Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Excess Galactic Molecular Absorption Toward the Radio Galaxy 3C 111

We show the combined spectral analysis of Chandra high-energy transmission grating and XMM-Newton reflection-grating spectrometer observations of the broad-line radio galaxy 3C 111. This source is known to show excess neutral absorption with respect to the one estimated from 21 cm radio surveys of atomic H i in the Galaxy. However, previous works were not able to constrain the origin of such an absorber as local to our Milky Way or intrinsic to the source (z = 0.0485). The high signal-to-noise grating spectra allow us to constrain the excess absorption as being due to intervening gas in the Milky Way, and we estimate a time-averaged total column density of N{sub H}=(7.4±0.1)×10{sup 21} cm{sup −2}, a factor of two higher than the tabulated H i value. We recommend using the total average Galactic column density estimated here when studying 3C 111. The origin of the extra Galactic absorption of N{sub H}=4.4×10{sup 21} cm{sup −2} is likely due to molecular gas associated with the Taurus molecular cloud complex toward 3C 111, which is our nearest star-forming region. We also detect a weak (EW = 16 ± 10 eV) and narrow (FWMH < 5500 km s{sup −1}, consistent with optical Hα) Fe Kα emission line at E = 6.4 keV, likely from the torus in the central regions of 3C 111, and we place an upper limit on the column density of a possible intrinsic warm absorber of N {sub H} < 2.5 × 10{sup 20} cm{sup −2}. These complexities make 3C 111 a very promising object for studying both the intrinsic properties of this active radio galaxy and the Galactic interstellar medium, if used as a background source.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAR-INFRARED SPECTROSCOPY OF TW Hya: A REVISED SPECTRAL TYPE AND COMPARISON WITH MAGNETOSPHERIC ACCRETION MODELS

We present high signal-to-noise ratio (S/N), moderate spectral resolution (R {approx} 2000-2500) near-infrared (0.8-5.0 {mu}m) spectroscopy of the nearby T Tauri star TW Hya. By comparing the spectrum and the equivalent widths of several atomic and molecular features with those for stars in the IRTF near-infrared library, we revise the spectral type to M2.5V, which is later than what is usually adopted (K7V). This implies a substantially cooler stellar temperature than previously assumed. Comparison with various pre-main-sequence models suggests that TW Hya is only {approx}3 Myr old, much younger than the usually adopted 8-10 Myr. Analysis of the relative strengths of the H lines seen in the spectrum yields estimates for the temperature and density of the emitting region of T{sub e} {>=} 7500 K and n{sub e} {approx} 10{sup 12}-10{sup 13} cm{sup -3}. The thickness of the emitting region is 10{sup 2}-10{sup 4} km and the covering fraction is f{sub *} {approx} 0.04. Our derived physical parameter values agree with the predictions of the magnetospheric accretion scenario. The highest S/N H lines have profiles that indicate multiple emission components. We derive an excess spectrum (above that of the M2.5V template) that peaks in the H band. Although our derived veiling values ({approx}0.1) agree with previous estimates, the excess spectrum does not match that of current models in which this flux is generated by an inner optically thin disk. We suggest that the excess flux spectrum instead reflects the differences in atmospheric opacity, gravity, and age between TW Hya and older, higher gravity, field M2.5 dwarfs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck 2013 results. XXIII. Isotropy and statistics of the CMB

