Search NASA⌕ Search

SEARCH · Search NASA

Results for “Injection testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Performance evaluation of the Russian SPT-100 thruster at NASA LeRC

Performance measurements of a Russian flight-model SPT-100 thruster were obtained as part of a comprehensive program to evaluate engineering issues pertinent to integration with Western spacecraft. Power processing was provided by a US Government developed laboratory power conditioner. When received the thruster had been subjected to only a few hours of acceptance testing by the manufacturer. Accumulated operating time during this study totalled 148 h and included operation of both cathodes. Cathode flow fraction was controlled both manually and using the flow splitter contained within the supplied xenon flow controller. Data were obtained at current levels ranging from 3 A to 5 A and thruster voltages ranging from 200 V to 300 V. Testing centered on the design power of 1.35 kW with a discharge current of 4.5 A. The effects of facility pressure on thruster operation were examined by varying the pressure via injection of xenon into the vacuum chamber. The facility pressure had a significant effect on thruster performance and stability at the conditions tested. Periods of current instabilities were noted throughout the testing period and became more frequent as testing progressed. Performance during periods of stability agreed with previous data obtained in Russian laboratories.

Sankovic, John M.↗

Site Characterization of the Highest-Priority Geologic Formations for CO2 Storage in Wyoming

The project Site Characterization of the Highest-Priority Geologic Formations for CO2 Storage in Wyoming is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The Wyoming Carbon Underground Storage Project (WY-CUSP) consisted of CO2 storage site characterization and evaluation, focusing on Wyoming’s most promising CO2 storage reservoirs (the Pennsylvanian Weber/Tensleep Sandstone and Mississippian Madison Limestone) and premier CO2 storage site (Rock Springs Uplift). Results from the WY-CUSP project suggest the two reservoirs could store up to 17,000 million tons of CO2. The WY-CUSP team drilled a stratigraphic test well and acquired a 3-D seismic survey covering 25 square miles of the Rock Springs Uplift site. The team retrieved 916 feet of core from the 12,810-foot-deep well, along with a complete log suite, borehole images, fluid samples, and other data. Project partners (1) provided continuous visual documentation of the core, including grain size, mineralogy, facies distribution, and porosity; (2) performed continuous permeability and velocity scans of selected reservoir intervals; and (3) chemically analyzed the fluid samples. WY-CUSP scientists integrated seismic attributes with observations from log suites, a VSP survey, core, fluid samples, and laboratory analyses, including continuous permeability scans. From these integrations, researchers constructed 3-D spatial distribution volumes of reservoir and seal properties that represent geological heterogeneity at the targeted CO2 storage site. The WY-CUSP team used this data to perform new CO2 plume migration simulations. Baker Hughes, Inc., completed a series of small-scale, in-situ water injectivity measurements. A database was formed when observations, analyses, and experiments from the stratigraphic test well were integrated. Correlation of these data allowed petrophysical parameters to be extrapolated from the test well out into the storage domain (5x5 mile 3-D seismic survey volume). This resulted in an improved, realistic understanding of performance assessments for potential CO2 storage scenarios. The WY-CUSP team worked on (1) improving CO2 storage resource estimates, (2) establishing long-term integrity and permanence of confining layers, (3) designing a profitable strategy for pressure management, and (4) evaluating the utilization of stored CO2 at the Rock Spring Uplift. Finally, Baker Hughes developed a microseismic baseline for the test site using in-bore geophones to complete field operations.

3-D seismic↗

PRELIMINARY TEST RESULTS OF A PROTOTYPE FAST KICKER FOR APS MBA UPGRADE

The APS multi-bend achromatic (MBA) upgrade storage ring plans to support two bunch fill patterns: a 48-bunch and a 324-bunch. A “swap out” injection scheme is required. In order to provide the required kick to injected beam, to minimize the beam loss and residual oscillation of injected beam, and to minimize the perturbation to stored beam during injection, the rise, fall, and flat-top parts of the kicker pulse must be within a 16.9-ns interval. Stripline-type kickers are chosen for both injection and extraction. We developed a prototype kicker that supports a ±15kV differential pulse voltage. We performed high voltage discharge, TDR measurement, high voltage pulse test and beam test of the kicker. We report the final design of the fast kicker and the test results.

