Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

On the mobility and contact resistance evaluation for transistors based on MoS{sub 2} or two-dimensional semiconducting atomic crystals

Contact resistance (R{sub c}) can substantially obscure the extracted mobility based on standard transconductance or two-point conductance measurements of field-effect devices especially for low density of states materials such as MoS{sub 2} or similar atomic crystals. Currently, there exists a pressing need for a routine technique that can decouple mobility extraction from R{sub c}. By combining experiments and analysis, we show that the Y-function method offers a robust route for evaluating the low-field mobility, threshold voltage and R{sub c} even when the contact is a Schottky-barrier as is common in two-dimensional transistors. In addition, an independent modified transfer length method evaluation corroborates the Y-function analysis.

36 MATERIALS SCIENCE↗

Measurement of crack length in width tapered beam experiments

The width tapered beam method for measuring fracture toughness has been contemplated for use in measuring the adhesion of photovoltaic materials, is promoted by it being a viable method for use directly on modules rather than to engineered test specimens. However, precise determination of crack length is often difficult as failure often involves tendril formation, cavitation voids, and other plastic deformation at the crack front in addition to obfuscation by opaque materials. Because fracture energy varies as the square of crack length, imprecise crack tip length results in large measurement uncertainties. In this work, we develop a method to estimate the crack tip length using the relationship between the applied force and the displacement of the load frame. The crack tip is determined for every data point and can be defined from a calibration curve related to the amount of energy put into the beam, or from a theoretically idealized estimation. Once a calibration curve is set up and the equations programmed, the fracture energy as a function of position on the newly formed crack interface can be accurately estimated. The test additionally provides much easier analysis and insight into the joint failure through more precise knowledge of fracture toughness at each de-bonded area.

42 ENGINEERING↗

Effect of current injection into thin-film Josephson junctions

New thin-film Josephson junctions have recently been tested in which the current injected into one of the junction banks governs Josephson phenomena. One thus can continuously manage the phase distribution at the junction by changing the injected current. Our method of calculating the distribution of injected currents is also proposed for a half-infinite thin-film strip with source-sink points at arbitrary positions at the film edges. The strip width W is assumed small relative to Λ=2λ 2 /d;λ is the bulk London penetration depth of the film material and d is the film thickness.

42 ENGINEERING↗

SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct determination of mode-projected electron-phonon coupling in the time domain

Ultrafast spectroscopies have become an important tool for elucidating the microscopic description and dynamical properties of quantum materials. In particular, by tracking the dynamics of nonthermal electrons, a material’s dominant scattering processes can be revealed. In this paper, we present a method for extracting the electron-phonon coupling strength in the time domain, using time- and angle-resolved photoemission spectroscopy (TR-ARPES). This method is demonstrated in graphite, where we investigate the dynamics of photoinjected electrons at the $\overline{K}$ point, detecting quantized energy-loss processes that correspond to the emission of strongly coupled optical phonons. We show that the observed characteristic time scale for spectral weight transfer mediated by phonon-scattering processes allows for the direct quantitative extraction of electron-phonon matrix elements for specific modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated Process Model Utilization and Development for Inertial Fusion Energy

This CRADA between LLNS and Longview Fusion Energy Systems utilized a modernized LLNL Integrated Process Model (IPM) to assess technoeconomic viability and power plant configurations for Inertial Fusion Energy (IFE). During the collaboration period, a streamlined IPM model was produced by LLNL, which consolidated a combination of 3 models under one file. Additionally, obsolete parameters were removed and parameters available for trade space analysis were organized in a user-friendly fashion on the front interface. Gain scaling curves were discussed and analyzed in the framework of the IPM. Additional updates were made to account for cost scaling to today's dollars using an average inflation rate. Heat transfer material costing was updated using a ground up approach with public vendor data. Further levelized cost of electricity (LCOE) methods and models were discussed and reviewed for applicability to the IPM. Prior published literature on optical scaling was also discussed. Moreover, as part of this CRADA, the Participant developed a fusion technology development roadmap and point designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated Process Model Utilization and Development for Inertial Fusion Energy

This CRADA between LLNS and Longview Fusion Energy Systems utilized a modernized LLNL Integrated Process Model (IPM) to assess technoeconomic viability and power plant configurations for Inertial Fusion Energy (IFE). During the collaboration period, a streamlined IPM model was produced by LLNL, which consolidated a combination of 3 models under one file. Additionally, obsolete parameters were removed and parameters available for trade space analysis were organized in a user-friendly fashion on the front interface. Gain scaling curves were discussed and analyzed in the framework of the IPM. Additional updates were made to account for cost scaling to today's dollars using an average inflation rate. Heat transfer material costing was updated using a ground up approach with public vendor data. Further levelized cost of electricity (LCOE) methods and models were discussed and reviewed for applicability to the IPM. Prior published literature on optical scaling was also discussed. Moreover, as part of this CRADA, the Participant developed a fusion technology development roadmap and point designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of CT-derived Ventilation Maps with Deposition Patterns of Inhaled Microspheres in Rats

