Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational adaptability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Evaluation of Autonomous Vehicle Sensing and Compute Load on a Chassis Dynamometer

The sensing and compute load auxiliary energy consumption in autonomous vehicles may be significant due to the large number of sensors and the high compute load from sensor processing and route planning. To understand this issue, this study investigates the top-down energy usage of an electric 2015 Kia Soul fully instrumented with state sensors and a state-specific computer for path planning and sensor processing. A chassis dynamometer was then used to evaluate the cases of (1) no sensors or computation, (2) only sensors operating, and (3) sensors plus compute load. The vehicle was operated autonomously on the dynamometer using a PolySync drive-kit with drive-by-wire longitudinal control. The DynoJet model 224xLC was used to adapt the eddy current dynamometer's road load parameters to comply with an Environmental Protection Agency drive schedule and to evaluate performance against the Argonne National Laboratory Digital Dynamometer Dataset. On the UDDS-HWFET combined driving cycle, the stock battery's range was reduced by 5.6% for sensors alone and 12.2% for sensors and compute load. These results show that the added sensing and compute auxiliary load from automated and autonomous systems is significant and that research efforts need to be spent investigating new energy efficient systems.

Brown, Nicholas E.↗

Experimental Safe Extremum Seeking for Accelerators

Here, we demonstrate the recent designs of safe extremum seeking (Safe ES) on the 1-km-long charged particle accelerator at the Los Alamos Neutron Science Center (LANSCE). Safe ES is a modification of extremum seeking (ES) which, in addition to minimizing an analytically unknown cost, also employs a safety filter based on an analytically unknown control barrier function (CBF) safety metric. Tuning is necessitated by accelerators being large complex systems, with many drifting parameters due to thermal effects and degradation. At the same time, safe operation (the maintenance of state constraints) is crucial, as damage brings astronomical costs, both financially and in operation downtime. Our measured (but analytically unknown) safety metric is the beam current. We perform multivariable Safe ES on three accelerator applications, in which we adapt 4, 6, and 3 magnet strength parameters, respectively. Two of the three applications are for validated simulation models of beamlines at LANSCE: the first for the proton radiography (pRad) beamline of 800-MeV protons for spot size tuning; the second on a high-performance code, HPSim, for tuning the low-energy beam transport (LEBT) region that contains a beam of 750-keV protons. The third is an experimental tuning of the steering magnets in the LEBT at LANSCE.

43 PARTICLE ACCELERATORS↗

In Vivo Thermodynamic Analysis of Glycolysis in Clostridium thermocellum and Thermoanaerobacterium saccharolyticum Using 13 C and 2 H Tracers

Clostridium thermocellum and Thermoanaerobacterium saccharolyticum are thermophilic anaerobic bacteria with complementary metabolic capabilities that utilize distinct glycolytic pathways for the conversion of cellulosic sugars to biofuels. We integrated quantitative metabolomics with 2 H and 13 C metabolic flux analysis to investigate the in vivo reversibility and thermodynamics of the central metabolic networks of these two microbes. We found that the glycolytic pathway in C. thermocellum operates remarkably close to thermodynamic equilibrium, with an overall drop in Gibbs free energy 5-fold lower than that of T. saccharolyticum or anaerobically grown Escherichia coli . The limited thermodynamic driving force of glycolysis in C. thermocellum could be attributed in large part to the small free energy of the phosphofructokinase reaction producing fructose bisphosphate. The ethanol fermentation pathway was also substantially more reversible in C. thermocellummthan in T. saccharolyticum. These observations help explain the comparatively low ethanol titers of C. thermocellum and suggest engineering interventions that can be used to increase its ethanol productivity and glycolytic rate. In addition to thermodynamic analysis, we used our isotope tracer data to reconstruct the T. saccharolyticum central metabolic network, revealing exclusive use of the Embden-Meyerhof-Parnas (EMP) pathway for glycolysis, a bifurcated tricarboxylic acid (TCA) cycle, and a sedoheptulose bisphosphate bypass active within the pentose phosphate pathway. Thermodynamics constitutes a key determinant of flux and enzyme efficiency in metabolic networks. Here, we provide new insights into the divergent thermodynamics of the glycolytic pathways of C. thermocellum and T. saccharolyticum, two industrially relevant thermophilic bacteria whose metabolism still is not well understood. We report that while the glycolytic pathway in T. saccharolyticum is as thermodynamically favorable as that found in model organisms, such as E. coli or Saccharomyces cerevisiae , the glycolytic pathway of C. thermocellum operates near equilibrium. The use of a near-equilibrium glycolytic pathway, with potentially increased ATP yield, by this cellulolytic microbe may represent an evolutionary adaptation to growth on cellulose, but it has the drawback of being highly susceptible to product feedback inhibition. The results of this study will facilitate future engineering of high-performance strains capable of transforming cellulosic biomass to biofuels at high yields and titers.

