Formal Analysis of the Remote Agent Before and After Flight

This paper describes two separate efforts that used the SPIN model checker to verify deep space autonomy flight software. The first effort occurred at the beginning of a spiral development process and found five concurrency errors early in the design cycle that the developers acknowledge would not have been found through testing. This effort required a substantial manual modeling effort involving both abstraction and translation from the prototype LISP code to the PROMELA language used by SPIN. This experience and others led to research to address the gap between formal method tools and the development cycle used by software developers. The Java PathFinder tool which directly translates from Java to PROMELA was developed as part of this research, as well as automatic abstraction tools. In 1999 the flight software flew on a space mission, and a deadlock occurred in a sibling subsystem to the one which was the focus of the first verification effort. A second quick-response "cleanroom" verification effort found the concurrency error in a short amount of time. The error was isomorphic to one of the concurrency errors found during the first verification effort. The paper demonstrates that formal methods tools can find concurrency errors that indeed lead to loss of spacecraft functions, even for the complex software required for autonomy. Second, it describes progress in automatic translation and abstraction that eventually will enable formal methods tools to be inserted directly into the aerospace software development cycle.

Havelund, Klaus↗

Modeling and Characterization of Cavity Backed Circular Aperture Antenna With Suspended Stripline Probe Feed

The paper presents the numerically simulated input impedance of a cavity backed circular aperture antenna with suspended substrate stripline probe feed. The simulation is based on the finite element method. The results show the input impedance or the return loss as a function of the frequency with the probe dimensions as parameters. The simulated results are validated by measurements at millimeter-wave frequencies.

Chun, Donghoon↗

Experimental Analysis of Reduced-Sized Coplanar Waveguide Transmission Lines

An experimental investigation of the use of capacitive loading of coplanar waveguides to reduce their line length and, thus the size, of monolithic microwave integrated circuits is presented. The reduced sized coplanar waveguides are compared to unloaded transmission lines and to lumped element transmission line segments. The phase bandwidth, defined by 2 percent error in S(sub 21), and the return loss bandwidth, defined by a return loss greater than 15 dB, of coplanar waveguides reduced from 0 to 90 percent are compared, and the insertion loss as a function of the size reduction is presented.

Ponchak, George E.↗

Aging attenuates the vestibulosympathetic reflex in humans

BACKGROUND: The vestibular system contributes to sympathetic activation by engagement of the otolith organs. However, there is a significant loss of vestibular function with aging. Therefore, the purpose of the present study was to determine if young and older individuals differ in their cardiovascular and sympathetic responses to otolithic stimulation (ie, head-down rotation, HDR). We hypothesized that responses to otolithic stimulation would be attenuated in older adults because of morphological and physiological alterations that occur in the vestibular system with aging. METHODS AND RESULTS: Arterial blood pressure, heart rate, muscle sympathetic nerve activity (MSNA), and head rotation were measured during HDR in 11 young (26 +/- 1 years) and 11 older (64 +/- 1 years) subjects in the prone posture. Five older subjects performed head rotation (chin to chest) in the lateral decubitus position, which simulates HDR but does not alter afferent inputs from the vestibular system. MSNA responses to HDR were significantly attenuated in older as compared with young subjects (P<0.01). MSNA increased in the older subjects by only 12 +/- 5% as compared with 85 +/- 16% in the young. Furthermore, HDR elicited significant reductions in mean arterial blood pressure in older (Delta-6 +/- 1 mm Hg; P<0.01) but not young subjects (Delta1 +/- 1 mm Hg). In contrast to HDR, head rotation performed in the lateral decubitus position did not elicit hypotension. MSNA responses to baroreceptor unloading and the cold pressor test were not different between the age groups. CONCLUSIONS: These data indicate that aging attenuates the vestibulosympathetic reflex in humans and may contribute to the increased prevalence of orthostatic hypotension with age.

