Search NASA⌕ Search

SEARCH · Search NASA

Results for “R value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Detailed determination of the nuclear fusion radius by a simultaneous optical model calculation of elastic scattering and fusion cross sections in reactions involving weakly bound projectiles

Within the optical model for direct reactions, simultaneous calculations of elastic scattering, complete fusion, and total reaction cross sections for energies around the Coulomb barrier are presented for reactions involving the weakly bound projectile {sup 9}Be on {sup 64}Zn. Volume (W{sub F}) and surface (W{sub DR}) Woods-Saxon optical potentials are used such that the former is responsible only for complete fusion reactions while the latter for all direct reactions plus incomplete fusion. Simultaneous fits can be obtained with several sets of potential parameters, but if we impose the condition that the strength of W{sub F} is smaller than the strength of W{sub DR} at the tail region of the potential (this condition is discussed in detail), then values are required for r{sub F} and r{sub DR} of around 1.6 and 1.7-1.9 fm, respectively. These values are much larger than those frequently used in barrier penetration model calculations. Through the energy dependence of the real and imaginary parts of the polarization potentials, we show that the usual threshold anomaly does not show up for this system, but instead there is evidence of the presence of a breakup threshold anomaly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new model for plasma transport and chemistry at Saturn

A model of plasma transport and chemistry is described which calculates the evolution of a plasma population in latitude and radial distance. This model is applied to the magnetosphere of Saturn, where it is used to fit the density profile of the heavy ions assuming both satellite and ring sources of plasma. Use of an extended source region is found to significantly alter the resulting plasma profile. Water ions cannot fit the observed density profile inside L = 6 even with a large ring source. Oxygen ions can fit the density profile throughout the region inside L = 12 given a suitable profile of neutral hydrogen; a suitable profile contains up to 5 H/cu cm outside L = 4 with the number increasing inside this. Preferred values of K are 1-3 x 10 exp -10 R(S)2/s, but any value K less than 10 exp -9 R(S)2/s can be accommodated. The temperature profile is shown to favor models invoking in situ plasma formation and loss as opposed to models where transport is important.

Richardson, John D.↗

Rainfall erosivity in Slovenia: Sensitivity estimation and trend detection

Highlights: • Rainfall erosivity for 10 rainfall stations located in Slovenia was evaluated. • Rainfall erosivity trends are mostly positive while mostly statistically insignificant. • The maximum rainfall erosivity is obtained under Alpine climate. • Monthly rainfall erosivity was computed. • Sensitivity analyses were carried out. Slovenia is one of the EU countries with the largest values and largest amounts of variability in rainfall erosivity, with maximum annual values exceeding 10,000 MJ mm ha{sup -1} h{sup -1} yr{sup -1}. Five-minute rainfall data was analysed from 10 Slovenian rainfall stations with data-length availability longer than 25 years with a maximum data length of 69 years and a total data-station length equal to 443 years. Trends in the rainfall erosivity R-factor were detected for four different sub-samples using monthly, half-year, and annual rainfall erosivity values. The results indicate that rainfall erosivity trends for the selected Slovenian stations are mostly statistically insignificant, with the selected significance level of 0.05. However, a larger share of identified trends are positive than negative. The maximum annual rainfall erosivity values were obtained for one specific mountain station. Furthermore, a sensitivity analysis regarding the rainfall erosivity factor R calculation showed that the rainfall threshold parameter (12.7 mm) that is used to remove the small-magnitude rainfall events in order to reduce the computational burden can attribute up to 10% of the average annual R-values in cases where this threshold is not used. Other parameters have, on average, a smaller impact on the calculated rainfall erosivity. Furthermore, the application of local kinetic energy equations resulted in, on average, about 20% higher annual rainfall erosivity values compared to the equation that is proposed by the Revised Universal Soil Loss Equation (RUSLE) manual and was not developed specifically for this region.

