Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

An Automatic Learning Framework for Smart Residential Communities

Predictability has been foundational to matching supply and demand in the day-to-day operation of the electric power system. Demand predictability is eroding because of the increased use of renewable energy resources and more sophisticated loads, such as electric vehicles and smart appliances. In this paper, an automatic software framework is described which can be used for load forecasting in smart communities. A time-varying clustering-based Markov chain approach is used to predict the energy consumption of residential buildings in a smart community. The training data is based on 1-minute meter data of occupied homes over one month. The data points are first clustered based on the energy consumption and the time of the day. Then, the original data is converted using the Centroids of the clusters. A time-varying Markov chain is subsequently trained to model the energy consumption behavior of residents for each home using the transformed data. The trained model is shown to successfully predict load in 5-minute intervals over a 24 hours period.

Zandi, Helia↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

A disk-based dynamical constraint on the mass of the young binary DQ Tau

We present new Atacama Large Millimeter/Submillimeter Array (ALMA) observations of CO J = 2−1 line emission from the DQ Tau circumbinary disk. These data are used to tomographically reconstruct the Keplerian disk velocity field in a forward-modeling inference framework, and thereby provide a dynamical constraint on the mass of the DQ Tau binary of M{sub ∗}=1.27{sub −0.27}{sup +0.46} M{sub ⊙}. Those results are compared with an updated and improved orbital solution for this double-lined system based on long-term monitoring of its stellar radial velocities. Both of these independent dynamical constraints on the binary mass are in excellent agreement: taken together, they demonstrate that the DQ Tau system mass is 1.21 ± 0.26 M{sub ⊙} and that the disk and binary orbital planes are aligned within 3° (at 3σ confidence). The predictions of various theoretical models for pre-main-sequence stellar evolution are also consistent with these masses, though more detailed comparisons are difficult due to lingering uncertainties regarding the photospheric properties of the individual components. DQ Tau is the third, nearly equal-mass, double-lined spectroscopic binary with a circumbinary disk that has been dynamically “weighed” with these two independent techniques: all show consistent results, validating the overall accuracy of the disk-based approach and demonstrating that it can be robustly applied to large samples of young, single stars as ALMA ramps up to operations at full capacity.

79 ASTRONOMY AND ASTROPHYSICS↗

A Bird’s Eye View: Development of an Operational ARM Unmanned Aerial Capability for Atmospheric Research in Arctic Alaska

Here, we present that unmanned aerial capabilities offer exciting new perspectives on the Arctic atmosphere and the US Department of Energy is working with partners to offer such perspectives to the research community. Thorough understanding of aerosols, clouds, boundary layer structure and radiation is required to improve representation of the Arctic atmosphere in weather forecasting and climate models. To develop such understanding, new perspectives are needed to provide details on the vertical structure and spatial variability of key atmospheric properties, along with information over difficult-to-reach surfaces such as newly-forming sea ice. Over the last three years, the US Department of Energy (DOE) has supported various flight campaigns using unmanned aircraft systems (UAS, also known as UAVs and drones) and tethered balloon systems (TBS) at Oliktok Point, Alaska. These activities have featured in-situ measurements of thermodynamic state, turbulence, radiation, aerosol properties, cloud microphysics and turbulent fluxes to provide a detailed characterization of the lower atmosphere. Alongside a suite of active and passive ground-based sensors and radiosondes deployed by the DOE Atmospheric Radiation Measurement (ARM) program through the third ARM Mobile Facility (AMF-3), these flight activities demonstrate the ability of such platforms to provide critically-needed information. In addition to providing new and unique datasets, lessons learned during initial campaigns have assisted toward the development of an exciting new community resource.

