Subdrain Water Treatment Facility for Reduction of Waste Water Amount at the Fukushima NPS Site - 19318
At the Fukushima Daiichi Nuclear Power Station site, a water treatment facility dedicated to the subdrain and groundwater drain has been constructed by Tokyo Electric Power Company Holdings, Inc. and Hitachi-GE Nuclear Energy, Ltd. The facility consists of three kinds of equipment for collecting, purifying and transferring contaminated water. The purification equipment removes low concentration radionuclides, such as Cs-137 and Sr-90, contained in the pumped groundwater using adsorption vessels filled with Cs-Sr adsorbent. It is important to lower the operational cost of the facility. We have been developing a cost reduction technique to prolong the operating lifetime of the Cs-Sr adsorption vessels by improving the adsorption performance of the Cs-Sr simultaneous adsorbent. Therefore, pH adjustment for the groundwater by using granular MgO as a pH adjustment agent was investigated. The experimental and the simulation results showed that the distribution coefficient Kd with pH adjustment by MgO was evaluated as approximately 1.8 times higher than Kd without pH adjustment and the replacement timing of the Cs-Sr adsorption vessels with pH adjustment was 2 times longer than the timing without pH adjustment. From these results, we decided to include pH adjustment using MgO as the pH adjustment agent in the purification equipment in order to reduce the amount of Cs-Sr simultaneous adsorbent used and the operational cost of the facility. (authors)