Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real Time Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

SU-G-BRA-17: Tracking Multiple Targets with Independent Motion in Real-Time Using a Multi-Leaf Collimator

Purpose: Multiple targets with large intrafraction independent motion are often involved in advanced prostate, lung, abdominal, and head and neck cancer radiotherapy. Current standard of care treats these with the originally planned fields, jeopardizing the treatment outcomes. A real-time multi-leaf collimator (MLC) tracking method has been developed to address this problem for the first time. This study evaluates the geometric uncertainty of the multi-target tracking method. Methods: Four treatment scenarios are simulated based on a prostate IMAT plan to treat a moving prostate target and static pelvic node target: 1) real-time multi-target MLC tracking; 2) real-time prostate-only MLC tracking; 3) correcting for prostate interfraction motion at setup only; and 4) no motion correction. The geometric uncertainty of the treatment is assessed by the sum of the erroneously underexposed target area and overexposed healthy tissue areas for each individual target. Two patient-measured prostate trajectories of average 2 and 5 mm motion magnitude are used for simulations. Results: Real-time multi-target tracking accumulates the least uncertainty overall. As expected, it covers the static nodes similarly well as no motion correction treatment and covers the moving prostate similarly well as the real-time prostate-only tracking. Multi-target tracking reduces >90% of uncertainty for the static nodal target compared to the real-time prostate-only tracking or interfraction motion correction. For prostate target, depending on the motion trajectory which affects the uncertainty due to leaf-fitting, multi-target tracking may or may not perform better than correcting for interfraction prostate motion by shifting patient at setup, but it reduces ∼50% of uncertainty compared to no motion correction. Conclusion: The developed real-time multi-target MLC tracking can adapt for the independently moving targets better than other available treatment adaptations. This will enable PTV margin reduction to minimize health tissue toxicity while remain tumor coverage when treating advanced disease with independently moving targets involved. The authors acknowledge funding support from the Australian NHMRC Australia Fellowship and NHMRC Project Grant No. APP1042375.

60 APPLIED LIFE SCIENCES↗

Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model

PurposeTo investigate the potential of real-time magnetic particle imaging (MPI) to guide percutaneous transluminal angioplasty (PTA) of vascular stenoses in a phantom model.Materials and MethodsExperiments were conducted on a custom-built MPI scanner. Vascular stenosis phantoms consisted of polyvinyl chloride tubes (inner diameter 8 mm) prepared with a centrally aligned cable tie to form ~ 50% stenoses. MPI angiography for visualization of stenoses was performed using the superparamagnetic iron oxide nanoparticle-based contrast agent Ferucarbotran (10 mmol (Fe)/l). Balloon catheters and guidewires for PTA were visualized using custom-made lacquer markers based on Ferucarbotran. Stenosis dilation (n = 3) was performed by manually inflating the PTA balloon with diluted Ferucarbotran. An online reconstruction framework was implemented for real-time imaging with very short latency time.ResultsVisualization of stenosis phantoms and guidance of interventional instruments in real-time (4 frames/s, ~ 100 ms latency time) was possible using an online reconstruction algorithm. Labeling of guidewires and balloon catheters allowed for precise visualization of instrument positions.ConclusionReal-time MPI-guided PTA in a phantom model is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Augmented Lagrangian Filter Method for Real-Time Embedded Optimization

We present a filter line-search algorithm for nonconvex continuous optimization that combines an augmented Lagrangian function and a constraint violation metric to accept and reject steps. The approach is motivated by real-time optimization applications that need to be executed on embedded computing platforms with limited memory and processor speeds. The proposed method enables primal–dual regularization of the linear algebra system that in turn permits the use of solution strategies with lower computing overheads. We prove that the proposed algorithm is globally convergent and we demonstrate the developments using a nonconvex real-time optimization application for a building heating, ventilation, and air conditioning system. Our numerical tests are performed on a standard processor and on an embedded platform. Lastly, we demonstrate that the approach reduces solution times by a factor of over 1000.

