Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Rescoring Docking Hit Lists for Model Cavity Sites: Predictions And Experimental Testing

Molecular docking computationally screens thousands to millions of organic molecules against protein structures, looking for those with complementary fits. Many approximations are made, often resulting in low 'hit rates'. A strategy to overcome these approximations is to rescore top-ranked docked molecules using a better but slower method. One such is afforded by molecular mechanics-generalized Born surface area (MM-GBSA) techniques. These more physically realistic methods have improved models for solvation and electrostatic interactions and conformational change compared to most docking programs. To investigate MM-GBSA rescoring, we re-ranked docking hit lists in three small buried sites: a hydrophobic cavity that binds apolar ligands, a slightly polar cavity that binds aryl and hydrogen-bonding ligands, and an anionic cavity that binds cationic ligands. These sites are simple; consequently, incorrect predictions can be attributed to particular errors in the method, and many likely ligands may actually be tested. In retrospective calculations, MM-GBSA techniques with binding-site minimization better distinguished the known ligands for each cavity from the known decoys compared to the docking calculation alone. This encouraged us to test rescoring prospectively on molecules that ranked poorly by docking but that ranked well when rescored by MM-GBSA. A total of 33 molecules highly ranked by MM-GBSA for the three cavities were tested experimentally. Of these, 23 were observed to bind-these are docking false negatives rescued by rescoring. The 10 remaining molecules are true negatives by docking and false positives by MM-GBSA. X-ray crystal structures were determined for 21 of these 23 molecules. In many cases, the geometry prediction by MM-GBSA improved the initial docking pose and more closely resembled the crystallographic result; yet in several cases, the rescored geometry failed to capture large conformational changes in the protein. Intriguingly, rescoring not only rescued docking false positives, but also introduced several new false positives into the top-ranking molecules. We consider the origins of the successes and failures in MM-GBSA rescoring in these model cavity sites and the prospects for rescoring in biologically relevant targets.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Gaps, Size Effect, and Corner-Turning in Ambient LX-17

Various ambient measurements are presented for LX-17. The size (diameter) effect has been measured with copper and Lucite confinement, where the failure radii are 4.0 and 6.5 mm, respectively. The air well corner-turn has been measured with an LX-07 booster, and the dead-zone results are comparable to the previous TATB-boosted work. Four double cylinders have been fired, and dead zones appear in all cases. The steel-backed samples are faster than the Lucite-backed samples by 0.6 {micro}s. Bare LX-07 and LX-17 of 12.7 mm-radius were fired with air gaps. Long acceptor regions were used to truly determine if detonation occurred or not. The LX-07 crossed at 10 mm with a slight time delay. Steady state LX-17 crossed at 3.5 mm gap but failed to cross at 4.0 mm. LX-17 with a 12.7 mm run after the booster crossed a 1.5 mm gap but failed to cross 2.5 mm. Timing delays were measured where the detonation crossed the gaps. The Tarantula model is introduced as embedded in 0 reactive flow JWL++ and Linked Cheetah V4, mostly at 4 zones/mm. Tarantula has four pressure regions: off, initiation, failure and detonation. The physical basis of the input parameters is considered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alternative materials to cadmium for neutron absorbers in safeguards applications

Cadmium is increasingly difficult to use in safeguards applications because of rising cost and increased safety regulations. This work examines the properties of two materials produced by Ceradyne, inc. that present alternatives to cadmium for neutron shielding. The first is an aluminum metal doped with boron and the second is a boron carbide powder, compressed into a ceramic. Both are enriched in the {sup 10}B isotope. Two sheets of boron doped aluminum (1.1 mm and 5.2mm thick) and one sheet of boron carbide (8.5mm thick) were provided by Ceradyne for testing. An experiment was designed to test the neutron absorption capabilities of these three sheets against two different thicknesses of cadmium (0.6mm and 1.6mm thick). The thinner piece of aluminum boron alloy (1.1mm) performed as well as the cadmium pieces at absorbing neutrons. The thicker aluminum-boron plate provided more shielding than the cadmium sheets and the boron carbide performed best by a relatively large margin. Monte Carlo N-Particle eXtended (MCNPX) transport code modeling of the experiment was performed to provide validaLed computational tools for predicting the behavior of systems in which these materials may be incorporated as alternatives to cadmium. MCNPX calculations predict that approximately 0.17mm of the boron carbide is equivalent to 0.6mm of cadmium. There are drawbacks to these materials that need to be noted when considering using them as replacements for cadmium. Notably, they may need to be thicker than cadmium, and are not malleable, requiring machining to fit any curved forms.

