Feasibility Study of Non-Potable Reuse Water for Cooling of Future Supercomputer Infrastructure
No abstract provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract provided.
This report provides a thorough evaluation of technologies and equipment assets that may be effective at mitigating the effects of a wide-area radioactive contamination event and to restore critical functions to the urban environment. Moreover, equipment that could facilitate decontamination efforts during a recovery phase are evaluated. The summary of methods has been critically evaluated in terms of equipment availability, potential advantages and limitations, and research needs in order to justify and predict its efficacy. By ranking the host of techniques, a concise list of those technologies is provided that might be most impactful to a response and recovery effort and how to direct future effort. The totality of this effort and future work anticipates providing early responders and stakeholders with practical guidance information to expedite an effective response and recovery effort and mitigate the potentially devastating effects of a wide-area radioactive contamination event.
This document summarizes the procurement, installation, and commissioning of a scanning electron microscope (SEM) mill produced by Fischione Instruments and a lead-shielded vault for specimen storage in support of Nuclear Science User Facility (NSUF) awards for use in Oak Ridge National Laboratory’s (ORNL) Low Activation Materials Development and Analysis (LAMDA) laboratory. The Model 1061 SEM mill is a tabletop ion milling system for advanced sample preparation of high-quality SEM samples. This device was chosen for its broad range of ion energies allowing for both rapid milling and final polishing of the sample surface. The purchase order with Fischione Instruments was released and awarded by ORNL procurement on September 11, 2018. The instrument was shipped in December of 2018 and was installed in the LAMDA laboratory in March of 2019. During the commissioning of this equipment, electron backscatter diffraction (EBSD) was performed on specimens before and after milling to show the enhanced surface quality. With the purchase of a lead vault dedicated to NSUF library materials co-located in the LAMDA laboratory, the NSUF program will be able to maintain a significant sample library in LAMDA. These specimens will be easily accessible for rapid turnaround experiment (RTE) awards and will reduce the overall cost of year-over-year storage and shipments to and from ORNL hot cell facilities. The contract to fabricate a fourth lead vault dedicated to NSUF specimen storage was awarded by ORNL procurement on August 10, 2018. Installation of the new vault was completed in January of 2019.
This document presents a Tribal Telecom/Internet Service Provider (ISP) internet protocol, version 6 (IPv6) business planning advisory. It includes examples of business areas, services, challenges, benefits, and a vision for the future.
This report summarizes a risk informed, performance-based and technology-inclusive approach to determine source terms for dose related assessments at advanced nuclear facilities. This approach uses a graded process which allows both the non-mechanistic source terms calculation methods, which adopt conservative approaches and assumptions based on known physical and chemical principles, and more importantly the mechanistic source term calculation methods, which consider design-specific scenarios and use best estimate models with uncertainty quantification for a range of licensing basis events (LBEs), to be used for the design and licensing of advanced nuclear technologies. The source terms developed with this graded approach, and radionuclide inventories elsewhere in the facility that are determined during source term analysis, can be used to address licensing issues to support the application processes of 10 CFR Part 50 for a construction permit and operating license or 10 CFR Part 52 for a Combined Operating License (COL), Standard Design Certification, Early Site Permit, Standard Design Approval or Manufacturing License. They can also be used for other purposes including equipment environmental qualification, control room habitability analyses, and assessments of severe accident risks in environmental impact statements. There are many advanced reactor concepts being developed including high temperature gas-cooled reactor (HGTR), sodium-cooled fast reactor (SFR), lead-cooled fast reactor (LFR), molten salt reactor (MSR), micro-reactor, etc. The graded approach presented in this report for source terms determination is, to the extent possible, generic to any of these reactor designs and to future reactor designs. This report provides information on the review of the regulatory foundation for use of conservative bounding source terms as well as event-specific mechanistic source terms for advanced nuclear reactor designs.
Explore the source record for details and available documents.
The risks of long-duration, widespread interruptions (LDWIs) in electrical power are a concern of U.S. regulators, the electric power industry, and stakeholders. Those responsible for making decisions about increasingly costly investments to prevent such interruptions and to facilitate rapid recovery when they do occur need relevant information on which to base those decisions. Although a number of studies have examined the physical and engineering impacts of extreme weather and other precipitating events on the bulk power system, decision makers evaluating investments in preventive strategies need information on the costs of past power interruptions and the benefits of preventing them in the future. This paper contributes to addressing this need by offering six case studies that detail the economics, at the level of the utility service territory, of power interruptions caused by extreme weather and lasting from a few days to several weeks. These intermediate-duration interruptions have been, and will continue to be, the most common type of major electric power disruption. They are longer than the short-term disruptions addressed in utility reliability planning, but not as long or widespread geographically as the national-scale interruptions with durations of many weeks, months, or longer that have been examined in some recent studies.
Presentation for National Laboratory Information Technology 2019 Conference. Various DOE and NNSA labs and sites will be in attendance.
The project examined next-generation power distribution systems with high levels of power- electronics-interfaced distributed energy resources (DERs) that include: renewable energy systems (RESs), energy-storage devices, electric vehicles, fuel cells, small-scale diesel generators, and controllable loads. The project developed a comprehensive distribution- network management framework that unifies real-time voltage and frequency control with network-wide energy management under an integrated framework. The aim of the project was to: i) systematically optimize network-wide operation and congruently regulate voltages and frequency in the face of high volatility induced by rapidly varying RES and uncontrolled loads; ii) facilitate high renewable integration beyond 50% on an energy basis; iii) meet power-quality requirements and operational constraints; and, iv) respect response, ramp- time, and hold-time requirements for synthetic frequency and regulating reserves via fast- and longer-term dynamic energy management.
