Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Self-focusing of pseudo-nondiffracting laser beams with circular symmetry in collisional plasma under two ramp density profiles

The self-focusing of zeroth-order Bessel–Gaussian beams through plasma under exponential and tangential ramp density profiles is investigated theoretically by using Wentzel–Kramers–Brillouin approximation. To examine the effect of plasma density ramp on self-focusing of the studied beams, the evolution of beam-width parameter with normalized propagation distance is reported for diverse laser beams and plasma parameters. The results reveal that stronger self-focusing is obtained with exponential ramp density profile as compared to the tangential density ramp one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Age-erosion constraints on an Early Pleistocene paleosol in Yukon, Canada, with profiles of 10 Be and 26 Al: Evidence for a significant loess cover effect on cosmogenic nuclide production rates

We report that Wounded Moose type paleosols developed on remnant deposits of Late Pliocene to Early Pleistocene [pre-Reid] Cordilleran Ice Sheet [CIS] glaciations in central Yukon, Canada. It is an important regional soil-geomorphic marker at the boundary between early CIS advances and the non-glaciated regions of Yukon and Alaska. Yet, at present, its age is poorly constrained between the Reid [0.2 Ma] and earliest [2.84 Ma] CIS advances. Here, we apply depth profiles of in situ-produced cosmogenic 26 Al and 10 Be to obtain both a minimum exposure age [1.12 +0.44 / -0.36 Ma, 2σ] and maximum erosion rate [1.1 +0.9 / -0.5 m Myr -1 ] for the Wounded Moose paleosol. Here, our results show that this soil formed under exceptionally stable conditions [max erosion rate similar to polar bedrock erosion rates] and that it pre-dates the emergence of the 100 ka [eccentricity] climate cycle. Contrasting our results from single- and joint-nuclide depth profile models reveals a significant discrepancy between calculated and effective 10 Be and 26 Al production rates [40–65% of expected values]. We interpret this discrepancy as the result of intermittent loess cover—with a time-averaged depth between 60 and 110 cm—which significantly reduced apparent exposure ages obtained from the single–nuclide model. The observation of such a significant loess-cover effect on cosmogenic nuclide production has implications for exposure dating in glacial and periglacial environments; a multi-nuclide sampling strategy is required to quantify this effect.

54 ENVIRONMENTAL SCIENCES↗

Temporal expression profiling of plasma proteins reveals oxidative stress in early stages of Type 1 Diabetes progression

We report that blood markers other than islet autoantibodies are greatly needed to indicate the pancreatic beta cell destruction process as early as possible, and more accurately reflect the progression of Type 1 Diabetes Mellitus (T1D). To this end, a longitudinal proteomic profiling of human plasma using TMT-10plex-based LC-MS/MS analysis was performed to track temporal proteomic changes of T1D patients (n = 11) across 9 serial time points, spanning the period of T1D natural progression, in comparison with those of the matching healthy controls (n = 10). To our knowledge, the current study represents the largest (> 2000 proteins measured) longitudinal expression profiles of human plasma proteome in T1D research. By applying statistical trend analysis on the temporal expression patterns between T1D and controls, and Benjamini-Hochberg procedure for multiple-testing correction, 13 protein groups were regarded as having statistically significant differences during the entire follow-up period. Moreover, 16 protein groups, which play pivotal roles in response to oxidative stress, have consistently abnormal expression trend before seroconversion to islet autoimmunity. Importantly, the expression trends of two key reactive oxygen species-decomposing enzymes, Catalase and Superoxide dismutase were verified independently by ELISA.

59 BASIC BIOLOGICAL SCIENCES↗

Transverse profile of the electron beam for the RHIC electron lenses

To compensate for the beam-beam effects from the proton-proton interactions at the two interaction points IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC), we are constructing two electron lenses (e-lenses) that we plan to install in the interaction region IR10. Before installing them, the electron gun, collector, instrumentation were tested and the electron beam properties were qualified on an electron lens test bench. We will present the test results and discuss our measurement of the electron beam current and of the electron gun perveance. We achieved a maximum current of 1 A with 5 kV energy for both the pulsed- and the DC-beam (which is a long turn-by-turn pulse beam). We measured beam transverse profiles with an Yttrium Aluminum Garnet (YAG) screen and pinhole detector, and compared those to simulated beam profiles. Measurements of the pulsed electron beam stability were obtained by measuring the modulator voltage.

