Search NASA⌕ Search

SEARCH · Search NASA

Results for “Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Application of a self-consistent NEGF procedure to study the coherent transport with phase breaking scattering in low dimensional systems

We have studied Quantum Transport with dephasing in Low Dimensional systems. Here, we apply a self-consistent NEGF procedure to study the transport mechanism in low-dimensional systems with phase breaking scatterers. Under this we have determined the transmission coefficient of a very small Multi-Moded Nanowire which is under a small bias potential of few meV. We have calculated the transmission of this device first with no scatterers. Then we have introduced scatterers in the device and calculated the transmission for the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessing the utility of phase-space-localized basis functions: Exploiting direct product structure and a new basis function selection procedure

In this paper we show that it is possible to use an iterative eigensolver in conjunction with Halverson and Poirier’s symmetrized Gaussian (SG) basis [T. Halverson and B. Poirier, J. Chem. Phys. 137, 224101 (2012)] to compute accurate vibrational energy levels of molecules with as many as five atoms. This is done, without storing and manipulating large matrices, by solving a regular eigenvalue problem that makes it possible to exploit direct-product structure. These ideas are combined with a new procedure for selecting which basis functions to use. The SG basis we work with is orders of magnitude smaller than the basis made by using a classical energy criterion. We find significant convergence errors in previous calculations with SG bases. For sum-of-product Hamiltonians, SG bases large enough to compute accurate levels are orders of magnitude larger than even simple pruned bases composed of products of harmonic oscillator functions.

97 MATHEMATICS AND COMPUTING↗

Qualification of a multi-diagnostic detonator-output characterization procedure utilizing PMMA witness blocks

In this study, experiments were conducted to qualify a multi-diagnostic characterization procedure for the performance output of a detonator when fired into a poly(methyl methacrylate) (PMMA) witness block. A suite of optical diagnostics were utilized in combination to both bound the shock wave interaction state at the detonator/PMMA interface and characterize the nature of the shock wave decay in PMMA. The diagnostics included the Shock Wave Image Framing Technique (SWIFT), a photocathode tube streak camera, and photonic Doppler velocimetry (PDV). High-precision, optically clear witness blocks permitted dynamic flow visualization of the shock wave in PMMA via focused shadowgraphy. SWIFT-and streak-imaging diagnostics captured the spatiotemporally evolving shock wave, providing a two-dimensional temporally discrete image set and a one-dimensional temporally continuous image, respectively. PDV provided the temporal velocity history of the detonator output along the detonator axis. Lastly, through combination of the results obtained, a bound was able to be placed on the interface condition and a more-physical profile representing the shock wave decay in PMMA for an exploding-bridgewire detonator was achieved.

47 OTHER INSTRUMENTATION↗

Generalized Procedure for Improved Accuracy of Thermal Contact Resistance Measurements for Materials With Arbitrary Temperature-Dependent Thermal Conductivity

Thermal contact resistance (TCR) is most commonly measured using one-dimensional steady-state calorimetric techniques. In the experimental methods we utilized, a temperature gradient is applied across two contacting beams and the temperature drop at the interface is inferred from the temperature profiles of the rods that are measured at discrete points. During data analysis, thermal conductivity of the beams is typically taken to be an average value over the temperature range imposed during the experiment. Our generalized theory is presented and accounts for temperature-dependent changes in thermal conductivity. The procedure presented enables accurate measurement of TCR for contacting materials whose thermal conductivity is any arbitrary function of temperature. For example, it is shown that the standard technique yields TCR values that are about 15% below the actual value for two specific examples of copper and silicon contacts. Conversely, the generalized technique predicts TCR values that are within 1% of the actual value. The method is exact when thermal conductivity is known exactly and no other errors are introduced to the system.

42 ENGINEERING↗

The AME 2020 atomic mass evaluation (I). Evaluation of input data, and adjustment procedures*

Abstract This is the first of two articles (Part I and Part II) that presents the results of the new atomic mass evaluation, AME2020. It includes complete information on the experimental input data that were used to derive the tables of recommended values which are given in Part II. This article describes the evaluation philosophy and procedures that were implemented in the selection of specific nuclear reaction, decay and mass-spectrometric data which were used in a least-squares fit adjustment in order to determine the recommended mass values and their uncertainties. All input data, including both the accepted and rejected ones, are tabulated and compared with the adjusted values obtained from the least-squares fit analysis. Differences with the previous AME2016 evaluation are discussed and specific examples are presented for several nuclides that may be of interest to AME users.

