Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimized electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen

We present a nanoparticle (NP) label/immunochromatographic electrochemical biosensor (IEB) for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. This IEB integrates the immunochromatographic strip with the electrochemical detector for transducing quantitative signals. The NP label, made of CdSe@ZnS, serves as a signal-amplifier vehicle. A sandwich immunoreaction was performed on the immunochromatographic strip. The captured NP labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane of the test zone. Experimental parameters (e.g., immunoreaction time, the amount of anti-PSA-NP conjugations applied) and electrochemical detection conditions (e.g., preconcentration potential and time) were optimized using this biosensor for PSA detection. The analytical performance of this biosensor was evaluated with serum PSA samples according to the “figure-of-merits” (e.g., dynamic range, reproducibility, and detection limit). The results were validated with enzyme-linked immunosorbent assay (ELISA) and show high consistency. It is found that this biosensor is very sensitive with the detection limit of 0.02 ng/mL PSA and is quite reproducible. This method is rapid, clinically accurate, and less expensive than other diagnosis tools for PSA; therefore, this IEB coupled with a portable electrochemical analyzer shows great promise for simple, sensitive, quantitative point-of-care testing of disease-related protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid and Efficient Redox Processes within 2D Covalent Organic Framework Thin Films

Two-dimensional covalent organic frameworks (2D COFs) are ideally suited for organizing redox-active subunits into periodic, permanently porous polymer networks of interest for pseudocapacitive energy storage. Currently, we describe a method for synthesizing crystalline, oriented thin films of a redox-active 2D COF on Au working electrodes. The thickness of the COF film was controlled by varying the initial monomer concentration. A large percentage (80–99%) of the anthraquinone groups are electrochemically accessible in films thinner than 200 nm, an order of magnitude improvement over the same COF prepared as a randomly oriented microcrystalline powder. As a result, electrodes functionalized with oriented COF films exhibit a 400% increase in capacitance scaled to electrode area as compared to those functionalized with the randomly oriented COF powder. These findings demonstrate the promise of redox-active COFs for electrical energy storage and highlight the importance of controlling morphology for optimal performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium inventory tracking as a non-destructive battery evaluation and monitoring method

Tracking the active lithium (Li) inventory in an electrode shows the true state of a Li battery, akin to a fuel gauge for an engine. However, non-destructive Li inventory tracking is currently unavailable. Here, in this work, we used the theoretical capacity of a transition metal oxide to convert capacity into a Li inventory analysis. The Li inventory in electrodes was tracked reliably to show how battery formulations and test methods affect performance. Contrary to capacity, Li inventory tracking reveals stoichiometric variations near the electrode–electrolyte interface. Verifiable results rationalized differences in measurements, clarifying and reducing interferences from cell formulations and experimental manipulations. By tracing four variables from formation to end-of-life, we characterize electrode and cell performance with a thermodynamic framework. Accurate rationalization of subtle differences in Li inventory utilization promises precise battery engineering, evaluation, failure analysis and risk mitigation. The method could be applicable from cell design optimization and fabrication to battery management, improving battery performance and reliability.

25 ENERGY STORAGE↗

Roll-to-Roll Manufacturing of Solid Oxide Fuel Cells

The overall goal of this project is to develop a high-volume electrode electrolyte assembly (EEA) production capability to significantly increase throughput of solid oxide fuel cell (SOFC) manufacturing and reduce the cost while maintaining the same level of performance. Specifically, four approaches will be adopted: 1) optimization of the lamination process and correlation of the EEA properties and performance with the lamination conditions; 2) scale up of the lamination process and demonstration of >10 ft of EEA; 3) further increase of the EEA throughput via slot-die coating and demonstration of > 5 m/min in coating the thick anode layer; and 4) minimization of the anode thickness to reduce material cost.