NASA Discipline Neuroscience↗

Review of the biological effects of weightlessness on the human endocrine system

Studies from space flights over the past two decades have demonstrated that there are basic physiological changes in humans during space flight. These changes include cephalad fluid shifts, loss of fluid and electrolytes, loss of muscle mass, space motion sickness, anemia, reduced immune response, and loss of calcium and mineralized bone. The cause of most of these manifestations is not known but the general approach has been to investigate systemic and hormonal changes. However, data from the 1973-1974 Skylabs, Spacelab 3 (SL-3), Spacelab D-I (SL-DI), and now the new SLS-1 missions support a more basic biological response to microgravity that may occur at the tissue, cellular, and molecular level. This report summarizes ground-based and SLS-1 experiments that examined the mechanism of loss of red blood cell mass in humans, the loss of bone mass and lowered osteoblast growth under space flight conditions, and loss of immune function in microgravity.

STS-40 Shuttle Project↗

Analytical Ion Thruster Discharge Performance Model

A particle and energy balance model of the plasma discharge in magnetic ring-cusp ion thrusters has been developed. The model follows the original work of Brophy in the development of global 0-D discharge models that utilize conservation of particles into and out of the thruster and conservation of energy into the discharge and out of the plasma in the form of charged particles to the walls and beam and plasma radiation. The present model is significantly expanded over Brophy's original work by including self-consistent calculations of the internal neutral pressure, electron temperature, primary electron density, electrostatic ion confinement (due to the ring-cusp fields), plasma potential, discharge stability, and time dependent behavior during recycling. The model only requires information on the thruster geometry, ion optics performance and electrical inputs such as discharge voltage and currents, etc. to produce accurate performance curves of discharge loss versus mass utilization efficiency. The model has been benchmarked against the NEXIS Laboratory Model (LM) and Development Model (DM) thrusters, and successfully predicts the thruster discharge loss as a function of mass utilization efficiency for a variety of thrusters. The discharge performance model will be presented and results showing ion thruster performance and stability given.

discharge chambers↗

Simulating Bone Loss in Microgravity Using Mathematical Formulations of Bone Remodeling

Most mathematical models of bone remodeling are used to simulate a specific bone disease, by disrupting the steady state or balance in the normal remodeling process, and to simulate a therapeutic strategy. In this work, the ability of a mathematical model of bone remodeling to simulate bone loss as a function of time under the conditions of microgravity is investigated. The model is formed by combining a previously developed set of biochemical, cellular dynamics, and mechanical stimulus equations in the literature with two newly proposed equations; one governing the rate of change of the area of cortical bone tissue in a cross section of a cylindrical section of bone and one governing the rate of change of calcium in the bone fluid. The mechanical stimulus comes from a simple model of stress due to a compressive force on a cylindrical section of bone which can be reduced to zero to mimic the effects of skeletal unloading in microgravity. The complete set of equations formed is a system of first order ordinary differential equations. The results of selected simulations are displayed and discussed. Limitations and deficiencies of the model are also discussed as well as suggestions for further research.

Pennline, James A.↗

Accurate Adaptive Level Set Method and Sharpening Technique for Three Dimensional Deforming Interfaces

In this paper, we demonstrate improved accuracy of the level set method for resolving deforming interfaces by proposing two key elements: (1) accurate level set solutions on adapted Cartesian grids by judiciously choosing interpolation polynomials in regions of different grid levels and (2) enhanced reinitialization by an interface sharpening procedure. The level set equation is solved using a fifth order WENO scheme or a second order central differencing scheme depending on availability of uniform stencils at each grid point. Grid adaptation criteria are determined so that the Hamiltonian functions at nodes adjacent to interfaces are always calculated by the fifth order WENO scheme. This selective usage between the fifth order WENO and second order central differencing schemes is confirmed to give more accurate results compared to those in literature for standard test problems. In order to further improve accuracy especially near thin filaments, we suggest an artificial sharpening method, which is in a similar form with the conventional re-initialization method but utilizes sign of curvature instead of sign of the level set function. Consequently, volume loss due to numerical dissipation on thin filaments is remarkably reduced for the test problems

Kim, Hyoungin↗

Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane

The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor inputs (e.g., somatosensory) or other circulatory reflex mechanisms.