59 BASIC BIOLOGICAL SCIENCES↗

SMART Scale An Innovative Program Accelerating the Energy Efficiency Market

Small business is a major component of the American economy. More than half of all private sector workers in this country are employed by small businesses and nearly two-thirds of the new jobs generated in the last ten years were created in this sector. Studies have shown that buildings of less than 50,000 square feet represent 94% of the commercial sector and half of all non-residential floor space in the United States. The future of the American economy relies on a vibrant, robust, and profitable small business community. Small and mid-sized businesses (SMB) can increase their profitability by reducing their operating costs through energy efficiency. The SMART Scale program delivers deep retrofits that maximize energy and cost savings for the SMB market and can be adapted throughout the country in markets of all sizes. For the past 14 years, Ecology Action has been perfecting a Direct Install (DI) program for the SMB market that offers this sector the type of sophisticated, comprehensive energy saving opportunities that were previously available only to large commercial and industrial customers. The DI 2.0 model that Ecology Action has administered for several public and investor-owned California utilities, and most recently for the Sacramento Municipal Utilities District (SMUD), provides the template for a successful retrofit program that can address the unique barriers faced by the SMB sector and achieve a greater impact than traditional DI programs. The impressive results produced by the DI 2.0 program prompted the US Department of Energy to award Ecology Action a $2 million grant in 2013 to create, demonstrate and roll out a replicable model for delivering deep retrofits to small commercial buildings. The grant enabled Ecology Action to build on the success of DI 2.0 by incorporating improvements into the model, market-testing it and designing a costeffective method of achieving significant energy savings for small businesses across the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware Acceleration of Adaptive Neural Algorithms.

As tradit ional numerical computing has faced challenges, researchers have turned towards alternative computing approaches to reduce power - per - computation metrics and improve algorithm performance. Here, we describe an approach towards non - conventional computing that strengthens the connection between machine learning and neuroscience concepts. The Hardware Acceleration of Adaptive Neural Algorithms (HAANA) project ha s develop ed neural machine learning algorithms and hardware for applications in image processing and cybersecurity. While machine learning methods are effective at extracting relevant features from many types of data, the effectiveness of these algorithms degrades when subjected to real - world conditions. Our team has generated novel neural - inspired approa ches to improve the resiliency and adaptability of machine learning algorithms. In addition, we have also designed and fabricated hardware architectures and microelectronic devices specifically tuned towards the training and inference operations of neural - inspired algorithms. Finally, our multi - scale simulation framework allows us to assess the impact of microelectronic device properties on algorithm performance.

97 MATHEMATICS AND COMPUTING↗

AC and DC Hybrid Distribution Grids with Solar Integration: Architecture, Stabilization and Cost Assessment

In this project, a holistic analysis of architecture, stabilization, and cost/efficiency analysis in hybrid AC and DC distribution grids are conducted. Particularly, versatile and cost-efficient multiport converters are developed to not only integrate solar sources and other DERs in DC grids, but also facilitate the interactive operation of DC sub-grids and conventional AC distribution grids. Meanwhile, a universal and extended impedance-based stabilization approach with a decentralized and adaptive virtual impedance loop is developed in hybrid AC and DC distribution grids, which comprehensively covers the active stabilization of DC sections, AC sections, and interface inverters interlinking both AC and DC sections. Furthermore, to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and quantify the improvement of hybrid AC and DC grids over conventional pure AC grids, the project team develops an alpha-version tool to monitor and calculate the efficiency and cost of the DC, AC, or hybrid AC and DC grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Completion Design Considerations for a Horizontal Enhanced Geothermal System