The two fundamental assumptions of the standard cosmological model-that the initial fluctuations are statistically isotropic and Gaussian-are rigorously tested using maps of the cosmic microwave background (CMB) anisotropy from the Planck satellite. The detailed results are based on studies of four independent estimates of the CMB that are compared to simulations using a fiducial ΛCDM model and incorporating essential aspects of the Planck measurement process. Deviations from isotropy have been found and demonstrated to be robust against component separation algorithm, mask choice, and frequency dependence. Many of these anomalies were previously observed in the WMAP data, and are now confirmed at similar levels of significance (about 3σ). However, we find little evidence of non-Gaussianity, with the exception of a few statistical signatures that seem to be associated with specific anomalies. In particular, we find that the quadrupole-octopole alignment is also connected to a low observed variance in the CMB signal. A power asymmetry is now found to persist on scales corresponding to about &ell; = 600 and can be described in the low-&ell; regime by a phenomenological dipole modulation model. However, any primordial power asymmetry is strongly scale-dependent and does not extend to arbitrarily small angular scales. Finally, it is plausible that some of these features may be reflected in the angular power spectrum of the data, which shows a deficit of power on similar scales. Indeed, when the power spectra of two hemispheres defined by a preferred direction are considered separately, one shows evidence of a deficit in power, while its opposite contains oscillations between odd and even modes that may be related to the parity violation and phase correlations also detected in the data. Although these analyses represent a step forward in building an understanding of the anomalies, a satisfactory explanation based on physically motivated models is still lacking.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of multipath effects in the detection of RF-modulated x-rays

As part of the Air Force Research Laboratory’s ongoing research in particle accelerators and beams, we recently began investigating the interaction of RF-modulated x-ray beams with RF structures. Additionally, these bremsstrahlung x-rays, produced using an S-band RF electron linac and tungsten foil, were able to drive RF signals at the linac frequency and its integer harmonics in an S-band waveguide. This was interpreted as a result of secondary electron production inside the waveguide by the modulated x-ray beam and implied that the primary electron beam RF modulation was preserved, to at least some degree, through both the processes of x-ray and secondary electron production. The strength of these signals induced on the waveguide varied as the distance of the waveguide from the tungsten foil changed, with the nature of these changes suggesting the existence of an interference process resulting from multipath propagation of the modulated x-rays. Here, we report on our initial attempt to verify this multipath propagation by altering the configuration of shielding and reflective masses in the environment of the waveguide. Finally, these measurements support the existence of a multipath propagation effect and further indicate that the RF modulation of the x-rays is preserved as they undergo scattering events inside the accelerator vault.

43 PARTICLE ACCELERATORS↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

TRANSIENT LUNAR PHENOMENA: REGULARITY AND REALITY

Transient lunar phenomena (TLPs) have been reported for centuries, but their nature is largely unsettled, and even their existence as a coherent phenomenon is controversial. Nonetheless, TLP data show regularities in the observations; a key question is whether this structure is imposed by processes tied to the lunar surface, or by terrestrial atmospheric or human observer effects. I interrogate an extensive catalog of TLPs to gauge how human factors determine the distribution of TLP reports. The sample is grouped according to variables which should produce differing results if determining factors involve humans, and not reflecting phenomena tied to the lunar surface. Features dependent on human factors can then be excluded. Regardless of how the sample is split, the results are similar: {approx}50% of reports originate from near Aristarchus, {approx}16% from Plato, {approx}6% from recent, major impacts (Copernicus, Kepler, Tycho, and Aristarchus), plus several at Grimaldi. Mare Crisium produces a robust signal in some cases (however, Crisium is too large for a 'feature' as defined). TLP count consistency for these features indicates that {approx}80% of these may be real. Some commonly reported sites disappear from the robust averages, including Alphonsus, Ross D, and Gassendi. These reports begin almost exclusively after 1955, when TLPs became widely known and many more (and inexperienced) observers searched for TLPs. In a companion paper, we compare the spatial distribution of robust TLP sites to transient outgassing (seen by Apollo and Lunar Prospector instruments). To a high confidence, robust TLP sites and those of lunar outgassing correlate strongly, further arguing for the reality of TLPs.

79 ASTRONOMY AND ASTROPHYSICS↗

THE 1998 NOVEMBER 14 OCCULTATION OF GSC 0622-00345 BY SATURN. I. TECHNIQUES FOR GROUND-BASED STELLAR OCCULTATIONS

On 1998 November 14, Saturn and its rings occulted the star GSC 0622-00345. We observed atmospheric immersion with NSFCAM at the National Aeronautics and Space Administration's Infrared Telescope Facility on Mauna Kea, Hawaii. Immersion occurred at 55.{sup 0}5 S planetocentric latitude. A 2.3 {mu}m, CH{sub 4}-band filter suppressed reflected sunlight. Atmospheric emersion and ring data were not successfully obtained. We describe our observation, light curve production, and timing techniques, including improvements in aperture positioning, removal of telluric scintillation effects, and timing. Many of these techniques are known within the occultation community, but have not been described in the reviewed literature. We present a light curve whose signal-to-noise ratio per scale height is 267, among the best ground-based signals yet achieved, despite a disadvantage of up to 8 mag in the stellar flux compared to prior work.