Purpose: Computer models for inhalation toxicology and drug-aerosol delivery studies rely on ventilation pattern inputs for predictions of particle deposition and vapor uptake. However, changes in lung mechanics due to disease can impact airflow dynamics and model results. It has been demonstrated that non-invasive, in vivo, 4DCT imaging (3D imaging at multiple time points in the breathing cycle) can be used to map heterogeneities in ventilation patterns under healthy and disease conditions. The purpose of this study was to validate ventilation patterns measured from CT imaging by exposing the same rats to an aerosol of fluorescent microspheres (FMS) and examining particle deposition patterns using cryomicrotome imaging. Materials and Methods: Six male Sprague-Dawley rats were intratracheally instilled with elastase to a single lobe to induce a heterogeneous disease. After four weeks, rats were imaged over the breathing cycle by CT then immediately exposed to an aerosol of ~1µm FMS for ~5 minutes. After the exposure, the lungs were excised and prepared for cryomicrotome imaging, where a 3D image of FMS deposition was acquired using serial sectioning. Cryomicrotome images were spatially registered to match the live CT images to facilitate direct quantitative comparisons of FMS signal intensity with the CT-based ventilation maps. Results: Comparisons of fractional ventilation in contiguous, non-overlapping, 3D regions between CT-based ventilation maps and FMS images showed strong correlations in fractional ventilation (r=0.888, p<0.0001). Conclusion: We conclude that ventilation maps derived from CT imaging are predictive of the 1µm aerosol deposition used in ventilation-perfusion heterogeneity inhalation studies.

Jacob, Rick E.↗

Neutron multiplicity analysis tool

I describe the capabilities of the EXCOM (EXcel based COincidence and Multiplicity) calculation tool which is used to analyze experimental data or simulated neutron multiplicity data. The input to the program is the count-rate data (including the multiplicity distribution) for a measurement, the isotopic composition of the sample and relevant dates. The program carries out deadtime correction and background subtraction and then performs a number of analyses. These are: passive calibration curve, known alpha and multiplicity analysis. The latter is done with both the point model and with the weighted point model. In the current application EXCOM carries out the rapid analysis of Monte Carlo calculated quantities and allows the user to determine the magnitude of sample perturbations that lead to systematic errors. Neutron multiplicity counting is an assay method used in the analysis of plutonium for safeguards applications. It is widely used in nuclear material accountancy by international (IAEA) and national inspectors. The method uses the measurement of the correlations in a pulse train to extract information on the spontaneous fission rate in the presence of neutrons from ({alpha},n) reactions and induced fission. The measurement is relatively simple to perform and gives results very quickly ({le} 1 hour). By contrast, destructive analysis techniques are extremely costly and time consuming (several days). By improving the achievable accuracy of neutron multiplicity counting, a nondestructive analysis technique, it could be possible to reduce the use of destructive analysis measurements required in safeguards applications. The accuracy of a neutron multiplicity measurement can be affected by a number of variables such as density, isotopic composition, chemical composition and moisture in the material. In order to determine the magnitude of these effects on the measured plutonium mass a calculational tool, EXCOM, has been produced using VBA within Excel. This program was developed to help speed the analysis of Monte Carlo neutron transport simulation (MCNP) data, and only requires the count-rate data to calculate the mass of material using INCC's analysis methods instead of the full neutron multiplicity distribution required to run analysis in INCC. This paper describes what is implemented within EXCOM, including the methods used, how the program corrects for deadtime, and how uncertainty is calculated. This paper also describes how to use EXCOM within Excel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis of Layered Gold Tellurides AuSbTe and Au 2 Te 3 and Their Semiconducting and Metallic Behavior