The petroleum industry has had considerable success in recent decades in developing unconventional shale plays using horizontal drilling and multi-zonal isolation and stimulation techniques to fracture tight formations to enable the commercial production of oil and gas. Similar well completions could be used in Enhanced Geothermal Systems (EGS) to create multiple fractures from horizontal wells. This study assesses whether well completion techniques used in the unconventional shale industry to create multi-stage fractures can be applied to an enhanced geothermal system, with a focus on the completion of the EGS injection well. This study assumes an Enhanced Geothermal System (EGS) consisting of a central horizontal injection well flanked on each side by horizontal production wells, connected to the injection well by multiple fractures. The focus is on the design and completion of the horizontal well. For the purpose of developing design criteria, a reservoir temperature of 200 degrees C (392 degrees F) and an injection well flow rate of 87,000 barrels per day (160 kg/s), corresponding to production well flow rates of 43,500 barrels per day (80 kg/s) is assumed. The analysis found that 9-5/8 inches 53.5 pounds per foot (ppf) P110 casing string with premium connections meets all design criteria for the horizontal section of injection well. A P110 grade is fairly common and is often used in horizontal sections of shale development wells in petroleum operations. Next, several zonal isolation systems commonly used in the shale gas industry were evaluated. Three techniques were evaluated -- a 'plug and perf' design, a 'sand and perf' design, and a 'packer and port' design. A plug and perf system utilizes a cemented casing throughout the length of the injector wellbore. The sand and perf system is identical to the plug and perf system, but replaces packers with sand placed in the casing after stimulation to screen out the stimulated perforated zones and provide zonal isolation. The packer and port completion approach utilizes an open horizontal hole that zonally isolates areas through the use of external packers and a liner. A review of technologies used in these systems was performed to determine if commercially available equipment from the petroleum industry could be used at the temperatures, pressures, and sizes encountered in geothermal settings. The study found no major technical barriers to employing shale gas multi-zonal completion techniques in a horizontal well in a geothermal setting for EGS development. For all techniques considered, temperature limitations of equipment are a concern. Commercially available equipment designed to operate at the high temperatures encountered in geothermal systems are available, but is generally unproven for geothermal applications. Based on the study, further evaluation of adapting oil and gas completion techniques to EGS is warranted.

15 GEOTHERMAL ENERGY↗

Nonlinear model predictive control for chemical looping process

A control system for optimizing a chemical looping ("CL") plant includes a reduced order mathematical model ("ROM") that is designed by eliminating mathematical terms that have minimal effect on the outcome. A non-linear optimizer provides various inputs to the ROM and monitors the outputs to determine the optimum inputs that are then provided to the CL plant. An estimator estimates the values of various internal state variables of the CL plant. The system has one structure adapted to control a CL plant that only provides pressure measurements in the CL loops A and B, a second structure adapted to a CL plant that provides pressure measurements and solid levels in both loops A, and B, and a third structure adapted to control a CL plant that provides full information on internal state variables. A final structure provides a neural network NMPC controller to control operation of loops A and B.

97 MATHEMATICS AND COMPUTING↗

Where There’s a Way, There's a Will: The World Customs Organization's Capacity-Building in the Field of Strategic Trade Control Enforcement

The World Customs Organization’s (WCO) approach to capacity building in the domain of strategic trade control enforcement has been exceptionally effective. This article outlines what the WCO has done, documents some of the impacts, and examines factors contributing to its effectiveness. An important factor contributing to the WCO's success has been a focus on influencing senior policy makers at the national level in addition to upgrading working-level skills and abilities. This strategy in turn owes its success, at least in part, to the WCO’s legitimacy and norm-setting ability as a member-driven international organization, a customizable approach adaptive to various national circumstances, adherence to universal international mandates such as United Nations Security Council Regulation 1540, and the ability to couple training and operational activities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Design and Operability of a Pressurized Oxy Combustion System