79 ASTRONOMY AND ASTROPHYSICS↗

Versatility and Complexity: Common and Uncommon Facets of LysR-Type Transcriptional Regulators

LysR-type transcriptional regulators (LTTRs) form one of the largest families of bacterial regulators. They are widely distributed and contribute to all aspects of metabolism and physiology. Most are homotetramers, with each subunit composed of an N-terminal DNA-binding domain followed by a long helix connecting to an effector-binding domain. LTTRs typically bind DNA in the presence or absence of a small-molecule ligand (effector). In response to cellular signals, conformational changes alter DNA interactions, contact with RNA polymerase, and sometimes contact with other proteins. Many are dual-function repressor–activators, although different modes of regulation may occur at multiple promoters. This review presents an update on the molecular basis of regulation, the complexity of regulatory schemes, and applications in biotechnology and medicine. The abundance of LTTRs reflects their versatility and importance. While a single regulatory model cannot describe all family members, a comparison of similarities and differences provides a framework for future study.

59 BASIC BIOLOGICAL SCIENCES↗

The Velocity Field of Our Milky Way Outer Stellar Halo Based on DESI DR2

Using 64,000 halo K giants from the Dark Energy Spectroscopic Instrument second Data Release (DR2), we decompose the Milky Way (MW) stellar halo between 3 and 160 kpc into metal-rich (MR) and metal-poor (MP) components via a Gaussian mixture model. The two populations are nearly equal in number but chemically and kinematically distinct: MR stars occupy highly radial orbits with velocity anisotropy of β ≈ 0.94 and metallicity dispersion σ [Fe/H] ≈ 0.17 dex, without obvious dependence on distance, and are mainly contributed by Gaia-Sausage/Enceladus (GSE) debris. The MR component dominates the inner 30 kpc and reemerges beyond 50 kpc, implying GSE debris can extend to ∼70–80 kpc. MP stars exhibit a weaker radial bias of β ≈ 0.46, decreasing to −0.5 beyond 80 kpc, and with a larger metallicity dispersion of σ [Fe/H] ≈ 0.46 dex, showing signatures of multiple minor mergers. Both components exhibit net prograde rotation at ∼10–30 kpc with a stronger azimuthal signal in the MP population. The nonequilibrium motions of the outer halo (>50 kpc) are quantified with a dipole-plus-contraction velocity field. We find that the outer halo is simultaneously contracting (μ compr = −19 km s −1 , distance-independent) and subject to reflex motions (μ dipole increases from −19 to −44 km s −1 with radius), reflecting the perturbation from the Large Magellanic Cloud (LMC). We also confirm a linear dependence of mean polar velocity for the outer stellar halo on μ dipole , a direct consequence of the LMC and MW interaction. Our results provide a quantitative distance-resolved description of the MW’s last major accretion event and its ongoing response to the first infall of the LMC.

Li, Songting [Shanghai Jiao Tong University; Shang↗

Hybrid catadioptric system for advanced optical cavity velocimetry

A probe including reflector is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface by the probe and then reflected back from the surface, is Doppler shifted by the moving surface, collected into probe, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to one or more lens groups and a reflector, such as a parabolic reflector having a mirrored interior surface.

