Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Admittance Test and Conceptual Study of a CW Positron Source for CEBAF

A conceptual study of a Continuous Wave (CW) positron production is presented in this paper. The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLAB) operates with a CW electron beam with a well-defined emittance, time structure and energy spread. Positrons created via bremsstrahlung photons in a high-Z target emerge with a large emittance compared to incoming electron beam. An admittance study has been performed at CEBAF to estimate the maximum beam phase space area that can be transported in the LINAC and in the Arcs. A positron source is described utilizing the CEBAF injector electron beam, and directly injecting the positrons into the CEBAF LINAC.

43 PARTICLE ACCELERATORS↗

ANN-based ground motion model for Turkey using stochastic simulation of earthquakes

SUMMARY Turkey is characterized by a high level of seismic activity attributed to its complex tectonic structure. The country has a dense network to record earthquake ground motions; however, to study previous earthquakes and to account for potential future ones, ground motion simulations are required. Ground motion simulation techniques offer an alternative means of generating region-specific time-series data for locations with limited seismic networks or regions with seismic data gaps, facilitating the study of potential catastrophic earthquakes. In this research, a local ground motion model (GMM) for Turkey is developed using region-specific simulated records, thus constructing a homogeneous data set. The simulations employ the stochastic finite-fault approach and utilize validated input-model parameters in distinct regions, namely Afyon, Erzincan, Duzce, Istanbul and Van. To overcome the limitations of linear regression-based models, artificial neural network is used to establish the form of equations and coefficients. The predictive input parameters encompass fault mechanism (FM), focal depth (FD), moment magnitude (Mw), Joyner and Boore distance (RJB) and average shear wave velocity in the top 30 m (Vs30). The data set comprises 7359 records with Mw ranging between 5.0 and 7.5 and RJB ranging from 0 to 272 km. The results are presented in terms of spectral ordinates within the period range of 0.03–2.0 s, as well as peak ground acceleration and peak ground velocity. The quantification of the GMM uncertainty is achieved through the analysis of residuals, enabling insights into inter- and intra-event uncertainties. The simulation results and the effectiveness of the model are verified by comparing the predicted values of ground motion parameters with the observed values recorded during previous events in the region. The results demonstrate the efficacy of the proposed model in simulating physical phenomena.

Karimzadeh, Shaghayegh (ORCID:0000000337531676)↗

Ontogeny of vestibular compound action potentials in the domestic chicken

Compound action potentials of the vestibular nerve were measured from the surface of the scalp in 148 chickens (Gallus domesticus). Ages ranged from incubation day 18 (E18) to 22 days posthatch (P22). Responses were elicited using linear acceleration cranial pulses. Response thresholds decreased at an average rate of -0.45 dB/day. The decrease was best fit by an exponential model with half-maturity time constant of 5.1 days and asymptote of approximately -25.9 dB re:1.0 g/ms. Mean threshold approached within 3 dB of the asymptote by ages P6-P9. Similarly, response latencies decreased exponentially to within 3% of mature values at ages beyond P9. The half-maturity time constant for peripheral response peak latencies P1, N1, and P2 was comparable to thresholds and ranged from approximately 4.6 to 6.2 days, whereas central peaks (N2, P3, and N3) ranged from 2.9 to 3.4 days. Latency-intensity slopes for P1, N1, and P2 tended to decrease with age, reaching mature values within approximately 100 hours of hatching. Amplitudes increased as a function of age with average growth rates for response peaks ranging from 0.04 to 0.09 microV/day. There was no obvious asymptote to the growth of amplitudes over the ages studied. Amplitude-intensity slopes also increased modestly with age. The results show that gravity receptors are responsive to transient cranial stimuli as early as E19 in the chicken embryo. The functional response of gravity receptors continues to develop for many days after all major morphological structures are in place. Distinct maturational processes can be identified in central and peripheral neural relays. Functional improvements during maturation may result from refinements in the receptor epithelia, improvements in central and peripheral synaptic transmission, increased neural myelination, as well as changes in the mechanical coupling between the cranium and receptor organ.

NASA Discipline Developmental Biology↗

Design and study of a high-current 5-cell superconducting rf cavity.