43 PARTICLE ACCELERATORS↗

An Integral Activity-Based Protein Profiling Method for Higher Throughput Determination of Protein Target Sensitivity to Small Molecules

Activity-based protein profiling (ABPP) is a chemoproteomic technique that uses small molecule probes to label active enzymes selectively and covalently in complex proteomes. Competitive ABPP, which involves treatment of the active proteome with an analyte of interest, is especially powerful for profiling how small molecules impact specific protein activities. Advances in higher throughput workflows have made it possible to generate extensive competitive ABPP data across diverse biological samples, making this approach highly appealing for characterizing shared and unique proteins affected by perturbations such as drug or chemical exposures. To use the competitive ABPP approach effectively to understand potential adverse effects of chemicals of concern (CoC), a wide range of concentrations may be needed, particularly for chemicals that lack potency or toxicity data. In this work, we present an integral competitive ABPP method that enables target sensitivity determination for different organophosphate (OP) pesticides as model toxicants. Using previously developed OP-ABPs, we optimized conditions for tandem mass tag (TMT) multiplexing of ABPP samples and compared conventional competitive ABPP involving samples at discrete paraoxon concentrations to pooled samples across that same concentration range. We then expanded our approach to compare protein target sensitivities toward two additional OP pesticides, chlorpyrifos oxon and malaoxon. The results showed that differences in integral intensities for the pooled competition sample can be used to evaluate the relative sensitivity of specific proteins without increasing the overall number of samples. For 8 CoC concentrations of interest, this strategy reduced the number of TMT plexes and the corresponding number of LC–MS/MS analyses 3-fold. In conclusion, we envision the integral ABPP (IABPP) method will provide a means to screen diverse chemicals more rapidly to identify both high and low sensitivity protein targets.

activity-based probes↗

A Satellite-Based Estimate of Convective Vertical Velocity and Convective Mass Flux: Global Survey and Comparison with Radar Wind Profiler Observations

Convective vertical velocity (w c ) and convective mass flux (M c ) lie at the heart of GCM cumulus parameterizations, but few observations of these critical parameters are available. In this paper, we develop and evaluate a novel, satellite-based method for estimating profiles of w c and M c . Here, comparisons with collocated ground-based radar wind profiler (RWP) observations show that satellite estimated median w c is slightly greater than the RWP estimates, but they show solid agreement when compared at the 95th percentiles (intense updrafts). RWP-derived and satellite estimated M c are broadly comparable in the lower and middle troposphere, with some differences in the upper troposphere due to differences in convective core sampling. A k-means cluster analysis of multiple years of w c data shows that convective characteristics are distinctly different among extratropical convection, tropical land convection, and tropical oceanic convection. Tropical land convection is significantly more intense and more variable than the oceanic counterpart.

54 ENVIRONMENTAL SCIENCES↗

Direct high-resolution ion beam-profile imaging using a position-sensitive Faraday cup array

Ion sources have wide-spread use in a multitude of applications. For many, an accurate knowledge, or better, an accurate imaging, of the beam profile and intensity is an important criterion. We are developing an ion source to calibrate instruments for space-based measurements of solar wind and suprathermal particles in the energy range from below 1 keV/nuc to above 200 keV/nuc. In order to establish accurate beam profiles for calibration purposes, we have developed a new method based on an array of very small (diameter = 0.3 mm) Faraday cups. Here, we describe the experimental setup and discuss how to achieve several requirements such as a large thermal load due to the {approx}40W of beam power.

43 PARTICLE ACCELERATORS↗

Development of a Negative Hydrogen Ion Source for Spatial Beam Profile Measurement of a High Intensity Positive Ion Beam

We have been developing a negative hydrogen ion (H{sup -} ion) source for a spatial beam profile monitor of a high intensity positive ion beam as a new diagnostic tool. In case of a high intensity continuous-wave (CW) deuteron (D{sup +}) beam for the International Fusion Materials Irradiation Facility (IFMIF), it is difficult to measure the beam qualities in the severe high radiation environment during about one-year cyclic operation period. Conventional techniques are next to unusable for diagnostics in the operation period of about eleven months and for maintenance in the one-month shutdown period. Therefore, we have proposed an active beam probe system by using a negative ion beam and started an experimental study for the proof-of-principle (PoP) of the new spatial beam profile monitoring tool. In this paper, we present the status of development of the H{sup -} ion source as a probe beam source for the PoP experiment.

43 PARTICLE ACCELERATORS↗

Parallel transport of long mean-free-path plasmas along open magnetic field lines: Plasma profile variation

Parallel transport of long mean-free-path plasma along an open magnetic field line is characterized by strong temperature anisotropy, which is driven by two effects. The first is magnetic moment conservation in a non-uniform magnetic field, which can transfer energy between parallel and perpendicular degrees of freedom. The second is decompressional cooling of the parallel temperature due to parallel flow acceleration by conventional presheath electric field which is associated with the sheath condition near the wall surface where the open magnetic field line intercepts the discharge chamber. To the leading order in gyroradius to system gradient length scale expansion, the parallel transport can be understood via the Chew-Goldbeger-Low (CGL) model which retains two components of the parallel heat flux, i.e., q{sub n} associated with the parallel thermal energy and q{sub s} related to perpendicular thermal energy. It is shown that in addition to the effect of magnetic field strength (B) modulation, the two components (q{sub n} and q{sub s}) of the parallel heat flux play decisive roles in the parallel variation of the plasma profile, which includes the plasma density (n), parallel flow (u), parallel and perpendicular temperatures (T{sub Parallel-To} and T{sub Up-Tack }), and the ambipolar potential ({phi}). Both their profile (q{sub n}/B and q{sub s}/B{sup 2}) and the upstream values of the ratio of the conductive and convective thermal flux (q{sub n}/nuT{sub Parallel-To} and q{sub s}/nuT{sub Up-Tack }) provide the controlling physics, in addition to B modulation. The physics described by the CGL model are contrasted with those of the double-adiabatic laws and further elucidated by comparison with the first-principles kinetic simulation for a specific but representative flux expander case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Start-to-end beam dynamics simulation of double triangular current profile generation in Argonne Wakefield Accelerator

