Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Automated Assembly Progress Monitoring in Modular Construction Factories Using Computer Vision-Based Instance Segmentation

Modular construction has recently gained interest as a transformative construction method. In this method, a large portion of the construction is performed inside factories, where processes are fast-paced and interdependent; therefore, any deviation from the schedule can delay the production. Such deviations are frequent in modular factories due to the labor-intensive nature of the tasks. This propagation of delays can be mitigated by continuously monitoring each process; however, current manual monitoring methods are laborious, and recently proposed contact sensor-based methods are intrusive to the work. In addition, recent computer vision-based monitoring methods inside factories are limited to detection algorithms that fail to provide the pixel-level accuracy required for assembly progress monitoring in highly occluded factory scenes, and they require a large number of manual annotations. Therefore, this paper proposes a method to monitor the installation of subassemblies in modular construction factories using mask R-CNN instance segmentation and improves the data efficiency of the model using a copy-paste augmentation method. This method was validated on the CCTV videos captured from a modular construction factory in the US, resulting in a 9% mAP improvement in segmentation.

computer vision↗

Memory access statistics monitoring

Systems, apparatuses, and methods related to memory access statistics monitoring are described. A host is configured to map pages of memory for applications to a number of memory devices coupled thereto. A first memory device comprises a monitoring component configured to monitor access statistics of pages of memory mapped to the first memory device. A second memory device does not include a monitoring component capable of monitoring access statistics of pages of memory mapped thereto. The host is configured to map a portion of pages of memory for an application to the first memory device in order to obtain access statistics corresponding to the portion of pages of memory upon execution of the application despite there being space available on the second memory device and adjust mappings of the pages of memory for the application based on the obtained access statistics corresponding to the portion of pages.

Roberts, David A.↗

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES↗

An optimization approach to design monitoring schemes for CO 2 leakage detection

This paper demonstrates an approach to identify optimal monitoring designs that minimize the time to first detection of CO 2 leakage from a subsurface storage formation. This research is part of the National Risk Assessment Partnership (NRAP), a DOE project tasked with conducting risk and uncertainty analysis in the areas of reservoir performance, natural leakage pathways, wellbore integrity, groundwater protection, monitoring, and systems level modeling. Our approach applies a simulated annealing algorithm that searches the solution space by iteratively mutating potential monitoring designs. An example application is provided to demonstrate the effectiveness and efficiency of this method compared to an exhaustive search of the entire solution space. We took into account uncertainty by evaluating the performance of potential monitoring designs across a set of simulated leakage realization. A flexible two-tiered signature was implemented to infer that CO 2 leakage had occurred. This approach was ~50 times faster than an exhaustive search. A user-friendly tool, MDLD, is being developed for use on personal computers to make this method available to stakeholders, regulators, and researchers.

03 NATURAL GAS↗

Influence of background sources and topographic resolution in the Weather Research and Forecasting Model on xenon plume characteristics at monitoring stations

For many atmospheric monitoring applications, networks of measurement sites—such as the radionuclide stations of the International Monitoring System—can be sparse. With measurement locations potentially hundreds to thousands of kilometers from a release it is important to quantify the effects of physical processes on transport and dispersion of plumes between source and measurement locations. This study addresses the effects of background sources and topography resolution near the release location of radionuclides. We use the Weather Research and Forecasting (WRF) model with inline chemistry to investigate (1) how an additional, time-varying source of 133 Xe, such as an operational medical isotope production facility, contributes to activity concentration measurements at monitoring sites, and (2) how complex topography influences on atmospheric conditions near emission sources impact plume concentrations at varying distances from the source. Two 133 Xe emission sources, including (1) a high flux rate of short duration representing an explosive event, and (2) a variable and continuous background source, are simulated. The continuous background source contributes significantly to total 133 Xe concentrations at several monitoring stations. Further, a WRF simulation at 9 km horizontal resolution is compared with a nested grid simulation, where the innermost domain has a resolution of 1 km. Increased topographic resolution leads to an improved representation of plume responses to local winds, with topographic influences greatest at locations closest to the sources. Differences between the two domain resolutions decrease at greater distances from the sources, as plumes have time to spread and mix and are influenced by synoptic scale circulation patterns that are represented similarly in both simulations.