The Advanced Photon Source (APS) at Argonne National Laboratory is considering the development of a superconducting linac-based fourth-generation hard X-ray source to meet future scientific needs of the hard X-ray user community. This work specifically focuses on the design of an optimized 5-cell superconducting radio-frequency structure well suited for a high-energy, high-beam-current energy recovery linac. The cavity design parameters are based on the APS storage ring nominal 7 GeV and 100 mA beam operation. A high-current 5-cell cw superconducting cavity operating at 1.4 GHz has been designed. In order to achieve a high current, the accelerating cavity shape has been optimized and large end-cell beam pipes have been adopted. The beam break-up threshold of the cavity has been estimated using the code TDBBU, which predicts a high threshold beam current for a 7 GeV energy recovery linac model. A copper prototype cavity has been fabricated that uses half-cell modules, initially assembled by clamping the cells together.

43 PARTICLE ACCELERATORS↗

Recent Studies of Nucleon Electromagnetic Form Factors

The electromagnetic form factors of nucleons are fundamental quantities in nucleon structure. As such, they have been studied extensively both theoretically and experimentally. Significant progress has been made with new measurements at Jlab, MAMI and MIT-Bates, with emphases on expanding the momentum-transfer range and on higher precision. In this paper, we describe the status of this field and present new results from measurements at both low and high momentum transfers. We also compare the experimental data to model predictions, and mention possible implications of the new results to other fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phonon lifetimes and mode softening in cubic Cs 2 AgBiBr 6

Metal halide perovskites (MHPs) have emerged as noteworthy candidates for photovoltaic applications in recent years. Their high power-conversion efficiency is largely attributed to the structure-function relationship, which is not well understood. In this study, we examine the low-frequency phonons of the double perovskite Cs 2 AgBiBr 6 using neutron inelastic scattering. We find that the acoustic phonon lifetimes decrease from 16 to 3 ps along Γ to X, which is indicative of significant anharmonicity that contributes to the ultralow thermal conductivity. Additionally, we observe a linear temperature dependence of the square of the zone-center soft optical phonon energy, which is consistent with a weakly first-order displacive cubic-tetragonal structural phase transition. These results provide a deeper understanding of the lattice dynamics and phase transitions in MHPs as well as the effects of anharmonicity by comparison with prototypical hybrid organic-inorganic MHPs, (CH 3 NH 3 ) PbX 3 (X = Br, I).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coherent π{sup 0}-photoproduction on the deuteron near the η-production threshold including polarization observables

Coherent π{sup 0}-photoproduction on the deuteron including polarization observables is studied in the energy region near the η-production threshold at backward center-of-mass angles of the outgoing pion. This work is motivated by the measurements of the CLAS Collaboration at Jefferson Lab, where a cusp-like structure in the energy dependence of the differential cross section has been observed at extremely backward pion angles. The present approach is based on the impulse approximation and first-order rescattering diagrams with intermediate production of both π- and η-mesons. Numerical results for unpolarized cross sections, the linear photon asymmetry (Σ), the vector (T{sub 11}) and tensor (T{sub 2M}, M=0, 1, 2) deuteron target asymmetries, and the double polarization E-asymmetry are predicted and compared with available experimental data and other theoretical models. The effect of first-order rescattering is found to be much larger in spin asymmetries than in the unpolarized cross sections. It reaches on average about 40% in the tensor target and E asymmetries. Compared to the experimental data from CLAS Collaboration, sizable discrepancies are found. This is not the case for the linear photon asymmetry, for which a better comparison with the data from YerPhI Collaboration is obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmological forecasts for future galaxy surveys with the linear point standard ruler: Toward consistent BAO analyses far from a fiducial cosmology

The linear point (LP) standard ruler was identified as the basis of a purely geometric method for exploiting the baryon acoustic oscillations (BAO). The LP exploits the BAO feature imprinted in the galaxy two-point correlation function to measure cosmological distances independent of any specific cosmological model. We forecast the expected precision of future and ongoing spectroscopic galaxy surveys to measure distances leveraging the linear point. We investigate the cosmological implications of our forecasted results. We focus in particular on a relevant working example: the detection of the late-time cosmic acceleration independent of other cosmological probes. Further, our findings show that, even within the Λ⁢CDM standard cosmological paradigm, estimated distances need to be reliable over a very wide parameter range in order to realize their maximum utility. This is particularly relevant if we aim to properly characterize cosmological tensions. The LP is a promising candidate approach to achieve this reliability. In contrast, widely employed procedures in BAO analysis estimate distances keeping fixed cosmological parameters to fiducial values close to cosmic-microwave-background constraints in flat-Λ⁢CDM. It is unclear whether they are purely geometric methods. Moreover, they rely on untested extrapolations to explore the parameter space away from those fiducial flat-Λ⁢CDM values. We recommend that all BAO methodologies be validated across the full range of models and parameters over which their results are quoted, first by means of linear predictions and then N -body simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic Vector Techniques in Ground-State Electronic Structure