35↗

Synchrotron-Based Micro-CT Imaging of the Human Lung Acinus

Structural data about the human lung fine structure are mainly based on stereological methods applied to serial sections. As these methods utilize 2D images, which are often not contiguous, they suffer from inaccuracies which are overcome by analysis of 3D micro-CT images of the never-sectioned specimen. The purpose of our study was to generate a complete data set of the intact three-dimensional architecture of the human acinus using high-resolution synchrotron-based micro-CT (synMCT). A human lung was inflation-fixed by formaldehyde ventilation and then scanned in a 64-slice CT over its apex to base extent. Lung samples (8-mm diameter, 10-mm height, N = 12) were punched out, stained with osmium tetroxide, and scanned using synMCT at (4 {micro}m){sup 3} voxel size. The lung functional unit (acinus, N = 8) was segmented from the 3D tomographic image using an automated tree-analysis software program. Morphometric data of the lung were analyzed by ANOVA. Intra-acinar airways branching occurred over 11 generations. The mean acinar volume was 131.3 {+-} 29.2 mm{sup 3} (range, 92.5-171.3 mm{sup 3}) and the mean acinar surface was calculated with 1012 {+-} 26 cm{sup 2}. The airway internal diameter (starting from the bronchiolus terminalis) decreases distally from 0.66 {+-} 0.04 mm to 0.34 {+-} 0.06 mm (P < 0.001) and remains constant after the seventh generation (P < 0.5). The length of each generation ranges between 0.52 and 0.93 mm and did not show significant differences between the second and eleventh generation. The branching angle between daughter branches varies between 113-degree and 134-degree without significant differences between the generations (P < 0.3). This study demonstrates the feasibility of quantitating the 3D structure of the human acinus at the spatial resolution readily achievable using synMCT.

59 BASIC BIOLOGICAL SCIENCES↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Porous Gelatin Particles for Uterine Artery Embolization: An Experimental Study of Intra-Arterial Distribution, Uterine Necrosis, and Inflammation in a Porcine Model

PurposeWe evaluated the location of porous gelatin particles (GP; Gelpart; Nippon Kayaku/Astellas, Tokyo, Japan) within the arterial vasculature and their acute effects on uterine necrosis and inflammation after uterine artery embolization (UAE) in swine.Materials and MethodsAdult nonpregnant pigs (n = 6) were allocated to either 1- (n = 3) or 2-mm GP (n = 3). Superselective and bilateral embolization of the uterine arteries was performed. All animals were killed 1 week after UAE. Macroscopic and microscopic findings, including the level of arterial occlusion and their effect on uterine necrosis and inflammation, were analyzed.ResultsAll UAE procedures were completed without severe complications. The macroscopic necrosis was seen in two animals in the 2-mm group with an extent of <50%. The location of the occluded arteries did not differ significantly between groups. The median diameters of the occluded arteries were 449 {mu}m (95% confidence interval [CI] 417-538 {mu}m) in the 1-mm GP group and 484 {mu}m (95% CI 370-560 {mu}m) in the 2-mm GP group. As for microscopic necrosis, no statistically significant difference was observed. The qualitative inflammatory reaction was significantly greater in the 2-mm GP group than in the 1-mm group (p < 0.001).ConclusionsBoth 1- and 2-mm GP occluded the arteries relevant to the target diameter for UAE in porcine uterus, presumably due to the plastic deformity. Both sizes of GP were associated with limited areas of necrosis; however, evaluation of inflammatory reaction was preliminary. Further study with adequate evaluation of inflammatory reactions is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Margin Size is an Independent Predictor of Local Tumor Progression After Ablation of Colon Cancer Liver Metastases

