At least 1,027 records · Page 57

Probabalistic Risk Analysis and Thermal Margin Process for an Inflatable Aeroshell

Uncertainties always exist in atmospheric entry aeroheating environments and the thermal response of thermal protection system (TPS) material. These uncertainties are mitigated in the design by ap-plying margin and factors of safety to the TPS. Entry vehicle TPS is often conservatively over-sized for the heat loads that are experienced along the entry trajectory by stacking worst-case scenarios together. Additionally, the current TPS design and margin process used by NASA offers very little insight into the risk of over-temperature during flight and the reliability of the heat shield performance [1,3]. A probabilistic margin process can be used to calculate the amount of TPS margin necessary to survive a given entry heat load at a specified level of risk [2,3,4]. The vehicle’s initial entry state (entry velocity, flight path angle, and entry mass) determines the expected atmospheric entry environmental conditions and resulting heat load that the entry vehicle will experience. If there is flexibility in the entry state, then this process can be used to select an appropriate combination of entry state parameters and TPS size to target a desired reentry reliability. This probabilistic margin process allows engineers to make informed aeroshell design, entry-trajectory design, and TPS performance risk trades while preventing excessive TPS margin from being applied. The probabilistic TPS margin process has been performed to determine TPS thickness and entry heating constraints given an acceptable risk level for the Low Earth Orbit Flight Experiment of an Inflatable Decelerator (LOFTID) flight project. The process is used in a manner to size the entry heat load for a given flexible TPS (FTPS) thickness so that it meets project reliability standards while allowing the FTPS and the underlying inflatable structure (IS) to be pushed to adequately high temperatures. Since the LOFTID project is an experimental flight demonstration, it is de-sired to drive the FTPS and IS to temperatures that cover a large range of their thermal response models’ applicability. This will allow the thermal response models to be better improved and validated post-flight using LOFTID’s extensive instrumentation embedded within the aeroshell. The presentation demonstrates how uncertainty analysis is carried out using an end-to-end Monte Carlo process where three separate Monte Carlo simulations are run in sequence. The first Monte Carlo simulation operates on the entry trajectory model to generate trajectory parameter dispersions that are fed into the second Monte Carlo simulation. The second Monte Carlo simulation operates on the aerothermodynamics model to generate aeroheating parameter dispersions that are fed into the third Monte Carlo simulation. The third Monte Carlo simulation operates on the FTPS material thermal response model to generate the final FTPS/IS thermal response dispersions. The end-to-end Monte Carlo simulation propagates the uncertainties of each model into the next to quantify the resulting uncertainty of the FTPS/IS thermal response. The fractional contributions of the uncertain parameters in the trajectory, aerothermal, and thermal response models to the variance in the FTPS/IS thermal response is determined as a byproduct of the Monte Carlo analysis. The structural uncertainty of the FTPS thermal response model is evaluated by flight relevant ground testing and model error analysis using test measurements. This probabilistic TPS margin process had never been applied to an entry vehicle and it is one of the LOFTID project’s goals to demonstrate its merits.

Steven A. Tobin↗

Thermal and dynamic partition of dumbbell interstitials in complex concentrated alloys

Complex concentrated alloys (CCAs) are promising candidates for applications in extreme conditions, such as irradiation where interstitial mediated diffusion is important. In CCAs with N principal elements, $\frac{N(N+1)}{2}$ types of dumbbell interstitials exist. Currently, there is no way to predict the thermal partition (fractional concentration at equilibrium) and the dynamic partition (fractional time an interstitial spends during diffusion) of each type of dumbbell interstitial. To mitigate this issue, this work proposes a theoretical model for computing the equilibrium concentrations and thermal partition of dumbbell interstitials in CCAs and validates the model using grand canonical Monte Carlo simulations. Lattice kinetic Monte Carlo simulations show that the thermal partition is equivalent to the dynamic partition, and both are governed by composition and formation energies of dumbbells. As a result, the model proposed provides a foundation for understanding radiation enhanced diffusion and induced segregation in CCAs under irradiation.