Fossil fuel powers more than two-thirds of the world’s electricity, a significant share of which is derived from coal power plants. Despite coal being an abundant and energy-rich fuel, the major halt to its progress is greenhouse gas emissions. Pressurized oxy-combustion cycles can achieve theoretically high thermal efficiencies along with a 90% carbon capture rate. Additionally, the high energy density allows smaller turbomachinery and save capital cost. Thus, the primary objective of this dissertation is to present the design and operability of a pressurized oxy-combustor system. The initial part of the dissertation investigates different thermodynamic cycles and presents a model that can be adapted for existing power plants. The thermodynamic model will be used in the later part to design the proposed combustor. The two cycles analyzed are ENEL and TIPS. This study focuses on qualitative analyses of the cycles using a commercially available software called Aspen Plus®. A detailed benchmark study has been performed to validate the modeling process. ENEL and TIPS cycles are designed in the software, adopting the same principles. Recirculation ratio and pressures are varied to find the efficiency range of the cycles. Power calculations are done to find overall and net efficiency for a fixed recirculation ratio. The efficiencies of the cycles are compared to select an optimum cycle. A recirculation ratio of 50% is selected for implementation. The comparison shows that ENEL is marginally efficient over TIPS, at the cost of a pressure difference of about 70bars. Technology Readiness Level analysis is performed to present the availability of the specialized equipment for the cycles. From the TRL analysis, it is seen that the cost and availability of high viii pressure equipment surmount the edge of TIPS over ENEL. Thus, ENEL is chosen as the better cycle for investigating a scaled experiment considering efficiency and viability. The later part of the dissertation focuses on developing the combustor's design for a pressurized oxy-combustion cycle. The proposed combustor is a powerhead-mounted design aimed to produce 1MW of thermal outputThe different aspects of the design of a down-fired pressurized swirl combustor are presented in this dissertation.

Chowdhury, Mehrin↗

Projecting Future Colorado River Basin Water and Hydropower Operations

Drought, variable renewable energy (VRE) resources (primarily wind and photovoltaic technologies), and power markets can all impact hydropower plant operations. We analyze how these three factors collectively may potentially change the future operation and economics of federal dams and hydropower plants located in the Colorado River Basin (CRB). Federal CRB energy and capacity resources, including 4,200 MW of hydropower capacity, are marketed by Western Area Power Administration (WAPA) and sold through long-term Firm Electric Service (FES) contracts to entities located in 15 western and central States that serve millions of electricity consumers. The parameters of FES contracts allow a wide range of scheduling flexibility for FES customers. The FES customers will adjust the timing of energy delivery according to the changing water, power market, and VRE contribution level to the power grid. We simulate and project water and hydropower operations with two models: 1) reservoir operation and 2) power system operation (production cost) with various temporal granularity. We consider two sets of grid scenarios (one representing today's infrastructure, and one representing higher VRE contributions in 2036) and two sets of water scenarios (drought and normal hydrology). We modeled scenarios to understand the power market-energy price levels and patterns, FES customer scheduling, hydropower economics, WAPA finances and hydropower operation for various hydrologic conditions, and VRE contribution level to the power grid. The detailed modeling framework includes: (1) creating ensembles of CRB hydrologic and hydropower futures, (2) selecting representative futures, (3) simulation of FES customer contracts, (4) simulating western U.S. power grid economic scheduling and dispatch under two VRE contribution levels, utilizing information from modeling steps (1)-(4), (5) assessment of reservoir water and hydropower operation, and (6) comparing scenario operations and economics. Our study team comprising WAPA, and an interdisciplinary team of national labs will gain insight into how WAPA can prepare for and adapt its practices in response to an evolving U.S. power grid.

Colorado River↗

Efficient Air Dehumidification Can Save 15%-50% of Cooling Energy in Commercial Buildings

Current approach to dehumidification in commercial buildings with chilled/hot water AHU systems is to overcool return + supply air to dewpoint, and then reheat before supply to zone. This is energy inefficient, with reheat often being gas-fired. To reduce energy consumption, building operators will often operate at little-to-no outside air, sacrificing IAQ. Decarbonizing commercial buildings requires solutions to reduce and fully electrify dehumidification energy consumption. The Altaire ADAPT and Conservant HEDS systems aim to solve this problem by decoupling humidity control from cooling reduces energy consumption while enabling improved IAQ management.