54 ENVIRONMENTAL SCIENCES↗

Small Scale Field Test Demonstrating CO 2 Sequestration In Arbuckle Saline Aquifer And By CO 2 -Eor At Wellington Field, Sumner County, Kansas

The objectives of this project are to understand the processes that occur when a maximum of 70,000 metric tonnes of CO 2 are injected into two different formations to evaluate the response in different lithofacies and depositional environments. The evaluation will be accomplished through the use of both in situ and indirect MVA (monitoring, verification, and accounting) technologies. The project will optimize for carbon storage accounting for 99% of the CO 2 using lab and field testing and comprehensive characterization and modeling techniques. Site characterization and CO 2 injection should demonstrate state-of-the-art MVA tools and techniques to monitor and visualize the injected CO 2 plume and to refine geomodels developed using nearly continuous core, exhaustive wireline logs, and well tests and a multi-component 3-D seismic survey. Reservoir simulation studies will map the injected CO 2 plume and estimate tonnage of CO 2 stored in solution, as residual gas, and by mineralization and integrate MVA results and reservoir models shall be used to evaluate CO 2 leakage. A rapid-response mitigation plan was developed to minimize CO 2 leakage and provide a comprehensive risk management strategy. The CO 2 was intended to be supplied from a reliable facility and have an adequate delivery and quality of CO 2 . However, several unforeseen circumstances complicated this plan: (1) the initially negotiated CO 2 supply facility went offline and contracts associated with CO 2 supply had to be renegotiated, (2) a UIC Class VI permit proved to be difficult to obtain due to the experimental nature of the project. Both subjects are detailed in separate deliverables attached to this report. The CO 2 enhanced oil recovery (EOR) and geologic storage in Mississippian carbonate reservoir was sucessully deployed. Approximately 20,000 metric tons of CO 2 was injected in the upper part of the Mississippian reservoir to verify CO 2 EOR viability in carbonate reservoirs and evaluate a potential of transitioning to geologic CO 2 storage through EOR. A total of 1,101 truckloads, 19,803 metric tons—an average of 120 tonnes per day—were delivered over the course of injection that lasted from January 9 to June 21, 2016. After cessation of CO 2 injection, the KGS 2-32 well was converted to water injector and continues to operate. CO 2 EOR progression in the field was monitored weekly with fluid level, temperature, and production recording and formation fluid composition sampling. It is important to note that normally, CO 2 EOR pilots are less efficient than commercial operations due to lack of directional and precise well control, lack of surface facilities for CO 2 recycling, and other factors. As a result of this pilot CO 2 injection, the observed incremental average oil production increase was ~68% with only ~18% of injected CO 2 produced back. Decline curve analysis forecasts of additional cumulative oil produced were 32.44M STB to the end of 2027. Wellington Mississippian pilot efficiency by the end of forecast calculations is 11 MCF per barrel of produced oil. Using 32M STB oil production and $1,964,063 cost of CO 2 , CO 2 EOR cost per barrel of oil production is ~$60. Simple but robust monitoring technologies proved to be very efficient in detecting and locating CO 2 . High CO 2 reservoir retentions with low yields within an actively producing field could help to estimate real-world risks of CO 2 geological storage for future projects. The Wellington Field CO 2 EOR was executed in a controlled environment with high efficiency. This case study proves that CO 2 EOR could be successfully applied in Kansas carbonate reservoirs if CO 2 sources and associated infrastructure are available. Recent developments in unconventional resources development in Mid-Continent USA and associated large volume disposal of backflow water and the resulting seismic activity have brought more focus and attention to the Arbuckle Group in southern Kansas. Despite the commercial interest, limited essential information about reservoir properties and structural elements has impeded the management and regulation of disposal, an issue brought to the forefront by recent seismicity in and near areas of large volumes and rates of brine disposal. The Kansas Geological Survey (KGS) collected, compiled, and analyzed available data, including well logs, core data, step rate