At least 1,027 records · Page 57

Vacuum chamber pressure effects on thrust measurements

Tests were conducted to investigate the effect of vacuum facility pressure on the performance of small thruster nozzles. Thrust measurements of two converging-diverging nozzles with an area ratio of 140 and an orifice plate flowing unheated nitrogen and hydrogen were taken over a wide range of vacuum facility pressures and nozzle throat Reynolds numbers. In the Reynolds number range of 2200 to 12,000 there was no discernable viscous effect on thrust below an ambient to total pressure ratio of 1000. In nearly all cases, flow separation occurred at a pressure ratio of about 1000. This was the upper limit for obtaining an accurate thrust measurement for a conical nozzle with an area ratio of 140.

Sovey, J. S.↗

Flight measurements of surface pressures on a flexible supercritical research wing

A flexible supercritical research wing, designated as ARW-1, was flight-tested as part of the NASA Drones for Aerodynamic and Structural Testing Program. Aerodynamic loads, in the form of wing surface pressure measurements, were obtained during flights at altitudes of 15,000, 20,000, and 25,000 feet at Mach numbers from 0.70 to 0.91. Surface pressure coefficients determined from pressure measurements at 80 orifice locations are presented individually as nearly continuous functions of angle of attack for constant values of Mach number. The surface pressure coefficients are also presented individually as a function of Mach number for an angle of attack of 2.0 deg. The nearly continuous values of the pressure coefficient clearly show details of the pressure gradient, which occurred in a rather narrow Mach number range. The effects of changes in angle of attack, Mach number, and dynamic pressure are also shown by chordwise pressure distributions for the range of test conditions experienced. Reynolds numbers for the tests ranged from 5.7 to 8.4 x 1,000,000.

Eckstrom, C. V.↗

Characterization of simulated small-droplet fuel sprays

A two-fluid pneumatic atomizer operating at relatively high liquid and gas pressures produced water sprays that simulated small-droplet clouds of liquid fuel for use in studying vaporization and fuel-air mixing effects on combustor performance and emissions. To characterize the sprays, a scattered-light scanning instrument was developed and measurements of volume median or volume mean diameter, D sub V.5, were correlated with D sub O, W sub w, and W sub n, i.e., orifice diameter, water, and nitrogen gas flow rates, respectively, to give the general expression: D sub v.5 approx. (D sub o sup 0.2) (W sub w sup m) (W sub n sup n), which yields D sub v.5 = 45 (D sub o sup 0.2) (W sub w sup 0.2) (W sub w sup - 1.2). Values of D sub o, W sub w, and W sub n are in centimeters and grams/second, respectively. Farther downstream at an axial distance of 6.7 cm, exponent m increased from 0.2 to 0.4 and exponent n decreased from -1.2 to -1.0 and at a distance of 25 cm downstream of the atomizer, n decreased to -0.8. The increase in exponent m and decrease in exponent n was attributed to a loss of very small droplets from the spray due primarily to vaporization and diffusion effects on clouds of small droplets traveling a distance of 25 cm.

Ingebo, R. D.↗

Pressure probe and hot-film probe rsponses to acoustic excitation in mean flow

An experiment was conducted to compare the relative responses of a hot-film probe and a pressure probe positioned in a flow duct carrying mean flow and progressive acoustic waves. The response of each probe was compared with that of a condenser-type microphone flush mounted in the duct wall for flow Mach numbers up to about 0.5. The response of the pressure probe was less than that of the flush-mounted microphone by not more than about 2.1 dB at the highest centerline Mach number. This decreased response of the probe can likely be attributed to flow-induced impedance changes at the probe sensor orifices. The response of the hot-film probe, expressed in terms of fluctuating pressure, was greater than that of the flush-mounted microphone by as much as 6.0 dB at the two higher centerline Mach numbers. Removal of the contribution from fluctuating temperature in the hot-film analytical model greatly improved the agreement between the two transducer responses.

Parrott, T. L.↗

Effect of Reynolds Number and Mach Number on flow angularity probe sensitivity

Preliminary calibrations were performed on nine flow angularity probes in the Langley 7- by 10-Foot High-Speed Tunnel (7 x 10 HST) and the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). These probes will be used in surveying the test section flows of the National Transonic Facility (NTF). The probes used in this study have a pyramid head with five pressure orifices. The calibrations consisted of both isolated probe measurements and rake-mounted multiprobe measurements that covered a range of subsonic Mach numbers up to 0.90 and Reynolds numbers per foot up to 40 X 10 to the 6th power. The preliminary calibration in the 7 x 10 HST included testing the probes both individually and in a rake. The 0.3-m TCT calibration tested two probes singly at varying Reynolds numbers. The results from these tests include Mach number, Reynolds number, and rake-mounting effects. The results of these tests showed probe sensitivity to be slightly affected by Mach number. At Reynolds numbers per foot above 10 x 10 to the 6th power, the probe did not exhibit a Reynolds number sensitivity.