30 DIRECT ENERGY CONVERSION↗

The TELEC - A plasma type of direct energy converter

The Thermo-Electronic Laser Energy Converter (TELEC) is a high-power density plasma device designed to convert a 10.6-micron CO2 laser beam into electric power. Electromagnetic radiation is absorbed in plasma electrons, creating a high-electron temperature. Energetic electrons diffuse from the plasma and strike two electrodes having different areas. The larger electrode collects more electrons and there is a net transport of current. An electromagnetic field is generated in the external circuit. A computer program has been designed to analyze TELEC performance allowing parametric variation for optimization. Values are presented for TELEC performance as a function of cesium pressure and for current density and efficiency as a function of output voltage. Efficiency is shown to increase with pressure, reaching a maximum over 45%.

Britt, E. J.↗

Capillary electrophoresis-electrochemistry microfluidic system for the determination of organic peroxides

A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.

NASA Discipline Life Sciences Technologies↗

Synthesis and Characterization of Mixed-Conducting Corrosion Resistant Oxide Supports

An extensive search and evaluation of electrochemically stable catalyst supports (including metal oxides like RuO2-SiO2, RuO2-TiO2, and ITO was perfomed during the 4 years of the project. The suports were also catalyzed by deposition of Pt and tested for its performance and electrochemical stability in RDE and fuel cell experiments. For testing the electrochemical stability and fuel cell performance of the catalysts and supports, we have employed the protocols in use at the Department of Energy and Nissan Technological Center North America (NTCNA). The use of such procedures allows a precise and reproducible estimation of the performance and stability of the materials and permits comparisons among laboratories and DOE funded projects. RuO2-SiO2 catalyst supports showed no loss in surface area during start-stop stability tests that were performed by cycling the electrode potential between 0 V to 1.8 V for 1000 cycles. Catalyzed support (40% Pt/RuO2-SiO2; 1:1 mole ratio) were tested in a PEFC, resulting in a current density of 750 mA/cm2 at 0.6 Volts, and a maximum power density of 570 mW/cm2. Measurements were conducted at 80 ºC with 75% relative humidity of the inlet gases (H2/O2); Pt loadings were 0.4 mg/cm2 at the cathode and 0.2 mg/cm2 at the anode. Start-stop stability tests for support and catalyzed support performed in RDE and PEFC set-ups have confirmed RuO2-TiO2 support stability. The beginning of life performance was exactly equal to end of life performance (in an MEA that has been subjected to severe start-stop cycling for 10,000 start/stop cycles between 1 V to 1.5 V). This result was in sharp contrast to baseline Pt/C catalyst that showed significant performance deterioration after accelerated stability tests. The Pt/TRO showed minimal loss in performance upon exposure to start-stop cycles. The loss in cell voltage at 1 A/cm2 at 100% RH was almost 700 mV for Pt/C whereas it was only ca. 15 mV for Pt/TRO. 40% RH data (of inlet gases) revealed a similar trend in terms of stability – exceptional stability for Pt/TRO as opposed to very poor stability for Pt/HSAC. These observations were attributed to the much higher stability of the TRO support compared to Carbon. The carbon dioxide concentration in the cathode exit stream during the accelerated degradation test with Pt/TRO (start-stop protocol) was extremely low (between 3 to 10 ppm of CO2). In contrast, the CO2 emission levels from a conventional Pt/C catalyst were found to be approx. 