APS MBA UPGRADE↗

Design, Fabrication, and Testing of an Auxiliary Cooling System for Jet Engines

This report summarizes the technical effort of the Active Cooling for Enhanced Performance (ACEP) program sponsored by NASA. It covers the design, fabrication, and integrated systems testing of a jet engine auxiliary cooling system, or turbocooler, that significantly extends the use of conventional jet fuel as a heat sink. The turbocooler is designed to provide subcooled cooling air to the engine exhaust nozzle system or engine hot section. The turbocooler consists of three primary components: (1) a high-temperature air cycle machine driven by engine compressor discharge air, (2) a fuel/ air heat exchanger that transfers energy from the hot air to the fuel and uses a coating to mitigate fuel deposits, and (3) a high-temperature fuel injection system. The details of the turbocooler component designs and results of the integrated systems testing are documented. Industry Version-Data and information deemed subject to Limited Rights restrictions are omitted from this document.

Leamy, Kevin↗

Low-Temperature Combustion of High Octane Fuels in a Gasoline Compression Ignition Engine

Gasoline Compression Ignition (GCI) has been shown as one of the advanced combustion concepts that could potentially provide a pathway to achieve cleaner and more efficient combustion engines. Fuel and air in GCI are not fully premixed as compared to homogeneous charge compression ignition (HCCI) which is a completely kinetic-controlled combustion system. Therefore, the combustion phasing can be controlled by the time of injection, usually post injection in a multiple-injection scheme, to mitigate combustion noise. Gasoline fuels ignite more difficult than Diesel. The autoignition quality of gasoline can be indicated by research octane number (RON). Fuels with high octane tend to have more resistance to auto-ignition, hence more time for fuel-air mixing. In this study, three fuels, namely, Aromatic, Alkylate, and E30, with similar RON value of 98 but different hydrocarbon compositions were tested in a multi-cylinder engine under GCI combustion mode. Considerations of EGR, start of injection (SOI), and boost were investigated to study the sensitivity of dilution, local stratification, and reactivity of the charge, respectively, for each fuel. Combustion phasing was kept constant during the experiments to the changes in ignition and combustion process before and after 50% of the fuel mass is burned. Emission characteristics at different levels of EGR and lambda were revealed for all fuels with E30 having the lowest filter smoke number (FSN) and was also most sensitive to the change in dilution. Reasonably low combustion noise (< 90 dB) and stable combustion (COVIMEP < 3%) were maintained during the experiments. The second part of this paper contains visualization of the combustion process obtained from endoscope imaging for each fuel at selected conditions. Soot radiation signal from GCI combustion were strong during late injection, and also more intense at low EGR conditions. Furthermore, soot/temperature profiles indicated only the high-temperature combustion period, while cylinder pressure-based heat release rate (HRR) showed a two-stage combustion phenomenon.

33 ADVANCED PROPULSION SYSTEMS↗

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series are: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and to develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

Ben Swartout↗

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series were: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

TVAC↗

Experimental and numerical study of swept ramp injection into a supersonic flowfield

Time-averaged measurements of pressure, temperature, velocity, and injectant mole fraction are presented using the planar laser-induced iodine fluorescence technique in the complex three-dimensional compressible flowfield around a swept ramp fuel injector. Within the range of thermodynamic conditions present in the test case studied, the technique's accuracy is estimated to be 4% for pressure, temperature, and velocity and 3% for injectant mole fraction. Comparisons with numerical simulations using the SPARK three-dimensional Navier-Stokes computer code with an algebraic turbulence model are made at the centerplane of the flowfield as well as on three crossflow planes downstream of the injector. Calculations and measurements are in good agreement throughout the flowfield, with deviations on the order of 5%; however, in specific regions, such as in the base of the ramp, deviations are larger. A weak asymmetry in the incoming flowfield appears to be amplified by boundary-layer separation occurring when the ramp-generated shock reflects off the tunnel walls. Ramp-generated vortices are weaker in the calculated results due to the effects of numerical viscosity in the vortex cores. This leads to less turning and mixing of the jet plume than observed in the experiments. The rate of decay of the maximum injectant mole fraction with streamwise distance is greater for the present ramp injection scheme than for previously measured transverse injection schemes. In this recirculation region at the base of the injector, laminar calculations show better agreement with the measurements than turbulent calculations.

Donohue, James M.↗

Regulation of the central safety factor and normalized beta under low NBI torque in DIII-D

An algorithm has been designed to simultaneously control the central safety factor (q 0 ) and normalized beta (β N ) while ensuring near-zero torque from the neutral beam injection in DIII-D. Feedback control of q 0 and β N in tokamaks can be beneficial due to the close relationship that these variables have with plasma performance and magneto-hydrodynamic stability. In addition, low neutral-beam-torque conditions are of special interest in present devices because future burning-plasma tokamaks such as ITER will most likely operate at very low plasma rotation. The control synthesis of the algorithm presented in this work is based on a linearized, one-dimensional (1D) model of the current-profile dynamics coupled with a zero-dimensional (0D) plasma-energy balance. The actuators considered are neutral beam injection and electron-cyclotron heating and current drive, and discrete logic determines the neutral-beam injection powers that deliver near-zero torque. Here, the algorithm has been tested in nonlinear, 1D simulations using COTSIM (Control-Oriented Transport SIMulator) and in DIII-D experiments, demonstrating satisfactory performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative microinjection using fluorescence calibration of streaming microdroplets on a superhydrophobic surface