Wood, Scott J.↗

Evaluation of Technologies to Prevent Precipitation During Water Recovery from Urine

The International Space Station (ISS) Urine Processor Assembly (UPA) experienced a hardware failure in the Distillation Assembly (DA) in October 2010. Initially the UPA was operated to recover 85% of the water from urine through distillation, concentrating the contaminants in the remaining urine. The DA failed due to precipitation of calcium sulfate (gypsum) which caused a loss of UPA function. The ISS UPA operations have been modified to only recover 70% of the water minimizing gypsum precipitation risk but substantially increasing water resupply needs. This paper describes the feasibility assessment of several technologies (ion exchange, chelating agents, threshold inhibitors, and Lorentz devices) to prevent gypsum precipitation. The feasibility assessment includes the development of assessment methods, chemical modeling, bench top testing, and validation testing in a flight-like ground UPA unit. Ion exchange technology has been successfully demonstrated and has been recommended for further development. The incorporation of the selected technology will enable water recovery to be increased from 70% back to the original 85% and improve the ISS water balance.

Broyan, James L., Jr.↗

Simulated Beam Extraction Performance Characterization of a 50-cm Ion Thruster Discharge

A 50 cm ion thruster is being developed to operate at >65 percent total efficiency at 11 kW, 2700 s Isp and over 25 kW, 4500 s Isp at a total efficiency of >75 percent. The engine is being developed to address the need for a multimode system that can provide a range of thrust-to- power to service national and commercial near-earth onboard propulsion needs such as station-keeping and orbit transfer. Operating characteristics of the 50 cm ion thruster were measured under simulated beam extraction. The discharge current distribution at the various magnet rings was measured over a range of operating conditions. The relationship between the anode current distribution and the resulting plasma uniformity and ion flux measured at the thruster exit plane is discussed. The thermal envelope will also be investigated through the monitoring of magnet temperatures over the range of discharge powers investigated. Discharge losses as a function of propellant utilization was also characterized at multiple simulated beam currents. Bulk plasma conditions such as electron temperature and electron density near engine centerline was measured over a range of operating conditions using an internal Langmuir probe. Sensitivity of discharge performance to chamber length is also discussed. This data acquired from this discharge study will be used in the refinement of a throttle table in anticipation for eventual beam extraction testing.

Foster, John E.↗

Optic Nerve Sheath Mechanics in VIIP Syndrome

Visual Impairment and Intracranial Pressure (VIIP) syndrome results in a loss of visual function and occurs in astronauts following long-duration spaceflight. Understanding the mechanisms that lead to the ocular changes involved in VIIP is of critical importance for space medicine research. Although the exact mechanisms of VIIP are not yet known, it is hypothesized that microgravity-induced increases in intracranial pressures (ICP) drive the remodeling of the optic nerve sheath, leading to compression of the optic nerve which in turn may reduce visual acuity. Some astronauts present with a kink in the optic nerve after return to earth, suggesting that tissue remodeling in response to ICP increases may be taking place. The goal of this work is to characterize the mechanical properties of the optic nerve sheath (dura mater) to better understand its biomechanical response to increased ICP.

microgravity↗

The Use of Microgravity Simulators for Space Research

The spaceflight environment is known to influence biological processes ranging from stimulation of cellular metabolism to possible impacts on cellular damage repair, suppression of immune functions, and bone loss in astronauts. Microgravity is one of the most significant stress factors experienced by living organisms during spaceflight, and therefore, understanding cellular responses to altered gravity at the physiological and molecular level is critical for expanding our knowledge of life in space. Since opportunities to conduct experiments in space are scarce, various microgravity simulators and analogues have been widely used in space biology ground studies. Even though simulated microgravity conditions have produced some, but not all of the biological effects observed in the true microgravity environment, they provide test beds that are effective, affordable, and readily available to facilitate microgravity research. A Micro-g Simulator Center is being developed at Kennedy Space Center (KSC) to offer a variety of microgravity simulators and platforms for Space Biology investigators. Assistance will be provided by both KSC and external experts in molecular biology, microgravity simulation, and engineering. Comparisons between the physical differences in microgravity simulators, examples of experiments using the simulators, and scientific questions regarding the use of microgravity simulators will be discussed.