tests, drill stem tests, 2-D and 3-D seismic data, water level measurements, and others types of data. Several exploratory wells were drilled and core was collected and modern suites of logs were analyzed. Reservoir properties were populated into several site-specific geological models. The geological models illustrate the highly heterogeneous nature of the Arbuckle Group. Vertical and horizontal variability results in several distinct hydro-stratigraphic units that are the result of both depositional and diagenetic processes. During the course of this project, it has been demonstrated that advanced seismic interpretation methods can be used successfully for characterization of the Mississippian reservoir and Arbuckle saline aquifer. Analysis of post-stack 3-D seismic data at the Mississippian reservoir showed the response of a gradational velocity transition. Pre-stack gather analysis showed that porosity zones of the Mississippian and Arbuckle reservoirs exhibit characteristic amplitude versus offset (AVO) response. Simultaneous AVO inversion estimated P- and S-impedances. The 3-D survey gather azimuthal anisotropy analysis (AVAZ) provided information about the fault and fracture network and showed good agreement to the regional stress field and well data. Mississippian reservoir porosity and fracture predictions agreed well with the observed mobility of injected CO 2 in KGS well 2-32. Fluid substitution modeling predicted acoustic impedance reduction in the Mississippian carbonate reservoir introduced by the presence of CO 2 . Seismicity in the United States midcontinent has increased by orders of magnitude over the past decade. Spatiotemporal correlations of seismicity to wastewater injection operations have suggested that injection-related pore fluid pressure increases are inducing the earthquakes. In this investigation, we examine earthquake occurrence in southern Kansas and northern Oklahoma and its relation to the change in pore pressure. The main source of data comes from the Wellington Array in the Wellington oil field, in Sumner County, Kansas, which has monitored for earthquakes in central Sumner County, Kansas, since early 2015. The seismometer array was established to monitor CO 2 injection operations at Wellington Field. Although no seismicity was detected in association with the spring 2016 Mississippian CO 2 injection, the array has recorded more than 2,500 earthquakes in the region and is providing valuable understanding to induced seismicity. A catalog of earthquakes was built from this data and was analyzed for spatial and temporal changes, stress information, and anisotropy information. The region of seismic concern has been shown to be expanding through use of the Wellington earthquake catalog, which has revealed a northward progression of earthquake activity reaching the metropolitan area of Wichita. The stress orientation was also calculated from this earthquake catalog through focal mechanism inversion. The calculated stress orientation was confirmed through comparison to other stress measurements from well data and previous earthquake studies in the region. With this knowledge of the stress orientation, the anisotropy in the basement could be understood. This allowed for the anisotropy measurements to be correlated to pore pressure increases. The increase in pore pressure was monitored through time-lapse shear-wave anisotropy analysis. Since the onset of the observation period in 2010, the orientation of the fast shear wave has rotated 90°, indicating a change associated with critical pore pressure build up. The time delay between fast and slow shear wave arrivals has increased, indicating a corresponding increase in anisotropy induced by pore pressure rise. In-situ near-basement fluid pressure measurements corroborate the continuous pore pressure increase revealed by the shear-wave anisotropy analysis over the earthquake monitoring period. This research is the first to identify a change in pore fluid pressure in the basement using seismological data and it was recently published in the AAAS journal Science Advances (Nolte et al., 2017). The shear-wave splitting analysis is a novel application of the technique, which can be used in other regions to identify an increase in pore pressure. This increasing pore fluid pressure has become more regionally extensive as earthquakes are occurring in southern Kansas, where they previously were absent. These monitoring techniques and analyses provide new insight into mitigating induced seismicity’s impact on society.