200 ppm. This observation was a clear indicator that the main source of carbon being oxidized to carbon dioxide in an MEA was the carbon catalyst support, and not the gas diffusion layer or the graphite flow fields. Indium tin oxide (ITO) was also evaluated as a catalyst support for PEFCs. Pt/ITO was very stable under start-up/shutdown accelerated degradation protocol (RDE tests in perchloric acid). The ECSA change was less than 4% over 10,000 cycles. The load cycling accelerated protocol (from 0.6 to 0.95 V vs. RHE) resulted in a loss of approximately 34% of the initial ECSA after 10,000 cycles. However, fuel cell testing resulted in a very low performing catalyst. XPS spectroscopy was employed to investigate the changes in the catalysts occuring during fuel cell operation. It was observed a shift of In 3d5/2 and In 3d3/2 peaks towards higher binding energies. This can be explained by the formation of hydroxides or oxy-hydroxides in the surface of the catalyst. O1s spectrum for Pt/ITO catalyst after being operated in the fuel cell, also confirmed the formation of significant amounts of surface hydroxides (12 to 16%). The presence of surface hydroxides in the catalyst increased the electrode resistivity affecting fuel cell performance. NTCNA performed a detailed analysis of transport phenomena (reactants and products to/from the Pt active sites) in both commercial catalyst and Pt/RTO (in order to have a better understanding at the basic level). The proton resistance (Rionomer) in Pt/C and Pt/RTO cathode catalyst layers were 150 and 12 mΩ-cm2, respectively. Pt/RTO catalyst layer has about an order or magnitude lower proton transfer resistance than Pt/C catalyst layer. Since the ionomer/support ratio that was used in formulating the ink for both catalysts was the same (0.9), it is expected that the volumetric coverage of ionomer of both catalysts will be significantly different due to the disparity in the surface areas (Pt/C had ~ 800 m2/g, while Pt/RTO had ~ 50 m2/g). The differences in the ionomer volumetric coverage and the ionomer film thickness may explain the significantly higher proton conductivity in the Pt/RTO catalyst layer when compared to Pt/HSAC. It is therefore very important to optimize the ionomer loadings when synthesizing new catalyst supports (and never rely on values for carbon-based commercial catalysts). Finally, NTCNA has elaborated a cost model for non-carbon support materials considering their durability benefits. Material costs for production of Pt/ RuO2-TiO2 electrodes were compared to Pt/C. RuO2-TiO2 support was more expensive than carbon but the total material cost was still dominated by platinum cost. Though ruthenium is considered a precious metal, its cost is far less than platinum. It should also be noted that ruthenium only makes up 38% of the mass of the support, while the rest is inexpensive TiO2. After considering the durability advantages of Pt/RTO, cost model showed that even with almost double the Pt loading (0.35 vs 0.18 mgPt/cm2), Pt/RTO ($22.7/kWnet) is only slightly more expensive than Pt/C ($21.9/kWnet).

