Application Programming in AWIPS II

Since its inception almost 8 years ago, NASA's Short-term Prediction Research and Transition (SPoRT) Center has integrated NASA data into the National Weather Service's decision support system (DSS) the Advanced Weather Interactive Processing System (AWIPS). SPoRT has, in some instances, had to shape and transform data sets into various formats and manipulate configurations to visualize them in AWIPS. With the advent of the next generation of DSS, AWIPS II, developers will be able to develop their own plugins to handle any type of data. Raytheon is developing AWIPS II to be a more extensible package written mainly in Java, and built around a Service Oriented Architecture. A plugin architecture will allow users to install their own code modules, and (if all the rules have been properly followed) they will work hand-in-hand with AWIPS II as if it were originally built in. Users can bring in new datasets with existing plugins, tweak plugins to handle a nuance or desired new functionality, or create an entirely new visualization layout for a new dataset. SPoRT is developing plugins to ensure its existing NASA data will be ready for AWIPS II when it is delivered, and to prepare for the future of new instruments on upcoming satellites.

Smit, Matt↗

Handheld Multi-Gas Meters Assessment Report

Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

47 OTHER INSTRUMENTATION↗

Improved Airborne System for Sensing Wildfires

The Wildfire Airborne Sensing Program (WASP) is engaged in a continuing effort to develop an improved airborne instrumentation system for sensing wildfires. The system could also be used for other aerial-imaging applications, including mapping and military surveillance. Unlike prior airborne fire-detection instrumentation systems, the WASP system would not be based on custom-made multispectral line scanners and associated custom- made complex optomechanical servomechanisms, sensors, readout circuitry, and packaging. Instead, the WASP system would be based on commercial off-the-shelf (COTS) equipment that would include (1) three or four electronic cameras (one for each of three or four wavelength bands) instead of a multispectral line scanner; (2) all associated drive and readout electronics; (3) a camera-pointing gimbal; (4) an inertial measurement unit (IMU) and a Global Positioning System (GPS) receiver for measuring the position, velocity, and orientation of the aircraft; and (5) a data-acquisition subsystem. It would be necessary to custom-develop an integrated sensor optical-bench assembly, a sensor-management subsystem, and software. The use of mostly COTS equipment is intended to reduce development time and cost, relative to those of prior systems.

McKeown, Donald↗

Imaging graphite in air by scanning tunneling microscopy - Role of the tip

Atomically resolved images of highly oriented pyrolytic graphite (HOPG) in air at point contact have been obtained. Direct contact between tip and sample or contact through a contamination layer provides a conduction mechanism in addition to the exponential tunneling mechanism responsible for scanning tunneling microscopy (STM) imaging. Current-voltage (I-V) spectra were obtained while scanning in the current imaging mode with the feedback circuit interrupted in order to study the graphite imaging mechanism. Multiple tunneling tips are probably responsible for images without the expected hexagonal or trigonal symmetry. The observations indicate that the use of HOPG for testing and calibration of STM instrumentation may be misleading.

Colton, R. J.↗

Astrometric performance characteristics of the Hubble Space Telescope fine guidance sensors

Each of the three fine guidance sensors for the Hubble Space Telescope constitutes a sixth science instrument to be used for astrometry. We detail the tests and results used in choosing one of the three sensors to be the prime astrometer. The Astrometry Science Team has chosen Fine Guidance Sensor (FGS) 3. FGS 3 produces position measurements on a star with V = 17 with a peraxis precision of 0.003 arcsec. The interferometer response function should permit double-star astrometry at least down to V = 16 for the central region of FGS 3. In a 10-h test of the stability of POS-mode astrometric measurements made in FGS 3, we found no scale or orientation variations greater than two parts in 100,000. During this same time period, we found no statistically significant systematic guide-star radial separation changes. Spacecraft jitter is found to be the prime determinant of astrometry success or failure.

Benedict, G. F.↗

Lunar Transport Vehicle Occupant Protection Requirements

The National Aeronautics and Space Administration (NASA) is preparing for future Artemis missions that will return humans to the lunar surface. A critical piece of these future missions is the Lunar Transport Vehicle (LTV), a transportation device to be used on the lunar surface. A vehicular method of transportation will allow for longer duration missions with increased capabilities to conduct research and transport soil, geological samples, or other materials of interest. Multiple missions to the lunar surface throughout the Apollo program also deployed the use of a lunar vehicle, known as the Lunar Roving Vehicle (LRV). The LRV was used during three of the six Apollo missions that successfully landed humans on the moon. Unfortunately, the LRV did not have any onboard instrumentation, and a large portion of the lunar performance evaluation relied on photographic documentation and crew reports. Therefore, we do not know the actual accelerations and vibrations experienced by the crew when driving on the lunar surface. The objective of this document is to provide occupant protection guidance when designing the LTV. Acceleration, vibration, and jerk metrics imparted by the vehicle relative to the occupant shall not exceed those listed in this document. At the time of writing of these requirements, much of the LTV design is unknown. This document details requirements based on multiple possible restraint configurations and crew orientations.