74 ATOMIC AND MOLECULAR PHYSICS↗

Two-Step Procedure to Detect Cosmological Gravitational Wave Backgrounds with Next-Generation Terrestrial Gravitational-Wave Detectors

Cosmological gravitational-wave backgrounds are an exciting science target for next-generation ground-based detectors, as they encode invaluable information about the primordial Universe. However, any such background is expected to be obscured by the astrophysical foreground from compact-binary coalescences. We propose a novel framework to detect a cosmological gravitational-wave background in the presence of binary black holes and binary neutron star signals with next-generation ground-based detectors, including Cosmic Explorer and the Einstein Telescope. Our procedure involves first removing all the individually resolved binary black hole signals by notching them out in the time-frequency domain. Then, we perform joint Bayesian inference on the individually resolved binary neutron star signals, the unresolved binary neutron star foreground, and the cosmological background. For a flat cosmological background, we find that we can claim detection at 5⁢𝜎 level when Ω ref ≥ 2.7 × 10 −12 /$\sqrt{𝑇_{obs}/yr}$, where 𝑇 obs is the observation time (in years), which is within a factor of ≲ 2 from the sensitivity reached in the absence of these astrophysical foregrounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence procedure for efficient quantum-state tomography

I show that in tomographic experiments, the measurement of a small set of observables suffices to confirm or incrementally amend prior expectations with a high degree of confidence. To this end, I adapt the evidence procedure, an estimation technique used in classical image reconstruction, for use in quantum-state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Procedure for measuring photon and vector meson circular polarization variation with respect to the reaction plane in relativistic heavy-ion collisions

The electromagnetic (EM) eld pattern created by spectators in relativistic heavy-ion collisions plants a seed of positive (negative) magnetic helicity in the hemisphere above (below) the reaction plane. Owing to the chiral anomaly, the magnetic helicity interacts with the fermionic helicity of the collision system, and causes photons emitted in upper- and lower-hemispheres to have different preferences in the circular polarization. Similar helicity separation for massive particles, due to the global vorticity, is also possible. In this paper, we lay down a procedure to measure the variation of the circular polarization w.r.t the reaction plane in relativistic heavy-ion collisions for massless photons, as well as similar polarization patterns for vector mesons decaying into two daughters. We propose to study the yield differentially and compare the yield between upper- and lower-hemispheres in order to identify and quantify such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preparatory procedure and equipment for the European x-ray free electron laser cavity implementation

The European x-ray free electron laser is under construction at Deutsches Elektronen-Synchrotron (DESY). The electron beam energy of up to 17.5 GeV will be achieved by using superconducting accelerator technology. Final prototyping, industrialization, and new infrastructure are the actual challenges with respect to the accelerating cavities. This paper describes the preparation strategy optimized for the cavity preparation procedure in industry. For the industrial fabrication and preparation, several new hardware components have been already developed at DESY. The design and construction of a semiautomated rf-measurement machine for dumbbells and end groups are described. In a collaboration among FNAL, KEK, and DESY, an automatic cavity tuning machine has been designed and four machines are under construction. The functionality of these machines with special attention to safety aspects is described in this paper. A new high pressure rinsing system has been developed and is operational.

43 PARTICLE ACCELERATORS↗

A description of the structural determination procedures of a gap junction channel at 3.5 Å resolution

The structural determination procedures of a gap junction channel at 3.5 Å resolution are described, including the preparation of crystals, intensity data collection, data processing, phasing and structural refinement. Intercellular signalling is an essential characteristic of multicellular organisms. Gap junctions, which consist of arrays of intercellular channels, permit the exchange of ions and small molecules between adjacent cells. Here, the structural determination of a gap junction channel composed of connexin 26 (Cx26) at 3.5 Å resolution is described. During each step of the purification process, the protein was examined using electron microscopy and/or dynamic light scattering. Dehydration of the crystals improved the resolution limits. Phase refinement using multi-crystal averaging in conjunction with noncrystallographic symmetry averaging based on strictly determined noncrystallographic symmetry operators resulted in an electron-density map for model building. The amino-acid sequence of a protomer structure consisting of the amino-terminal helix, four transmembrane helices and two extracellular loops was assigned to the electron-density map. The amino-acid assignment was confirmed using six selenomethionine (SeMet) sites in the difference Fourier map of the SeMet derivative and three intramolecular disulfide bonds in the anomalous difference Fourier map of the native crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validating the Test Procedures Described in UL 1741 SA and IEEE P1547.1

