Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Plasma studies on electron cyclotron resonance light ion source at CEA/Saclay

By the 90s, the CEA has undertaken to develop the production of intense light ion beams from unconfined ECR plasma. Today, three sources for IPHI, SPIRAL2, and IFMIF projects (respectively, 100 mA of H{sup +}, 8 mA of D{sup +}, and 140 mA of D{sup +}) are installed at CEA/Saclay. In order to improve performances and decrease dimensions of these sources, it is necessary to better understand the mechanisms involved in the production and extraction of particles. As a consequence, theoretical and experimental studies are being carried out. We present a theoretical study based on SOLMAXP, a home-made particle-in-cell code. The aim is to investigate the possibility of reducing the plasma chamber size without loss of beam characteristics. This code has been validated by beam intensity measurements on a permanent magnet based source, producing a proton beam of 30 mA at 40 kV on the test bench BETSI. In order to reduce experimentally the dimensions of plasma chamber, a new source, named ALISES with variable plasma chamber volume, is under assembly.

43 PARTICLE ACCELERATORS↗

Investigation of fringe plasma parameters on a high power rf driven ion source

It has been observed that there are differences between the uncompensated Langmuir probes installed in the upper and lower areas of the rf driven H{sup -} sources at IPP Garching. The two probes often had substantially different floating potentials or ion saturation currents. In an effort to understand the reasons for these differences a Langmuir probe analysis system was used on the probes to collect the full current voltage characteristic. The results show what is likely the formation of an ion-ion plasma. The paper shows the effect of beam extraction and the presence of caesium on the probe characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a new photoelectron spectroscopy instrument combining an electrospray ion source and photoelectron imaging

A new apparatus has been constructed that combines electrospray ionization with a quadrupole mass filter, hexapole ion trap, and velocity-map imaging. The purpose is to record photoelectron images of isolated chromophore anions. To demonstrate the capability of our instrument we have recorded the photodetachment spectra of isolated deprotonated phenol and indole anions. To our knowledge, this is the first time that the photodetachment energy of the deprotonated indole anion has been recorded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of the RF Negative Ion Source Using a Mesh Grid Bias Method

Using a mesh grid bias method for plasma parameter control, volume production of hydrogen negative ions H{sup -} is studied in pure hydrogen rf plasmas. Relationship between the extracted H{sup -} ion currents and plasma parameters is discussed. Both high and low electron temperature T{sub e} plasmas are produced in the separated regions when the grid is negatively biased. In addition, with changing grid potential V{sub g}, values of n{sub e} increase while T{sub e} decrease in their values. The negative ion production depends strongly on the grid potential and related plasma conditions. It is also confirmed that grid bias method is more effective than the so-called magnetic filter method to optimize plasma parameters for H{sup -} production. Production of deuterium negative ions D{sup -} is also studied briefly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The impact of plasma-wall interaction on the gas mixing efficiency in electron cyclotron resonance ion source

It is generally accepted that different effects are necessary to explain the gas mixing method of increasing the output of highly charged ions from an ECRIS. The two most important effects are the mass effect and the dilution effect. Their relative weights have not been determined experimentally yet, but it is generally assumed that the mass effect is dominant in standard ECRIS installations with stainless steel plasma chambers. In order to gain more insight into the physics of the gas mixing effect and in particular on the relevance of the dilution process, we have carried out a study where we have investigated the role of the plasma-wall interaction on the gas mixing effect. In this contribution, we shall discuss Charge state distributions spectra, measured at the Frankfurt ECRIS using different working gases, pure argon, a mixture of argon and oxygen, and argon mixed with neon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developments of fast emittance monitors for ion sources at RCNP

Recently, several developments of low energy beam transport line and its beam diagnostic systems have been performed to improve the injection efficiency of ion beam to azimuthally varying field cyclotron at Research Center for Nuclear Physics, Osaka University. One of those is the fast emittance monitor which can measure within several seconds for the efficient beam development and a Pepper-Pot Emittance Monitor (PPEM) has been developed. The PPEM consists of pepper-pot mask, multichannel plate, fluorescent screen, mirror, and CCD camera. The CCD image is taken via IEEE1394b to a personal computer and analyzed immediately and frequently, and then real time measurement with about 2 Hz has been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multicharged ion source based on Penning-type discharge with electron cyclotron resonance heating by millimeter waves

We suggest a Penning-type discharge as a trigger discharge for fast development of pulsed electron cyclotron resonance plasma. The Penning-type discharge glows at a low pressure as needed. Gyrotron radiation (75 GHz, 200 kW, 1 ms) was used for plasma heating. Fully striped helium ions were demonstrated, average charge of ions in the plasma was {approx_equal} 2. Experiment and calculations show that high charge states of heavier gases require lower initial pressure and longer development time. Only moderate charge states are achievable in this pulsed scheme.

43 PARTICLE ACCELERATORS↗

Operation of an electron-bombardment ion source using various gases

An electron-bombardment ion thruster of the SERT 2 type was operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was similar to that obtained previously with mercury. Mass spectrometer data indicated that the xenon contained no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor because the basic thruster designed was optimized for operation with mercury.