Kevin R. Dolick↗

Photoelectrochemically driven self-assembly method

Various technologies described herein pertain to assembling electronic devices into a microsystem. The electronic devices are disposed in a solution. Light can be applied to the electronic devices in the solution. The electronic devices can generate currents responsive to the light applied to the electronic devices in the solution, and the currents can cause electrochemical reactions that functionalize regions on surfaces of the electronic devices. Additionally or alternatively, the light applied to the electronic devices in the solution can cause the electronic devices to generate electric fields, which can orient the electronic devices and/or induce movement of the electronic devices with respect to a receiving substrate. Further, electrodes on a receiving substrate can be biased to attract and form connections with the electronic devices having the functionalized regions on the surfaces. The microsystem can include the receiving substrate and the electronic devices connected to the receiving substrate.

42 ENGINEERING↗

Development and Test of High Temperature Surface Acoustic Wave Gas Sensors

The demand for sensors in hostile environments, such as power plant environments, aerospace environments, oil and gas extraction, and high-temperature metallurgy environments, has risen over the past decades in a continuous attempt to increase process control, improve energy and process efficiency in production, reduce operational and maintenance costs, increase safety, and perform condition-based maintenance in equipment and structures operating in high-temperature harsh-environment conditions. The increased reliability, improved performance, and development of new sensors and networks with a multitude of components, especially wireless networks, are the target for operation in harsh environments. Gas sensors, in particular H2 sensors, operating above 200 C are required in the instrumentation, process control and general safety of a number of industries including coal, natural gas, and nuclear power generation facilities, the aerospace and automotive industries, metallurgical production and defense-related applications. The surface acoustic wave (SAW) platform is a particularly promising option for high-temperature, harsh-environment gas sensing applications since the platform exhibits advantages, such as battery-free and wireless operation, small size, possibility for scale production using well-developed technologies from the semiconductor industry, and low cost of installation and operation. In this work, one-port SAW resonators (SAWRs) operating along five different orientations on a commercially available langasite (LGS) wafer employing Pt-Al2O3 electrodes and reflectors were designed, fabricated, and used as high-temperature H2 sensors. Two of the selected orientations were predicted and confirmed to have temperature-compensated operation above 150 C. A gas sensor test setup was developed, capable of gas cycling between N2, O2 and N2/H2 mixtures under extended high-temperature periods (up to 650 C for over 20 hours). Thin film Pt-Al2O3 was used as the electrode material for the transducers and reflectors capable of high-temperature operation, and also as H2 sensing film. In addition, yttria-stabilized zirconia (YSZ) thin films with Pt decoration were tested as sensing films aimed to enhance the SAWR sensor response to H2. The SAW devices were monitored in excess of 1700 hours in real-time during gas cycling sequences up to 600 C, leading to the following findings: i) the Pt-Al2O3 electrodes performed better for H2 sensing than the Pt-decorated YSZ sensing film, showing as much as 50% higher frequency variation response in the 200 C to 400 C range; ii) different crystallographic orientations operating on the same LGS wafer experienced different responses to H2 exposures up to 500 C; iii) the surface oxidation state of the SAWR sensors was shown to have an important impact on subsequent H2 exposure responses. In addition, a sensor system employing two LGS SAWRs, aligned along two different orientations, has been developed to simultaneously determine H2 presence and temperature. Finally, wireless interrogation of a SAWR sensor was successful within the gas cycling test fixture, and successful wireless H2 detection was achieved above 400 C.

Ayes Moncada, Armando↗

The Impact of the AIRS Spatial Response on Channel-to-Channel and Multi-Instrument Data Analyses