97 MATHEMATICS AND COMPUTING↗

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]↗

NUMERICAL MODELING OF A SOLID OXIDE FUEL CELL FOR USE IN REAL-TIME SIMULATION AND CYBER-PHYSICAL SYSTEMS

Cyber-physical systems provide a mechanism with which to investigate the physical phenomena and behavior of traditionally cost-prohibitive or otherwise fragile equipment. For the National Energy Technology Laboratory (NETL), this approach resulted in the Hybrid Performance (Hyper) facility which features a gas turbine-SOFC hybrid cycle utilizing real turbomachinery and a simulated SOFC stack. This allows for the investigation of combined cycle performance and control strategies, in an exhaustive manner, both without fear of destroying delicate state-of-the-art fuel cells, and with the full accuracy of real-world turbomachinery. Issues arose between the transient response of the SOFC model being limited to a sample time of 80 milliseconds, due to the calculation time of the SOFC model taking on average 40 milliseconds to calculate for a given timestep with spikes in calculation time reaching the 80 millisecond threshold. In order to be able to match the speed of transients from the turbomachinery and likewise better discern transient behavior, it was determined that the SOFC model must be optimized to operate at a sample time of 5 milliseconds. Therefore, it is necessary to optimize the SOFC model in order to decrease the calculation time from around 40 milliseconds, down to at the most 5 milliseconds. To do this, both the electrochemical algorithm and the thermal algorithm used to simulate the physical behavior of the SOFC are investigated to determine where improvements can be made. To this end the rootfinding numerical recipes of the electrochemical algorithm are investigated as the complex electrochemistry requires a highly iterative nested dual convergence loop to resolve the voltage-current relationship, and likewise the temporal discretization of the thermal algorithm is modified for the sake of higher accuracy and stability. Ultimately the new electrochemical algorithm featuring higher order rootfinding schemes proves to be efficient enough to reach the sub 5 millisecond target, signifying an order of magnitude reduction in calculation time, and when coupled with the new temporal discretization similar calculation time characteristics show that a fully implicit, higher order temporal discretization can also successfully be used if desired. Ultimately this result means that the cyber-physical simulation system can operate at higher sample rates, and resolve transient events at significantly higher resolution and fidelity.

Arias, Jesus↗

Instrument for x-ray absorption spectroscopy with in situ electrical control characterizations

We report a synchrotron-based setup capable of performing x-ray absorption spectroscopy and x-ray magnetic circular dichroism with simultaneous electrical control characterizations. The setup can enable research concerning electrical transport, element- and orbital-selective magnetization with an in situ fashion. It is a unique approach to the real-time change of spin-polarized electronic state of a material/device exhibiting magneto-electric responses. The performance of the setup was tested by probing the spin-polarized states of cobalt and oxygen of Zn{sub 1-x}Co{sub x}O dilute magnetic semiconductor under applied voltages, both at low (∼20 K) and room temperatures, and signal variations upon the change of applied voltage were clearly detected.

36 MATERIALS SCIENCE↗

CoDCon Project (Final Report)

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet, and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We were interested in assessing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project was set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio was investigated during five flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques were incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were performed in FY 2018 using a simple dissolved fuel simulant containing only U (~1 M) and Pu (~15 mM) in nitric acid (HNO 3 ; ~3 M). In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. A fifth CoDCon flowsheet test (CoDCon Run 5) was conducted in FY 2020, with the following additional objectives: (1) routing of the technetium (Tc) in the simulated dissolved fuel solution to the solvent extraction raffinate, and (2) routing of the Np in the simulated dissolved fuel solution to the U/Pu product. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu (and Np, for Run 5), then the Pu (and Np) was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product. This report presents the results of the CoDCon Run 5 test. The flowsheet tested in Run 5 was substantially different than that run in the prior tests, especially the solvent loading section of the flowsheet. Two key changes were made. First, based on the objective to extract all the Np and route it with the U/Pu product, pentavalent vanadium [V(V)] was added to the feed and scrub solutions. The purpose of the V(V) was to convert all the Np to the +6 oxidation state, which is extractable by TBP. Second, a high acid (8 M HNO 3 ) scrub was added to the flowsheet to scrub the Tc from the solvent. This was followed by a low acid scrub (0.05 M HNO 3 ) to reduce the residual HNO 3 concentration in the solvent prior to the Pu stripping step. The output from the low acid scrub was collected separately, rather than routing towards the raffinate. The modifications to the solvent loading part of the flowsheet were only partially successful. The treatment with V(V) was effective at converting the Np to Np(VI). Only 1.3% of the Np remained in the raffinate solution. However, ~40% of the Np stripped out of the solvent in the low acid scrub step; nearly 20% of the Pu also was stripped from the solvent during the low acid scrub. For further development, either modifications to the flowsheet, or concentration and recycle of the low acid stream into the

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CoSim: A Simulator for Co-Scheduling of Batch and On-Demand Jobs in HPC Datacenters