08 HYDROGEN↗

Redesign of the Analysing Magnet in the ISIS H{sup -} Penning Ion Source

A full 3D electromagnetic finite element analysis and particle tracking study is undertaken of the ISIS Penning surface plasma H{sup -} ion source. The extraction electrode, 90 deg. analysing magnet, post-extraction acceleration gap and 700 mm of drift space have been modelled in CST Particle Studio 2008 to study the beam acceleration and transport at all points in the system. The analyzing magnet is found to have a sub-optimal field index, causing beam divergence and contributing the beam loss. Different magnet pole piece geometries are modelled and the effects of space charge investigated. The best design for the analysing magnet involves a shallower intersection angle and larger separation of the pole faces. This provides radial focusing to the beam, leading to less collimation. Three new sets of magnet poles are manufactured and tested on the Ion Source Development Rig to compare with predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mitigating mechanical failure of crystalline silicon electrodes for lithium batteries by morphological design [Morphological design of silicon electrode with anisotropic interface reaction rate for lithium ion batteries]

Although crystalline silicon (c-Si) anodes promise very high energy densities in Li-ion batteries, their practical use is complicated by amorphization, large volume expansion and severe plastic deformation upon lithium insertion. Recent experiments have revealed the existence of a sharp interface between crystalline Si (c-Si) and the amorphous Li x Si alloy during lithiation, which propagates with a velocity that is orientation dependent; the resulting anisotropic swelling generates substantial strain concentrations that initiate cracks even in nanostructured Si. Here we describe a novel strategy to mitigate lithiation-induced fracture by using pristine c-Si structures with engineered anisometric morphologies that are deliberately designed to counteract the anisotropy in the crystalline/amorphous interface velocity. This produces a much more uniform volume expansion, significantly reducing strain concentration. Based on a new, validated methodology that improves previous models of anisotropic swelling of c-Si, we propose optimal morphological designs for c-Si pillars and particles. The advantages of the new morphologies are clearly demonstrated by mesoscale simulations and verified by experiments on engineered c-Si micropillars. The results of this study illustrate that morphological design is effective in improving the fracture resistance of micron-sized Si electrodes, which will facilitate their practical application in next-generation Li-ion batteries. In conclusion, the model and design approach present in this paper also have general implications for the study and mitigation of mechanical failure of electrode materials that undergo large anisotropic volume change upon ion insertion and extraction.

25 ENERGY STORAGE↗

Enabling 6C Fast Charging of Li–Ion Batteries with Graphite/Hard Carbon Hybrid Anodes

Li-ion batteries that can simultaneously achieve high-energy density and fast charging are essential for electric vehicles. Graphite anodes enable a high-energy density, but suffer from an inhomogeneous reaction current and irreversible Li plating during fast charging. In contrast, hard carbon exhibits superior rate performance but lower energy density owing to its lower initial coulombic efficiency and higher average voltage. In this work, these tradeoffs are overcome by fabricating hybrid anodes with uniform mixtures of graphite and hard carbon, using industrially-relevant multi-layer pouch cells (>1 Ah) and electrode loadings (3 mAh cm –2 ). By controlling the graphite/hard carbon ratio, this study shows that battery performance can be systematically tuned to achieve both high-energy density and efficient fast charging. Pouch cells with optimized hybrid anodes retain 87% and 82% of their initial specific energy after 500 cycles of 4C and 6C fast-charge cycling, respectively. This is significantly higher than the 61% and 48% specific energy retention with graphite anodes under the same conditions. The enhanced performance is attributed to improved homogeneity of the reaction current throughout the hybrid anode, which is supported by continuum-scale modeling. Furthermore, this process is directly compatible with existing roll-to-roll battery manufacturing, representing a scalable pathway to fast charging.

25 ENERGY STORAGE↗

Capacitive energy storage and recovery for synchrotron magnets

Feasibility studies on capacitive energy storage and recovery in the main-ring synchrotron of the Japan Proton Accelerator Research Complex were conducted by circuit simulation. The estimated load fluctuation was 96 MVA in total for dipole magnets, which is likely to induce a serious disturbance in the main grid. It was found that the energy stored in the magnets after the excitation period can be recovered to the storage capacitor by controlling the voltage across the energy-storage capacitor using a pulse-width-modulation converter and reused in the next operational cycle. It was also found that the power fluctuation in the main grid can be reduced to 12 MVA. An experimental evaluation of an aluminum metalized film capacitor revealed that capacitance loss was induced by a fluctuating voltage applied to the storage capacitor when applying the proposed method. The capacitance loss was induced by corona discharge around the edges of segmented electrodes of a self-healing capacitor. The use of aluminum-zinc alloy was evaluated as a countermeasure to mitigate the effect induced by the corona discharge. For a zinc content of 8%, which was optimized experimentally, a capacitor with a sufficient life time expectancy of 20 years and a working potential gradient of 250 V/μm was developed.

43 PARTICLE ACCELERATORS↗

Electrochemical Sensors for the Detection of Lead and Other Toxic Heavy Metals: The Next Generation of Personal Exposure Biomonitors