This study was designed to evaluate the relationship between the minimal margin size and local tumor progression (LTP) following CT-guided radiofrequency ablation (RFA) of colorectal cancer liver metastases (CLM). An institutional review board-approved, HIPPA-compliant review identified 73 patients with 94 previously untreated CLM that underwent RFA between March 2003 and May 2010, resulting in an ablation zone completely covering the tumor 4-8 weeks after RFA dynamic CT. Comparing the pre- with the post-RFA CT, the minimal margin size was categorized to 0, 1-5, 6-10, and 11-15 mm. Follow-up included CT every 2-4 months. Kaplan-Meier methodology and Cox regression analysis were used to evaluate the effect of the minimal margin size, tumor location, size, and proximity to a vessel on LTP. Forty-five of 94 (47.9 %) CLM progressed locally. Median LTP-free survival (LPFS) was 16 months. Two-year LPFS rates for ablated CLM with minimal margin of 0, 1-5 mm, 6-10 mm, 11-15 mm were 26, 46, 74, and 80 % (p < 0.011). Minimal margin (p = 0.002) and tumor size (p = 0.028) were independent risk factors for LTP. The risk for LTP decreased by 46 % for each 5-mm increase in minimal margin size, whereas each additional 5-mm increase in tumor size increased the risk of LTP by 22 %. An ablation zone with a minimal margin uniformly larger than 5 mm 4-8 weeks postablation CT is associated with the best local tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Evaluation of Lung Microwave Ablation in a Porcine Tumor Mimic Model

To evaluate the microwave ablation of created tumor mimics in the lung of a large animal model (pigs), with examination of the ablative synergy of multiple antennas. Fifty-six tumor-mimic models of various sizes were created in 15 pigs by using barium-enriched minced collected thigh muscle injected into the lung of the same animal. Tumors were ablated under fluoroscopic guidance by single-antenna and multiple-antenna microwaves. Thirty-five tumor models were treated in 11 pigs with a single antenna at 75 W for 15 min, with 15 measuring 20 mm in diameter, 10 measuring 30 mm, and 10 measuring 40 mm. Mean circularity of the single-antenna ablation zones measured 0.64 {+-} 0.12, with a diameter of 35.7 {+-} 8.7 mm along the axis of the antenna and 32.7 {+-} 12.8 mm perpendicular to the feeding point. Multiple-antenna delivery of 75 W for 15 min caused intraprocedural death of 2 animals; modified protocol to 60 W for 10 min resulted in an ablation zone with a diameter of 43.0 {+-} 7.7 along the axis of the antenna and 54.8 {+-} 8.5 mm perpendicular to the feeding point; circularity was 0.70 {+-} 0.10. A single microwave antenna can create ablation zones large enough to cover lung tumor mimic models of {<=}4 cm with no heat sink effect from vessels of {<=}6 mm. Synergic use of 3 antennas allows ablation of larger volumes than single-antenna or radiofrequency ablation, but great caution must be taken when 3 antennas are used simultaneously in the lung in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Application of CSC-Roll for Heavy Reduction of the Bloom Continuous Casting Process

Center quality control is a key issue affecting large-section bloom production and product quality. The central convex roll could avoid the bloom side part and yield a high reduction amount, which benefit the implement of heavy reduction (HR) for bloom continuous casting process without upgrading the mechanical and hydraulic system of withdrawal and straightening machine. In this work, a curving surface convex roll (CSC-Roll), which could significantly improve bloom center quality, was designed by finite element simulation for a 360 mm × 450 mm #45 steel continuous casting bloom. The optimal roll surface shape of the CSC-Roll was determined based on an analysis of the distribution of the reduction amount in the bloom center and the strain of the bloom centerline and inner surface. The calculation results showed that the optimal size of the CSC-Roll was 200 mm in convex platform region length, 30 mm in convex platform region height, and 80 mm in gradient curvature region length. The bloom heat transfer and deformation behavior in the CSC-Roll reduction process were then analyzed. The results showed that in the CSC-Roll HR process, 61.71 pct of the reduction amount could be transmitted to the inner side of the porosity zone. Macrographs of the 360 mm × 450 mm #45 steel continuous casting bloom proved that the bloom center quality was significantly improved after CSC-Roll HR was applied.