36 MATERIALS SCIENCE↗

Dynamic Stability of Uncertain Laminated Beams Under Subtangential Loads

Because of the inherent complexity of fiber-reinforced laminated composites, it can be challenging to manufacture composite structures according to their exact design specifications, resulting in unwanted material and geometric uncertainties. In this research, we focus on the deterministic and probabilistic stability analysis of laminated structures subject to subtangential loading, a combination of conservative and nonconservative tangential loads, using the dynamic criterion. Thus a shear-deformable laminated beam element, including warping effects, is derived to study the deterministic and probabilistic response of laminated beams. This twenty-one degrees of freedom element can be used for solving both static and dynamic problems. In the first-order shear deformable model used here we have employed a more accurate method to obtain the transverse shear correction factor. The dynamic version of the principle of virtual work for laminated composites is expressed in its nondimensional form and the element tangent stiffness and mass matrices are obtained using analytical integration The stability is studied by giving the structure a small disturbance about an equilibrium configuration, and observing if the resulting response remains small. In order to study the dynamic behavior by including uncertainties into the problem, three models were developed: Exact Monte Carlo Simulation, Sensitivity Based Monte Carlo Simulation, and Probabilistic FEA. These methods were integrated into the developed finite element analysis. Also, perturbation and sensitivity analysis have been used to study nonconservative problems, as well as to study the stability analysis, using the dynamic criterion.

Goyal, Vijay K.↗

NASA CEV On-Orbit GN&C Analysis

The Orion spacecraft orbit GN&C system will be required to perform both ISS servicing missions and Lunar sortie and outpost crew transportation. While certain aspects of these two missions are complementary, the two missions are also distinct in many ways. Common between the missions is a Low Earth Orbit (LEO) rendezvous, one with the ISS And the other with the LSAM/EDS stack prior to trans-lunar insertion. The lunar missions will additionally require Orion to perform orbit maintenance in LLO, perform contingency lunar orbit operations including RPOD with the LSAM, perform the TEI maneuver sequence, and execute the trans-Earth cruise. The NASA-led team developed a reference configuration orbit GN&C system capable of executing all of these activities with the same navigation sensor suite and control effectors while fully meeting the requirements being developed for System Requirements Review in advance of prime contractor selection. This paper will present an overview of the analyses performed to support system trade studies, demonstrate the feasibility of the NASA reference configuration, and validate the Orion system requirements. These analyses include linear covariance techniques, 3-DOF Monte Carlo simulations, 6-DOF Monte Carlo simulations, and analytical evaluations of GN&C systems performed by the NASA-led Orion team to characterize the sensitivities of Orion s various missions and assess the unique challenges of each. The first part of this paper will describe the trade studies that were performed in order to characterize the RPOD system performance for both the ISS and the lunar missions including development of an RPOD operations concept, RPOD trajectories, contingency scenarios, docking mechanism and associated contact conditions, post-contact thrust issues, relative navigation sensors, relative navigation sensor target infrastructure. The paper will also discuss concepts for both manually-piloted and automatically executed scenarios, as well as the remotely-piloted contingency scenario in LLO. The second part of the paper will discuss the analyses performed for lunar and cislunar GN&C performance including the accuracy of the post-insertion lunar orbit, the ability of Orion to hit a particular Earth return entry corridor, attitude control solutions for long-duration surface operations, and autonomous navigation in support of TEI without ground tracking.

DSouza, Chris↗

Data decomposition of Monte Carlo particle transport simulations via tally servers

An algorithm for decomposing large tally data in Monte Carlo particle transport simulations is developed, analyzed, and implemented in a continuous-energy Monte Carlo code, OpenMC. The algorithm is based on a non-overlapping decomposition of compute nodes into tracking processors and tally servers. The former are used to simulate the movement of particles through the domain while the latter continuously receive and update tally data. A performance model for this approach is developed, suggesting that, for a range of parameters relevant to LWR analysis, the tally server algorithm should perform with minimal overhead on contemporary supercomputers. An implementation of the algorithm in OpenMC is then tested on the Intrepid and Titan supercomputers, supporting the key predictions of the model over a wide range of parameters. We thus conclude that the tally server algorithm is a successful approach to circumventing classical on-node memory constraints en route to unprecedentedly detailed Monte Carlo reactor simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A lumped particle direct simulation Monte-Carlo method combined with the collisional-radiative model for simulations of non-equilibrium laser-induced plasma plumes