Herein we review a suite of stochastic vector computational approaches for studying the electronic structure of extended condensed matter systems. These techniques help reduce algorithmic complexity, facilitate efficient parallelization, simplify computational tasks, accelerate calculations, and diminish memory requirements. While their scope is vast, we limit our study to ground-state and finite temperature density functional theory (DFT) and second-order many-body perturbation theory. More advanced topics, such as quasiparticle (charge) and optical (neutral) excitations and higher-order processes, are covered elsewhere. We start by explaining how to use stochastic vectors in computations, characterizing the associated statistical errors. Next, we show how to estimate the electron density in DFT and discuss effective techniques to reduce statistical errors. Finally, we review the use of stochastic vectors for calculating correlation energies within the second-order Møller-Plesset perturbation theory and its finite temperature variational form. Example calculation results are presented and used to demonstrate the efficacy of the methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Harmonic Resonant Kicker Design for the MEIC Electron Circular Cooler Ring

Bunched-beam electron cooling of the high-energy ion beam emittance may be a crucial technology for the proposed Medium energy Electron Ion Collider (MEIC) to achieve its design luminosity. A critical component is a fast kicker system in the Circular Ring (CR) that periodically switches electron bunches in and out of the ring from and to the driver Energy Recovery Linac (ERL). Compared to a conventional strip-line type kicker, a quarter-wave resonator (QWR)-based deflecting structure has a much higher shunt impedance and so requires much less RF power. The cavity has been designed to resonate simultaneously at many harmonic modes that are integer multiples of the fundamental mode. In this way the resulting waveform will kick only a subset of the circulating bunches. In this paper, analytical shunt impedance optimization, the electromagnetic simulations of this type of cavity, as well as tuner and coupler concept designs to produce 5 odd and 5 even harmonics of 47.63MHz will be presented, in order to kick every 10th bunch in a 476.3 MHz bunch train.

43 PARTICLE ACCELERATORS↗

Compression studies of TiB[subscript 2] using synchrotron x-ray diffraction

The compressibility of TiB{sub 2} has been determined separately by synchrotron x-ray diffraction and ultrasonic measurements on samples loaded in diamond-anvil cells and in multianvil high-pressure apparatus up to pressures of 65.9 GPa and 13.9 GPa, respectively, at ambient temperature. The high-pressure x-ray diffraction measurements, carried out on a pure polycrystalline sample, show a monotonic decrease of the lattice parameters with pressure, with the c/a ratio variation suggesting an increase in the structural rigidity along the c direction. No structural transition is observed even after laser heating of the sample up to 2200 K at 40 GPa, indicating a phase stability of TiB{sub 2} in this pressure range. The ultrasonic measurements of compressional V{sub p} and shear V{sub s} velocities on a cylindrical specimen show linear pressure dependencies. Using the third-order Eulerian finite strain equation to fit the pressure-volume x-ray data, we obtain an isothermal bulk modulus of K{sub To} = 232.9 {+-} 4.2 GPa and its pressure derivative K{sub To} = 3.86 {+-} 0.23. Similarly, the parameters derived from fitting the finite strain equation to the ultrasonic data give an adiabatic bulk modulus of K{sub So} = 232.9 {+-} 1.6 GPa and K'{sub So} = 3.02 {+-} 0.24, in good agreement with the x-ray diffraction measurements. The shear modulus and its pressure derivative derived from the ultrasonic measurements are G{sub So} = 259.8 {+-} 0.4 and G{sub So} = 2.52 {+-} 0.01, respectively.

43 PARTICLE ACCELERATORS↗

Instrument performance study on the short and long pulse options of the second Spallation Neutron Source target station

The Spallation Neutron Source (SNS) facility at the Oak Ridge National Laboratory is designed with an upgrade option for a future low repetition rate, long wavelength second target station. This second target station is intended to complement the scientific capabilities of the 1.4 MW, 60 Hz high power first target station. Two upgrade possibilities have been considered, the short and the long pulse options. In the short pulse mode, proton extraction occurs after the pulse compression in the accumulator ring. The proton pulse structure is thus the same as that for the first target station with a pulse width of ∼0.7 μs. In the long pulse mode, protons are extracted as they are produced by the linac, with no compression in the accumulator ring. The time width of the uncompressed proton pulse is ∼1 ms. This difference in proton pulse structure means that neutron pulses will also be different. Neutron scattering instruments thus have to be designed and optimized very differently for these two source options which will directly impact the overall scientific capabilities of the SNS facility. In order to assess the merits of the short and long pulse target stations, we investigated a representative suit of neutron scattering instruments and evaluated their performance under each option. Our results indicate that the short pulse option will offer significantly better performance for the instruments and is the preferred choice for the SNS facility.