54 ENVIRONMENTAL SCIENCES↗

Accurate and Sensitive Analytical Strategy for the Determination of Antimony: Hydrogen Assisted T-Shaped Slotted Quartz Tube-Atom Trap-Flame Atomic Absorption Spectrometry

Antimony is known to have some adverse health effects on human health. Flame atomic absorption spectrometry (FAAS) is a widely used instrumental for the determination of antimony and other metals. However, it lacks the sensitivity to determine these metals at trace levels. This study was aimed at overcoming this setback by using hydrogen assisted T-shaped slotted quartz tube technique to preconcentrate and determine antimony by FAAS. All the system parameters were optimized to enhance the detection power of the system. Under the optimum experimental conditions, the limits of detection and quantification were found to be 0.75 and 2.49 µg L{sup −1}, respectively with R{sup 2} value of 0.9999. Accuracy of the developed method was validated by experimental results agreeing to the certified value of a standard reference material. Recovery studies were also carried out to determine the method’s applicability to tap and mineral water samples, and the results obtained were appreciable.

54 ENVIRONMENTAL SCIENCES↗

Physicochemical Behavior of Penaeuse semisulcatuse Chitin for Pb and Cd Removal from Aqueous Environment

A beta type-chitin was produced from the shell of Penaeuse semisulcatuse shrimp for removal of lead and cadmium from the aqueous environment. Full physicochemical properties of the chitin (FTIR, SEM, mapping, XRD, EDX, AFM, and TGA-DTG) were obtained. Effects of solution pH, chitin dose, metals concentration, and contact time on the lead and cadmium adsorption were assessed. The solution pH had a great influence on the metal removal. Pseudo-first and pseudo-second order models were used to evaluate the kinetic behavior of metals adsorption by P. semisulcatuse chitin. Freundlich isotherm model was slightly better than the Langmuir model to describe the adsorption data. The R{sub L} value (obtained from the Langmuir model) for the adsorption of lead and cadmium was calculated to be 0.027 and 0.133, respectively, which showed the metals adsorption process by the chitin is desirable. The maximum adsorption capacity of lead and cadmium by P. semisulcatuse chitin was determined 13.14 mg/g and 19.15 mg/g, respectively. To desorb the adsorbed-metal from the chitin, the 1M HNO{sub 3} solution was applied and the heavy metals desorption was suitable (90%). The half life (t{sub 1/2}) factor in the adsorption of Pb and Cd onto chitin was calculated 2.817 min and 3.876 min, respectively.

54 ENVIRONMENTAL SCIENCES↗

Adsorption of Nickel Ion in Aqueous Using Rubber-Based Hydrogel

This work reports about a rubber-based hydrogel from liquid natural rubber (LNR) and acrylic acid (AAc) by using potassium persulfate (KPS) as an initiator and N,N-methylenebisacrylamide (MBA) as a crosslinking agent. The structure, stability, and morphology of the hydrogel were confirmed by using Fourier transform infrared spectroscopy, thermogravimetric analysis, and scanning electron microscope. The optimisation of the swelling capacity and Ni{sup 2+} removal percentage by the rubber-based hydrogel was conducted by using 5-level-2-factor response surface methodology. The effect of AAc:LNR ratio (0.59–3.41 g/g) and MBA concentration (0.02–0.23 M) parameters was studied with constant KPS concentration (0.05 M) used. Quadratic models for both responses (swelling and Ni{sup 2+} removal percentage) were successfully developed by using statistical analysis. The swelling degree and Ni{sup 2+} removal percentage of hydrogel were improved when high AAc:LNR ratio and lower MBA concentration were used. The R{sup 2} values for these quadratic models were 0.9891 and 0.9939 (swelling and Ni{sup 2+} removal percentage), respectively, which showed that the models were well-fitted with the experimental data. From the analysis, the optimum conditions for maximum swelling capacity (1181.90%) and Ni{sup 2+} removal percentage (26.74%) were hydrogel with AAc:LNR ratio 3.00 g/g and 0.05 M of MBA.