The increasing scale and complexity of scientific applications are rapidly transforming the ecosystem of tools, methods, and workflows adopted by the high-performance computing (HPC) community. Big data analytics and deep learning are gaining traction as essential components in this ecosystem in a variety of scenarios, such as, steering of experimental instruments , acceleration of high-fidelity simulations through surrogate computations, and guided ensemble searches. In this context, the batch job model traditionally adopted by the supercomputing in-frastructures needs to be complemented with support to schedule opportunistic on-demand analytics jobs, leading to the problem of efficient preemption of batch jobs with minimum loss of progress. In this paper, we design and implement a simulator, CoSim, that enables on-the-fly analysis of the trade-offs arising between delaying the start of opportunistic on-demand jobs, which leads to longer analytics latency, and loss of progress due to preemption of batch jobs, which is necessary to make room for on-demand jobs. To this end, we propose an algorithm based on dynamic programming with predictable performance and scalability that enables supercomputing infrastructure schedulers to analyze the aforementioned trade-off and take decisions in near real-time. Compared with other state-of-art approaches using traces of the Theta pre-Exascale machine, our approach is capable of finding the optimal solution, while achieving high performance and scalability.

batch job preemption↗

Advanced Safeguards Technology Demonstration at Pacific Northwest National Laboratory

The IAEA has established international safeguards standards for fissionable materials at spent fuel reprocessing plants to ensure that significant quantities of weapons-grade nuclear material are not diverted over a specified time frame. It is, therefore, necessary to confirm proper operational performance to verify facilities operate under adequate safeguard-declared conditions. This verification can be achieved by employing monitoring equipment. Online real time monitoring of the flowsheet radiochemical streams provides a unique capability to rapidly identify deviations from normal operating conditions. Flowsheet monitoring technologies being developed at PNNL include three integrated systems: Multi-Isotope Process (MIP) Monitor, spectroscopy-based monitor (UV-vis-NIR and Raman spectrometers), and Electrochemically Modulated Separations (EMS). The MIP Monitor is designed to identify off-normal conditions in process streams using gamma spectroscopy and pattern recognition software. The spectroscopic monitoring continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major cold flowsheet chemicals. EMS provides an on-line means for pre-separating and pre-concentrating elements of interest out of complex matrices prior to detection. PNNL is preparing to test these multi-parametric technologies using different samples of dissolved spent fuel and aqueous and organic phases of the PUREX and UREX flowsheets. We will report our on-going efforts with specific focus given to quantifying sensitivity of the MIP Monitor and UV-Vis and Raman spectrometers to detect minor changes in major process variables.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CoDCon Project: FY 2019 Status Report

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We are interested in establishing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project is set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio is being established through multiple flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques have been incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were successfully performed in FY 2018. In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu, then the Pu was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Real-Time Optical Imaging: Part I

Materials research is significantly assisted by information gathered from imaging. Images may be macroscopic or microscopic; different imaging techniques ranging from conventional microscopes to synchrotron tomography are selected for various research purposes and goals. While most materials imaging is performed in static environments at room temperature because of its appropriateness (or due to device limitations), simple optical imaging may transform into a powerful tool if it is dynamically captured during materials treatments, processing, or physical/chemical exposures. Real-time observations this way provide researchers with vital information on materials behaviors under controlled but various conditions. In the field of energy materials, it is not uncommon to require materials studies under high-temperature, high-pressure, and/or corrosive conditions. In gasifiers, for example, investigations of sensor alloy degradation, slag-refractory reactions, and coal agglomeration require samples to undergo severe environments where direct imaging would be difficult using conventional experimental methods. Finally, while post mortem analysis often provides critical information, interpretation may sometimes be complicated without confirming such occurrences under those conditions.

36 MATERIALS SCIENCE↗

Toward an Autonomous Workflow for Single Crystal Neutron Diffraction

The operation of the neutron facility relies heavily on beamline scientists. Some experiments can take one or two days with experts making decisions along the way. Leveraging the computing power of HPC platforms and AI advances in image analyses, here we demonstrate an autonomous workflow for the single-crystal neutron diffraction experiments. The workflow consists of three components: an inference service that provides real-time AI segmentation on the image stream from the experiments conducted at the neutron facility, a continuous integration service that launches distributed training jobs on Summit to update the AI model on newly collected images, and a frontend web service to display the AI tagged images to the expert. Ultimately, the feedback can be directly fed to the equipment at the edge in deciding the next-step experiment without requiring an expert in the loop. With the analyses of the requirements and benchmarks of the performance for each component, this effort serves as the first step toward an autonomous workflow for real-time experiment steering at ORNL neutron facilities.