43 PARTICLE ACCELERATORS↗

Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT

Purpose: MR image geometric integrity is one of the building blocks of MRI-guided radiotherapy. In particular, tissue magnetic susceptibility-induced effects are patient-dependent and their behavior is difficult to assess and predict. In this study, the authors investigated in detail the characteristics of susceptibility ({chi}) distortions in the context of MRIgRT, including the case of two common MR-linac system configurations. Methods: The magnetic field distortions were numerically simulated for several imaging parameters and anatomical sites, i.e., brain, lung, pelvis (with air pockets), and prostate. The simulation process consisted of (a) segmentation of patient CT data into susceptibility relevant anatomical volumes (i.e., soft-tissue, bone and air/lung), (b) conversion of CT data into susceptibility masks by assigning bulk {chi} values to the structures defined at (a), (c) numerical computations of the local magnetic fields by using a finite difference algorithm, and (d) generation of the geometric distortion maps from the magnetic field distributions. For each patient anatomy, the distortions were quantified at the interfaces of anatomical structures with significantly different {chi} values. The analysis was performed for two specific orientations of the external main magnetic field (B{sub 0}) characteristic to the MR-linac systems, specifically along the z-axis for a bore MR scanner and in the (x,y)-plane for a biplanner magnet. The magnetic field local perturbations were reported in ppm. The metrics used to quantify the geometric distortions were the maximum, mean, and range of distortions. The numerical simulation algorithm was validated using phantom data measurements. Results: Susceptibility-induced distortions were determined for both quadratic and patient specific geometries. The numerical simulations showed a good agreement with the experimental data. The measurements were acquired at 1.5 and 3 T and with an encoding gradient varying between 3 and 20 mT/m by using an annular phantom mimicking the water-air and water-oil {chi} interfaces. For quadratic geometries, the magnitude of field distortion increased rapidly with the size of the inhomogeneity up to about 10 mm and then tended to plateau. This trend became more evident for materials with a larger {Delta}{chi} relative to water. The simulations showed only a slight increase in the maximum distortion values when the B{sub 0} orientation was varied with regard to the shape of the {chi} inhomogeneity. In the case of patient anatomy, the largest distortion values arose at the air-soft-tissue interface. Considering the two MR-linac system configurations and comparing the field distortion values corresponding to all organ structures, the distortions tended to be larger for the biplanar magnet. The authors provide a reference table with ppm values which can be used to easily evaluate the geometric distortions for patient data as a function of B{sub 0} and the strength of the encoding gradient. Conclusions: The susceptibility distortions were quantified as a function of multiple parameters such as the {chi} inhomogeneity size and shape, the magnitude of B{sub 0} and the readout gradient, and the orientation of B{sub 0} with respect to the sample geometry. The analysis was performed for several anatomical sites and corresponding to two B{sub 0} orientations as featured by MR-linac systems.

60 APPLIED LIFE SCIENCES↗

Dosimetric and delivery efficiency investigation for treating hepatic lesions with a MLC-equipped robotic radiosurgery–radiotherapy combined system