Collisional plasma plumes induced by laser irradiation of material targets exhibit large variations in local density as well as ionization and excitation states, making purely hydrodynamic or kinetic simulations inaccurate or infeasible. To address this challenge and capture non-equilibrium effects in laser-induced plasma plumes at arbitrary degrees of ionization, we develop a hybrid computational approach that combines the kinetic direct simulation Monte Carlo (DSMC) method with a collisional-radiative model (CRM). This ℓDSMC-CRM approach utilizes a lumped particle method to represent minor fractions of excited ions in particle-based simulations and a special coarse-graining technique for atomic spectra and photoionization rates, ensuring numerical convergence at reduced computational cost. The hybrid approach is applied to simulate spatially homogeneous relaxation as well as one- and two-dimensional expansions of plasma plumes induced by irradiation of a copper target by a nanosecond laser pulse in a vacuum or background gas. The comparison with an equilibrium model, where local Saha-Boltzmann equilibrium is enforced, shows that the non-equilibrium effects play a dominant role. The equilibrium model can fail to predict the flow structure and strongly underestimate the degree of absorption of laser radiation by the plume. The ℓDSMC-CRM approach is validated against experimental data demonstrating reasonable agreement with the experimental electron density and temperature, while the equilibrium model is found to dramatically underestimate electron density and temperature. The flexibility of the ℓDSMC-CRM approach allows for its seamless integration into existing DSMC frameworks, making it a valuable tool for high-fidelity plasma modeling in laser-material interactions, laser-based manufacturing, and beyond.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNPX Monte Carlo burnup simulations of the isotope correlation experiments in the NPP obrigheim.

This paper describes the simulation work of the Isotope Correlation Experiment (ICE) using the MCNPX Monte Carlo computer code package. The Monte Carlo simulation results are compared with the ICE-Experimental measurements for burnup up to 30 GWD/t. The comparison shows the good capabilities of the MCNPX computer code package for predicting the depletion of the uranium fuel and the buildup of the plutonium isotopes in a PWR thermal reactor. The Monte Carlo simulation results show also good agreements with the experimental data for calculating several long-lived and stable fission products. However, for the americium and curium actinides, it is difficult to judge the predication capabilities for these actinides due to the large uncertainties in the ICE-Experimental data. In the MCNPX numerical simulations, a pin cell model is utilized to simulate the fuel lattice of the nuclear power reactor. Temperature dependent libraries based on JEFF3.1 nuclear data files are utilized for the calculations. In addition, temperature dependent libraries based ENDF/B-VII nuclear data files are utilized and the obtained results are very close to the JEFF3.1 results, except for {approx}10% differences in the prediction of the minor actinide isotopes buildup.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diagnosing Undersampling Biases in Monte Carlo Eigenvalue and Flux Tally Estimates

Here, this study focuses on understanding the phenomena in Monte Carlo simulations known as undersampling, in which Monte Carlo tally estimates may not encounter a sufficient number of particles during each generation to obtain unbiased tally estimates. Steady-state Monte Carlo simulations were performed using the KENO Monte Carlo tools within the SCALE code system for models of several burnup credit applications with varying degrees of spatial and isotopic complexities, and the incidence and impact of undersampling on eigenvalue and flux estimates were examined. Using an inadequate number of particle histories in each generation was found to produce a maximum bias of ~100 pcm in eigenvalue estimates and biases that exceeded 10% in fuel pin flux tally estimates. Having quantified the potential magnitude of undersampling biases in eigenvalue and flux tally estimates in these systems, this study then investigated whether Markov Chain Monte Carlo convergence metrics could be integrated into Monte Carlo simulations to predict the onset and magnitude of undersampling biases. Five potential metrics for identifying undersampling biases were implemented in the SCALE code system and evaluated for their ability to predict undersampling biases by comparing the test metric scores with the observed undersampling biases. Finally, of the five convergence metrics that were investigated, three (the Heidelberger-Welch relative half-width, the Gelman-Rubin $\hat{R}_c$ diagnostic, and tally entropy) showed the potential to accurately predict the behavior of undersampling biases in the responses examined.