02 PETROLEUM↗

Reliable statistics-based detection and investigation of anomalies in a SMART valve system

Reliable anomaly detection and diagnosis are critical for the safe operation of complex engineered systems. This study presents a unified framework that integrates statistical, model-based, and data-driven techniques for anomaly detection and investigation, demonstrated on SMART valve systems in hybrid energy applications. Four detection methods—mean deviation, seasonal extreme studentized deviate, ARIMA forecasting, and matrix profiling—were implemented and compared. Matrix profiling was particularly effective in revealing subtle deviations and hidden relationships among variables. Anomaly investigation was performed by analyzing variable-level and grouped signal profiles, with system topology incorporated to distinguish primary faults from propagated effects. Grouping signals by type enhanced interpretability, enabling accurate localization of anomalies across multi-dimensional datasets. Experimental results confirmed the framework's capability to consistently detect and isolate anomalies while providing actionable insights into system interdependencies. The proposed methodology offers a robust, interpretable, and scalable solution for condition monitoring, with potential applications in safety-critical domains such as nuclear energy, aerospace, and process industries.

ARIMA models↗

Assessment of the Structural Conditions of the San Clemente a Vomano Abbey

The simultaneous use of a Finite Element (FE) accurate modeling, dynamical tests, model updating and nonlinear analysis are used to describe the integrated approach used by the authors to assess the structural conditions and the seismic vulnerability of an historical masonry structure: the Abbey Church of San Clemente al Vomano, situated in the Notaresco territory (TE, Italy) commissioned by Ermengarda, daughter of the Emperor Ludovico II, and built at the end of IX century together with a monastery to host a monastic community. Dynamical tests 'in operational conditions' and modal identification have been used to perform the FE model validation. Both a simple and direct method as the kinematic analysis applied on meaningful sub-structures and a nonlinear 3D dynamic analysis conducted by using the FE model have been used to forecast the seismic performance of the Church.

58 GEOSCIENCES↗

Bidding Curve Design for Hybrid Power Plants with Uncertain Solar Forecast

This paper presents a novel bidding curve design algorithm tailored for hybrid power plants (HPPs) to participate in the wholesale electricity market. Utilizing forecasts for photovoltaic (PV) generation and available battery power, our algorithm strategically computes the bidding curve to maximize HPP profit while adeptly managing the inherent uncertainty associated with PV power generation. In addition, the introduction of the penalty cost in HPP bidding curves provides the system operator a tool to effectively manage the system-level uncertainty that caused by HPPs. Numerical analysis through Monte Carlo simulations confirms that our bidding curve methodology outperforms the benchmark across various scenarios.

bidding curve↗

Soil Dust Aerosols and Wind as Predictors of Seasonal Meningitis Incidence in Niger

Epidemics of meningococcal meningitis are concentrated in sub-Saharan Africa during the dry season, a period when the region is affected by the Harmattan, a dry and dusty northeasterly trade wind blowing from the Sahara into the Gulf of Guinea. We examined the potential of climate-based statistical forecasting models to predict seasonal incidence of meningitis in Niger at both the national and district levels. We used time series of meningitis incidence from 1986 through 2006 for 38 districts in Niger. We tested models based on data that would be readily available in an operational framework, such as climate and dust, population, and the incidence of early cases before the onset of the meningitis season in January–May. Incidence was used as a proxy for immunological state, susceptibility, and carriage in the population. We compared a range of negative binomial generalized linear models fitted to the meningitis data. At the national level, a model using early incidence in December and averaged November–December zonal wind provided the best fit (pseudo-R2 = 0.57), with zonal wind having the greatest impact. A model with surface dust concentration as a predictive variable performed indistinguishably well. At the district level, the best spatiotemporal model included zonal wind, dust concentration, early incidence in December, and population density (pseudo-R2 = 0.41). We showed that wind and dust information and incidence in the early dry season predict part of the year-to-year variability of the seasonal incidence of meningitis at both national and district levels in Niger. Models of this form could provide an early-season alert that wind, dust, and other conditions are potentially conducive to an epidemic.

59 BASIC BIOLOGICAL SCIENCES↗

National Assessment of Energy Storage for Grid Balancing and Arbitrage: Phase 1, WECC

To examine the role that energy storage could play in mitigating the impacts of the stochastic variability of wind generation on regional grid operation, the Pacific Northwest National Laboratory (PNNL) examined a hypothetical 2020 grid scenario in which additional wind generation capacity is built to meet renewable portfolio standard targets in the Western Interconnection. PNNL developed a stochastic model for estimating the balancing requirements using historical wind statistics and forecasting error, a detailed engineering model to analyze the dispatch of energy storage and fast-ramping generation devices for estimating size requirements of energy storage and generation systems for meeting new balancing requirements, and financial models for estimating the life-cycle cost of storage and generation systems in addressing the future balancing requirements for sub-regions in the Western Interconnection. Evaluated technologies include combustion turbines, sodium sulfur (Na-S) batteries, lithium ion batteries, pumped-hydro energy storage, compressed air energy storage, flywheels, redox flow batteries, and demand response. Distinct power and energy capacity requirements were estimated for each technology option, and battery size was optimized to minimize costs. Modeling results indicate that in a future power grid with high-penetration of renewables, the most cost competitive technologies for meeting balancing requirements include Na-S batteries and flywheels.