Smith, L. A.↗

Hollow cathodes in high pressure arc discharges

An orified hallow cathode was tested at high pressure to improve lifetime and efficiency in arcjet thrusters. It is indicated that the arc would not operate with emission from the insert above 200 torr in nitrogen regardless of insert material, orifice diameter, or gas flow direction. Emission occurred from the insert in argon and xenon although it could not be ascertained whether diffuse or spot emission existed within the cathode. Over the extended range of configurations and operating parameters explored the desired diffuse emission mode could not be obtained at high enough pressures for orified hollow cathodes to operate in the range which is considered for arcjet applications.

Hardy, T. L.↗

Formation and characterization of simulated small droplet icing clouds

Two pneumatic two-fluid atomizers operating at high liquid and gas pressures produced water sprays that simulated small droplet clouds for use in studying icing effects on aircraft performance. To measure median volume diameter, MVD or D sub v.5, of small droplet water sprays, a scattered-light scanning instrument was developed. Drop size data agreed fairly well with calculated values at water and nitrogen pressures of 60 and 20 psig, respectively, and at water and nitrogen pressures of 250 and 100 psig, respectively, but not very well at intermediate values of water and nitrogen pressure. MVD data were correlated with D sub O, W sub N, and W sub w, i.e., orifice diameter, nitrogen, and water flowrate, respectively, to give the expression for MVD in microns.

Ingebo, R. D.↗

Three-dimensional computation of mixing of transverse injector in a ducted supersonic airstream

Numerical solutions of the three-dimensional mass-averaged elliptic Navier-Stokes equations, including species transport, are obtained for nonreacting, turbulent, mixing flow fields for the case of transverse sonic injection of a secondary gas into a supersonic airstream through a circular orifice injector. Results are presented for flow through a constant area duct and through a duct with a rearward-facing step upstream of the injector. The equations are numerically integrated using MacCormack's explicit method and turbulence is included using the Baldwin-Lomax algebraic eddy viscosity model. In the species transport and energy equations, diffusion coefficients based on Fick's law and an assumption of unit Lewis number are applied. The computations were performed on a CDC-VPS-32 (extended version of Cyber-205) using a grid consisting of approximately 200,000 points. The computed results are compared with experimentally observed penetration and spreading boundaries for an injected gas at two dynamic pressure ratios. Three-dimensional flow field structures are dipicted in terms of static pressure, mass fractions of species and velocity vectors.

Uenishi, K.↗

Characterization of simulated small-droplet fuel sprays

A two-fluid pneumatic atomizer operating at relatively high liquid and gas pressures produced water sprays that simulated small-droplet clouds of liquid fuel for use in studying vaporization and fuel-air mixing effects on combustor performance and emissions. To characterize the sprays, a scattered-light scanning instrument was developed and measurements of volume median or volume mean diameter, D sub V.5, were correlated with D sub O, W sub w, and W sub n, i.e., orifice diameter, water, and nitrogen gas flow rates, respectively, to give the general expression: D sub v.5 approx. (D sub O sup 0.2) (W sub w sup m) (W sub n sup n), which yields D sub v.5 = 45 (D sub o sup 0.2) (W sub w sup 0.2) (W sub w sup -1.2). Values of D sub 0, W sub w, and W sub n are in centimeters and grams/second, respectively. Farther downstream at an axial distance of 6.7 cm, exponent m increased from 0.2 to 0.4 and exponent n decreased from -1.2 to -1.0 and at a distance of 25 cm downstream of the atomizer, n decreased to -0.8. The increase in exponent m and decrease in exponent n was attributed to a loss of very small droplets from the spray due primarily to vaporization and diffusion effects on clouds of small droplets traveling a distance of 25 cm.

Ingebo, R. D.↗

An Investigation of Some Aspects of the Sonic Boom by Means of Wind-Tunnel Measurements of Pressures About Several Bodies at a Mach Number of 2.01

An investigation of some aspects of the sonic boom has been made with the aid of wind-tunnel measurements of the pressure distributions about bodies of various shapes. The tests were made in the Langley 4- by 4-foot supersonic pressure tunnel at a Mach number of 2.01 and at a Reynolds number per foot of 2.5 x 10(exp 6). Measurements of the pressure field were made at orifices in the surface of a boundary-layer bypass plate. The models which represented both fuselage and wing types of thickness distributions were small enough to allow measurements as far away as 8 body lengths or 64 chords. The results are compared with estimates made using existing theory. To the first order, the boom-producing pressure rise across the bow shock is dependent on the longitudinal development of body area and not on local details. Nonaxisymmetrical shapes may be replaced by equivalent bodies of revolution to obtain satisfactory theoretical estimates of the far-field pressures.

Carlson, Harry W.↗

Spray Gun With Constant Mixing Ratio

Conceptual mechanism mounted in handle of spray gun maintains constant ratio between volumetric flow rates in two channels leading to spray head. With mechanism, possible to keep flow ratio near 1:1 (or another desired ratio) over range of temperatures, orifice or channel sizes, or clogging conditions.