commercial buildings↗

3D Sonar for tank waste quantification - 15430

An innovative remote 3D Sonar technology adapted from the oil and gas industry has been successfully applied to the mapping of radioactive sludge deposits during tank, fuel pool and silo remediation operations at the Sellafield site in the UK. The technology can: -Measure the disposition and calculate the volume of settled solids in a waste tank thereby supporting tank closure objectives - Produce accurate 3-D images of solids disposition, structure and tank internals to help identify where sludge deposits and debris are located -Capture real time 'Sonar video' of movement of solids in the tank in real time to aid retrieval - Detect and monitor gas release and bubble generation Aside from direct safety, cost and schedule benefits, improved accuracy and confidence in residual waste volume determinations can lead to increased level of regulator confidence in meeting closure objectives. This technology has potential to bring such benefits to challenges in the DOE estate, such as Savannah River Site (SRS) and Hanford Tank Farms remediation, and operations at the Hanford Waste Treatment Plant. This paper describes the 3D Sonar technology and its applications, and reviews a 3D Sonar demonstration project specifically aimed at enhancing retrieval and closure operations at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Elaborating a First Version of a KIF For The Manche Surface Repository in France - 18060

The concept of a Key Information File developed in the framework of the RK and M international initiative has been tested against the case of the Manche surface repository. Work is still in progress. The aim is to issue a final version before end of year 2018, with the file for the decennial safety assessment update. The KIF will be part of the regulatory required Summary Memory File. Testing the KIF brought several lessons, on the elaboration process of such document, on the adaptation of the KIF concept to a surface repository, on the necessary evolution of the document over time. The Manche repository is the first repository operated by Andra, and the one at its most advanced stage. Therefore, it is de facto a pilot for similar issues encountered on other Andra's repositories. The difficulties encountered, the errors made and analyzed are the basis for improved provisions in other cases. It has been the case for the repository design, when the second surface repository was implemented in the Aube district. It is now the case for the cover design, for monitoring and for memory provisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Image Characterization of Reactions Generated by an Aeroengine Micromixing Injector for Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blend

An aeroengine micromixing injector, originally designed for lean direct injection of jet fuel, was adapted to work with hydrogen, natural gas, and any blend in between. The ultimate goal of the design was to achieve low NOx emissions when operated on pure hydrogen; to better characterize its performance, flame imaging diagnostics was implemented. Three types of cameras mounted parallel to the injector base and pointing towards the quartz combustor cylinder with the same angle were operated simultaneously: Nikon D90, Dynacolor FB-N9-U, and Phantom v7.1, to capture the visible spectrum, OH* chemiluminescence, and dynamic behavior of the flames, respectively. The current work also includes the overlapping of visible spectrum and OH* chemiluminescence, as an effort to qualitatively define the heat release over the flame area, i.e., UV over visible domain. Additionally, a z-type schlieren configuration was employed to reinforce the presence of some small-scale details occurring near the injector outlet ports. Using the airbox pressure drop, preheat temperature, fuel composition and flame temperature as the factors of study, a Box Behnken model was designed yielding into a 16-points matrix for the operability region, at atmospheric pressure. The main responses were extracted from the OH* images, because of its correlation with the flame heat release, these being the flame area and its average brightness, the heat release area and its center of gravity and leading edge. To assess the importance of the main factors and their interactions, an analysis of variance (ANOVA) was performed for each response, considering as significant each contributor with a p-value below 0.05. For these five responses it was found that all four main factors need to be included into the model (most of them because its own significance, others to ensure the model hierarchy), as well as some common interactions as the preheat and flame temperatures or pressure drop and fuel composition, and quadratic terms from fuel composition or flame temperature. Three of the five models presented R2 and coefficient of variance (C.V.) indicators around 0.97 and 5%, respectively; the leading edge ANOVA yielded into R2=0.78 and C.V.=18.88%; and the heat release area showed R2=0.91 and C.V.=24.13%. Lastly, the confinement ratio effect of the combustor over the flame structure was quantified, for three different conditions: the original 80 mm inner diameter and 200 mm length cylinder was compared against a shorter 150 mm tube (same inner diameter) and a narrower 47 mm inner diameter one (same 200 mm length). The length had a smaller effect than the inner diameter, even though both factors were not strong enough to make a significant deviation on most of the flame parameters: the difference was within the repeatability margin of error for the brightness, flame area, and center of gravity and leading edge of the heat release area.