Previous studies on natural samples of pampaloite (AuSbTe) revealed the crystal structure of a potentially cleavable and/or exfoliable material, while studies on natural and synthetic montbrayite (Sb-containing Au 2 Te 3 ) claimed various chemical compositions for this low-symmetry compound. Few investigations of synthetic samples have been reported for both materials, leaving much of their chemical, thermal, and electronic characteristics unknown. Here, in this study, we investigate the stability, electronic properties, and synthesis of the gold antimony tellurides AuSbTe and Au 1.9 Sb 0.46 Te 2.64 (montbrayite). Differential thermal analysis and in situ powder X-ray diffraction revealed that AuSbTe is incongruently melting, while Au 1.9 Sb 0.46 Te 2.64 is congruently melting. Calculations of the band structures and four-point resistivity measurements showed that AuSbTe is a semiconductor and Au 1.9 Sb 0.46 Te 2.64 a metal. Various synthesis attempts confirmed the limited stable chemical composition of Au 1.9 Sb 0.46 Te 2.64 , identified successful methods to synthesize both compounds, and highlighted the challenges associated with single-crystal synthesis of AuSbTe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

High-throughput combinatorial approach expedites the synthesis of a lead-free relaxor ferroelectric system

Developing novel lead-free ferroelectric materials is crucial for next-generation microelectronic technologies that are energy efficient and environment friendly. However, materials discovery and property optimization are typically time-consuming due to the limited throughput of traditional synthesis methods. In this work, we use a high-throughput combinatorial synthesis approach to fabricate lead-free ferroelectric superlattices and solid solutions of (Ba 0.7 Ca 0.3 )TiO 3 (BCT) and Ba(Zr 0.2 Ti 0.8 )O 3 (BZT) phases with continuous variation of composition and layer thickness. High-resolution x-ray diffraction (XRD) and analytical scanning transmission electron microscopy (STEM) demonstrate high film quality and well-controlled compositional gradients. Ferroelectric and dielectric property measurements identify the “optimal property point” achieved at the composition of 48BZT–52BCT. Displacement vector maps reveal that ferroelectric domain sizes are tunable by varying {BCT–BZT} N superlattice geometry. This high-throughput synthesis approach can be applied to many other material systems to expedite new materials discovery and properties optimization, allowing for the exploration of a large area of phase space within a single growth.

36 MATERIALS SCIENCE↗

Oxygen potential measurement and point defect chemistry of UO{sub 2}

Many studies on the oxygen potential of UO{sub 2} have been carried out so far. However, the oxygen potential data for UO{sub 2} near the stoichiometric composition in the high temperature region (1673-1873 K) are limited. Recently, Kato's group had investigated oxygen potential of (U, Pu)O{sub 2} as functions of Pu content, oxygen-to-metal (O/M) ratio and temperature. They evaluated the data based on defect chemistry. The UO{sub 2} data are fundamental to evaluate oxygen potential in UO{sub 2}-PuO{sub 2} solid solution. In this work, the oxygen potential data of UO{sub 2+x} were extended to the high temperature range of 1673-1873 K by gas equilibrium method. The measured data were analyzed based on a defect chemistry model. Kroeger-Vink's diagram were obtained in UO{sub 2+x}. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of the adhesion-force lever-arm “a” on the Rock ‘n’ Roll resuspension model and how to compute it from contact mechanics

The paper proposes a methodology to fill a gap in the context of mechanistic particle resuspension models related to the adhesion and lift force lever arms ( a ): to date, only one experimental observation exists from a centrifuge experiment with a specific particle/surface pair which found r P / a = 100 and assumed that the contact points were symmetric with respect to the particle center. However, the Reeks and Hall’s (2001) model is highly sensitive to this parameter, which therefore cannot be used as-is for different particle diameters or materials. This paper proposes a methodology to compute the adhesion and lift force lever arms ( a A and a L , respectively) based on Atomic Force Microcopy (AFM) surface roughness measurements and contact mechanics arguments. In practice, a spherical, perfectly smooth particle is brought in contact (computationally) with the measured surface roughness and is then rotated by the point of contact to determine the two or more asperities over which the particle would sit on the surface. A method to compute the asperity radius of curvature is devised to compute the asperity deformation and the correct partitioning of the total deformation between the particle and the asperity is presented. For the glass surface under consideration, the asperity deformation was negligible, i.e., it was below the van der Waals radius, which is the limit of applicability of contact mechanics. The Reeks and Hall’s (2001) model is then extended to account for the joint probability of a A and a L . Significant differences in particle resuspended after a day in common atmospheric conditions are found between the approach that uses the lever-arm distributions or their mean values. Also, important differences are found when comparing the lever-arm distribution and r P / a = 100. Hence, one should be cautious of using r P / a = 100 for surface/particle pairs differing from those in the original study. Finally, limits of applicability of the theories used are presented together with considerations regarding how to extend the method to non-spherical particles and different materials.