Simpson, William G.↗

Bonded-Plate Airfoil Construction

Airfoil design for testing in 0.3-m Transonic Cryogenic Tunnel was symmetrical supercritical shape, consistent with flat-bond-plane bonding-and-channeling technology that had been developed. Technique offers greatly increased flexibility in orifice and pressure-channel layout.

Lawing, Pierce L.↗

High-Temperature Vibration Damper

Device for damping vibrations functions at temperatures up to 400 degrees F. Dampens vibrational torque loads as high as 1,000 lb-in. but compact enough to be part of helicopter rotor hub. Rotary damper absorbs energy from vibrating rod, dissipating it in turbulent motion of viscous hydraulic fluid forced by moving vanes through small orifices.

Clarke, Alan↗

NASA dilution jet mixing, phase 3

Many of the gas turbine combustors in operation use multiple rows of dilution jets, and some have geometries that are different from circular holes. The data base available in literature is generally applicable to a single row of circular holes. Tests were performed with uniform mainstream conditions for several orifice plate configurations. Temperature and pressure measurements were made in the test section at 4 axial and 11 transverse stations. These measurements were made with a 60-element rake probe. Test results for some of these cases are discussed.

Srinivasan, R.↗

Low loss injector for liquid propellant rocket engines

A low pressure loss injector element is disclosed for the main combustion chamber of a rocket engine which includes a lox post terminating in a cylindrical barrel. Received within the barrel is a lox plug which is threaded in the lox post and includes an interchangeable lox metering sieve which meters the lox into an annular lox passage. A second annular gas passage is coaxial with the annular lox passage. A cylindrical sleeve surrounds the annular gas passage and includes an interchangeable gas metering seive having metering orifices through which a hot gas passes into the annular passage. The jets which emerge from the annular lox passage and annular gas passage intersect in a recessed area away from the combustion area. Thus, mixing and combustion stability are enhanced.

Vonpragenau, G. L.↗

Aerodynamic characteristics of two-dimensional wing configurations at angles of attack near -90 deg

Wind tunnel tests were conducted to determine the drag of two-dimensional wing sections operating in a near-vertical flow condition. Various leading- and trialing-edge configurations, including plain flaps of 25, 30, and 35% chord were tested at angles of attack from -75 to -105 deg. Reynolds numbers examined ranged from approximately 0.6 x 10 to the 6th power to 1.4 x 10 to the 6th power. The data were obtained using a wind tunnel force and moment balance system and arrays of chordwise pressure orifices. The results showed that significant reductions in drag, beyond what would be expected by virtue of the decreased frontal area, were obtainable with geometries that delayed flow separation. Rapid changes in drag with angle of attack were noted for many configurations. The results, however, were fairly insensitive to Reynolds number variations. Drag values computed from the pressure data generally agreed with the force data within 2%.

Maisel, Martin↗

OH detection by Ford Motor Company

Two different methods for detection of OH are presented: a low pressure flow cell system and a frequency modulation absorption measurement. Using conventional absorption spectroscopy, detection limits were quoted of 1,000,000 OH molecules per cu cm using a 30-minute averaging time on the ground, and a 3-hour averaging time in the air for present apparatus in use. With the addition of FM spectroscopy at 1 GHz, a double-beam machine should permit detectable absorption of and an OH limit of 100,000 per cu cm in a 30-minute averaging time. In the low pressure system on which experiments are ongoing nonexponential time behavior was observed after the decay had progressed to about 0.3 of its original level; this was attributed to ion emission in the photomultiplier. A flame source with OH present at high concentration levels was used as a calibration. It was estimated that within the sampling chamber, 400,000 OH could be measured. With a factor-of-2 loss at the sampling orifice, this means detectability of 5 to 8 x 100,000 cu cm at the present time. This could be reduced by a factor of 2 in one hour averaging time; improvements in laser bandwidth and energy should provide another factor of 2 in sensitivity.

Wang, Charles C.↗

Investigation of a repetitive pulsed electrothermal thruster

A pulsed electrothermal (PET) thruster with 1000:1 ratio nozzle is tested in a repetitive mode on water propellant. The thruster is driven by a 60J pulse forming network at repetition rates up to 10 Hz (600W). The pulse forming network has a .31 ohm impedance, well matched to the capillary discharge resistance of .40 ohm, and is directly coupled to the thruster electrodes without a switch. The discharge is initiated by high voltage breakdown, typically at 2500V, through the water vapor in the interelectrode gap. Water is injected as a jet through a .37 mm orifice on the thruster axis. Thruster voltage, current and impulse bit are recorded for several seconds at various power supply currents. Thruster to power ratio is typically T/P = .07 N/kW. Tank background pressure precludes direct measurement of exhaust velocity which is inferred from calculated pressure and temperature in the discharge to be about 14 km/sec. Efficiency, based on this velocity and measured T/P is .54 + or - .07. Thruster ablation is zero at the throat and becomes measurable further upstream, indicating that radiative ablation is occurring late in the pulse.