Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIZE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Deconvolution by finite-size-source effects of x-ray phase-contrast images

Purpose: In the hard x-ray region, the cross sections for the phase shift of low-Z elements are about 1000 times larger than the absorption ones. As a consequence, phase contrast is detectable even when absorption contrast is minimal or absent. Therefore, phase-contrast imaging could become a valid alternative to absorption contrast without delivering high dose to tissue/human body parts. Methods: To enhance the quality of phase-contrast images without increasing the dose, a possible approach could be the partial deconvolution of the finite source size effects by experimental phase-contrast images. The deconvolution procedure, the authors propose, employs the acquisition of two images on a suitable well-known test sample, one in contact and the other in phase-contrast conditions. Both acquired images are used along with a simulated phase-contrast image (obtained from the test sample in ideal conditions of pointlike source illumination) to correctly retrieve the experimental source distribution function. This information allows a generic experimental phase-contrast image, acquired in the same conditions, to be partially deconvolved by finite source size effects. Results: The performed experimental tests indicate that deconvolved images are equivalent to those which would be obtained with a source 40% smaller than the actual size. In turn, this finding is equivalent to an increase of the ''effective'' lateral spatial coherence length. The corresponding quality improvement of the phase-contrast imaging is directly deducible by the presence of many Fresnel fringes, much better visible with respect to the original experimental phase-contrast images. Conclusions: The use of a test standard sample, always possible in every experimental setup, to partially deconvolve the finite-size-source blurring effects shows that higher quality phase-contrast images could be readily available, making easier diagnoses and tissue/sample analyses. The method could give, in the future, the possibility to further lower the delivered dose to patients, organs, and tissues when compact room-sized and brilliant microfocus x-ray sources will be available for clinical applications in hospitals.

60 APPLIED LIFE SCIENCES↗

Effect of jaw size in megavoltage CT on image quality and dose

Purpose: Recently, the jaw size for the TomoTherapy Hi-Art II{sup Registered-Sign} (TomoTherapy Inc., Madison, WI) was reduced from 4 mm (J4) to 1 mm (J1) to improve the longitudinal (IEC-Y) resolution in megavoltage computed tomography (MVCT) images. This study evaluated the effect of jaw size on the image quality and dose, as well as the dose delivered to the lens of the eye, which is a highly radiosensitive tissue. Methods: MVCT image quality (image noise, uniformity, contrast linearity, high-contrast resolution, and full width at half-maximum) and multiple scan average dose (MSAD) were measured at different jaw sizes. A head phantom and photoluminescence glass dosimeters (PLDs) were used to measure the exposed lens dose (cGy). Different MVCT scan modes (pitch = 1, 2, and 3) and scan lengths (108 mm, 156 mm, and 204 mm) were applied in the MSAD and PLDs measurements. Results: The change in jaw size from J4 to J1 produced no change or only a slight improvement in image noise, uniformity, contrast linearity, and high-contrast resolution. However, the full-width at half-maximum reduced from approximately 7.2 at J4 to 4.5 mm at J1, which represents an enhancement in the longitudinal resolution. The MSAD at the center point changed from approximately 0.69-2.32 cGy (peripheral: 0.83-2.49 cGy) at J4 to 0.85-2.81 cGy (peripheral: 1.05-2.86 cGy) at J1. The measured lens dose increased from 0.92-3.36 cGy at J4 to 1.06-3.91 cGy at J1. Conclusions: The change in jaw size improved longitudinal resolution. The MVCT imaging dose of approximately 3.86 cGy, 1.92 cGy, and 1.22 cGy was delivered at a pitch of 1, 2, and 3, respectively, per fraction in the head and neck treatment plans. Therefore, allowance for an approximately 15% increase in lens dose over that with J4 should be provided with J1.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-79: Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data

Purpose: To assess internal tumor volume change through breathing cycle and associated tumor motion using the 4DCT data. Methods: Respiration induced volume change through breathing cycle and associated motion was analyzed for nine patients that were scanned during the different respiratory phases. The examined datasets were the maximum and average intensity projections (MIP and AIP) and the 10 phases of the respiratory cycle. The internal target volume (ITV) was delineated on each of the phases and the planning target volume (PTV) was then created by adding setup margins to the ITV. Tumor motion through the phases was assessed using the acquired 4DCT dataset, which was then used to determine if the margins used for the ITV creation successfully encompassed the tumor in three dimensions. Results: Results showed that GTV motion along the superior inferior axes was the largest in all the cases independent of the tumor location and/or size or the use of abdomen compression. The extent of the tumor motion was found to be connected with the size of the GTV. The smallest GTVs exhibited largest motion vector independent of the tumor location. The motion vector size varied through the phases depending on the tumor size and location and it was smallest for phases 20 and 30. The smaller the volume of the delineated GTV, the greater its volume difference through the different respiratory phases was. The average GTV volume change was largest for the phases 60 and 70. Conclusion: Even if GTV is delineated using both AIP and MIP datasets, its motion extent will exceed the used margins especially for the very small GTV volumes. When the GTV size is less than 10 cc it is recommended to use fusion of the GTVs through all the phases to create the planning ITV.