This paper investigates the test procedures specified in UL 1741 SA and the upcoming revision to IEEE P1547.1. A 550 kVA photovoltaic inverter was chosen for the tests. This research reveals some of the key components to consider while doing certification tests for UL 1741 SA and IEEE P1547.1. This paper also identifies some issues requiring consideration for future releases of the standard, i.e. IEEE P1547.1.

14 SOLAR ENERGY↗

Stochastic DG Placement for Conservation Voltage Reduction Based on Multiple Replications Procedure

Conservation voltage reduction (CVR) and distributed-generation (DG) integration are popular strategies implemented by utilities to improve energy efficiency. This paper investigates the interactions between CVR and DG placement to minimize load consumption in distribution networks, while keeping the lowest voltage level within the predefined range. The optimal placement of DG units is formulated as a stochastic optimization problem considering the uncertainty of DG outputs and load consumptions. A sample average approximation algorithm-based technique is developed to solve the formulated problem effectively. A multiple replications procedure is developed to test the stability of the solution and calculate the confidence interval of the gap between the candidate solution and optimal solution. The proposed method has been applied to the IEEE 37-bus distribution test system with different scenarios. The numerical results indicate that the implementations of CVR and DG, if combined, can achieve significant energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of Fuel Properties on Gasoline Direct Injection Particulate Matter Emissions Over First 200 s of World-Harmonized Light-Duty Test Procedure Using an Engine Dynamometer and Novel “Virtual Drivetrain” Software

Abstract The influence of fuel properties on particulate matter (PM) emissions from a catalytic gasoline particulate filter (GPF) equipped gasoline direct injection (GDI) engine was investigated using novel “virtual drivetrain” software and an engine mated to an engine dynamometer. The virtual drivetrain software was developed in labview to operate the engine on an engine dynamometer as if it were in a vehicle undergoing a driving cycle. The software uses a physics-based approach to determine vehicle acceleration and speed based on engine load and a programed “shift” schedule to control engine speed. The software uses a control algorithm to modulate engine load and braking to match a calculated vehicle speed with the prescribed speed trace of the driving cycle of choice. The first 200 s of the World-harmonized Light-duty Test Procedure (WLTP) driving cycle was tested using six different fuel formulations of varying volatility, aromaticity, and ethanol concentration. The first 200 s of the WLTP was chosen as the test condition because it is the most problematic section of the driving cycle for controlling PM emissions due to the cold start and cold drive off. It was found that there was a strong correlation between aromaticity of the fuel and the engine-out PM emissions, with the highest emitting fuel producing more than double the mass emissions of the low PM production fuel. However, the post-GPF PM emissions depended greatly on the soot loading state of the GPF. The fuel with the highest engine-out PM emissions produced comparable post-GPF emissions to the lowest PM producing fuel over the driving cycle when the GPF was loaded over three cycles with the respective fuels. These results demonstrate the importance of GPF loading state when aftertreatment systems are used for PM reduction. It also shows that GPF control may be more important than fuel properties, and that regulatory compliance for PM can be achieved with proper GPF control calibration irrespective of fuel type.