energy storage↗

Using Integrated Resource Planning to Encourage Investment in Cost-Effective Energy Efficiency Measures

An integrated resource plan (IRP) is a long-range utility plan for meeting the forecasted demand for energy within a defined geographic area through a combination of supply side resources and demand side resources. Generally speaking, the goal of an IRP is to identify the mix of resources that will minimize future energy system costs while ensuring safe and reliable operation of the system. Thirty-four states currently require some sort of IRP process for electricity planning. Thirteen of those states also use IRP processes for natural gas planning. Significant variation exists concerning whether IRPs are acknowledged or approved by each state’s public utility commission (PUC) and the authority accorded to the plans. In the process of developing an IRP for electricity, planners may consider adding generation capacity, encouraging customer-owned generation and combined heat and power facilities, adding transmission and distribution lines, reducing line losses in the transmission and distribution system, implementing demand response programs, and investing in energy efficiency programs to reduce future demand. Analogous supply side and demand side options exist for natural gas planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bidding Curve Design for Hybrid Power Plants with Uncertain Solar Forecast: Preprint

This paper presents a novel bidding curve design algorithm tailored for hybrid power plants (HPPs) to participate in the wholesale electricity market. Utilizing forecasts for photovoltaic (PV) generation and available battery power, our algorithm strategically computes the bidding curve to maximize HPP profit while adeptly managing the inherent uncertainty associated with PV power generation. In addition, the introduction of the penalty cost in HPP bidding curves provides the system operator a tool to effectively manage the system-level uncertainty that caused by HPPs. Numerical analysis through Monte Carlo simulations confirms that our bidding curve methodology outperforms the benchmark across various scenarios.

bidding curve↗

A Fusion of Geothermal and InSAR Data with Machine Learning for Enhanced Deformation Forecasting at the Geysers

The Geysers geothermal field in California is experiencing land subsidence due to the seismic and geothermal activities taking place. This poses a risk not only to the underlying infrastructure but also to the groundwater level which would reduce the water availability for the local community. Because of this, it is crucial to monitor and assess the surface deformation occurring and adjust geothermal operations accordingly. In this study, we examine the correlation between the geothermal injection and production rates as well as the seismic activity in the area, and we show the high correlation between the injection rate and the number of earthquakes. This motivates the use of this data in a machine learning model that would predict future deformation maps. First, we build a model that uses interferometric synthetic aperture radar (InSAR) images that have been processed and turned into a deformation time series using LiCSBAS, an open-source InSAR time series package, and evaluate the performance against a linear baseline model. The model includes both convolutional neural network (CNN) layers as well as long short-term memory (LSTM) layers and is able to improve upon the baseline model based on a mean squared error metric. Then, after getting preprocessed, we incorporate the geothermal data by adding them as additional inputs to the model. This new model was able to outperform both the baseline and the previous version of the model that uses only InSAR data, motivating the use of machine learning models as well as geothermal data in assessing and predicting future deformation at The Geysers as part of hazard mitigation models which would then be used as fundamental tools for informed decision making when it comes to adjusting geothermal operations.

Yazbeck, Joe (ORCID:0000000302235260)↗

Application of the ORIGEN Fallout Analysis Tool and the DELFIC Fallout Planning Tool to National Technical Nuclear Forensics

