observed during the initial 3-15 hours of the tests and following sliding, are associated with times that the porosity of the gouge is expected to be high. The difference in decay rates suggests that when the gouge is driven far from equilibrium by active shearing, densification may be dominated by a different mechanism from long-term compaction.

15 GEOTHERMAL ENERGY↗

Passive Microphonics Mitigation during LCLS-II Cryomodule Testing at Fermilab

The LCLS-II project calls for cryomodule production and testing at both Fermilab and JLab. Due to low beam loading and high cavity quality factor, the designed peak detuning specification is 10 Hz. Initial testing showed peak detuning up to 150 Hz with a complex and varying time-structure, showing both fast (1-2 second) and slow (1-2 hour) drifts in amplitude and spectrum. Extensive warm and cold testing showed Thermoacoustic Oscillations in the cryogenic valves were the primary source of the microphonics. This was mitigated by valve wipers and valve re-plumbing, resulting in a greatly improved cavity detuning environment. Additional modifications were made to the cavity mechanical supports and Fermilab test stand to improve detuning performance. These modifications and testing results will be presented.

43 PARTICLE ACCELERATORS↗

Summary of Previous Mechanical Test Data on ODS Alloys 14YWT and OFRAC up to 1000ºC

The Nanostructured Ferritic Alloys (NFA) 14YWT and OFRAC were developed for future fission and fusion nuclear energy reactors requiring high-temperature mechanical properties that are tolerant to extreme neutron irradiation environments. The NFA contain a high concentration of Ti-, Y- and O-enriched nanoclusters (NC) and ultra-fine grains to achieve high temperature strength and creep properties and high sink strength for trapping irradiation induced point defects to minimize hardening and swelling and transmutated He atoms to form intragranular nano-size bubbles that prevent formation of coarse bubbles on grain boundaries that cause embrittlement. The mechanical properties of 14YWT and OFRAC have been acquired from tensile and creep tests conducted in the past at Oak Ridge National Laboratory. The development of 14YWT started in 2000, resulting in the production of numerous heats. Tensile properties were obtained from eleven heats of 14YWT from room temperature to 800ºC. Tensile data for the SM10 heat of 14YWT was extended to 1,000ºC. Initial development of OFRAC occurred in 2016. Tensile tests conducted from room temperature to 800ºC revealed similar properties of OFRAC with those obtained from the newer generation of 14YWT heats. The creep properties of 14YWT-SM10 evaluated using constant stress tensile and load time-to-failure tests at 800ºC showed low minimum creep rates with stresses of 200 and 100 MPa. The single time-to-failure test of 14YWT-SM10 at 800ºC and 100 MPa was terminated after 20,357 hours with no specimen failure and a low creep strain of ~0.24 %. The creep properties of OFRAC determined from strain-rate jump tests at were similar those of 14YWT-SM10. The stress exponent for 14YWT and OFRAC at 800ºC are similar and are consistent with threshold stress behavior. Since both 14YWT and OFRAC are candidates for fuel cladding in future fast reactors, several fabrication studies were recently conducted and have successfully demonstrated that thin wall tubes can be fabricated from 14YWT and OFRAC by cold pilger rolling and high precision tube rolling. The high temperature mechanical properties and feasibility of fabricating thin wall tubes make 14YWT and OFRAC candidates for application as heat pipes in advanced micro-reactors. The purpose of this report is to summarize the previously obtained tensile and creep data at temperatures up to 1000ºC for NFA 14YWT and OFRAC that have been acquired over the past 20 years at ORNL.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Temperature Resin Matrix Composites for Aerospace Structures

Accomplishments and the outlook for graphite-polyimide composite structures are briefly outlined. Laminates, skin-stiffened and honeycomb sandwich panels, chopped fiber moldings, and structural components were fabricated with Celion/LARC-160 and Celion/PMR-15 composite materials. Interlaminar shear and flexure strength data obtained on as-fabricated specimens and specimens that were exposed for 125 hours at 589 K indicate that epoxy sized and polyimide sized Celion graphite fibers exhibit essentially the same behavior in a PMR-15 matrix composite. Analyses and tests of graphite-polyimide compression and shear panels indicate that utilization in moderately loaded applications offers the potential for achieving a 30 to 50 percent reduction in structural mass compared to conventional aluminum panels. Data on effects of moisture, temperature, thermal cycling, and shuttle fluids on mechanical properties indicate that both LARC-160 and PMR-15 are suitable matrix materials for a graphite-polyimide aft body flap. No technical road blocks to building a graphite-polyimide composite aft body flap are identified.

Davis, J. G., Jr.↗

In-flight structural dynamic characteristics of the XV-15 tilt rotor research aircraft

The XV-15 tilt rotor research aircraft has recently completed the contractor flight test program at the Bell Helicopter Textron Flight Research Center, Arlington, Texas. During these development and envelope expansion flights (60 flight hours, 140 flights), the aircraft has been tested up to a maximum true airspeed of 557 km/h (346 mph, 301 knts). Results of the structural characteristics obtained during this testing are presented. Included is a discussion concerning the rotor and airframe loads, natural frequency placements, airframe control system interaction, and wing-rotor-pylon aeroelastic stability. Measured data are compared with predicted values for many cases.