97 MATHEMATICS AND COMPUTING↗

SU-F-I-79: Validation of a Monte Carlo Radiographic Simulation

Purpose: To validate a radiographic simulation in order to estimate patient dose due to clinically-used radiography protocols. Methods: A Monte Carlo simulation was created to simulate a radiographic x-ray beam using GEANT4. Initial validation was performed according to a portion of TG 195. Computational NURBS-based phantoms were used simulate patients of varying ages and sizes. The deposited energy in the phantom is output by the simulation. The exposure in air from a clinically used radiography unit was measured at 100 cm for various tube potentials. 10 million photons were simulated with 1 cubic centimeter of air located 100 cm from the source, and the total absorbed dose was noted. The normalization factor was determined by taking a ratio of the measured dose in air to the simulated dose in air. Dose to individual voxels is calculated using the energy deposition map along with the voxelized and segmented phantom and the normalization factor. Finally, the effective dose is calculated using the ICRP methodology and tissue weighting factors. Results: This radiography simulation allows for the calculation and visualization of the energy deposition map within a voxelized phantom. The ratio of exposure, measured using an ionization chamber, to air in the simulation was determined. Since the simulation output is calibrated to match the exposure of a given clinical radiographic x-ray tube, the dose map may be visualized. This will also allow for absorbed dose estimation in specific organs or tissues as well as a whole body effective dose estimation. Conclusion: This work indicates that our Monte Carlo simulation may be used to estimate the radiation dose from clinical radiographic protocols. This will allow for an estimate of radiographic dose from various examinations without the use of traditional methods such as thermoluminescent dosimeters and body phantoms.

60 APPLIED LIFE SCIENCES↗

SU-E-J-100: Reconstruction of Prompt Gamma Ray Three Dimensional SPECT Image From Boron Neutron Capture Therapy(BNCT)

Purpose: Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography (SPECT) image from boron neutron capture therapy (BNCT) using Monte Carlo simulation. Methods: In case of simulation, the pixelated SPECT detector, collimator and phantom were simulated using Monte Carlo n particle extended (MCNPX) simulation tool. A thermal neutron source (<1 eV) was used to react with the boron uptake region (BUR) in the phantom. Each geometry had a spherical pattern, and three different BURs (A, B and C region, density: 2.08 g/cm3) were located in the middle of the brain phantom. The data from 128 projections for each sorting process were used to achieve image reconstruction. The ordered subset expectation maximization (OSEM) reconstruction algorithm was used to obtain a tomographic image with eight subsets and five iterations. The receiver operating characteristic (ROC) curve analysis was used to evaluate the geometric accuracy of reconstructed image. Results: The OSEM image was compared with the original phantom pattern image. The area under the curve (AUC) was calculated as the gross area under each ROC curve. The three calculated AUC values were 0.738 (A region), 0.623 (B region), and 0.817 (C region). The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm and 1.4 cm. Conclusion: The possibility of extracting a 3D BNCT SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The prospects for obtaining an actual BNCT SPECT image were estimated from the quality of the simulated image and the simulation conditions. When multiple tumor region should be treated using the BNCT, a reasonable model to determine how many useful images can be obtained from the SPECT could be provided to the BNCT facilities. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.200900420) and the Radiation Technology Research and Development program (Grant No.2013043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-58: A Novel Monte Carlo Photon Transport Simulation Scheme and Its Application in Cone Beam CT Projection Simulation

Purpose: Monte Carlo (MC) simulation is an important tool to solve radiotherapy and medical imaging problems. Low computational efficiency hinders its wide applications. Conventionally, MC is performed in a particle-by -particle fashion. The lack of control on particle trajectory is a main cause of low efficiency in some applications. Take cone beam CT (CBCT) projection simulation as an example, significant amount of computations were wasted on transporting photons that do not reach the detector. To solve this problem, we propose an innovative MC simulation scheme with a path-by-path sampling method. Methods: Consider a photon path starting at the x-ray source. After going through a set of interactions, it ends at the detector. In the proposed scheme, we sampled an entire photon path each time. Metropolis-Hasting algorithm was employed to accept/reject a sampled path based on a calculated acceptance probability, in order to maintain correct relative probabilities among different paths, which are governed by photon transport physics. We developed a package gMMC on GPU with this new scheme implemented. The performance of gMMC was tested in a sample problem of CBCT projection simulation for a homogeneous object. The results were compared to those obtained using gMCDRR, a GPU-based MC tool with the conventional particle-by-particle simulation scheme. Results: Calculated scattered photon signals in gMMC agreed with those from gMCDRR with a relative difference of 3%. It took 3.1 hr. for gMCDRR to simulate 7.8e11 photons and 246.5 sec for gMMC to simulate 1.4e10 paths. Under this setting, both results attained the same ∼2% statistical uncertainty. Hence, a speed-up factor of ∼45.3 was achieved by this new path-by-path simulation scheme, where all the computations were spent on those photons contributing to the detector signal. Conclusion: We innovatively proposed a novel path-by-path simulation scheme that enabled a significant efficiency enhancement for MC particle transport simulations.