Purpose: The CyberKnife M6 (CK-M6) Series introduced a multileaf collimator (MLC) for extending its capability from stereotactic radiosurgery/stereotactic radiotherapy (SBRT) to conventionally fractionated radiotherapy. This work is to investigate the dosimetric quality of plans that are generated using MLC-shaped beams on the CK-M6, as well as their delivery time, via comparisons with the intensity modulated radiotherapy plans that were clinically used on a Varian Linac for treating hepatic lesions. Methods: Nine patient cases were selected and divided into three groups with three patients in each group: (1) the group-one patients were treated conventionally (25 fractions); (2) the group-two patients were treated with SBRT-like hypofractionation (5 fractions); and (3) the group-three patients were treated similar to group-one patients, but with two planning target volumes (PTVs) and two different prescription dose levels correspondingly. The clinically used plans were generated on the ECLIPSE treatment planning system (TPS) and delivered on a Varian Linac (E-V plans). The multiplan (MP) TPS was used to replan these clinical cases with the MLC as the beam device for the CK-M6 (C-M plans). After plans were normalized to the same PTV dose coverage, comparisons between the C-M and E-V plans were performed based on D{sub 99%} (percentage of prescription dose received by 99% of the PTV), D{sub 0.1cm{sup 3}} (the percentage of prescription dose to 0.1 cm{sup 3} of the PTV), and doses received by critical structures. Then, the delivery times for the C-M plans will be obtained, which are the MP TPS generated estimations assuming having an imaging interval of 60 s. Results: The difference in D{sub 99%} between C-M and E-V plans is +0.6% on average (+ or − indicating a higher or lower dose from C-M plans than from E-V plans) with a range from −4.1% to +3.8%, and the difference in D{sub 0.1cm{sup 3}} was −1.0% on average with a range from −5.1% to +2.9%. The PTV conformity index (CI) for the C-M plans ranges from 1.07 to 1.29 with a mean of 1.19, slightly inferior to the E-V plans, in which the CI ranges from 1.00 to 1.15 with a mean of 1.07. Accounting for all nine patients in three groups, 45% of the critical structures received a lower mean dose for the C-M plans as compared with the E-V plans, and similarly, 48% received a lower maximum dose. Furthermore, the average difference of the mean critical structure dose between the C-M and E-V plans over all critical structures for all patients showed only +2.10% relative to the prescription dose and the similar comparison finds the average difference of the maximum critical structure dose of only +1.24%. The estimated delivery times for the C-M plans on the CK-M6 range from 18 to 24 minutes while they are from 7 to 13.7 min for the E-V plans on the Varian Linac. Conclusions: For treating hepatic lesions, for the C-M plans that are comparable to E-V plans in quality, the times needed to deliver these C-M plans on the CK-M6 are longer than the delivery time for the E-V plans on the Varian Linac, but may be clinically acceptable.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Reference Field for GCR Simulation and an LET-Based Implementation at NSRL

Exposure to galactic cosmic rays (GCR) on long duration deep space missions presents a serious health risk to astronauts, with large uncertainties connected to the biological response. In order to reduce the uncertainties and gain understanding about the basic mechanisms through which space radiation initiates cancer and other endpoints, radiobiology experiments are performed. Some of the accelerator facilities supporting such experiments have matured to a point where simulating the broad range of particles and energies characteristic of the GCR environment in a single experiment is feasible from a technology, usage, and cost perspective. In this work, several aspects of simulating the GCR environment in the laboratory are discussed. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at the NASA Space Radiation Laboratory (NSRL) limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is within physical uncertainties, allowing a single reference field for deep space missions to be defined. Third, an approach for simulating the reference field at NSRL is presented. The approach allows for the linear energy transfer (LET) spectrum of the reference field to be approximately represented with discrete ion and energy beams and implicitly maintains a reasonably accurate charge spectrum (or, average quality factor). Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the proposed strategy are discussed in this context.

Slaba, Tony C.↗

A Quest for Measuring Ion Bunch Longitudinal Profiles with One Picosecond Accuracy in the SNS Linac.

The SNS linac utilizes several accelerating structures operating at different frequencies and with different transverse focusing structures. Low-loss beam transport requires a careful matching at the transition points in both the transverse and longitudinal axes. Longitudinal beam parameters are measured using four Bunch Shape Monitors (used at many ion accelerator facilities, aka Feschenko devices). These devices, as initially delivered to the SNS, provided an estimated accuracy of about 5 picoseconds, which was sufficient for the initial beam commissioning. New challenges of improving beam transport for higher power operation will require measuring bunch profiles with 1-2 picoseconds accuracy. We have successfully implemented a number of improvements to maximize the performance characteristics of the delivered devices. We will discuss the current status of this instrument, its ultimate theoretical limit of accuracy, and how we measure its accuracy and resolution with real beam conditions.

43 PARTICLE ACCELERATORS↗

Measurement of Magnetic-Field Structures in a Laser-Wakefield Accelerator

Experimental measurements of magnetic fields generated in the cavity of a self-injecting laser-wakefield accelerator are presented. Faraday rotation is used to determine the existence of multimegagauss fields, constrained to a transverse dimension comparable to the plasma wavelength {approx}{lambda}{sub p} and several {lambda}{sub p} longitudinally. The fields are generated rapidly and move with the driving laser. In our experiment, the appearance of the magnetic fields is correlated with the production of relativistic electrons, indicating that they are inherently tied to the growth and wave breaking of the nonlinear plasma wave. This evolution is confirmed by numerical simulations, showing that these measurements provide insight into the wakefield evolution with high spatial and temporal resolution.

43 PARTICLE ACCELERATORS↗