The objective of this project was to provide a robust fallout analysis and planning tool for the National Technical Nuclear Forensics interagency ground sample collection team. Their application called for a fast-running, portable mission-planning tool for use in response to emerging improvised nuclear device (IND) post-detonation situations. The project met those goals by research and development of models to predict the physical, chemical, and radiological properties of fallout debris. ORNL has developed new graphical user interfaces for two existing codes, the Oak Ridge Isotope Generation (ORIGEN) code and the Defense Land Fallout Interpretive Code (DELFIC). ORIGEN is a validated, radionuclide production and decay code that has been implemented into the Fallout Analysis Tool to predict the fallout source term nuclide inventory after the detonation of an IND. DELFIC is a validated, physics-based, research reference fallout prediction software package. It has been implemented into the Fallout Planning Tool and is used to predict the fractionated isotope concentrations in fallout, particle sizes, fractionation ratios, dose rate, and integrated dose over the planned collection routes - information vital to ensure quality samples for nuclear forensic analysis while predicting dose to the sample collectors. DELFIC contains a particle activity module, which models the radiochemical fractionation of the elements in a cooling fireball as they condense into and onto particles to predict the fractionated activity size distribution for a given scenario. This provides the most detailed physics-based characterization of the fallout source term phenomenology available in an operational fallout model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Earthquake Nowcasting With Machine Learning: The Role of Strain Hardening in the Earthquake Cycle

Abstract Nowcasting is a term originating from economics, finance, and meteorology. It refers to the process of determining the uncertain state of the economy, markets or the weather at the current time by indirect means. In this paper, we describe a simple two‐parameter data analysis that reveals hidden order in otherwise seemingly chaotic earthquake seismicity. One of these parameters relates to a mechanism of seismic quiescence arising from the physics of strain‐hardening of the crust prior to major events. We observe an earthquake cycle associated with major earthquakes in California, similar to what has long been postulated. An estimate of the earthquake hazard revealed by this state variable time series can be optimized by the use of machine learning in the form of the Receiver Operating Characteristic skill score. The ROC skill is used here as a loss function in a supervised learning mode. Our analysis is conducted in the region of 5° × 5° in latitude‐longitude centered on Los Angeles, a region which we used in previous papers to build similar time series using more involved methods (Rundle & Donnellan, 2020, https://doi.org/10.1029/2020EA001097 ; Rundle, Donnellan et al., 2021, https://doi.org/10.1029/2021EA001757 ; Rundle, Stein et al., 2021, https://doi.org/10.1088/1361-6633/abf893 ). Here we show that not only does the state variable time series have forecast skill, the associated spatial probability densities have skill as well. In addition, use of the standard ROC and Precision (PPV) metrics allow probabilities of current earthquake hazard to be defined in a simple, straightforward, and rigorous way.

58 GEOSCIENCES↗

A Gate-to-Gate Life Cycle Assessment for the CO 2 -EOR Operations at Farnsworth Unit (FWU)

Greenhouse gas (GHG) emissions related to the Farnsworth Unit’s (FWU) carbon dioxide enhanced oil recovery (CO 2 -EOR) operations were accounted for through a gate-to-gate life cycle assessment (LCA) for a period of about 10 years, since start of injection to 2020, and predictions of 18 additional years of the CO 2 -EOR operation were made. The CO 2 source for the FWU project has been 100% anthropogenically derived from the exhaust of an ethanol plant and a fertilizer plant. A cumulative amount of 5.25 × 106 tonnes of oil has been recovered through the injection of 1.64 × 106 tonnes of purchased CO 2 , of which 92% was stored during the 10-year period. An LCA analysis conducted on the various unit emissions of the FWU process yielded a net negative (positive storage) of 1.31 × 106 tonnes of CO 2 equivalent, representing 79% of purchased CO 2 . An optimized 18-year forecasted analysis estimated 86% storage of the forecasted 3.21 × 106 tonnes of purchased CO 2 with an equivalent 2.90 × 106 tonnes of crude oil produced by 2038. Major contributors to emissions were flaring/venting and energy usage for equipment. Improvements on the energy efficiency of equipment would reduce emissions further but this could be challenging. Improvement of injection capacity and elimination of venting/flaring or fugitive gas are methods more likely to be utilized for reducing net emissions and are the cases used for the optimized scenario in this work. This LCA illustrated the potential for the CO 2 -EOR operations in the FWU to store more CO 2 with minimal emissions.

54 ENVIRONMENTAL SCIENCES↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