36 MATERIALS SCIENCE↗

Cooperative Formation of Icosahedral Proline Clusters from Dimers

Ion mobility spectrometry-mass spectrometry and Fourier transform infrared spectroscopy (FTIR) techniques were combined with quantum chemical calculations to examine the origin of icosahedral clusters of the amino acid proline. When enantiopure proline solutions are electrosprayed (using nanospray) from 100 mM ammonium acetate, only three peaks are observed in the mass spectrum across a concentration range of five orders of magnitude: a monomer [Pro+H]{sup +} species, favored from 0.001 to 0.01 mM proline concentrations; a dimer [2Pro+H]{sup +} species, the most abundant species for proline concentrations above 0.01 mM; and, the dimer and dodecamer [12Pro+2H]{sup 2+} for 1.0 mM and more concentrated proline solutions. Electrospraying racemic D/L-proline solutions from 100 mM ammonium acetate leads to a monomer at low proline concentrations (0.001 to 0.1 mM), and a dimer at higher concentrations (>0.09 mM), as well as a very small population of 8 to 15 Pro clusters that comprise <0.1% of the total ion signals even at the highest proline concentration. Solution FTIR studies show unique features that increase in intensity in the enantiopure proline solutions, consistent with clustering, presumably from the icosahedral geometry in bulk solution. When normalized for the total proline, these results are indicative of a cooperative formation of the enantiopure 12Pro species from 2Pro. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Investigation of Natural Convection Heat Transfer in Heated Vertical Tubes with Discrete Rings

Natural convection heat transfer from heated vertical pipes has been investigated experimentally. The pipes are open-ended and circular in cross section. The test sections are electrically heated imposing the circumferentially and axially constant wall heat flux. The outer surface of the test section is insulated and heat is allowed to dissipate from the internal surface. Experiments are carried out for four different channels of 45 mm internal diameter and 3.8 mm thickness with length varying from 450 mm to 850 mm. Ratios of length to diameter of the channel are taken as L/D = 10, 12.22, 15.56, and 18.89. Wall heat fluxes are maintained at q{sup //} = 250 to 3341 W/m{sup 2}. Experiments are also carried out on intensified tubes of the same geometrical sizes with the discrete rings of rectangular cross section provided on the internal surface. Thickness of the rings are taken as t = 4, 6 and 8 mm; step size (s) of the rings are varying from 75 mm to 283.3 mm and the other ratios are taken as s/D = 1.67 to 6.29, t/D = 0.088 to 0.178 and s / t = 9.38 to 70.82. The effects of L/D ratio, ring thickness, ring spacing and wall heating conditions on local steady-state heat transfer phenomena are studied. A correlation is developed for average Nusselt number and modified Rayleigh number and another correlation is also developed for modified Rayleigh number and modified Reynolds number. These correlations predict the data accurately within ±10% error.

42 ENGINEERING↗

The human insulin mRNA is partly translated via a cap- and eIF4A-independent mechanism

