Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Prototype ultrasonic instrument for quantitative testing

A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

Lynnworth, L. C.↗

Large space telescope, phase A. Volume 4: Scientific instrument package

The design and characteristics of the scientific instrument package for the Large Space Telescope are discussed. The subjects include: (1) general scientific objectives, (2) package system analysis, (3) scientific instrumentation, (4) imaging photoelectric sensors, (5) environmental considerations, and (6) reliability and maintainability.

Source record↗

Problems affecting the fidelity of pressure measuring instruments for planetary probes

Determination is made of the nature and magnitude of surface-related effects that cause errors in pressure measuring instruments, with special reference being made to instruments intended for use in planetary probes. The interaction of gases with clean surfaces of metals likely to be used as gage construction materials was studied. Special emphasis was placed on the adsorption, chemical reaction, and electron-induced desorption processes. The results indicated that all metals tested were subject to surface processes which would degrade gage fidelity. It was also found, however, that the formation of inert adsorbed layers on these metal surfaces, such as carbon on platinum, greatly reduced or eliminated these effects. This process, combined with a system design which avoids contact between reactive gases and hot filaments, appears to offer the most promising solution to the gage fidelity problem.

Hudson, J. B.↗

Science instrumentation package, LST

The projected design of an optical instrument package for the large space telescope includes: a diffraction limited camera; low- and high-dispersion spectrographs; astrometric machines; photometers; polarimeters; F/12 camera; Fourier interferometer; infrared instrumentation; and a very high dispersion spectrographs.

Levin, G.↗

Investigation of turbulence in the solar photosphere with allowance for influence of the instrumental contour

The solar photosphere turbulence was investigated, taking into account the effect of the instrumental profile. Ten Unno's pairs for the center of the solar disk were observed. The main results are as follows: (1) without taking into account the factors distorting a line, the turbulent velocity in solar photosphere would decrease with height. The values of xi sub t are similar to those of Unno; (2) taking into account the instrument profile, the value of turbulent velocity becomes less, but its dependence on height is the same. The maximum relative error of xi sub t is approximately equal to 13.6%.

Troyan, V. I.↗

Instrumentation for air quality measurements.

Comparison of the new generation of air quality monitoring instruments with some more traditional methods. The first generation of air quality measurement instruments, based on the use of oxidant coulometric cells, nitrogen oxide colorimetry, carbon monoxide infrared analyzers, and other types of detectors, is compared with new techniques now coming into wide use in the air monitoring field and involving the use of chemiluminescent reactions, optical absorption detectors, a refinement of the carbon monoxide infrared analyzer, electrochemical cells based on solid electrolytes, and laser detectors.

Loewenstein, M.↗

The Harvard experiment on OSO-6 - Instrumentation, calibration, operation, and description of observations.

The Harvard experiment carried by OSO-6 was an extreme-ultraviolet (EUV) spectrometer-spectroheliometer with a wavelength range of 285 to 1385 A, a spatial and spectral bandwidth of 35 x 35(arc sec) squared and 3 A, respectively. The instrument acquired data that have been deposited with the National Space Science Data Center and World Data Center A at the Goddard Space Flight Center in Greenbelt, Maryland, and are now available in their entirety to the scientific community. Aspects of the experiment that are relevant to potential users of the data are described - namely, instrument configuration and parameters, laboratory and inflight calibrations, as well as operational capabilities and procedures. The observations obtained are reported, and the nature, number, and dates of observation, where relevant, are listed.

Huber, M. C. E.↗

Instrumentation for the Atmospheric Explorer photoelectron spectrometer

The photoelectron spectrometer (PES) is part of the complements of scientific instruments aboard three NASA Atmosphere Explorer (AE) satellites. The PES measures the energy spectrum, angular distribution, and intensity of electrons in the earth's thermosphere. Measurements of energies between 2 and 500 eV are made at altitudes as low as 130 km. The design, characteristics, and performance of the instrument are described.

Peletier, D. P.↗

Flight investigation of manual and automatic VTOL decelerating instrument approaches and landings

A flight investigation was undertaken to study the problems associated with manual and automatic control of steep, decelerating instrument approaches and landings under simulated instrument conditions. The study was conducted with a research helicopter equipped with a three-cue flight-director indicator. The scope of the investigation included variations in the flight-director control laws, glide-path angle, deceleration profile, and control response characteristics. Investigation of the automatic-control problem resulted in the first automated approach and landing to a predetermined spot ever accomplished with a helicopter. Although well-controlled approaches and landings could be performed manually with the flight-director concept, pilot comments indicated the need for a better display which would more effectively integrate command and situation information.

Kelly, J. R.↗

Vibration and noise measuring instruments built in the RSR

The demands placed upon vibration and noise measuring instruments are discussed. The instruments that are now being manufactured in the RSR are described, as well as those that are being made ready for manufacture, namely: the VP-3 portable vibrometer, the N2103 precision electronic vibrometer, the N2103 B sonometric preamplifier, as well as vibration transducers of the electrodynamic and piezoelectric types.