36 MATERIALS SCIENCE↗

The Influence of Fabrication Methods on Structure and Microwave Absorption Property of Fe{sub 3}O{sub 4}/rGO Composites

In this study, flake graphite is used as raw material and oxidized to produce graphene oxide (GO), and then two kinds of ferroferric oxide/reduced graphene oxide (Fe{sub 3}O{sub 4}/rGO) composites are fabricated with one-step and two-step methods, respectively. The influence of composite methods on structure and performance is investigated by FT-IR, XRD, SEM, TEM, and testing of electromagnetic parameters. The results show that there are many advantages in the one-step method for fabrication of Fe{sub 3}O{sub 4}/rGO composite, such as the composite process is simplified, the time is shortened, and the Fe{sub 3}O{sub 4}/rGO composite fabricated with the one-step method has the best microwave impedance matching property in the frequency range of 2.5–6 GHz. At the same time, it can be found that there is the Fe–O–C bond in Fe{sub 3}O{sub 4}/rGO composites fabricated with the one-step method, which results in two ways of physical recombination and chemical bonding between Fe{sub 3}O{sub 4} and rGO sheet particulates. In addition, when the mass ratio of GO and FeCl{sub 3} is 1:10, the R{sub L} value of the Fe{sub 3}O{sub 4}/rGO composite fabricated with the one-step method is minimum, and the increase of sample thickness is beneficial to improve the impedance matching property of Fe{sub 3}O{sub 4}/rGO composite in the frequency range of 2.5–6 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Modified Johnson–Cook Model for Flow Behavior of Alloy 800H at Intermediate Strain Rates and High Temperatures

A modified Johnson–Cook model for the flow behavior of alloy 800H at intermediate strain rates and high temperatures is presented. The modification is based on a study of the relation between strain hardening and both strain rate and softening parameters. The predicted stresses obtained using the modified model are compared to those obtained using the original Johnson–Cook model. The parameters constitute the two models are determined using the inverse method, Kalman filter. The results show that the modified model fits the experimental data very well for different combinations of strain rates and temperatures, with a mean value of R-squared regression of 0.90 for the modified model and 0.74 for the original Johnson–Cook model.

36 MATERIALS SCIENCE↗

Effect of Sm-Rich Phase on Corrosion Behavior of Hot-Extruded AZ31-1.5Sm Magnesium Alloy

The effects of Sm on the corrosion and microstructure behavior of hot-extruded AZ31 magnesium alloy were investigated by SEM, TEM, weight loss analysis, and electrochemical measurements. The results indicated that granular Al{sub 2}Sm phase ~ 4 μm in size in the hot-extruded AZ31 magnesium alloy modified with 1.5 wt.% Sm leads to significant grain refinement. The corrosion rate decreased from 15.98 × 10{sup −4} to 11.19 × 10{sup −4} g cm{sup −2} h{sup −1} in the transverse section and from 8.57 × 10{sup −4} to 6.20 × 10{sup −4} g cm{sup −2} h{sup −1} in the longitudinal section. Compared to the unmodified alloy, the corrosion potential of the Sm-modified alloy in the transverse and longitudinal sections increased by 98 and 62 mV, respectively, and the R{sub ct} value (charge transfer resistance) in the transverse and longitudinal sections of the modified alloy increased from 1764 and 1756 to 2928 and 2408 Ω cm{sup 2}, respectively. The results showed that the corrosion resistance of hot-extruded AZ31 magnesium alloy was significantly improved by Sm addition due to the grain refinement, the decreased dislocation density, and the suppression of micro-galvanic corrosion caused by Al-Sm-(Mn) intermetallic compounds.