36 MATERIALS SCIENCE↗

Bragg diffraction using a 100ps 17.5 keV x-ray backlighter and the Bragg Diffraction Imager

A new diagnostic for measuring Bragg diffraction from a laser-driven crystal using a 100ps 17.5 kV x-ray backlighter source is designed and tested successfully at the Omega EP laser facility on static Mo and Ta single crystal samples using a Mo Ka backlighter. The Bragg Diffraction Imager (BDI) consists of a heavily shielded enclosure and a precisely positioned beam block, attached to the main enclosure by an Aluminum arm. Image plate is used as the x-ray detector. The diffraction lines from Mo and Ta <222> planes are clearly detected with a high signal-to-noise using the 17.5 keV and 19.6 keV characteristic lines generated by a petawatt-driven Mo foil. This technique will be applied to shock and ramp-loaded single crystals on the Omega EP laser. Pulsed x-ray diffraction of shock- and ramp-compressed materials is an exciting new technique that can give insight into the dynamic behavior of materials at ultra-high pressure not achievable by any other means to date. X-ray diffraction can be used to determine not only the phase and compression of the lattice at high pressure, but by probing the lattice compression on a timescale equal to the 3D relaxation time of the material, information about dislocation mechanics, including dislocation multiplication rate and velocity, can also be derived. Both Bragg, or reflection, and Laue, or transmission, diffraction have been developed for shock-loaded low-Z crystalline structures such as Cu, Fe, and Si using nano-second scale low-energy implosion and He-{alpha} x-ray backlighters. However, higher-Z materials require higher x-ray probe energies to penetrate the samples, such as in Laue, or probe deep enough into the target, as in the case of Bragg diffraction. Petawatt laser-generated K{alpha} x-ray backlighters have been developed for use in high-energy radiography of dense targets and other HED applications requiring picosecond-scale burst of hard x-rays. While short pulse lasers are very efficient at producing high-energy x-rays, the characteristic x-rays produced in these thin foil targets are superimposed on a broad bremsstrahlung background and can easily saturate a detector if careful diagnostic shielding and experimental geometry are not implemented. A new diagnostic has been designed to measure Bragg diffraction from laser-driven crystal targets using characteristic x-rays from a short-pulse laser backlighter on the Omega EP laser. The Bragg Diffraction Imager, or BDI, is a TIM-mounted instrument consisting of a heavily shielded enclosure made from 3/8-inch thick Heavymet (W-Fe-Ni alloy) and a precisely positioned beam bock, attached to the main enclosure by an Aluminum arm. The beam block is made of 1-inch thick, Al-coated Heavymet and serves to block the x-rays directly from the petawatt backlight, while allowing the diffraction x-rays from the crystal to pass to the enclosure. A schematic of the BDI is shown in Fig. 1a. Image plates are used as the x-ray detector and are loaded through the top of the diagnostic in an Aluminum, light-tight cartridge. The front of the enclosure can be fitted with various filters to maximize the diffraction signal-to-noise.

42 ENGINEERING↗

Vibrational Spectroscopic Monitoring of the Gelation Transition in Nafion Ionomer Dispersions

Infrared and Raman spectroscopy techniques were applied to investigate the drying and aggregation behavior of Nafion ionomer particles dispersed in aqueous solution. Gravimetric measurements aided the identification of gel-phase development within a series of time-resolved spectra that tracked transformations of a dispersion sample during solvent evaporation. A spectral band characteristic of ionomer sidechain end group vibration provided a quantitative probe of the dispersion-to-gel change. For sets of attenuated total reflection Fourier transform infrared (ATR FT-IR) spectra, adherence to Beer's law was attributed to the relatively constant refractive index in the frequency region of hydrated –SO$^{–}_{3}$ group vibrations as fluorocarbon-rich ionomer regions aggregate in forming the structural framework of membranes and thin films. Although vibrational bands associated with ionomer backbone CF 2 stretching vibrations were affected by distortion characteristic of wavelength-dependent refractive index change within a sample, the onset of band distortion signaled gel formation and coincided with ionomer mass % values just below the critical gelation point for Nafion aqueous dispersions. Similar temporal behavior was observed in confocal Raman microscopy experiments that monitored the formation of a thin ionomer film from an individual dispersion droplet. For the ATR FT-IR spectroscopy and confocal Raman microscopy techniques, intensity in the water H–O–H bending vibrational band dropped sharply at the ionomer critical gelation point and displayed a time dependence consistent with changes in water content derived from gravimetric measurements. The reported studies lay groundwork for examining the impact of dispersing solvents and above-ambient temperatures on fluorinated ionomer transformations that influence structural properties of dispersion-cast membranes and thin films.