Georgescu, I.↗

MSFC Skylab instrumentation and communication system mission evaluation

An evaluation of the in-orbit performance of the instrumentation and communications systems installed on Skylab is presented. Performance is compared with functional requirements and the fidelity of communications. In-orbit performance includes processing engineering, scientific, experiment, and biomedical data, implementing ground-generated commands, audio and video communication, generating rendezvous ranging information, and radio frequency transmission and reception. A history of the system evolution based on the functional requirements and a physical description of the launch configuration is included. The report affirms that the instrumentation and communication system satisfied all imposed requirements.

Adair, B. M.↗

Vibrational sensitivity of a measuring instrument and methods of increasing the accuracy of its determinations

The properties and peculiarities of two groups of measuring systems reacting to vibrations are discussed. Specifically, results of the action of a three dimensional, cophasal, monoharmonic vibration on the linear system of a measuring instrument was analyzed. Data are also given on the connection between vibration sensitivity and vibration resistance for instruments, methods for estimating vibration resistance, and formulas for expressing test results of vibration resistance. Experimental data are also given for decreasing errors in nonlinear systems during vibrations.

Mironov, Y. S.↗

Study of an instrument for sensing errors in a telescope wavefront

Focal plane sensors for determining the error in a telescope wavefront were investigated. The construction of three candidate test instruments and their evaluation in terms of small wavefront error aberration measurements are described. A laboratory wavefront simulator was designed and fabricated to evaluate the test instruments. The laboratory wavefront error simulator was used to evaluate three tests; a Hartmann test, a polarization shearing interferometer test, and an interferometric Zernike test.

Golden, L. J.↗

Measurement of instrument noise spectra at frequencies below 1 hertz

The use of peak-to-peak values in describing output noise of a magnetometer or low frequency amplifier is of questionable value for certain applications. A more precise statement of instrument noise is made with a plot of the noise power spectral density vs frequency. The spectral density plot provides a rich source of information which can be used in the selection and testing of such instrumentation.

Snare, R. C.↗

Optical instrumentation engineering in science, technology and society; Proceedings of the Sixteenth Annual Technical Meeting, San Mateo, Calif., October 16-18, 1972

Visual tracking performance in instrumentation is discussed together with photographic pyrometry in an aeroballistic range, optical characteristics of spherical vapor bubbles in liquids, and the automatic detection and control of surface roughness by coherent diffraction patterns. Other subjects explored are related to instruments, sensors, systems, holography, and pattern recognition. Questions of data handling are also investigated, taking into account minicomputer image storage for holographic interferometry analysis, the design of a video amplifier for a 90 MHz bandwidth, and autostereoscopic screens. Individual items are announced in this issue.

Katz, Y. H.↗

Research instrumentation requirements for flight/wind-tunnel tests of the YF-12 propulsion system and related flight experience

Description of the requirements for a comprehensive flight and wind-tunnel propulsion research program to examine the predictability of inlet performance, evaluate the effects of high-frequency pressure phenomena on inlets, and investigate improved control concepts in order to cope with airframe interactions. This program is unique in that it requires precise similarity of the geometry of the flight vehicle and tunnel modes; the test conditions, including local flow at the inlet; and instrumentation. Although few wind-tunnel instrumentation problems exist, many problems emerge during flight tests because of the thermal environment. Mach 3 flight temperatures create unique problems with transducers, connectors, and wires. All must be capable of withstanding continuous 1000 F temperatures, as well as the mechanical stresses imposed by vibration and thermal cycling.

Schweikhard, W. G.↗

Applications of fluidics to light aircraft instrumentation and control

Review of a program for the development of advanced fluidic components and the application of these components to general aviation instrumentation and control. The major project in this category has been the development of a simple, reliable, two-axis autopilot for light aircraft, using a fluidic inertial rate sensor for stability and roll attitude control, and a simple magnetometer for azimuth reference. This autopilot has been succesfully flight-tested. Fluidic hardware developed for this autopilot is described, and projected improvements and extensions are discussed. Application of fluidic components to such flight instruments as turn coordinators, artificial horizons, and true airspeed indicators is explored.

Garner, H. D.↗

Cosmic gamma-ray burst detected with an instrument on board the OGO-5 satellite

Gamma-ray bursts of cosmic origin have recently been detected by instruments on the Vela satellites. We now confirm the detection of the June 30, 1971 event with an instrument on board the OGO-5 satellite. The intensity of this burst is calculated to be approximately 100-200 photons per sq cm/sec for photons of energy greater than 150 keV with an upper limit of 50 photons per sq cm/sec for the intensity above 5 MeV. An upper limit of one-third of the intensity of the June 30, 1971 event is set for 10 other events studied.

Lheureux, J.↗