Bilger, J. M.↗

Ion thruster system (8-cm) cyclic endurance test

This report describes the qualification test of an Engineering-Model 5-mN-thrust 8-cm-diameter mercury ion thruster which is representative of the Ion Auxiliary Propulsion System (IAPS) thrusters. Two of these thrusters are scheduled for future flight test. The cyclic endurance test described herein was a ground-based test performed in a vacuum facility with a liquid-nitrogen-cooled cryo-surface and a frozen mercury target. The Power Electronics Unit, Beam Shield, Gimal, and Propellant Tank that were used with the thruster in the endurance test are also similar to those of the IAPS. The IAPS thruster that will undergo the longest beam-on-time during the actual space test will be subjected to 7,055 hours of beam-on-time and 2,557 cycles during the flight test. The endurance test was successfully concluded when the mercury in the IAPS Propellant Tank was consumed. At that time, 8,471 hours of beam-on-time and 599 cycles had been accumulated. Subsequent post-test-evaluation operations were performed (without breaking vacuum) which extended the test values to 652 cycles and 9,489 hours of beam-on-time. The Power Electronic Unit (PEU) and thruster were in the same vacuum chamber throughout the test. The PEU accumulated 10,268 hr of test time with high voltage applied to the operating thruster or dummy load.

Dulgeroff, C. R.↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.

Baldwin, R.↗

Room Temperature Characterization of a Magnetic Bearing for Turbomachinery

Open loop, experimental force and power measurements of a three-axis, radial, heteropolar magnetic bearing at room temperature for rotor speeds up to 20,000 RPM are presented in this paper. The bearing, NASA Glenn Research Center's and Texas A&M's third generation high temperature magnetic bearing, was designed to operate in a 1000 F (540 C) environment and was primarily optimized for maximum load capacity. The experimentally measured force produced by one C-core of this bearing was 630 lb. (2.8 kN) at 16 A, while a load of 650 lbs (2.89 kN) was predicted at 16 A using 1D circuit analysis. The maximum predicted radial load for one of the three axes is 1,440 lbs (6.41 kN) at room temperature. The maximum measured load of an axis was 1050 lbs. (4.73 kN). Results of test under rotating conditions showed that rotor speed has a negligible effect on the bearing's load capacity. A single C-core required approximately 70 W of power to generate 300 lb (1.34 kN) of magnetic force. The room temperature data presented was measured after three thermal cycles up to 1000 F (540 C), totaling six hours at elevated temperatures.

Montague, Gerald↗

Building Demand Flexibility: Grid Service Value of Future Market Entrants

The building sector is an important source of demand-side flexibility that is crucial for renewable energy integration in the future power systems. The grid service value of building flexibility, especially that which provides load shifting, has not been analyzed for the United States. We use a technology-agnostic approach based on detailed grid expansion and production cost modeling results to evaluate the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. We find the monthly mean of building flexibility has a range of 0-38 cents/kWh-day, depending on the original usage hour, month, region, building flexibility parameters, and grid scenario. The daily value consists of the highest-value hour each day across all the scenarios has a range of 0-620 cents/kWh-day. The results are provided in an open database for users to obtain the values of specific technologies based on what services can be provided, when, and in what quantities.

30 DIRECT ENERGY CONVERSION↗

Capacity Value of Concentrating Solar Power Plants

This study estimates the capacity value of a concentrating solar power (CSP) plant at a variety of locations within the western United States. This is done by optimizing the operation of the CSP plant and by using the effective load carrying capability (ELCC) metric, which is a standard reliability-based capacity value estimation technique. Although the ELCC metric is the most accurate estimationtechnique, we show that a simpler capacity-factor-based approximation method can closely estimate the ELCC value. Without storage, the capacity value of CSP plants varies widely depending on the year and solar multiple. The average capacity value of plants evaluated ranged from 45%?90% with a solar multiple range of 1.0-1.5. When introducing thermal energy storage (TES), the capacity value ofthe CSP plant is more difficult to estimate since one must account for energy in storage. We apply a capacity-factor-based technique under two different market settings: an energy-only market and an energy and capacity market. Our results show that adding TES to a CSP plant can increase its capacity value significantly at all of the locations. Adding a single hour of TES significantly increasesthe capacity value above the no-TES case, and with four hours of storage or more, the average capacity value at all locations exceeds 90%.

14 SOLAR ENERGY↗

Achieving high hydrogen productivities of 20 L/L-day via microbial electrolysis of corn stover fermentation products

Microbial electrolysis cells have the potential to generate renewable hydrogen from underused waste streams, however current devices have not reached very large productivity targets using real waste products at any scale. This study used a waste from fermented corn stover known as corn stover fermentation product to reach performance metrics that could be commercialized, if adequately scaled. Average current densities in MECs with mature biofilms reached 17.9 +/- 1.6 A/m 2 at an organic loading rate of 30 grams of chemical oxygen demand per liter of anode volume per day (g/L-day), reaching a maximum current density of 27.2 +/- 2.9 A/m 2 . Hydrogen productivities reached 20.2 +/- 2.0 L of H 2 per L anode volume per day (L/L-day). These represent the highest current densities and highest hydrogen productivities using a complex feedstock in a microbial electrolysis cell. Organic acids and sugars present in untreated substrate were converted at high percentages in MECs, with most above 90% conversion, at organic loading rates of 10, 20, and 30 g/L-day. The effect of periodic high liquid flow rates through the anode on performance was assessed. These tests, called pulsing, showed that hydrogen productivities and current densities increased most dramatically as flow was pulsed every hour at a baseline flow rate of 0.3 mL/min. These productivities show promise for high performance systems, if adequate scale up can be achieved.