Yin, Junqi↗

Implementing and Benchmarking the Locally Competitive Algorithm on the Loihi 2 Neuromorphic Processor

Neuromorphic processors have garnered considerable interest in recent years for their potential in enabling energy-efficient and high-speed computing. The Locally Competative Algorithm (LCA) has been utilized for power efficient sparse coding on neuromophic processors, including the first Loihi processor \cite{appletospikes, loihi1}. With the Loihi 2 processor enabling custom neuron models and graded spike communication, more complex implementations of LCA are possible \cite{loihi2}. We present a new implementation of LCA designed for the Loihi 2 processor and perform an initial set of benchmarks comparing it to LCA on CPU and GPU devices. In these experiments LCA on Loihi 2 is faster and orders of magnitude more efficient, while maintaining similar reconstruction quality. We find this performance improvement increases as the LCA parameters are tuned towards greater representation sparsity. Our study highlights the potential of neuromorphic processors, particularly Loihi 2, in enabling intelligent,autonomous, real-time processing on small robots, satellite where there are strict SWaP (small, lightweighr, and low-power) requirement. By demonstrating the superior performance of LCA on Loihi 2 compared to conventional computing device, our study suggests that Loihi 2 could be a valuable tool in advancing these types of applications. Overall, our study highlights the potential of neuromorphic processors for efficient and accurate data processing on resource-constrained devices.

Parpart, Gavin G.↗

Real-Time System Log Monitoring/Analytics Framework

Analyzing system logs provides useful insights for identifying system/application anomalies and helps in better usage of system resources. Nevertheless, it is simply not practical to scan through the raw log messages on a regular basis for large-scale systems. First, the sheer volume of unstructured log messages affects the readability, and secondly correlating the log messages to system events is a daunting task. These factors limit large-scale system logs primarily for generating alerts on known system events, and post-mortem diagnosis for identifying previously unknown system events that impacted the systems performance. In this paper, we describe a log monitoring framework that enables prompt analysis of system events in real-time. Our web-based framework provides a summarized view of console, netwatch, consumer, and apsched logs in real- time. The logs are parsed and processed to generate views of applications, message types, individual/group of compute nodes, and in sections of the compute platform. Also from past application runs we build a statistical profile of user/application characteristics with respect to known system events, recoverable/non-recoverable error messages and resources utilized. The web-based tool is being developed for Jaguar XT5 at the Oak Ridge Leadership Computing facility.

Oral, H Sarp↗

Progress on detection of liquid explosives using ultra-low field MRI

Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) methods are widely used in medicine, chemistry and industry. Over the past several years there has been increasing interest in performing NMR and MRI in the ultra-low field (ULF) regime, with measurement field strengths of 10-100 microTesla and pre-polarization fields of 30-50 mTesla. The real-time signal-to-noise ratio for such measurements is about 100. Our group at LANL has built and demonstrated the performance of SQUID-based ULF NMR/MRI instrumentation for classification of materials and detection of liquid explosives via their relaxation properties measured at ULF, using T{sub 1}, and T{sub 2}, and T{sub 1} frequency dispersion. We are also beginning to investigate the performance of induction coils as sensors. Here we present recent progress on the applications of ULF MR to the detection of liquid explosives, in imaging and relaxometry.

42 ENGINEERING↗

Excited-State Densities from Time-Dependent Density Functional Response Theory

While the variational principle for excited-state energies leads to a route to obtaining excited-state densities from time-dependent density functional theory, relatively little attention has been paid to the quality of the resulting densities in real space obtained with different exchange-correlation functional approximations or how nonadiabatic approximations developed for energies of states of double-excitation character perform for their densities. Here we derive an expression directly in real space for the excited-state density, which includes the case of nonadiabatic kernels and consequently is able, for the first time, to yield densities of states of double-excitation character. Under some well-defined simplifications, we compare the performance of the local-density approximation and exact-exchange approximation, which are in a sense at the opposite extremes of the fundamental functional approximations, on local and charge-transfer excitations in one-dimensional model systems and show that the dressed Time-Dependent Density Functional Theory (TDDFT) approach gives good densities of double excitations.

approximation↗

Real-time reconstruction of ground motion during small magnitude earthquakes: A pilot study

This study presents a pilot investigation into a novel method for reconstructing real-time ground motion during small magnitude earthquakes (M < 4.5), removing the need for computationally expensive source characterization and simulation processes to assess ground shaking. Small magnitude earthquakes, which occur frequently and can be modeled as point sources, provide ideal conditions for evaluating real-time reconstruction methods. Utilizing sparse observation data, the method applies the Gappy Auto-Encoder (Gappy AE) algorithm for efficient field data reconstruction. This is the first study to apply the Gappy AE algorithm to earthquake ground motion reconstruction. Numerical experiments conducted with SW4 simulations demonstrate the method’s accuracy and speed across varying seismic scenarios. The reconstruction performance is further validated using real seismic data from the Berkeley area in California, USA, demonstrating the potential for practical application of real-time earthquake data reconstruction using Gappy AE. As a pilot investigation, it lays the groundwork for future applications to larger and more complex seismic events.

58 GEOSCIENCES↗