Energy & Fuels↗

Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures

Purpose: In X-ray fused with MRI, previously gathered roadmap MRI volume images are overlaid on live X-ray fluoroscopy images to help guide the clinician during an interventional procedure. The incorporation of MRI data allows for the visualization of soft tissue that is poorly visualized under X-ray. The widespread clinical use of this technique will require fully automating as many components as possible. While previous use of this method has required time-consuming manual intervention to register the two modalities, in this article, the authors present a fully automatic rigid-body registration method. Methods: External fiducial markers that are visible under these two complimentary imaging modalities were used to register the X-ray images with the roadmap MR images. The method has three components: (a) The identification of the 3D locations of the markers from a full 3D MR volume, (b) the identification of the 3D locations of the markers from a small number of 2D X-ray fluoroscopy images, and (c) finding the rigid-body transformation that registers the two point sets in the two modalities. For part (a), the localization of the markers from MR data, the MR volume image was thresholded, connected voxels were segmented and labeled, and the centroids of the connected components were computed. For part (b), the X-ray projection images, produced by an image intensifier, were first corrected for distortions. Binary mask images of the markers were created from the distortion-corrected X-ray projection images by applying edge detection, pattern recognition, and image morphological operations. The markers were localized in the X-ray frame using an iterative backprojection-based method which segments voxels in the volume of interest, discards false positives based on the previously computed edge-detected projections, and calculates the locations of the true markers as the centroids of the clusters of voxels that remain. For part (c), a variant of the iterative closest point method was used to find correspondences between and register the two sets of points computed from MR and X-ray data. This knowledge of the correspondence between the two point sets was used to refine, first, the X-ray marker localization and then the total rigid-body registration between modalities. The rigid-body registration was used to overlay the roadmap MR image onto the X-ray fluoroscopy projections. Results: In 35 separate experiments, the markers were correctly registered to each other in 100% of the cases. When half the number of X-ray projections was used (10 X-ray projections instead of 20), the markers were correctly registered in all 35 experiments. The method was also successful in all 35 experiments when the number of markers was (retrospectively) halved (from 16 to 8). The target registration error was computed in a phantom experiment to be less than 2.4 mm. In two in vivo experiments, targets (interventional devices with pointlike metallic structures) inside the heart were successfully registered between the two modalities. Conclusions: The method presented can be used to automatically register a roadmap MR image to X-ray fluoroscopy using fiducial markers and as few as ten X-ray projections.

60 APPLIED LIFE SCIENCES↗

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control procedures for dynamic treatment delivery techniques involving couch motion

In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-J-01: TG142 Complied Comprehensive Commissioning and Quality Assurance Procedure for Respiratory Gating

Purpose: To develop and establish a comprehensive gating commissioning and quality assurance procedure in compliance with TG142. Methods: Quality assurance tests on three Varian LINACs included beam output and energy constancy, calibration of surrogate, as well as phase and amplitude gating temporal accuracy. A diode array (MapCHECK 2) and film (Gafchromic EBT2) were used to measure the temporal accuracy of phase and amplitude gating windows. A motion simulation device (MotionSim) was used to simulate respiratory motion for both detectors. An end-to-end test was also performed on all three machines. The overall accuracy and uncertainty was analyzed and compared. Results: The end-to-end test using an anthropomorphic lung phantom (CIRS) results in an OSL dose difference reading within 5% (within measurement uncertainty) for both phase and amplitude gated treatment. Film results showed < 1% agreement between profiles for gated delivery and predicted dose. The diode array demonstrated an 80% passing rate for gamma criteria of 2%/0.2 mm, which results in a 111 msec temporal accuracy. However, the diode array is limited by its spatial resolution of measurements, due to its 7.07 mm diode spacing. Film provided higher measuring resolution, thus demonstrated a temporal accuracy of <100 msec. Conclusion: Results showed consistent respiratory gating stability and accuracy. MapCHECK 2 may not be sufficient for the temporal accuracy test in the respiratory gating treatment in order to meet the corresponding tolerance in TG142. One would need to decrease respiratory motion speed from the surrogate or tighten the gating window in order to be within tolerance of 100 msec temporal accuracy per TG-142. The end-to-end test offers insight to the overall accuracy and uncertainties with a gated protocol. Compared to static delivery, respiratory motion increases the overall uncertainty of treatment delivery from 3% to 5% dose difference.

60 APPLIED LIFE SCIENCES↗

MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability metrics: Different cultures/practices affecting the effectiveness of methods and metrics. Show examples of quality assurance workflows, Statistical process control, that monitor the treatment planning and delivery process to identify errors. To learn to identify and prioritize risks and QA procedures in radiation oncology. Try to answer the question: Can a quality assurance program aided by quality assurance metrics help minimize errors and ensure safe treatment delivery. Should such metrics be institution specific.

07 ISOTOPE AND RADIATION SOURCES↗