Simulation↗

The Use of Microgravity Simulators for Space Research

The spaceflight environment is known to influence biological processes ranging from stimulation of cellular metabolism to possible impacts on cellular damage repair, suppression of immune functions, and bone loss in astronauts. Microgravity is one of the most significant stress factors experienced by living organisms during spaceflight, and therefore, understanding cellular responses to altered gravity at the physiological and molecular level is critical for expanding our knowledge of life in space. Since opportunities to conduct experiments in space are scarce, various microgravity simulators and analogues have been widely used in space biology ground studies. Even though simulated microgravity conditions have produced some, but not all of the biological effects observed in the true microgravity environment, they provide test beds that are effective, affordable, and readily available to facilitate microgravity research. Kennedy Space Center (KSC) provides ground microgravity simulator support to offer a variety of microgravity simulators and platforms for Space Biology investigators. Assistance will be provided by both KSC and external experts in molecular biology, microgravity simulation, and engineering. Comparisons between the physical differences in microgravity simulators, examples of experiments using the simulators, and scientific questions regarding the use of microgravity simulators will be discussed.

Simulation↗

Polyurethane Microparticles for Stimuli Response and Reduced Oxidative Degradation in Highly Porous Shape Memory Polymers

Shape memory polymers (SMPs) have been found to be promising biomaterials for a variety of medical applications; however, the clinical translation of such technology is dependent on tailorable properties such as gravimetric changes in degradation environments. For SMPs synthesized from amino-alcohols, oxidation resulting in rapid mass loss may be problematic in terms of loss of material functionality as well as toxicity and cytocompatibility concerns. Control of gravimetric changes was achieved through the incorporation of small molecule antioxidants, either directly into the polymer matrix or included in microparticles to form a SMP composite material. Direct incorporation of small molecule antioxidants, such as phenolic alcohols, was found to alter shape memory attributes and increase elastic modulus at the expense of the strain to failure. Such changes could not ensure retention of the antioxidants and therefore did not increase oxidative stability. However, the inclusion of antioxidants in microparticles was found to produce materials with similar thermomechanical and shape memory properties while increasing oxidative resistance compared to controls. The microparticle composite SMPs also act as a platform for environmental sensing, such as pH-dependent fluorescence shifts and payload release, as demonstrated by fluorescent dyes and the release of antioxidants. The use of polyurethane-urea microparticles in porous SMPs is demonstrated to increase biostability of the materials, by approximately 25%, and ultimately extend their lifespan for use in aneurysm occlusion as determined through calculated in vivo degradation rates corresponding to a porcine aneurysm environment.

Weems, A. C.↗

Gene Expression and Structural Skeletal Responses to Long-Duration Simulated Microgravity in Rats

Spaceflight has deleterious effects on skeletal structure and function, specifically causingprofound loss in bone mass, density, and strength, as well as changes in expression levels of genes related to oxidative stress [Hyeon et al., Smith et al.]. It is known that bone resorption remains elevated after spaceflight and that bone density and strength fail to recover completely even years following spaceflight [Smith et al., Carpenter et al.]. However, our current understanding of the signaling pathways and molecular mechanisms that control bone loss and that link oxidative stress, bone resorption, and mechanical unloading of skeletal tissue is incomplete. Here, we aim to examine skeletal responses to simulated long-duration spaceflight on bone loss using the ground-based hindlimb unloading (HU) model in adult (9 months old) male rats. We hypothesized that simulated microgravity leads to the temporal regulation of oxidative-defense genes and pro-osteoclastogenic factors, showing progression and eventual plateau during long-term unloading, and that transient changes at early timepoints in these pathways precede skeletal adaptations to long-duration unloading. We will identify oxidativestress and bone resorption-related changes using global gene expression analysis (Affymetrix arrays) for both acute (within 14 days) and long-term timepoints (90 days). We will also use quantitative PCR to examine changes in expression of genes related to oxidative metabolism (e.g. Nrf2, SOD-1), bone turnover (resorption and formation markers, e.g. TRAP, osteocalcin respectively, SOST), and osteoclastogenesis (e.g. RANKL, OPG) at both early and late timepoints. We will then use detailed microarchitectural and structural analysis through microcomputed tomography to relate gene expression changes with structural changes in bone, expecting that plateaus in gene expression correlate with long-term changes in bone microarchitecture.