54 ENVIRONMENTAL SCIENCES↗

Fission Product Monitoring of TRISO Coated Fuel For The Advanced Gas Reactor -1 Experiment

The US Department of Energy has embarked on a series of tests of TRISO-coated particle reactor fuel intended for use in the Very High Temperature Reactor (VHTR) as part of the Advanced Gas Reactor (AGR) program. The AGR-1 TRISO fuel experiment, currently underway, is the first in a series of eight fuel tests planned for irradiation in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). The AGR-1 experiment reached a peak compact averaged burn up of 9% FIMA with no known TRISO fuel particle failures in March 2008. The burnup goal for the majority of the fuel compacts is to have a compact averaged burnup greater than 18% FIMA and a minimum compact averaged burnup of 14% FIMA. At the INL the TRISO fuel in the AGR-1 experiment is closely monitored while it is being irradiated in the ATR. The effluent monitoring system used for the AGR-1 fuel is the Fission Product Monitoring System (FPMS). The FPMS is a valuable tool that provides near real-time data indicative of the AGR-1 test fuel performance and incorporates both high-purity germanium (HPGe) gamma-ray spectrometers and sodium iodide [NaI(Tl)] scintillation detector-based gross radiation monitors. To quantify the fuel performance, release-to-birth ratios (R/B’s) of radioactive fission gases are computed. The gamma-ray spectra acquired by the AGR-1 FPMS are analyzed and used to determine the released activities of specific fission gases, while a dedicated detector provides near-real time count rate information. Isotopic build up and depletion calculations provide the associated isotopic birth rates. This paper highlights the features of the FPMS, encompassing the equipment, methods and measures that enable the calculation of the release-to-birth ratios. Some preliminary results from the AGR-1 experiment are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Satellite-based snow identification and its impact on monitoring photovoltaic systems

Earth observation allows the separation of snow cover and cloudiness using multispectral measurements. Several satellite-based snow monitoring services are available, ranging from regional to world-wide scales. Using these data enables photovoltaic (PV) plant management to differentiate between failures due to snow coverage on a PV system and other error sources. Additionally, yield estimates for solar siting are improved. This paper presents a validation study from January to April 2006 comparing satellite-based datasets with ground measurements from German and Swiss meteorological stations. A false alarm rate, an error due to irradiance underestimation, the availability of daily data, and the classification accuracy are introduced as quality metrics. Compared to Switzerland, generally a higher accuracy is found in all datasets for Southern Germany. The most significant difference among the datasets is found in the error pattern shifting from too much snow (which results in an error due to underestimation of irradiance) to too little snow detection, causing a false alarm in PV monitoring. Overall, the data records of the Land Surface Analysis Satellite Application Facility (LSA SAF), the German Aerospace Center (DLR) and the Interactive Multisensor Snow and Ice Mapping System (IMS) are found to be most suitable for solar energy purposes. The IMS dataset has a low false alarm rate (4%) and a good data availability (100%) making it a good choice for power plant monitoring, but the error due to underestimation relevant in site auditing is large with 59%. If a cumulative snow cover algorithm is applied to achieve information every day as needed both for power plant monitoring and site auditing, both the DLR and the LSA SAF datasets are comparable with classification accuracies of 70%, false alarm rates of 37% and 34%, respectively, and errors due to irradiance underestimation in 26% and 27% of all coincidences. (author)

14 SOLAR ENERGY↗

Real-Time Monitoring of Gas-Phase and Dissolved CO 2 Using a Mixed-Matrix Composite Integrated Fiber Optic Sensor for Carbon Storage Application