To support the development and implementation of biological monitoring programs, accurate and quantitative technologies for measuring xenobiotic exposure are needed. Micro-analytical based sensors that work with complex biomatrices such as blood, urine or saliva are being developed and validated. These sensor platforms will improve our ability to make definitive associations between chemical exposures and disease. Among toxic heavy metals, lead (Pb) continues to be one of the most problematic. Despite a considerable effort to identify and eliminate Pb exposure sources, this metal still remains a significant health concern, particularly for young children. Ongoing research is focused on the development and validation of portable metal analyzers that have many advantages over current available technologies, thus having the potential to become the next-generation of toxic metal analyzers. This review will highlight the development and validation of two classes of metal analyzers for the voltammetric detection of Pb, this includes: (1) a metal analyzer based on flow injection analysis and anodic stripping voltammetry (ASV) at a Hg-film electrode, and (2) mercury-free metal analyzers employing adsorptive stripping voltammetry (AdSV) and novel nanostructure materials which include the self-assembled monolayers on mesoporous supports (SAMMS) and carbon nanotubes (CNTs). These sensors have been optimized to detect Pb in urine, blood, and saliva as accurately as the state-of-the-art-ICP-MS with high reproducibility, and sensitivity, while being much more portable, field-deployable and less expensive than conventional analytical methods. It is anticipated that these improved and portable analytical sensor platforms will facilitate our ability to conduct a meaningful biological monitoring program that will enable us to have a greater understanding of the relationship between chemical exposure assessment and disease outcomes. Keywords: biomonitoring, lead (Pb), sensors, dosimetry technology, exposure assessment

60 APPLIED LIFE SCIENCES↗

Sex Differences in Vagus Nerve Stimulation Effects on Rat Cardiovascular and Immune Systems

Background: Investigations into the benefits of vagus nerve stimulation (VNS) through pre-clinical and clinical research have led to promising findings for treating several disorders. Despite proven effectiveness of VNS on conditions such as epilepsy and depression, understanding of off-target effects and contributing factors such as sex differences can be beneficial to optimize therapy design. New Methods: In this article, we assessed longitudinal effects of VNS on cardiovascular and immune systems, and studied potential sex differences using a rat model of longterm VNS. Rats were implanted with cuff electrodes around the left cervical vagus nerve for VNS, and wireless physiological monitoring devices for continuous monitoring of cardiovascular system using electrocardiogram (ECG) signals. ECG morphology and heart rate variability (HRV) features were extracted to assess cardiovascular changes resulting from VNS in short-term and long-term timescales. We also assessed VNS effects on expression of inflammatory cytokines in blood during the course of the experiment. Statistical analysis was performed to compare results between Treatment and Sham groups, and between male and female animals from Treatment and Sham groups. Results: Considerable differences between male and female rats in cardiovascular effects of VNS were observed in multiple cardiovascular features. However, the effects seemed to be transient with approximately 1-h recovery after VNS. While short-term cardiovascular effects were mainly observed in male rats, females in general showed more significant long-term effects even after VNS stopped. We did not observe notable changes or sex differences in systemic cytokine levels resulting from VNS. Comparison With Existing Methods: Compared to existing methods, our study design incorporated wireless physiological monitoring and systemic blood cytokine level analysis, along with long-term VNS experiments in unanesthetized rats to study sex differences. Conclusion: The contribution of sex differences for long-term VNS off-target effects on cardiovascular and immune systems was assessed using awake behaving rats. Although VNS did not change the concentration of inflammatory biomarkers in systemic circulation for male and female rats, we observed significant differences in cardiovascular effects of VNS characterized using ECG morphology and HRV analyses.

59 BASIC BIOLOGICAL SCIENCES↗

Normal Pulse Voltammetry for Real Time Analysis of Electro-refiner Salt with High Concentrations of Analytes

Spent nuclear fuel pyro-processing could be a preferred alternative for aqueous processing. However, there will be a large hold up of actinides in the molten salt media that must be safeguarded in commercial facilities. A real or near real time monitoring method for electro-refiner salt needs to be developed to meet this requirement. In addition, real time monitoring method can also be applied to optimize process control. Voltammetry would be an ideal method to monitor the ER salt composition because of the low cost and robustness. The equipment required to carry out voltammetry analysis include only a potentiostat and three electrodes, which can be placed in-situ.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GAMPix: a novel fine-grained, low-noise and ultra-low power pixelated charge readout for TPCs