Highlights: • Superhydrophobic surfaces prevent droplet surface adhesion and deformation. • Wide tipped micropipettes create a stream of microdroplets. • Streaming creates a large number of varying sized droplets quickly and easily. • Fluorescence-volume calibration curves can be created with tracer microdroplets. • Calibrated fluorescent tracers allow for quantifiable, cellular microinjection. A simple and reproducible procedure was developed to measure the volume of liquid microinjected into cells. A calibration curve of droplet fluorescence intensity versus volume was constructed by injecting a fluorescent dextran solution through a 125–150 µm diameter micropipette into an oil-filled culture dish to create a spray of varied-sized droplets. The droplets retained a spherical shape because they were in an oil medium and they settled onto a glass surface coated with a superhydrophobic surface. Fluorescent micrographs of the droplets were obtained and analyzed with Image-J software to quantify the fluorescence intensity and radius of each spherical droplet to produce the calibration curve. Subsequently, Dut-145 human prostate carcinoma cells were microinjected with the same fluorescent dextran solution and fluorescent micrographs of the cells were obtained using the identical exposure conditions used to photograph the droplets. The measured fluorescence intensity of the microinjected cells was entered into the formula for the regression line that was fit to the calibration curve allowing determination of the volume of solution injected into each cell. Thus, a mixture consisting of known concentrations of a test material of test material (macromolecules, drugs, etc.) and a fluorescent dextran, volumetric, tracer can be used to quantify the relationship between the amount of a microinjected material and subsequent effects on cells.

60 APPLIED LIFE SCIENCES↗

Measurements of Decay and Snapback in Nb₃Sn Accelerator Magnets at Fermilab

In recent years, Fermilab has been executing an inten-sive R&D program on Nb₃Sn accelerator magnets. This program has included dipole and quadrupole models and demonstrators for various programs and projects, including the HL-LHC accelerator upgrade project. A systematic study of the field decay and snapback during the injection portion of a simulated accelerator cycle was executed at the Fermilab Magnet Test Facility. This paper summarizes the recent measurements of the MQXFS1 short quadrupole model and discusses the results of some previously measured Nb₃Sn magnets at CERN

43 PARTICLE ACCELERATORS↗

Exploration of a Reacting Jet-in-Crossflow in a High-Pressure Axial Stage Combustor

The present work investigates a reacting methane jet in a vitiated cross flow at five atmospheres. The experiments are run at temperatures and velocities relevant to real world gas turbines. High speed chemiluminescence is utilized to obtain flame behavior and visualize flame trajectories. Experimental results are compared with a corresponding RANS CFD model. The characteristics of a diffusion methane jet injected into a vitiated crossflow are explored at various momentum flux ratios and test section inlet boundary conditions. Temperature and velocity measurements are made at the inlet of the test section to ensure uniform boundary conditions for the axial stage. The effect of different momentum flux ratios on flame stabilization mechanisms and jet trajectories are presented. Momentum flux ratios are varied from 0.5-107; at lower momentum flux ratios the diffusion flame is less stable and burns downstream in the shear layer between the jet and crossflow. At higher momentum flux ratios, the diffusion flame burns more upstream and exhibits improved stability compared to the lower momentum flux ratio cases.

03 NATURAL GAS↗

Fifteen cm mercury ion thruster research, 1976

Improvements in 15 cm diameter, SERT II, mercury ion thruster performance effected by the use of SHAG optics at 33 V discharge voltage were discussed. At a 200 eV/ion discharge power, 90 percent propellant utilization and 660 mA beam current condition a doubly-to-singly charged ion current ratio of about 4 percent was measured. Performance of the 15 cm multipole mercury thruster (optimized for length and the point of electron injection) was compared to that of divergent (SERT II) and cusped field designs and found to be comparable. The need for a magnetic baffle in the multipole thruster was identified and the preferred point of electron injection was at the upstream end of the discharge chamber. Results of preliminary tests on the effects of discharge voltage and total accelerating voltage on perveance and beam divergence characteristics of two grid ion optics were examined. Experimental data showing the effect of target temperature on sputtering rates in a mercury discharge environment were presented and a deficiency in the tests procedure was identified.