The Atmospheric Infrared Sounder (AIRS) measures the infrared spectrum in 2378 channels between 3.7 and 15.4 microns with a very high spectral resolution of approximately 1200. AIRS footprints are approximately 1.1 by 0.6 degrees. Because AIRS is a grating spectrometer, each channel has a unique spatial response. Image rotation due to the scan mirror causes these spatial responses to rotate. In effect, each channel has 90 spatial responses, one for each scene footprint in the scan line. Although the spatial response for most channels is symmetric and nearly uniform, some channels have significantly asymmetric response. This paper reviews and describes the prelaunch measurements that characterized the spatial response functions. Next, it describes the conversion of the ground-based results into footprint-specific response functions valid in flight. Then we describe the postlaunch validation of the measurements, including centroid location, axes orientations, and a check on the full two-dimensional response functions. This latter check involves comparison of AIRS data with that of the Moderate Resolution Imaging Spectrometer (MODIS), which flies on the same platform as AIRS. An important result is that AIRS/MODIS brightness temperature comparisons are significantly improved (scatter reduced) when the AIRS spatial response is explicitly taken into account. Finally, a status report is given on attempts to fully verify the prelaunch measurements by deriving the AIRS spatial response from flight data alone.

preflight calibaration↗

Introduction to Optical Methods for Characterizing Liquid Crystals at Interfaces

This Instructional Review describes methods and underlying principles that can be used to characterize both the orientations assumed spontaneously by liquid crystals (LCs) at interfaces and the strength with which the LCs are held in those orientations (so-called anchoring energies). The application of these methods to several different classes of LC interfaces is described, including solid and aqueous interfaces as well as planar and non-planar interfaces (such as those that define a LC-in-water emulsion droplet). These methods, which enable fundamental studies of the ordering of LCs at polymeric, chemically-functionalized and biomolecular interfaces, are described in this article at a level that can be easily understood by a non-expert reader such as an undergraduate or graduate student. Finally, we focus on optical methods because they are based on instrumentation that is found widely in research and teaching laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stokes polarimetry using analysis of the nonlinear voltage-retardance relationship for liquid-crystal variable retarders

We present a method for using liquid-crystal variable retarders (LCVR’s) with continually varying voltage to measure the Stokes vector of a light beam. The LCVR's are usually employed with fixed retardance values due to the nonlinear voltage-retardance behavior that they show. The nonlinear voltage-retardance relationship is first measured and then a linear fit of the known retardance terms to the detected signal is performed. We use known waveplates (half-wave and quarter-wave) as devices to provide controlled polarization states to the Stokes polarimeter and we use the measured Stokes parameters as functions of the orientation of the axes of the waveplates as an indication of the quality of the polarimeter. Results are compared to a Fourier analysis method that does not take into account the nonlinear voltage-retardance relationship and also to a Fourier analysis method that uses experimental voltage values to give a linear retardance function with time. Also, we present results of simulations for comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SDSS-V Algorithms: Fast, Collision-free Trajectory Planning for Heavily Overlapping Robotic Fiber Positioners

Robotic fiber positioner (RFP) arrays are becoming heavily adopted in wide-field massively multiplexed spectroscopic survey instruments. RFP arrays decrease nightly operational overheads through rapid reconfiguration between fields and exposures. In comparison to similar instruments, SDSS-V has selected a very dense RFP packing scheme where any point in a field is typically accessible to three or more robots. This design provides flexibility in target assignment. However, the task of collisionless trajectory planning is especially challenging. We present two multiagent distributed control strategies that are highly efficient and computationally inexpensive for determining collision-free paths for RFPs in heavily overlapping workspaces. We demonstrate that a reconfiguration path between two arbitrary robot configurations can be efficiently found if a “folded” state, in which all robot arms are retracted and aligned in a lattice-like orientation, is inserted between the initial and final states. Although developed for SDSS-V, the approach we describe is generic and thus applicable to a wide range of RFP designs and layouts. Robotic fiber positioner technology continues to advance rapidly, and in the near future ultra-densely packed RFP designs may be feasible. Our algorithms are especially capable in routing paths in very crowded environments, where we see efficient results even in regimes significantly more crowded than the SDSS-V RFP design.

42 ENGINEERING↗

Observations of the Polar Cap Area During Substorms

The area of the polar cap as a function of local time and substorm phase was measured using images from the Polar Ultraviolet Imager for different interplanetary magnetic field orientations during three substorms in January 1997. We present a new finding that the increase in polar cap area prior to onset and the decrease in the area following it are independent of the strength of the southward component. For one case the polar cap area increased while the southward component of the IMF was no less that -0.5 nT. It was also found that the polar cap boundary is determined by auroral images is strongly influenced by thinning of the oval, decrease in polar cap structures, the poleward expansion of the substorm at midnight and the fading of luminosity below the instrument sensitivity threshold. Generally these effects dominate over the latitudinal motion of the auroral oval at its equatorward edge. These observations have strong implications for models that use the polar cap area to estimate the magnitude of energy storage in the lobe magnetic field and loss during substorms.