Novel chemical sensors that improve detection and quantification of CO 2 are critical to ensuring safe and cost-effective monitoring of carbon storage sites. Fiber optic (FO) based chemical sensor systems are promising field-deployable systems for real-time monitoring of CO 2 in geological formations for long-range distributed sensing. Here, a mixed-matrix composite integrated FO sensor system was developed with a purely optical readout that reliably operates as a detector for gas-phase and dissolved CO 2 . A mixed-matrix composite sensor coating consisting of plasmonic nanocrystals and hydrophobic zeolite embedded in a polymer matrix was integrated on the FO sensor. The mixed-matrix composite FO sensor showed excellent reversibility/stability in a high humidity environment and sensitivity to gas-phase CO 2 over a large concentration range. This remarkable sensing performance was enabled by using plasmonic nanocrystals to significantly enhance the sensitivity and a hydrophobic zeolite to effectively mitigate interference from water vapor. The sensor exhibited the ability to sense CO 2 in the presence of other geologically relevant gases, which is of importance for applications in geological formations. A prototype FO sensor configuration which possesses a robust sensing capability for monitoring dissolved CO 2 in natural water was demonstrated. Reproducibility was confirmed over many cycles, both in a laboratory setting and in the field. More importantly, we demonstrated on-line monitoring capabilities with a wireless telemetry system, which transferred the data from the field to a website. The combination of outstanding CO 2 sensing properties and facile coating processability makes this mixed-matrix composite FO sensor a good candidate suitable for practical carbon storage applications.

54 ENVIRONMENTAL SCIENCES↗

Field-Based Detection and Mnitoring of Uranium in Contaminated Groundwater using two Immunosensors

Field-based monitoring of environmental contaminants has long been a need for environmental scientists. Described herein are two kinetic exclusion-based immunosensors, a field portable sensor (FPS) and an inline senor, that were deployed at the Integrated Field Research Challenge Site of the U.S. Department of Energy in Rifle, CO. Both sensors utilized a monoclonal antibody that binds to a U(VI)-dicarboxyphenanthroline complex (DCP) in a kinetic exclusion immunoassay format. These sensors were able to monitor changes of uranium in groundwater samples from ~1 μM to below the regulated drinking water limit of 126 nM (30 ppb). The FPS is a battery-operated sensor platform that can determine the uranium level in a single sample in 5-10 min, if the instrument has been previously calibrated with standards. The average minimum detection level (MDL) in this assay was 0.33 nM (79 ppt), and the MDL in the sample (based on a 1:200-1:400 dilution) was 66-132 nM (15.7-31.4 ppb). The inline sensor, while requiring a grounded power source, has the ability to autonomously analyze multiple samples in a single experiment. The average MDL in this assay was 0.12 nM (29 ppt), and the MDL in the samples (based on 1:200 or 1:400 dilutions) was 24-48 nM (5.7-11.4 ppb). Both sensor platforms showed an acceptable level of agreement (r 2 = 0.94 and 0.76, for the inline and FPS, respectively) with conventional methods for uranium quantification.

Melton, Scott J↗

A beam intensity monitor for the evaluation beamline for soft x-ray optical elements

Evaluation Beamline for Soft X-Ray Optical Elements (BL-11) at the SR Center of Ritsumeikan University has been operated to measure the wavelength and angular characteristics of soft x-ray optical components in a wavelength range of 0.65-25 nm using a reflecto-diffractometer (RD). The beam intensity monitor that has been equipped in BL-11 has observed the signal of the zero-th order light. For the purpose of more accurate evaluation of the performance of optical components, a new beam intensity monitor to measure the intensity of the first order light from the monochromator in BL-11 has been developed and installed in just front of RD. The strong positive correlation between the signal of the beam monitor and a detector equipped in the RD is shown. It is successful that the beam intensity of the first order light can be monitored in real time.