Here, we report on the development of a novel pixel charge readout system, Grid Activated Multi-scale pixel readout (GAMPix), which is under development for use in the GammaTPC gamma ray instrument concept. GammaTPC is being developed to optimize the use of liquid argon time projection chamber technology for gamma ray astrophysics, for which a fine grained low power charge readout is essential. GAMPix uses a new architecture with coarse and fine scale instrumented electrodes to solve the twin problems of loss of measured charge after diffusion, and high readout power. Fundamentally, it enables low noise and ultra low power charge readout at the spatial scale limited by diffusion in a time projection chamber, and has other possibly applications, including future DUNE modules.

Shutt, Tom↗

Na 2 Ti 3 O 7 Nanoplatelets and Nanosheets Derived from a Modified Exfoliation Process for Use as a High-Capacity Sodium-Ion Negative Electrode

The increasing interest in Na-ion batteries (NIBs) can be traced to sodium abundance, its low cost compared to lithium, and its intercalation chemistry being similar to that of lithium. We report that the electrochemical properties of a promising negative electrode material, Na 2 Ti 3 O 7 , are improved by exfoliating its layered structure and forming 2D nanoscale morphologies, nanoplatelets, and nanosheets. Exfoliation of Na 2 Ti 3 O 7 was carried out by controlling the amount of proton exchange for Na + and then proceeding with the intercalation of larger cations such as methylammonium and propylammonium. An optimized mixture of nanoplatelets and nanosheets exhibited the best electrochemical performance in terms of high capacities in the range of 100–150 mA h g –1 at high rates with stable cycling over several hundred cycles. These properties far exceed those of the corresponding bulk material, which is characterized by slow charge-storage kinetics and poor long-term stability. The results reported in this study demonstrate that charge-storage processes directed at 2D morphologies of surfaces and few layers of sheets are an exciting direction for improving the energy and power density of electrode materials for NIBs.

25 ENERGY STORAGE↗

Location-Dependent Cobalt Deposition in Smartphone Cells upon Long-Term Fast-Charging Visualized by Synchrotron X-ray Fluorescence

In this work, we investigate the transition-metal dissolution of the layered cathode material LiCoO 2 upon repeated fast-charging of three smartphone batteries from different manufacturers using synchrotron micro X-ray fluorescence (μ-XRF). Using this spatially resolved technique, dissolution of Co and subsequent location-dependent deposition on the anode are observed. μ-XRF mapping of selected parts of the anode electrode sheets, such as electrode folds and edges of the jelly roll, reveals the difference in the way Co is deposited on specific regions of the anode electrode. While some folds show no depositions, edges of the anode show gradually accumulating Co depositions. Furthermore, careful quantification of the dissolved Co reveals that the capacity loss scales with the amount of deposited Co on the anode, that is, total Co loss from within the cathode. Soft X-ray absorption spectroscopy of the Co depositions on the anode shows that Co is mainly deposited in a reduced 2 + state. While optimization of the fast-charging protocol mitigates Li plating on the anode, no significant difference in the amount of deposited Co can be observed between an optimized and a nonoptimized fast-charging algorithm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A mid-scale plasma-electrode Pockels cell for the FLUX laser

A mid-scale (270 x 270-mm aperture) plasma-electrode Pockels cell (PEPC) has been developed for the pump laser system in FLUX (the fourth-generation laser for ultrabroadband experiments). The FLUX mid-scale PEPC is adapted from the PEPC used in the OMEGA EP beamlines (410 x 410-mm aperture), with certain dimensions scaled to reduce capacitance while maintaining key plasma characteristics. After experimental optimization of operating parameters, particularly the plasma current, <70-ns switching time with excellent (>1000:1) contrast has been demonstrated. Dependence of optical switching performance on operating conditions is explained by a plasma model.

AMICA↗