36 MATERIALS SCIENCE↗

Protective Performance of Plasma-Enhanced Chemical Vapor-Deposited Ethyl Cyclohexane Coating on Magnesium Alloys

In the present investigation, plasma-polymerized ethyl cyclohexane (ECH) coatings were deposited onto AZ31 and AM50 magnesium (Mg) alloys using plasma-enhanced chemical vapor deposition. The influences of deposition time on the coating formation, surface morphology, chemical composition and electrochemical corrosion behavior were investigated. The coating deposition was confirmed by infrared spectroscopy (FT-IR), and the thickness was measured using a scanning electron microscope. Energy-dispersive x-ray analysis revealed an increase in carbon and a decrease in Mg concentrations as the coating duration was increased. Electrochemical impedance spectroscopy (EIS) results confirmed an improvement in the corrosion resistance of AZ31 and AM50 alloys due to ECH coatings in the presence of a 3.5 wt.% NaCl solution. Further, equivalent circuit curve fitting analysis of the EIS results indicated an increase in charge transfer resistance (R{sub ct}) values with longer coating durations. These results confirmed the protecting ability of ECH coatings against corrosive ion attack, which was also substantiated by the surface morphologies after corrosion. Impedance values decreased as the duration of exposure in a NaCl solution increased, and the coating prepared using a 30-min ECH deposition exhibited better protection properties.

36 MATERIALS SCIENCE↗

The low-temperature heat capacity and thermodynamic properties of greigite (Fe 3 S 4 )

Heat capacity measurements provide important insights into the energetic, thermodynamic, and magnetic properties of materials. Herein we report the heat capacity of greigite (Fe 3 S 4 ) from 1.8 to 300 K. Greigite is a magnetic spinel mineral and through a ferromagnetic magnon term, C fsw = B fsw T 3/2 , ferrimagnetic ordering is observed in the low-temperature heat capacity. Using a set of theoretical fits of the experimental data, we calculate the thermodynamic functions, including the standard entropy ($Δ_{0}^{T}$S m °). Greigite is important in iron sulfide formation and reaction pathways in environmental, ore-forming, and technological settings and previous work has measured enthalpies $ΔH_{r}°$ of formation and decomposition to neighboring phases. In this work, the stability of greigite relative to the elements is demonstrated with a negative Gibbs energy ($ΔG_{r}°$) of formation and the stability relative to decomposition products of pyrrhotite (FeS 1.092 ) and pyrite (FeS 2 ) is demonstrated with a positive Gibbs energy ($ΔG_{r}°$) of decomposition. Values of the standard thermodynamic functions C p,m °, $Δ_{0}^{T}$S m °, $Δ_{0}^{T}$H m °, and Φ m ° are tabulated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal structure and non-stoichiometry of cerium brannerite: Ce{sub 0.975}Ti{sub 2}O{sub 5.95}

The crystal structure of cerium brannerite, Ce{sub 0.975}Ti{sub 2}O{sub 5.95}, was determined from Rietveld analysis of high resolution neutron powder diffraction data (space group C2/m, a=9.8320(1) A, b=3.75287(6) A, c=6.8852(1) A, {beta}=119.230(1) Degree-Sign ). The presence of both cerium and oxygen vacancies was confirmed from Rietveld analysis and defect energy calculations, combined with careful investigation of the phase diagram. Formation of oxygen vacancies at the O1 site, charge compensated by Ce vacancies, relieves considerable Coulombic repulsion and hence structural strain associated with short O1-O1 contacts forming the shared edge of neighbouring TiO{sub 6} polyhedra. Consideration of the bond valence sum of Ce{sup 4+} in Ce{sub 0.975}Ti{sub 2}O{sub 5.95} afforded a revised value of the r{sub 0}=2.098{+-}0.039 A for the reference bond length, based on analysis of 21 crystal structures mined from the ICSD. - Graphical abstract: Neutron diffraction and atomistic defect energy calculations reveal the mechanism of nonstochiometry in cerium brannerite, Ce{sub 0.975}Ti{sub 2}O{sub 5.95}. Highlights: Black-Right-Pointing-Pointer The defect brannerite Ce{sub 0.975}Ti{sub 2}O{sub 5.95} was prepared by solid state synthesis. Black-Right-Pointing-Pointer Neutron diffraction confirmed the presence of Ce vacancies charge compensated by O vacancies. Black-Right-Pointing-Pointer Defect energy calculations show oxygen vacancies relieve structural strain associated with short O-O contact distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of magnetic and upconversion nanocapsules as multifunctional drug delivery system