Imaging diagnostics, flame characterization, OH* c↗

Are You Resilient? Site Energy and Water Resilience Indicators

There is growing interest among operators of individual or co-located facilities to plan for utility disruptions caused by natural hazards and threats. Energy and water resilience at the site level can be characterized as the ability to withstand, adapt, and recover from an energy and/or water supply disruption. But how can a site’s energy and water resilience posture be measured? An evaluation framework with clear performance measures or indicators can help organizations establish what it means to be energy and water resilient and assess progress towards meeting resilience goals across sites and over time. Tracking a consistent set of indicators can help organizations identify problem areas that should be addressed and ascertain if energy and water resilience has improved as a result of investments or operational or policy changes. Resilience indicators also provide a means for organizations with geographically distributed sites to identify common problem areas that may require higher-level attention. This paper outlines an approach that organizations can use to measure site energy and water resilience. This approach was developed by Pacific Northwest National Laboratory for the U.S. Department of Energy’s Federal Energy Management Program as part of an effort to help federal agencies plan for energy and water resilience in a more systematic and rigorous way. The paper defines a general structure for defining energy and water resilience indicators, and provides example indicators and potential rating methods.

resilience, metrics for resilience, site resilienc↗

Benefit of Regional Energy Balancing Service on Wind Integration in the Western Interconnection of the United States

Interest in various wide-area balancing schemes to help integrate wind have generated significant interest. As we have shown in past work, large balancing areas not only help with wind integration, but can also increase the efficiency of operations in systems without wind. Recent work on the Western Wind and Solar Integration Study (WWSIS) has found that combining balancing over the WestConnect footprint will increase the efficiency of commitment and dispatch at wind penetrations ranging from 10-20% of annual electricity demand, and will be essential for high penetrations and small balancing areas. In addition the Northwest Wind Integration Action Plan recommended balancing area cooperation as a method to help integrate the large potential wind development. In this paper we investigate the potential impact of a proposed Energy Imbalance Service on the ability of the non-market portions of Western Electricity Coordinating Councils (WECC) United States footprint to integrate wind energy. We will utilize data adapted from the WWSIS for the Western Interconnection. The analysis uses time-synchronized wind and load data to evaluate the potential for ramp requirement reduction that could be achieved with combined operation. Chronological analysis and ramp duration analysis quantify the benefit in terms of not only the ramp sizes, but the frequency of the potentially avoided ramps that must be managed by the non-wind generation fleet. Multiple approaches that can be used to achieve these benefits will also be suggested in the paper. We also suggest other approaches that can help achieve much of the benefit of full consolidation without requiring the physical consolidation of balancing areas.

17 WIND ENERGY↗

Scenario adaptive disruption prediction study for next generation burning-plasma tokamaks

Next generation High Performance (HP) tokamaks risk damage from unmitigated disruptions at high current and power. Achieving reliable disruption prediction for a device's HP operation based on its Low Performance (LP) data is a key to its success. In this letter, through explorative data analysis and dedicated numerical experiments on multiple existing tokamaks, we demonstrate how the operational regimes of tokamaks can affect the power of a trained disruption predictor. First, our results suggest data-driven disruption predictors trained on abundant LP discharges work poorly on the HP regime of the same tokamak, which is a consequence of the distinct distributions of the tightly correlated signals related to disruptions in these two regimes. Second, we find that matching operational parameters among tokamaks strongly improves cross-machine accuracy which implies our model learns from the underlying scalings of dimensionless physics parameters like q 95 , β p and confirms the importance of these parameters in disruption physics and cross machine domain matching from the data-driven perspective. Finally, our results show in the absence of HP data from the target devices, the best predictivity of the HP regime for the target machine can be achieved by combining LP data from the target with HP data from other machines. Furthermore, these results provide a possible disruption predictor development strategy for next generation tokamaks, such as ITER and SPARC, and highlight the importance of developing baseline scenario discharges of future tokamaks on existing machines to collect more relevant disruptive data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