Wilbur, P. J.↗

Equilibrium geochemical modeling of a seasonal thermal energy storage aquifer field test

A geochemical mathematical modeling study designed to investigate the well plugging problems encountered at the Auburn University experimental field tests is summarized. The results, primarily of qualitative interest, include: (1) loss of injectivity was probably due to a combination of native particulate plugging and clay swelling and dispersion; (2) fluid-fluid incompatibilities, hydrothermal reactions, and oxidation reactions were of insignificant magnitude or too slow to have contributed markedly to the plugging; and (3) the potential for and contributions from temperature-induced dissolved gas solubility reductions, capillary boundary layer viscosity increases, and microstructural deformation cannot be deconvolved from the available data.

Stottlemyre, J. S.↗

Estimation of fan pressure ratio requirements and operating performance for the National Transonic Facility

The National Transonic Facility (NTF), a fan-driven, transonic, pressurized, cryogenic wind tunnel, will operate over the Mach number range of 0.10 to 1.20 with stagnation pressures varying from 1.00 to about 8.8 atm and stagnation temperatures varying from 77 to 340 K. The NTF is cooled to cryogenic temperatures by the injection of liquid nitrogen into the tunnel stream with gaseous nitrogen as the test gas. The NTF can also operate at ambient temperatures using a conventional chilled water heat exchanger with air on nitrogen as the test gas. The methods used in estimating the fan pressure ratio requirements are described. The estimated NTF operating envelopes at Mach numbers from 0.10 to 1.20 are presented.

Gloss, B. B.↗

Provisions for nonintrusive flow-evaluation tools in the National Transonic Facility

The national transonic facility fan driven, closed circuit, continuous flow, pressurized wind tunnel is examined. The test section is 2.500 m x 2.500 m and 7.620 m long with a slotted wall configuration. There are six slots each in the top and bottom walls and two slots per sidewall. To maintain good flow quality and aerodynamic efficiency over the wide range of test capabilities the test section geometry is variable. The position of the test section and bottom walls, the reentry flaps at the rear of the test section slots, and the step height for reentering slot flow are remotely controlled. The test gas may be dry air or nitrogen, which for the elevated temperature (340 K) mode of operation the test medium is normally air, and heat removal is by a water cooled heat exchanger (cooling coil) located at the upstream end of the settling chamber. For the cryogenic mode of operation, heat removal is by evaporation of liquid nitrogen, which is sprayed into the circuit upstream of the fan. By utilizing liquid nitrogen as a coolant, the tunnel test temperature range is variable from 340 to 78 K. When nitrogen is injected into the circuit, venting must occur to maintain a constant pressure. Thermal insulation is installed internal to the pressure shell to minimize energy consumption.

Fuller, D. E.↗

Ignition of steel alloys by impact of low-velocity iron/inert particles in gaseous oxygen

The ignition of carbon steel and 316 and 304 stainless steels caused by the impact of low-velocity particles (a standard mixture consisting of 2 g of iron and 3 g of inert materials) in gaseous oxygen was investigated using NASA/White Sands Test Facility for the ignition test, and a subsonic particle impact chamber to accelerate the particles that were injected into flowing oxygen upstream of the target specimen. It was found that the oxygen velocities required to ignite the three alloys were the same as that required to ignite the particle mixture. Ignition occurred at oxygen velocities greater than 45 m/sec at 20 to 24 MPa and was found to be independent of pressure between 2 and 30 MPa. Comparison of the present results and the past results from Wegener (1964) with the Compressed Gas Association (CGA) oxygen velocity limits for safe operations indicates that the CGA limits may be excessively conservative at high pressures and too liberal at low pressures.

Benz, Frank J.↗

CFD Mixing Analysis of Jets Injected from Straight and Slanted Slots into Confined Crossflow in Rectangular Ducts

A CFD study was performed to analyze the mixing potential of opposed rows of staggered jets injected into confined crossflow in a rectangular duct. Three jet configurations were numerically tested: (1) straight (0 deg) slots; (2) perpendicular slanted (45 deg) slots angled in opposite directions on top and bottom walls; and (3) parallel slanted (45 deg) slots angled in the same direction on top and bottom walls. All three configurations were tested at slot spacing-to-duct height ratios (S/H) of 0.5, 0.75, and 1.0; a jet-to-mainstream momentum flux ratio (J) of 100; and a jet-to-mainstream mass flow ratio of 0.383. Each configuration had its best mixing performance at S/H of 0.75. Asymmetric flow patterns were expected and predicted for all slanted slot configurations. The parallel slanted slot configuration was the best overall configuration at x/H of 1.0 for S/H of 0.75.

Bain, D. B.↗