Multifunctional hollow nanocapsules with magnetic and upconversion luminescence properties were synthesized. Hollow Fe{sub 3}O{sub 4}@SiO{sub 2} was firstly prepared by using rodlike β-FeOOH as the template followed by silica coating, calcinations and reduction. Then Fe{sub 3}O{sub 4}@SiO{sub 2}@α-NaYF{sub 4}:Yb{sup 3+},Er{sup 3+} nanocapsules (FeSiUCNP) were synthesized by the hydrothermal transformation of the Y(Yb{sup 3+}, Er{sup 3+})(OH)CO{sub 3} (YOC) deposited onto the surface of nanocapsules through a urea-assisted homogeneous precipitation method. The hollow nanocapsules with porous structure provide space and entrance for the drug molecules. Due to the outside shell of α-NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+}, the nanomaterial shows upconverting red emission upon 980 nm NIR-light excitation. Moreover, the nanocomposites with hollow magnetite core exhibit a high relaxivity with r{sub 2} value of 183 mM{sup −1} s{sup −1}, which reveal the potential as T{sub 2}-weighted contrast agents for magnetic resonance imaging (MRI). The as-prepared nanocapsules can be performed as anti-cancer drug carriers for investigation of drug loading/release properties, which demonstrated a sustained drug release pattern and a comparable cytotoxicity with free doxorubicin (DOX). The multifunctional nanocapsules incorporated upconverting luminescence, T{sub 2}-weighted MRI imaging and drug targeting delivery modalities have great potential for theranostic applications in cancer treatment. - Graphical abstract: Multifunctional hollow nanocapsules with upconverting luminescence, T{sub 2}-weighted MRI imaging and drug targeting delivery modalities were synthesized for cancer treatment. - Highlights: • Multifunctional porous Fe{sub 3}O{sub 4}@SiO{sub 2}@α-NaYF{sub 4}:Yb{sup 3+},Er{sup 3+} nanocapsules were synthesized. • The nanocapsules show upconverting red emission upon 980 nm NIR-light excitation. • The nanocapsules exihibit potential as T{sub 2}-weighted contrast agents for MRI. • The DOX loaded nanocapsules demonstrated a comparable cytotoxicity with free DOX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The crystal structure of eulytite Pb{sub 3}BiV{sub 3}O{sub 12}

The crystal structure of Pb{sub 3}BiV{sub 3}O{sub 12} was solved using single-crystal X-ray diffraction technique. The compound crystallizes in the cubic system I4-bar3d (No. 220) with eulytite structure with a = 10.7490(7) A, V = 1241.95(14) A{sup 3} and Z = 4. The final R{sub 1} value of 0.0198 (wR{sub 2}=0.0384) was achieved for 359 independent reflections during the structure refinement. The Pb{sup 2+} and Bi{sup 3+} cations occupy the special position (16c) while the oxygen anions occupy the general position (48e) in the crystal structure. Unlike many other eulytite compounds, all the crystallographic positions are fully occupied. The structure consists of edge-shared Pb/Bi octahedra linked at the corners to independent [VO{sub 4}]{sup 3-} tetrahedra units, generating a eulytite-type network in the crystal lattice.

36 MATERIALS SCIENCE↗

Synthesis and characterization of pharmaceutical surfactant templated mesoporous silica: Its application to controlled delivery of duloxetine