Byers, D. C.↗

Xenon ion sources for space applications

The technology of xenon ion thrusters under development for space-propulsion and plasma-contactor applications is described with particular consideration given to the 1.4-kW Xenon Ion Propulsion Subsystem (XIPS) designed for the upcoming Atmospheric Laboratory for Applications and Science Shuttle-based missions. The 25-cm-diam ion thruster of the XIPS is able to convert input power into thrust-beam power with an efficiency of over 82 percent. The XIPS will be used for satellite stationkeeping and orbit raising and maneuvering and as a plasma contactor. A 1991 flight application is described in which the 25-cm XIPS plasma contactor will be used to stabilize the electrical potential of the Shuttle Orbiter during firings of a 1.5-A electron beam from its payload bay.

Beattie, J. R.↗

Gas field ion source current stability for trimer and single atom terminated W(111) tips

Tungsten W(111) oriented trimer-terminated tips as well as single atom tips, fabricated by a gas and field assisted etching and evaporation process, were investigated with a view to scanning ion microscopy and ion beam writing applications. In particular, ion current stability was studied for helium and neon imaging gases. Large ion current fluctuations from individual atomic sites were observed when a trimer-terminated tip was used for the creation of neon ion beam. However, neon ion current was stable when a single atom tip was employed. No such current oscillations were observed for either a trimer or a single atom tip when imaged with helium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced production of electron cyclotron resonance plasma by exciting selective microwave mode on a large-bore electron cyclotron resonance ion source with permanent magnet

We are constructing a tandem type ECRIS. The first stage is large-bore with cylindrically comb-shaped magnet. We optimize the ion beam current and ion saturation current by a mobile plate tuner. They change by the position of the plate tuner for 2.45 GHz, 11–13 GHz, and multi-frequencies. The peak positions of them are close to the position where the microwave mode forms standing wave between the plate tuner and the extractor. The absorbed powers are estimated for each mode. We show a new guiding principle, which the number of efficient microwave mode should be selected to fit to that of multipole of the comb-shaped magnets. We obtained the excitation of the selective modes using new mobile plate tuner to enhance ECR efficiency.

43 PARTICLE ACCELERATORS↗

The influence of the extraction voltage on the energetic electron population of an electron cyclotron resonance ion source plasma

An influence of the extraction voltage on the high energy slope of bremsstrahlung radiation spectra has been reported in ECRIS experiments, which is not well understood so far. In order to provide more detailed data on this effect, we have measured bremsstrahlung radiation spectra accompanying especially the evolution of highly charge ions (i.e., by monitoring the Ar{sup 14+} charge state) as the extraction voltage is changed from 0 to 20 kV, in dedicated experiments at the Frankfurt 14 GHz-ECRIS.

43 PARTICLE ACCELERATORS↗

Profiles of ion beams and plasma parameters on a multi-frequencies microwaves large bore electron cyclotron resonance ion source with permanent magnets

In order to contribute to various applications of plasma and beams based on an electron cyclotron resonance, a new concept on magnetic field with all magnets on plasma production and confinement has been proposed with enhanced efficiency for broad and dense ion beam. The magnetic field configuration consists of a pair of comb-shaped magnet surrounding plasma chamber cylindrically. Resonance zones corresponding for 2.45 GHz and 11-13 GHz frequencies are positioned at spatially different positions. We launch simultaneously multiplex frequencies microwaves operated individually, try to control profiles of the plasma parameters and the extracted ion beams, and to measure them in detail.

43 PARTICLE ACCELERATORS↗

A cylindrical quadrupole ion trap in combination with an electrospray ion source for gas-phase luminescence and absorption spectroscopy

A relatively simple setup for collection and detection of light emitted from isolated photo-excited molecular ions has been constructed. It benefits from a high collection efficiency of photons, which is accomplished by using a cylindrical ion trap where one end-cap electrode is a mesh grid combined with an aspheric condenser lens. The geometry permits nearly 10% of the emitted light to be collected and, after transmission losses, approximately 5% to be delivered to the entrance of a grating spectrometer equipped with a detector array. The high collection efficiency enables the use of pulsed tunable lasers with low repetition rates (e.g., 20 Hz) instead of continuous wave (cw) lasers or very high repetition rate (e.g., MHz) lasers that are typically used as light sources for gas-phase fluorescence experiments on molecular ions. A hole has been drilled in the cylinder electrode so that a light pulse can interact with the ion cloud in the center of the trap. Simulations indicate that these modifications to the trap do not significantly affect the storage capability and the overall shape of the ion cloud. The overlap between the ion cloud and the laser light is basically 100%, and experimentally >50% of negatively charged chromophore ions are routinely photodepleted. The performance of the setup is illustrated based on fluorescence spectra of several laser dyes, and the quality of these spectra is comparable to those reported by other groups. Finally, by replacing the optical system with a channeltron detector, we demonstrate that the setup can also be used for gas-phase action spectroscopy where either depletion or fragmentation is monitored to provide an indirect measurement on the absorption spectrum of the ion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