60 APPLIED LIFE SCIENCES↗

Upsampling Monte Carlo Reactor Simulation Tallies in Depleted Sodium-Cooled Fast Reactor Assemblies Using a Convolutional Neural Network

The computational demand of neutron Monte Carlo transport simulations can increase rapidly with the spatial and energy resolution of tallied physical quantities. Convolutional neural networks have been used to increase the resolution of Monte Carlo simulations of light water reactor assemblies while preserving accuracy with negligible additional computational cost. Here, we show that a convolutional neural network can also be used to upsample tally results from Monte Carlo simulations of sodium-cooled fast reactor assemblies, thereby extending the applicability beyond thermal systems. The convolutional neural network model is trained using neutron flux tallies from 300 procedurally generated nuclear reactor assemblies simulated using OpenMC. Validation and test datasets included 16 simulations of procedurally generated assemblies, and a realistic simulation of a European sodium-cooled fast reactor assembly was included in the test dataset. We show the residuals between the high-resolution flux tallies predicted by the neural network and high-resolution Monte Carlo tallies on relative and absolute bases. The network can upsample tallies from simulations of fast reactor assemblies with diverse and heterogeneous materials and geometries by a factor of two in each spatial and energy dimension. The network’s predictions are within the statistical uncertainty of the Monte Carlo tallies in almost all cases. This includes test assemblies for which burnup values and geometric parameters were well outside the ranges of those in assemblies used to train the network.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration of neutron-yield diagnostics in attenuating and scattering environments

We have performed absolute calibrations of a fusion-neutron-yield copper-activation diagnostic in environments that significantly attenuate and scatter neutrons. We have measured attenuation and scattering effects and have compared the measurements to Monte Carlo simulations using the Monte Carlo N-Particle code. We find that measurements and simulations are consistent within 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using hybrid implicit Monte Carlo diffusion to simulate gray radiation hydrodynamics

This work describes how to couple a hybrid Implicit Monte Carlo Diffusion (HIMCD) method with a Lagrangian hydrodynamics code to evaluate the coupled radiation hydrodynamics equations. This HIMCD method dynamically applies Implicit Monte Carlo Diffusion (IMD) [1] to regions of a problem that are opaque and diffusive while applying standard Implicit Monte Carlo (IMC) [2] to regions where the diffusion approximation is invalid. We show that this method significantly improves the computational efficiency as compared to a standard IMC/Hydrodynamics solver, when optically thick diffusive material is present, while maintaining accuracy. Two test cases are used to demonstrate the accuracy and performance of HIMCD as compared to IMC and IMD. The first is the Lowrie semi-analytic diffusive shock [3]. The second is a simple test case where the source radiation streams through optically thin material and heats a thick diffusive region of material causing it to rapidly expand. We found that HIMCD proves to be accurate, robust, and computationally efficient for these test problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variance Estimation in Monte Carlo Eigenvalue Simulations Using Spectral Analysis Method

The Monte Carlo (MC) method is the 'gold standard' for performing nuclear reactor calculations and criticality safety analyses because of its ability to handle complex geometries and physics. Reactor and criticality safety analyses require solving eigenvalue problems in complex nuclear systems. Once a stationary fission source distribution is obtained in MC simulations, the sample mean of many stationary cycles is calculated. The MC simulation sample mean is typically referred to as a tally. Variance, or standard deviation, of the sample mean/tally is needed to indicate the level of statistical uncertainty in the simulation and to understand the convergence of the sample mean. Current MC codes typically use sample variance to estimate the statistical uncertainty of the simulation and assume that the MC stationary cycles are independent. However, it is known that cycles are correlated, and estimators of the variance that ignore these correlations systematically underestimate the variance. In this paper, we propose a novel method in the Fourier frequency domain to estimate the variance of the sample mean in MC eigenvalue calculations. Results indicate that the proposed estimator can be unbiased compared to the real variance. The proposed estimator requires minimal additional computing effort.