43 PARTICLE ACCELERATORS↗

Compact integrated X-ray intensity and beam position monitor based on rare gas scintillation

We have created and tested a compact integrated X-ray beam intensity and position monitor using Ar-gas scintillation. The light generated inside the device's cavity is detected by diametrically opposed PIN diodes located above and below the beam. The intensity is derived from the sum of the top and bottom signals, while the beam position is calculated from the difference-over-sum of the two signals. The device was tested at Cornell High Energy Synchrotron Source with both 17 keV and 59 keV x-rays. For intensity monitoring, the Ar-scintillation monitor performance is comparable to standard ion chambers in terms of precision. As an X-ray beam position monitor the new device response is linear with vertical beam position over a 2 mm span with a precision of 2 {mu}m.

43 PARTICLE ACCELERATORS↗

MWm-array sensors for in situ monitoring of high-temperature components in power plants

Utilization of America's substantial coal reserves for energy production has become a national priority. Advanced coal-fired power plants offer an environmentally friendly means to achieve that goal. These power plants, such as ultrasupercritical power plants, will provide high thermal efficiency along with greatly reduced emissions of CO and other pollutants. Life cycle costs for the advanced coal-fired plants can be reduced by enhanced observability in support of condition-based maintenance. The enhanced observability can be achieved by using networks of condition-monitoring sensors that would provide component-level material condition information and through-wall temperature monitoring. This would reduce uncertainties in knowledge of material condition, at the level of individual components, and improve capability to predict remaining life of critical components. One approach being developed under the U.S. Department of Energy Small Business Innovation Research Program is to develop and implement high-temperature versions of the meandering winding magnetometer (HT-MWM) for temperatures up to 1000{sup o}C. These patented sensors, coupled with multivariate inverse methods, would provide superior performance for in situ material condition monitoring (material degradation, flaw detection, stress relaxation, and/or creep monitoring) and through-wall temperature measurement. Networks of HT-MWMs will generate material condition information to be used by adaptive life-management algorithms for remaining life prediction and decision support.

20 FOSSIL-FUELED POWER PLANTS↗

Online Junction Temperature Monitoring Using Intelligent Gate Drive for SiC Power Devices

Junction temperature is a prime design/operation parameter, as well as, a main indicator of device's health condition for power electronics converters. Compared to its silicon (Si) counterparts, it is more critical for silicon carbide (SiC) devices due to the reliability concern determined by the immaturity of new material and packaging. This paper presents a practical implementation using an intelligent gate drive for online junction temperature monitoring of SiC devices based on turn-off delay time as the thermo-sensitive electrical parameter. First, the sensitivity of turn-off delay time on the junction temperature for fast switching SiC devices is analyzed. A gate impedance regulation assist circuit is proposed to enhance the sensitivity by a factor of 60 and approach 736 ps/°C tested in the case study with little penalty on the power conversion performance. Next, an online monitoring unit based on gate assist circuits is developed to monitor the turn-off delay time in real time with the resolution less than 104 ps. As a result, the micro-controller is capable of “reading” junction temperature during the converter operation. Finally, a SiC-based half-bridge inverter is constructed with an intelligent gate drive consisting of the gate impedance regulation circuit and online turn-off delay time monitoring unit. Experimental results demonstrate the feasibility and accuracy of the proposed approach.