The LHC is undoubtfully the most important instrument the HEP community has on its disposal and is widely considered an amazing technological achievement. At the core of this instrument lay accelerator magnets based on NbTi technology – a technology well developed and widely used in the commercial sector too. Yet, a decade after the accelerator started it still did not reach its design collision energy of 14 TeV and it operated for years well below it. The reason for this is simple – magnet training (even though only a subset of the magnets is mostly affected).
Focal Area(s) Areas: We discuss how the integration of AI into Earth Science models can impact streamflow predictions at both the science and data levels. Doing so, we address cross-cutting needs related to the goal of making data FAIR (Findable, Accessible, Interoperable, and Re-usable [1]) for seamless use with Artificial Intelligence/Machine Learning (AI/ML) in Earth System Science at DOE. A novel idea is that AI/ML itself can help with the FAIR data goal and address issues in targeted areas e.g. missing data, data quality and reduction. In addition, the interpretability of results obtained with new AI methods is poised to impact broader scientific challenges in hydrology..
The U.S. Department of Energy’s (DOE) Office of Electricity and Office of Energy Efficiency & Renewable Energy have funded DOE National Laboratories to perform modeling, analysis, and high-level design of resilience-enhancement options for the power grid of the Commonwealth of Puerto Rico. The Pacific Northwest National Laboratory (PNNL) is one of the national laboratories contributing to the DOE effort. Under this funding, PNNL completed Phase I of their analysis in 2018, which identified high-priority transmission enhancements derived from detailed dynamic cascading analysis of severe contingencies, including a hurricane scenario example. This report describes additional analysis completed under Phase II, which was performed over 2019. The PNNL team applied decades of experience making complex power systems more resilient, reliable, secure, flexible, affordable and sustainable, with partners in government and industry. In this report, PNNL presents the Phase II analysis, in which a risk-based dynamic contingency analysis approach to evaluate impact of several hurricane scenarios was developed. This approach was used to identify high-priority enhancements and test resilience mitigation actions, including the evaluation of high-solar scenarios developed as a result of the 2019 Puerto Rico Integrated Resource Plan (IRP).
The goal of this project was to work with rural electric cooperatives to facilitate the diffusion of solar energy adoption in households located in the rural and semi-urban areas of Virginia by identifying social and behavioral factors that might be unique to rural regions; and develop a model to calculate the solar adoption propensity score for household based on their demographics, social and behavioral characteristics which would provide an objective metric to cooperatives that can be further used to do targeted marketing of rooftop solar panels. This was achieved through the following tasks: (1) Conducted a survey of the members of Virginia electric cooperatives to identify demographic, social, financial and behavioral attributes of individuals who are likely to adopt rooftop solar panels. (2) Developed a highly detailed, data-driven, agent-based model of the population of Virginia, focusing on the rural regions. (3) Developed diffusion models that use social, behavioral, and demographic factors, and peer effects to study their impact on solar adoption in rural areas. (4) Built a prototype tool based on the diffusion model to help study market segmentation in rural areas and made it available to National Rural Electric Cooperative Association (NRECA). (5) Results and recommendations derived from the model were provided to NRECA to be shared with participating cooperatives. (6) Results were published in peer reviewed journals, conference proceedings and book chapters, and ideas disseminated through presentations and newsletters. There were several important methodological contributions made under this project which are detailed in the published papers, including: (1) Built a decision-adjusted model for predicting adoptors with imbalanced training data; (2) designed seeding strategies to maximize adoption given a fixed budget; (3) built a methodology to compare different agent based models; (4) created models to identify important factors that influence decision to adopt solar panels; and (5) built a methodology for building household profiles of solar generation to study the duck curve phenomenon. The team included members from the University of Virginia (lead), National Rural Electric Cooperative Association (NRECA), Arizona State University, Virginia Tech and Sandia National Laboratory. Note that no individual entity or stakeholder has incentive to promote solar in rural regions. Most of the research and work focuses around urban regions where the potential for growth in solar adoption is higher due to higher population density. This puts rural areas at a disadvantage. By improving the diffusion of solar adoption in rural parts of the country, we can not only provide clean energy to rural areas but also promote job growth and improves energy independence.
Stakeholders in industry, agriculture, and city governments are struggling to understand how to manage climate change risks. Climate scientists, meanwhile, want to know what specific information their fellow citizens need from them to take action.
Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations
The Y-12 SIRP Quadrant 1, Quadrant 2, and Vehicle Barrier project involves the following summary elements. The perimeter intrusion detection and assessment system (PIDAS) is an existing system at the Y-12 National Security Complex, which is a government-owned facility located in Oak Ridge, Tennessee, and managed by Consolidated Nuclear Security, LLC (CNS) for the Department of Energy (DOE). National Technology and Engineering Solutions of Sandia, LLC (NTESS) is the engineering design agent and construction manager (CM) for the Y-12 SIRP effort. The Quadrants 1 and 2 portion of the project involves the replacement of the PIDAS, and the vehicle barrier portion of the project involves the installation of a continuous passive vehicle barrier alongside the inner PIDAS fence.
The main goal of this project was to create a state-of-the-art predictive capability that screens and identifies wellbores that are at the highest risk of catastrophic failure. This capability is critical to a host of subsurface applications, including gas storage, hydrocarbon extraction and storage, geothermal energy development, and waste disposal, which depend on seal integrity to meet U.S. energy demands in a safe and secure manner. In addition to the screening tool, this project also developed several other supporting capabilities to help understand fundamental processes involved in wellbore failure. This included novel experimental methods to characterize permeability and porosity evolution during compressive failure of cement, as well as methods and capabilities for understanding two-phase flow in damaged wellbore systems, and novel fracture-resistant cements made from recycled fibers.