Highlights: {yields} The polypyrimidine tract binding protein binds to the 5'-UTR of the insulin mRNA. {yields} Insulin mRNA can be translated via a cap-independent mechanism. {yields} The fraction cap-independent insulin synthesis increases during conditions of stress. {yields} The {beta}-cell is able to uphold basal insulin biosynthesis under conditions of stress. -- Abstract: The aim of this study was to investigate whether cap-independent insulin mRNA translation occurs in human pancreatic islets at basal conditions, during stimulation at a high glucose concentration and at conditions of nitrosative stress. We also aimed at correlating cap-independent insulin mRNA translation with binding of the IRES trans-acting factor polypyrimidine tract binding protein (PTB) to the 5'-UTR of insulin mRNA. For this purpose, human islets were incubated for 2 h in the presence of low (1.67 mM) or high glucose (16.7 mM). Nitrosative stress was induced by addition of 1 mM DETA/NO and cap-dependent mRNA translation was inhibited with hippuristanol. Insulin biosynthesis rates were determined by radioactive labeling and immunoprecipitation. PTB affinity to insulin mRNA 5'-UTR was assessed by a magnetic micro bead pull-down procedure. We observed that in the presence of 1.67 mM glucose, approximately 70% of the insulin mRNA translation was inhibited by hippuristanol. Corresponding value from islets incubated at 16.7 mM glucose was 93%. DETA/NO treatment significantly decreased the translation of insulin by 85% in high glucose incubated islets, and by 50% at a low glucose concentration. The lowered insulin biosynthesis rates of DETA/NO-exposed islets were further suppressed by hippuristanol with 55% at 16.7 mM glucose but not at 1.67 mM glucose. Thus, hippuristanol-induced inhibition of insulin biosynthesis was less pronounced in DETA/NO-treated islets as compared to control islets. We observed also that PTB bound specifically to the insulin mRNA 5'-UTR in vitro, and that this binding corresponded well with rates of cap-independent insulin biosynthesis at the different conditions. In conclusion, our studies show that insulin biosynthesis is mainly cap-dependent at a high glucose concentration, but that the cap-independent biosynthesis of insulin can constitute as much as 40-100% of all insulin biosynthesis during conditions of nitrosative stress. These data suggest that the pancreatic {beta}-cell is able to uphold basal insulin synthesis at conditions of starvation and stress via a cap- and eIF4A-independent mechanism, possibly mediated by the binding of PTB to the 5'-UTR of the human insulin mRNA.

60 APPLIED LIFE SCIENCES↗

miR-320a regulates cell proliferation and apoptosis in multiple myeloma by targeting pre-B-cell leukemia transcription factor 3

Aberrant expression of microRNAs (miRNAs) is implicated in cancer development and progression. While miR-320a is reported to be deregulated in many malignancy types, its biological role in multiple myeloma (MM) remains unclear. Here, we observed reduced expression of miR-320a in MM samples and cell lines. Ectopic expression of miR-320a dramatically suppressed cell viability and clonogenicity and induced apoptosis in vitro. Mechanistic investigation led to the identification of Pre-B-cellleukemia transcription factor 3 (PBX3) as a novel and direct downstream target of miR-320a. Interestingly, reintroduction of PBX3 abrogated miR-320a-induced MM cell growth inhibition and apoptosis. In a mouse xenograft model, miR-320a overexpression inhibited tumorigenicity and promoted apoptosis. Our findings collectively indicate that miR-320a inhibits cell proliferation and induces apoptosis in MM cells by directly targeting PBX3, supporting its utility as a novel and potential therapeutic agent for miRNA-based MM therapy. -- Highlights: •Expression of miR-320a in MM cell induces apoptosis in vitro. •miR-320a represses PBX3 via targeting specific sequences in the 3′UTR region. •Exogenous expression of PBX3 reverses the effects of miR-320a in inhibiting MM cell growth and promoting apoptosis. •Overexpression of miR-320a inhibits tumor growth and increases apoptosis in vivo.

60 APPLIED LIFE SCIENCES↗

Grinding energy and physical properties of chopped and hammer-milled barley, wheat, oat, and canola straws