42 ENGINEERING↗

Density Functional Theory of Structural and Electronic Properties of III-N Semiconductors

In this wok, we present the density functional theory (DFT) calculations of cubic III-N based semiconductors by using the full potential linear augmented plane-wave method plus local orbitals as implemented in the WIEN2k code. Our aim is to predict the pressure effect on structural and electronic properties of III-N binaries and ternaries. Results are given for structural properties (e.g., lattice constant, elastic constants, bulk modulus, and its pressure derivative) and electronic properties (e.g., band structure, density of states, band gaps and band widths) of GaAs, GaN, AlN, and InN binaries and GaAsN ternaries. The proposed model uses GGA exchange-correlation potential to determine band gaps of semiconductors at {Gamma}, L and X high symmetry points of Brillouin zone. The results are found in good agreement with available experimental data for structural and electronic properties of these semiconductors.

36 MATERIALS SCIENCE↗

Mechanical assembly of complex, 3D mesostructures from releasable multilayers of advanced materials

Capabilities for assembly of three-dimensional (3D) micro/nanostructures in advanced materials have important implications across a broad range of application areas, reaching nearly every class of microsystem technology. Approaches that rely on the controlled, compressive buckling of 2D precursors are promising because of their demonstrated compatibility with the most sophisticated planar technologies, where materials include inorganic semiconductors, polymers, metals, and various heterogeneous combinations, spanning length scales from submicrometer to centimeter dimensions. We introduce a set of fabrication techniques and design concepts that bypass certain constraints set by the underlying physics and geometrical properties of the assembly processes associated with the original versions of these methods. In particular, the use of releasable, multilayer 2D precursors provides access to complex 3D topologies, including dense architectures with nested layouts, controlled points of entanglement, and other previously unobtainable layouts. Furthermore, the simultaneous, coordinated assembly of additional structures can enhance the structural stability and drive the motion of extended features in these systems. The resulting 3D mesostructures, demonstrated in a diverse set of more than 40 different examples with feature sizes from micrometers to centimeters, offer unique possibilities in device design. In conclusion, a 3D spiral inductor for near-field communication represents an example where these ideas enable enhanced quality ( Q ) factors and broader working angles compared to those of conventional 2D counterparts.

36 MATERIALS SCIENCE↗

The electronic properties and lattice dynamics of (Na{sub 0.5}Bi{sub 0.5})TiO{sub 3}: From cubic to tetragonal and rhombohedral phases

The structural, electronic and dynamical properties of the cubic, tetragonal and rhombohedral phases of a lead-free ferroelectrics, (Na{sub 0.5}Bi{sub 0.5})TiO{sub 3} (NBT), have been studied with a density functional formalism. The direct band gap is determined to be 2∼3 eV for three phases, suggesting them to be good optical material. The equilibrium structures were given, and the importance of Bi atom in the low-symmetry ferroelectric phases were investigated with the electron localization functions analysis. The vibration modes at the Γ point were calculated to provide a basis for analyzing the Raman and IR spectra. Soft modes were found in both the cubic and the tetragonal phases, providing a clue in understanding the ferroelectric phase transition in NBT.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stereotactic Body Radiotherapy Versus Surgery for Medically Operable Stage I Non-Small-Cell Lung Cancer: A Markov Model-Based Decision Analysis

Purpose: To compare the quality-adjusted life expectancy and overall survival in patients with Stage I non-small-cell lung cancer (NSCLC) treated with either stereotactic body radiation therapy (SBRT) or surgery. Methods and Materials: We constructed a Markov model to describe health states after either SBRT or lobectomy for Stage I NSCLC for a 5-year time frame. We report various treatment strategy survival outcomes stratified by age, sex, and pack-year history of smoking, and compared these with an external outcome prediction tool (Adjuvant{exclamation_point} Online). Results: Overall survival, cancer-specific survival, and other causes of death as predicted by our model correlated closely with those predicted by the external prediction tool. Overall survival at 5 years as predicted by baseline analysis of our model is in favor of surgery, with a benefit ranging from 2.2% to 3.0% for all cohorts. Mean quality-adjusted life expectancy ranged from 3.28 to 3.78 years after surgery and from 3.35 to 3.87 years for SBRT. The utility threshold for preferring SBRT over surgery was 0.90. Outcomes were sensitive to quality of life, the proportion of local and regional recurrences treated with standard vs. palliative treatments, and the surgery- and SBRT-related mortalities. Conclusions: The role of SBRT in the medically operable patient is yet to be defined. Our model indicates that SBRT may offer comparable overall survival and quality-adjusted life expectancy as compared with surgical resection. Well-powered prospective studies comparing surgery vs. SBRT in early-stage lung cancer are warranted to further investigate the relative survival, quality of life, and cost characteristics of both treatment paradigms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