36 MATERIALS SCIENCE↗

Testing Vpin on Big Data Response to Reflecting on the Vpin Dispute

The authors of this note are computer scientists and mathematicians from Lawrence Berkeley National Laboratory. Most of us are specialists in high-performance computing. In 2011, at the suggestion of a CFTC commissioner, we started examining the effectiveness of VPIN as a leading indicator of unusual market events such as the “Flash Crash” of 2010. The preliminary result of that work was published as a conference paper. Our work was the first to show that VPIN could generate strong signals based on trading records of individual stocks. On a number of stocks, VPIN generated strong signals more than an hour before the “Flash Crash.” This lead-time could be valuable for market makers, regulators and traders in general. To further test the effectiveness of VPIN, we recently expanded our tests to a much larger set of test data, including the trading records of the 94 most liquid futures contracts from beginning of 2007 to middle of 2012. We set out to verify the following hypothesis: the volatility of trading is higher than the average in a time window (we call the event horizon) after VPIN value crosses a threshold. Our work carefully examined the parameters controlling the computation of VPIN as well as the event horizon and the VPIN threshold. In this largest-ever study of a leading indicator based on market microstructure, we examined 16,000 combinations of these parameters, and found that the average false positive rate can be reduced to 7%.

97 MATHEMATICS AND COMPUTING↗

Invited Article: Deep Impact instrument calibration

Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [{approx}1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of {approx}9 pixels. The charge coupled device (CCD) read noise is {approx}1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to {approx}1%. Spectrometer read noise is {approx}2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to {approx}10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of {approx}2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to {approx}0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo code G3sim for simulation of plastic scintillator detectors with wavelength shifter fiber readout

A detailed description of a compact Monte Carlo simulation code ''G3sim'' for studying the performance of a plastic scintillator detector with wavelength shifter (WLS) fiber readout is presented. G3sim was developed for optimizing the design of new scintillator detectors used in the GRAPES-3 extensive air shower experiment. Propagation of the blue photons produced by the passage of relativistic charged particles in the scintillator is treated by incorporating the absorption, total internal, and diffuse reflections. Capture of blue photons by the WLS fibers and subsequent re-emission of longer wavelength green photons is appropriately treated. The trapping and propagation of green photons inside the WLS fiber is treated using the laws of optics for meridional and skew rays. Propagation time of each photon is taken into account for the generation of the electrical signal at the photomultiplier. A comparison of the results from G3sim with the performance of a prototype scintillator detector showed an excellent agreement between the simulated and measured properties. The simulation results can be parametrized in terms of exponential functions providing a deeper insight into the functioning of these versatile detectors. G3sim can be used to aid the design and optimize the performance of scintillator detectors prior to actual fabrication that may result in a considerable saving of time, labor, and money spent.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-Based Reconstruction for Multi-Frequency Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a technology for imaging inside multi-layered structures such as geothermal wells. These systems work by using a collimated narrow-band ultrasound transmitter that can penetrate through multiple layers of heterogeneous material. A series of measurements can then be made at multiple transmit frequencies. However, commonly used reconstruction algorithms such as Synthetic Aperture Focusing Technique (SAFT) tend to produce poor quality reconstructions for these systems both because they do not model collimated beam systems and they do not jointly reconstruct the multiple frequencies. Here, in this article, we propose a multi-frequency ultrasound model-based iterative reconstruction (UMBIR) algorithm designed for multi-frequency collimated beam ultrasound systems. The combined system targets reflective imaging of heterogeneous, multi-layered structures. For each transmitted frequency band, we introduce a physics-based forward model to accurately account for the propagation of the collimated narrow-band ultrasonic beam through the multi-layered media. We then show how the joint multi-frequency UMBIR reconstruction can be computed by modeling the direct arrival signals, detector noise, and incorporating a spatially varying image prior. Results using both simulated and experimental data indicate that multi-frequency UMBIR reconstruction yields much higher reconstruction quality than either single frequency UMBIR or SAFT.

47 OTHER INSTRUMENTATION↗

Multipoint photonic doppler velocimetry using optical lens elements

A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

47 OTHER INSTRUMENTATION↗