Rael, Victoria E.↗

Temporal Changes in Astronauts’ Muscle and Cardiorespiratory Physiology Before, During and After Spaceflight

Background: NASA’s planned space exploration missions will require astronauts to safely perform extravehicular activity (EVA) and to safely egress vehicles in a variety of landing scenarios. Prolonged exposure to spaceflight can diminish tolerance for physical activity, decrease cardiovascular and sensorimotor function, and cause loss of bone mineral density, and reduced muscle mass and strength. Although exercise can mitigate these spaceflight-induced physiological decrements, little is known regarding the time-course of changes in muscle and aerobic performance during spaceflight. Furthermore, these exercise countermeasures are not fully protective. For example, maximal aerobic capacity (VO2pk), lower body muscle cross-sectional area, and strength decrease by about 10% to 15% after short- (~ 14 days) and long-duration (~ 6 months) missions on the International Space Station (ISS). Future space missions that are longer in duration and further from Earth will employ exploration vehicles that will have exercise hardware with less robust and more constrained exercise capabilities than of those available on the ISS. Thus, countermeasures will need to be optimized to protect crew health and performance on exploration-class missions that will last up to 3 years. This will require a more detailed understanding of the dynamic effects of spaceflight on human health and performance, and the ability of exercise to protect against this deconditioning, and the interaction of exercise with interrelated factors like nutrition, sleep, and environmental conditions. Methods: We will use standardized research and medical testing protocols previously validated in 1-G and 0-G to quantify the time course and the inter-individual variability of changes in physical performance, including cardiorespiratory fitness, and muscle strength, and endurance, before, during and after spaceflight missions lasting 2 months, 6 months, and 1 year. Additionally, we will use an extrapolation model to predict changes associated with 2–3-year exploration missions. Additionally, we will monitor in-flight exercise, nutrition, and sleep using in-flight assessment tools. Significance: Our testing protocols will provide valuable information for determining time course of change and the interindividual variability of spaceflight-induced deconditioning of aerobic capacity and muscle strength and endurance over the course of spaceflight missions up to and beyond 1 year. This information will be vital to assess whether humans can be physically ready for deep space exploration, such as on a mission to Mars, using current technology, or if additional mitigation strategies are necessary.

countermeasures↗

Oculometric Detection and Characterization of Sub-Clinical Visual/Visuomotor Impairment

It has long been known that qualitative abnormalities in eye movements can be used to diagnose overt brain pathologies (Diefendorf & Dodge, 1908; Fox & Holmes, 1926; Leigh & Zee, 2015). Here, we will examine the use of a set of quantitative measures of the human behavioral response (oculometrics) in a 5-minute radial ocular tracking task (Krukowski & Stone, 2005) with sufficient temporal, spatial, and directional uncertainty to minimize the contribution of a priori prediction or anticipation, and to emphasize the use of a posteriori visual processing of the stimulus trajectory (Liston & Stone, 2014). The derived oculometrics provide a largely independent, reliable set of metrics that are sensitive enough to detect mild sub-clinical impairment across a range of possible neural loci (Stone et al., 2019) with the pattern of impairment across the set providing specificity as to its nature (Tyson et al., 2023). We will review our earlier findings where oculometrics have been used to detect mild impairment due to traumatic brain injury, sleep loss, and low-dose alcohol (Liston et al., 2017; Stone et al., 2019; Tyson et al., 2021). We will also report on a recent clinical study of asymptomatic patients at risk of retinal pathology (Leung et al., 2022) and show that oculometrics can detect and characterize substantive loss of visual function in the absence of clinical indicators of pathology. We conclude that oculometric testing could be used as a routine non-invasive ophthalmological or neurological tool to aid in the early detection and diagnosis of neural injury, toxicity, or disease.

eye movements↗