Graphical abstract: - Highlights: • Usefulness of dual pharmaceutical surfactants in silica synthesis was evaluated. • Effects of concentration of secondary template (Tween-40) were studied. • Effects of fixed solvothermal condition on mesostructure formation were studied. • Duloxetine drug loading capability was studied. • Sustained release of duloxetine was evaluated. - Abstract: A new group of mesoporous silica nanoparticles (MSNs) were synthesized using combination pharmaceutical surfactants, Triton X-100 and Tween-40 as template and loaded with duloxetine hydrochloride (DX), for improving the sustained release of DX and patterns with high drug loading. Agglomerated spherical silica MSNs were synthesized by sol–gel and solvothermal methods. The calcined and drug loaded MSNs were characterized using X-ray diffraction (XRD), Braunner–Emmett–Teller (BET), thermogravimetric analysis (TGA), Fourier-transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), differential scanning calorimetry (DSC), diffuse reflectance ultraviolet–visible (DRS-UV–vis) spectroscopy. MSNs with high surface area and pore volume were selected and studied for their DX loading and release. The selected MSNs can accommodate a maximum of 34% DX within it. About 90% was released at 200 h and hence, the synthesized MSNs were capable of engulfing DX and sustain its release. Further form the Ritger and Peppas, Higuchi model for mechanism drug release from all the MSN matrices follows anomalous transport or Non-Fickian diffusion with the ‘r’ and ‘n’ value 0.9 and 0.45 < n < 1, respectively. So, from this study it could be concluded that the MSNs synthesized using pharmaceutical templates were better choice of reservoir for the controlled delivery of drug which requires sustained release.

36 MATERIALS SCIENCE↗

Nanocrystalline immobilised ZnO photocatalyst for degradation of benzoic acid and methyl blue dye

Highlights: • ZnO thin films were successfully prepared with the help of chemical spray pyrolysis technique. • Study the effect of thickness variation(solution quantity) onto the various properties of film. • Film prepared at 1.65 μm thickness showsthe maximum photoelectrochemical performance in 0.1 M NaOH electrolyte. • The flat band potential of optimized ZnO thin film is –0.86 V/SCE. • Study degradation result of benzoic acidand methyl blue dye using ZnO photoelectrode under UV light illumination. - Abstract: ZnO thin films were deposited with different solution quantities using spray pyrolysis technique. The effect of thickness variations on photoelectrochemical (PEC), structural, morphological and optical properties are studied. PEC measurements showed maximum photo response about I{sub sc} = 0.485 mA and V{sub oc} = 632 mV at 1.65 μm film thickness. X-ray diffraction study confirms that the films are polycrystalline with hexagonal crystal structure. Hexagonal shaped grains are observed conformed from surface morphology. The estimated bandgap energy of ZnO films are varies between 3.23 to 3.29 eV. Finally large area (10 × 10 cm{sup 2}) deposited ZnO photoelectrode were used to study the photocatalytic and photoelectrocatalytic degradation of benzoic acid (BA) and methyl blue (MB) dye under UV radiation. Photoelectrocatalytic degradation result shows 65.7% degradation of BA and for colorant organic compound such as MB dye is about 98.1% is possible. The mineralization of pollutants are studied by measuring chemical oxygen demand (COD) values.