In the present study, specific energy for grinding and physical properties of wheat, canola, oat and barley straw grinds were investigated. The initial moisture content of the straw was about 0.13–0.15 (fraction total mass basis). Particle size reduction experiments were conducted in two stages: (1) a chopper without a screen, and (2) a hammer mill using three screen sizes (19.05, 25.4, and 31.75 mm). The lowest grinding energy (1.96 and 2.91 kWh t-1) was recorded for canola straw using a chopper and hammer mill with 19.05-mm screen size, whereas the highest (3.15 and 8.05 kWh t-1) was recorded for barley and oat straws. The physical properties (geometric mean particle diameter, bulk, tapped and particle density, and porosity) of the chopped and hammer-milled wheat, barley, canola, and oat straw grinds measured were in the range of 0.98–4.22 mm, 36–80 kg m-3, 49–119 kg m-3, 600–1220 kg m-3, and 0.9–0.96, respectively. The average mean particle diameter was highest for the chopped wheat straw (4.22-mm) and lowest for the canola grind (0.98-mm). The canola grinds produced using the hammer mill (19.05-mm screen size) had the highest bulk and tapped density of about 80 and 119 kg m-3; whereas, the wheat and oat grinds had the lowest of about 58 and 88–90 kg m-3. The results indicate that the bulk and tapped densities are inversely proportional to the particle size of the grinds. The flow properties of the grinds calculated are better for chopped straws compared to hammer milled using smaller screen size (19.05 mm).

09 BIOMASS FUELS↗

Comparison of Target Registration Errors for Multiple Image-Guided Techniques in Accelerated Partial Breast Irradiation

Purpose: External beam accelerated partial breast irradiation requires accurate localization of the target volume for each treatment fraction. Using the concept of target registration error (TRE), the performance of several methods of target localization was compared. Methods and Materials: Twelve patients who underwent external beam accelerated partial breast irradiation were included in this study. TRE was quantified for four methods of image guidance: standard laser-based setup, kilovoltage imaging of the chest wall, kilovoltage imaging of surgically implanted clips, and three-dimensional surface imaging of the breast. The use of a reference surface created from a free-breathing computed tomography scan and a reference surface directly captured with three-dimensional video imaging were compared. The effects of respiratory motion were also considered, and gating was used for 8 of 12 patients. Results: The median value of the TRE for the laser, chest wall, and clip alignment was 7.1 mm (n = 94), 5.4 mm (n = 81), and 2.4 mm (n = 93), respectively. The median TRE for gated surface imaging based on the first fraction reference surface was 3.2 mm (n = 49), and the TRE for gated surface imaging using the computed tomography-based reference surface was 4.9 mm (n = 56). The TRE for nongated surface imaging using the first fraction reference surface was 6.2 mm (n = 25). Conclusions: The TRE of surface imaging using a reference surface directly captured with three-dimensional video and the TRE for clip-based setup were within 1 mm. Gated capture is important for surface imaging to reduce the effects of respiratory motion in accelerated partial breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Guidance Based on Prostate Position for Prostate Cancer Proton Therapy

Purpose: To determine the target coverage for proton therapy with and without image guidance and daily prebeam reorientation. Methods and Materials: A total of 207 prostate positions were analyzed for 9 prostate cancer patients treated using our low-risk prostate proton therapy protocol (University of Florida Proton Therapy Institute 001). The planning target volume was defined as the prostate plus a 5-mm axial and 8-mm superoinferior extension. The prostate was repositioned using 5- and 10-mm shifts (anteriorly, inferiorly, posteriorly, and superiorly) and for Points A-D using a combination of 10-mm multidimensional movements (anteriorly or inferiorly; posteriorly or superiorly; and left or right). The beams were then realigned using the new prostate position. The prescription dose was 78 Gray equivalent (GE) to 95% of the planning target volume. Results: For small movements in the anterior, inferior, and posterior directions within the planning target volume ({<=}5 mm), treatment realignment demonstrated small, but significant, improvements in the clinical target volume (CTV) coverage to the prescribed dose (78 GE). The anterior and posterior shifts also significantly increased the minimal CTV dose ({delta} +1.59 GE). For prostate 10-mm movements in the inferior, posterior, and superior directions, the beam realignment produced larger and significant improvements for both the CTV V{sub 78} ({delta} +6.4%) and the CTV minimal dose ({delta} +8.22 GE). For the compounded 10-mm multidimensional shifts, realignment significantly improved the CTV V{sub 78} ({delta} +11.8%) and CTV minimal dose ({delta} +23.6 GE). After realignment, the CTV minimal dose was >76.6 GE (>98%) for all points (A-D). Conclusion: Proton beam realignment after target shift will enhance CTV coverage for different prostate positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