42 ENGINEERING↗

SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations

Purpose: Development of strategies to monitor range uncertainties is necessary to improve treatment planning in Charged Particle Therapy (CPT) and fully exploit the advantages of ion beams. Our group developed (within the framework of the INSIDE project funded by the Italian research ministry) and is currently building a compact detector Dose Profiler (DP) able to backtrack charged secondary particles produced in the patient during the irradiation. Furthermore we are studying monitoring strategy exploiting charged secondary emission profiles to control the range of the ion beam. Methods: This contribution reports on the DP detector design and construction status. The detector consists of a charged secondary tracker composed of scintillating fiber layers and a LYSO calorimeter for particles energy measurement.The detector layout has been optimized using the FLUKA Monte Carlo (MC) simulation software. The simulation of a 220 MeV Carbon beam impinging on a PMMA target has been performed to study the detector response, exploiting previous secondary radiation measurements performed by our group. The emission profile of charged secondary particles was reconstructed backtracking the particles to their generation point to benchmark the DP performances. Results: The DP construction status, including the technological details will be presented. The feasibility of range monitoring with DP will be demonstrated by means of MC studies. The correlation of the charged secondary particles emission shape with the position of the Bragg peak (BP) will be shown, as well as the spatial resolution achievable on the BP position estimation (less than 3 mm) in the clinical like conditions. Conclusion: The simulation studies supported the feasibility of an accurate range monitoring technique exploiting the use of charged secondary fragments emitted during the particle therapy treatment. The DP experimental tests are foreseen in 2016, at CNAO particle therapy center in Pavia.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration

Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.

Distributed Strain Sensing↗

Developing a monitoring and verification plan with reference to the Australian Otway CO2 pilot project

The Australian Cooperative Research Centre for Greenhouse Gas Technologies (CO2CRC) is currently injecting 100,000 tons of CO{sub 2} in a large-scale test of storage technology in a pilot project in southeastern Australia called the CO2CRC Otway Project. The Otway Basin, with its natural CO{sub 2} accumulations and many depleted gas fields, offers an appropriate site for such a pilot project. An 80% CO{sub 2} stream is produced from a well (Buttress) near the depleted gas reservoir (Naylor) used for storage (Figure 1). The goal of this project is to demonstrate that CO{sub 2} can be safely transported, stored underground, and its behavior tracked and monitored. The monitoring and verification framework has been developed to monitor for the presence and behavior of CO{sub 2} in the subsurface reservoir, near surface, and atmosphere. This monitoring framework addresses areas, identified by a rigorous risk assessment, to verify conformance to clearly identifiable performance criteria. These criteria have been agreed with the regulatory authorities to manage the project through all phases addressing responsibilities, liabilities, and to assure the public of safe storage.

54 ENVIRONMENTAL SCIENCES↗

Spectroscopic Monitoring of Spent Nuclear Fuel Reprocessing Streams: An Evaluation of Spent Fuel Solutions via Raman, Visible, and Near-Infrared Spectroscopy

The potential of using optical spectroscopic techniques, such as Raman and Visible/Near Infrared (Vis/NIR), for on-line process control and special nuclear materials accountability applications at a spent nuclear fuel reprocessing facility was evaluated. Availability of on-line real-time techniques that directly measure process concentrations of nuclear materials will enhance performance and proliferation resistance of the solvent extraction processes. Further, on-line monitoring of radiochemical streams will also improve reprocessing plant operation and safety. This report reviews current state of development of the spectroscopic on-line monitoring techniques for such solutions. To further examine applicability of optical spectroscopy for monitoring reprocessing solutions, segments of a spent nuclear fuel, with approximate burn-up values of 70 MWd/kgM, were dissolved in concentrated nitric acid and adjusted to varying final concentrations of HNO3. The resulting spent fuel solutions were batch-contacted with tributyl phosphate/dodecane organic solvent. The feed and equilibrium aqueous and loaded organic solutions were subjected to optical measurements. The obtained spectra showed the presence of the quantifiable Raman bands due to NO3- and UO22+ and Vis/NIR bands due to multiple species of Pu(IV), Pu(VI), Np(V), the Np(V)-U(VI) cation-cation complex, and Nd(III) in fuel solutions, justifying spectroscopic techniques as a promising methodology for monitoring spent fuel processing solutions in real-time. Quantitative evaluation of the fuel solution was performed based on spectroscopic measurements and compared to ICP-MS analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