Brittnacher, M. J.↗

An Intelligent Strain Gauge with Debond Detection and Temperature Compensation

The harsh rocket propulsion test environment will expose any inadequacies associated with preexisting instrumentation technologies, and the criticality for collecting reliable test data justifies investigating any encountered data anomalies. Novel concepts for improved systems are often conceived during the high scrutiny investigations by individuals with an in-depth knowledge from maintaining critical test operations. The Intelligent Strain Gauge concept was conceived while performing these kinds of activities. However, the novel concepts are often unexplored even if it has the potential for advancing the current state of the art. Maturing these kinds of concepts is often considered to be a tangential development or a research project which are both normally abandoned within the propulsion-oriented environment. It is also difficult to justify these kinds of projects as a facility enhancement because facility developments are only accepted for mature and proven technologies. Fortunately, the CIF program has provided an avenue for bringing the Intelligent Strain Gauge to fruition. Two types of fully functional smart strain gauges capable of performing reliable and sensitive debond detection have been successfully produced. Ordinary gauges are designed to provide test article data and they lack the ability to supply information concerning the gauge itself. A gauge is considered to be a smart gauge when it provides supplementary data relating other relevant attributes for performing diagnostic function or producing enhanced data. The developed strain gauges provide supplementary signals by measuring strain and temperature through embedded Karma and nickel chromium (NiCr) alloy elements. Intelligently interpreting the supplementary data into valuable information can be performed manually, however, integrating this functionality into an automatic system is considered to be an intelligent gauge. This was achieved while maintaining a very low mass. The low mass enables debond detection and temperature compensation to be performed when the gauge is utilized on small test articles. It was also found that the element's mass must be relatively small to avoid overbearing the desired thermal dissipation characteristics. Detecting the degradation of a gauge s bond was reliably achieved by correlating thermal dissipation with the bond s integrity. This was accomplished by precisely coupling a NiCr element with a Karma element for accurately interjecting and quantifying thermal energy. A finite amount of thermal energy is consistently placed in the gauge by electrically powering the NiCr element. The energy will only be temporarily stored before it begins to dissipate into the surrounding structure through the gauge bond. The ability to transmit the energy into the structure becomes greatly inhibited by any discontinuity in the bond s substrate. Therefore, the way the thermal dissipation occurs will reveal even the slightest change in the integrity of the bond.

Jensen, Scott L.↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ellipsometry with polarisation analysis at cryogenic temperatures inside a vacuum chamber

In this paper we describe a new variant of null ellipsometry to determine thicknesses and optical properties of thin films on a substrate at cryogenic temperatures. In the PCSA arrangement of ellipsometry the polarizer and the compensator are placed before the substrate and the analyzer after it. Usually, in the null ellipsometry the polarizer and the analyzer are rotated to find the searched minimum in intensity. In our variant we rotate the polarizer and the compensator instead, both being placed in the incoming beam before the substrate. Therefore the polarisation analysis of the reflected beam can be realized by an analyzer at fixed orientation. We developed this method for investigations of thin cryogenic films inside a vacuum chamber where the analyzer and detector had to be placed inside the cold shield at a temperature of T≈ 90 K close to the substrate. All other optical components were installed at the incoming beam line outside the vacuum chamber, including all components which need to be rotated during the measurements. Our null ellipsometry variant has been tested with condensed krypton films on a highly oriented pyrolytic graphite substrate (HOPG) at a temperature of T≈ 25 K. We show that it is possible to determine the indices of refraction of condensed krypton and of the HOPG substrate as well as thickness of krypton films with reasonable accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystallographic orientation of orthorhombic aragonite using reflection generalized ellipsometry

Here, the 2-modulator generalized ellipsometry microscope (2-MGEM) has been used to study a natural crystal of aragonite. Like its polymorph calcite, aragonite has a large refractive index difference between light polarized parallel to the c-axis and light polarized perpendicular to the c-axis. Unlike calcite, aragonite is orthorhombic, so there is also a very small difference between the refractive indices polarized along the a- and b-directions. As a result, it is not possible to use the 2-MGEM to obtain a definitive map of the optic axis directions of a sample as was possible with calcite, but it is possible to determine approximately the orientation of the c-axis with respect to the surface normal. If the c-axis is in the sample surface plane, it is possible to measure very small deviations of the c-axis direction with an accuracy of ~0.2°. If the c-axis is oriented normal to the sample surface, 2-MGEM data can be used to identify different crystallites due to rotations about the c-axis. For comparison, the orientations of some of the crystallites have also been measured using X-ray Laue and electron beam backscatter diffraction. In addition, spectroscopic generalized ellipsometry measurements have been used to determine the refractive indices of aragonite.

36 MATERIALS SCIENCE↗

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