Double triangular current profile (DT) gives a high transformer ratio which is the determining factor of the performance of collinear wakefield accelerator. This current profile can be generated using the emittance exchange (EEX) beam line. Argonne Wakefield Accelerator (AWA) facility plans to generate DT using the EEX beam line. We conducted start-to-end simulation for the AWA beam line using PARMELA code. Also, we discuss requirements of beam parameters for the generation of DT.

43 PARTICLE ACCELERATORS↗

Turbulent energy exchange: Calculation and relevance for profile prediction

The anomalous heat production due to turbulence is neither routinely calculated in nonlinear gyrokinetic simulations nor routinely retained in profile prediction studies. In this work, we develop a symmetrized method to compute the exchange which dramatically reduces the intermittency in the time-dependent moment, thereby improving the accuracy of the time-average. We also examine the practical impact on transport-timescale simulations, and show that the exchange has only a minor impact on profile evolution for a well-studied DIII-D discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of the resistivity profile on the formation of a reversed configuration and single helicity states in compressible simulations of the reversed-field pinch

Compressible magnetohydrodynamics simulations of the reversed-field pinch (RFP) are presented. Previous simulations of the RFP, including density and pressure evolution, showed that a stationary state with a reversed toroidal magnetic field could not be obtained, contrary to the results produced with numerical codes neglecting density and pressure dynamics. The simulations described in the present paper show that including density and pressure evolution, a stationary RFP configuration can be obtained if the resistivity has a radial profile steeply increasing close to the wall. Such resistivity profile is more realistic than a uniform resistivity, since the temperature at the wall is lower than in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A real-time intercepting beam-profile monitor for a medical cyclotron

There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

43 PARTICLE ACCELERATORS↗

A simple algorithm for beam profile diagnostics using a thermographic camera

A new algorithm for digital image processing apparatuses is developed to evaluate profiles of high-intensity DC beams from temperature images of irradiated thin foils. Numerical analyses are performed to examine the reliability of the algorithm. To simulate the temperature images acquired by a thermographic camera, temperature distributions are numerically calculated for 20 MeV proton beams with different parameters. Noise in the temperature images which is added by the camera sensor is also simulated to account for its effect. Using the algorithm, beam profiles are evaluated from the simulated temperature images and compared with exact solutions. We find that niobium is an appropriate material for the thin foil used in the diagnostic system. We also confirm that the algorithm is adaptable over a wide beam current range of 0.11–214 μA, even when employing a general-purpose thermographic camera with rather high noise (ΔT{sub NETD} ≃ 0.3 K; NETD: noise equivalent temperature difference)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-invasive beam profile monitor for charged particle beams

Non-interceptive beam profile monitors are highly desirable in almost all particle accelerators. Such techniques are especially valuable in applications where real time monitoring of the beam properties is required while beam preservation and minimal influence on the vacuum are of the greatest importance. This applies to many kinds of accelerators such as high energy machines where the normal diagnostics cannot withstand the beam's power, medical machines where treatment time is valuable and cannot be allocated to diagnostics and also low energy, low intensity accelerators where the beam's properties are difficult to measure. This paper presents the design of a gas-jet based beam profile monitor which was developed and commissioned at the Cockcroft Institute and can operate in a very large background pressure range from 10{sup −7} down to below 10{sup −11} millibars. The functioning principle of the monitor is described and the first experimental results obtained using a 5 keV electron beam are discussed.

43 PARTICLE ACCELERATORS↗

Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method to estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New x-ray pink-beam profile monitor system for the SPring-8 beamline front-end

A new beam profile monitoring system for the small X-ray beam exiting from the SPring-8 front-end was developed and tested at BL13XU. This system is intended as a screen monitor and also as a position monitor even at beam currents of 100 mA by using photoluminescence of a chemical vapor deposition-grown diamond film. To cope with the challenge that the spatial distribution of the photoluminescence in the vertical direction is too flat to detect the beam centroid within a limited narrow aperture, a filter was installed that absorbs the fundamental harmonic concentrated in the beam center, which resulted in “de-flattening” of the vertical distribution. For the measurement, the filter crossed the photon beam vertically at high speed to withstand the intense heat flux of the undulator pink-beam. A transient thermal analysis, which can simulate the movement of the irradiation position with time, was conducted to determine the appropriate configuration and the required moving speed of the filter to avoid accidental melting. In a demonstration experiment, the vertically separated beam profile could be successfully observed for a 0.8 × 0.8 mm{sup 2} beam shaped by an XY slit and with a fundamental energy of 18.48 keV. The vertical beam centroid could be detected with a resolution of less than 0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An online, energy-resolving beam profile detector for laser-driven proton beams

In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