36 MATERIALS SCIENCE↗

On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery

To retrospectively evaluate quality, efficiency, and delivery accuracy of volumetric-modulated arc therapy (VMAT) plans for single-fraction treatment of thoracic vertebral metastases using image-guided stereotactic body radiosurgery (SBRS) after RTOG 0631 dosimetric compliance criteria. After obtaining credentialing for MD Anderson spine phantom irradiation validation, 10 previously treated patients with thoracic vertebral metastases with noncoplanar hybrid arcs using 1 to 2 3D-conformal partial arcs plus 7 to 9 intensity-modulated radiation therapy beams were retrospectively re-optimized with VMAT using 3 full coplanar arcs. Tumors were located between T2 and T12. Contrast-enhanced T1/T2-weighted magnetic resonance images were coregistered with planning computed tomography and planning target volumes (PTV) were between 14.4 and 230.1 cc (median = 38.0 cc). Prescription dose was 16 Gy in 1 fraction with 6 MV beams at Novalis-TX linear accelerator consisting of micro multileaf collimators. Each plan was assessed for target coverage using conformality index, the conformation number, the ratio of the volume receiving 50% of the prescription dose over PTV, R50%, homogeneity index (HI), and PTV-1600 coverage per RTOG 0631 requirements. Organs-at-risk doses were evaluated for maximum doses to spinal cord (D{sub 0.03} {sub cc}, D{sub 0.35} {sub cc}), partial spinal cord (D{sub 10%}), esophagus (D{sub 0.03} {sub cc} and D{sub 5} {sub cc}), heart (D{sub 0.03} {sub cc} and D{sub 15} {sub cc}), and lung (V{sub 5}, V{sub 10}, and maximum dose to 1000 cc of lung). Dose delivery efficiency and accuracy of each VMAT-SBRS plan were assessed using quality assurance (QA) plan on MapCHECK device. Total beam-on time was recorded during QA procedure, and a clinical gamma index (2%/2 mm and 3%/3 mm) was used to compare agreement between planned and measured doses. All 10 VMAT-SBRS plans met RTOG 0631 dosimetric requirements for PTV coverage. The plans demonstrated highly conformal and homogenous coverage of the vertebral PTV with mean HI, conformality index, conformation number, and R{sub 50%} values of 0.13 ± 0.03 (range: 0.09 to 0.18), 1.03 ± 0.04 (range: 0.98 to 1.09), 0.81 ± 0.06 (range: 0.72 to 0.89), and 4.2 ± 0.94 (range: 2.7 to 5.4), respectively. All 10 patients met protocol guidelines with maximum dose to spinal cord (average: 8.83 ± 1.9 Gy, range: 5.9 to 10.9 Gy); dose to 0.35 cc of spinal cord (average: 7.62 ± 1.7 Gy, range: 5.4 to 9.6 Gy); and dose to 10% of partial spinal cord (average 6.31 ± 1.5 Gy, range: 3.5 to 8.5 Gy) less than 14, 10, and 10 Gy, respectively. For all 10 patients, the maximum dose to esophagus (average: 9.41 ± 4.3 Gy, range: 1.5 to 14.9 Gy) and dose to 5 cc of esophagus (average: 7.43 ± 3.8 Gy, range: 1.1 to 11.8 Gy) were kept less than protocol requirements 16 Gy and 11.9 Gy, respectively. In a similar manner, all 10 patients met protocol compliance criteria with maximum dose to heart (average: 4.62 ± 3.5 Gy, range: 1.3 to 10.2 Gy) and dose to 15 cc of heart (average: 2.23 ± 1.8 Gy, range: 0.3 to 5.6 Gy) less than 22 and 16 Gy, respectively. The dose to the lung was retained much lower than protocol guidelines for all 10 patients. The total number of monitor units was, on average, 6919 ± 1187. The average beam-on time was 11.5 ± 2.0 minutes. The VMAT plans demonstrated dose delivery accuracy of 95.8 ± 0.7%, on average, for clinical gamma passing rate with 2%/2 mm criteria and 98.3 ± 0.8%, on average, with 3%/3 mm criteria. All VMAT-SBRS plans were considered clinically acceptable per RTOG 0631 dosimetric compliance criteria. VMAT planning provided highly conformal and homogenous dose distributions for the lower-dose vertebral PTV and the spinal cord as well as organs-at-risk such as esophagus, heart, and lung. Higher QA pass rates and shorter beam-on time suggest that VMAT-SBRS is a clinically feasible, fast, and effective treatment option for patients with thoracic vertebral metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and performance of a large area neutron sensitive anger camera

We describe the design and performance of a 157mm x 157mm two dimensional neutron detector. The detector uses the Anger principle to determine the position of neutrons. We have verified FWHM resolution of < 1.2mm with distortion < 0.5mm on over 50 installed Anger Cameras. The performance of the detector is limited by the light yield of the scintillator, and it is estimated that the resolution of the current detector could be doubled with a brighter scintillator. Data collected from small (<1mm 3 ) single crystal reference samples at the single crystal instrument TOPAZ provide results with low R w (F) values

42 ENGINEERING↗