60 APPLIED LIFE SCIENCES↗

SU-E-T-611: Effective Treatment Volume of the Small Size IORT Applicators

Purpose Mobile electron linear accelerators are gaining more attention recently, providing a lower cost and simpler way to perform intraoperative treatment. However, the simplicity of the treatment process does not eliminate the need for proper attention to the technical aspects of the treatment. One of the potential pitfalls is incorrect selection of the appropriate applicator size to adequately cover the tumor bed to the prescription dose. When treating tumor beds in the pelvis, the largest applicator that fits into the pelvis is usually selected as there is concern about microscopic extension of the disease along the sidewalls of the pelvis. But when treating early stage breast tumors, there is a natural tendency to select an applicator as small as possible so as not to jeopardize cosmesis. Methods This investigation questions how much of the typical breast treatment volume gets adequate exposure and what is the correct strategy in selecting the proper applicator size. Actual data from isodose scans were analyzed. Results We found that typical treatment dose prescriptions can cover as much as 80% and as little as 20% of the nominal treatment volume depending on the applicator size and energy of the beam and whether the dose is prescribed to the 80 or 90% isodose level. Treatment volume is defined as a cylinder with diameter equal to applicator and height equal to the corresponding D80 or D90 depth. Conclusion If mobile linear accelerators are used, there can be significant amount of “cold volume” depending on the applicator size and this should be taken into account when selecting the applicator that is needed. Using too small of an applicator could result in significant under-dosing to the tissue at risk. Long-term clinical data demonstrates that selecting an adequate field size results in good ontological control as well as excellent cosmesis. Intraop Medical Corp was providing facilities and equipment for this research.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-01: Minimum Detectability Analysis for Comprehensive Sized Based Optimization of Image Quality and Radiation Dose Across CT Protocols

Purpose: This work involved a comprehensive modeling of task-based performance of CT across a wide range of protocols. The approach was used for optimization and consistency of dose and image quality within a large multi-vendor clinical facility. Methods: 150 adult protocols from the Duke University Medical Center were grouped into sub-protocols with similar acquisition characteristics. A size based image quality phantom (Duke Mercury Phantom) was imaged using these sub-protocols for a range of clinically relevant doses on two CT manufacturer platforms (Siemens, GE). The images were analyzed to extract task-based image quality metrics such as the Task Transfer Function (TTF), Noise Power Spectrum, and Az based on designer nodule task functions. The data were analyzed in terms of the detectability of a lesion size/contrast as a function of dose, patient size, and protocol. A graphical user interface (GUI) was developed to predict image quality and dose to achieve a minimum level of detectability. Results: Image quality trends with variations in dose, patient size, and lesion contrast/size were evaluated and calculated data behaved as predicted. The GUI proved effective to predict the Az values representing radiologist confidence for a targeted lesion, patient size, and dose. As an example, an abdomen pelvis exam for the GE scanner, with a task size/contrast of 5-mm/50-HU, and an Az of 0.9 requires a dose of 4.0, 8.9, and 16.9 mGy for patient diameters of 25, 30, and 35 cm, respectively. For a constant patient diameter of 30 cm, the minimum detected lesion size at those dose levels would be 8.4, 5, and 3.9 mm, respectively. Conclusion: The designed CT protocol optimization platform can be used to evaluate minimum detectability across dose levels and patient diameters. The method can be used to improve individual protocols as well as to improve protocol consistency across CT scanners.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-01: BEST IN PHYSICS (IMAGING) - Calculating SSDE From CT Exams Using Size Data Available in the DICOM Header of CT Localizer Radiographs

Purpose: To demonstrate the feasibility of using existing data stored within the DICOM header of certain CT localizer radiographs as a patient size metric for calculating CT size-specific dose estimates (SSDE). Methods: For most Siemens CT scanners, the CT localizer radiograph (topogram) contains a private DICOM field that stores an array of numbers describing AP and LAT attenuation-based measures of patient dimension. The square root of the product of the AP and LAT size data, which provides an estimate of water-equivalent-diameter (WED), was calculated retrospectively from topogram data of 20 patients who received clinically-indicated abdomen/pelvis (n=10) and chest (n=10) scans (WED-topo). In addition, slice-by-slice water-equivalent-diameter (WED-image) and effective diameter (ED-image) values were calculated from the respective image data. Using TG-204 lookup tables, size-dependent conversion factors were determined based upon WED-topo, WED-image and ED-image values. These conversion factors were used with the reported CTDIvol to calculate slice-by-slice SSDE for each method. Averaging over all slices, a single SSDE value was determined for each patient and size metric. Patientspecific SSDE and CTDIvol values were then compared with patientspecific organ doses derived from detailed Monte Carlo simulations of fixed tube current scans. Results: For abdomen/pelvis scans, the average difference between liver dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 18.70%, 8.17%, 6.84%, and 7.58%, respectively. For chest scans, the average difference between lung dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 25.80%, 3.33%, 4.11%, and 7.66%, respectively. Conclusion: SSDE calculated using WED derived from data in the DICOM header of the topogram was comparable to SSDE calculated using WED and ED derived from axial images; each of these estimated organ dose to within 10% for both abdomen/pelvis and chest CT examinations. The topogrambased method has the advantage that WED data are already provided and therefore available without additional post-processing of the image data. Funding Support: NIH Grant R01-EB017095; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski; Disclosures - Cynthia McCollough: Research Grant, Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-11: Adaptive-Beamlet Based Finite Size Pencil Beam (AB-FSPB) Dose Calculation Algorithm for Independent Verification of IMRT and VMAT

Purpose: In current IMRT and VMAT settings, the use of sophisticated dose calculation procedure is inevitable in order to account complex treatment field created by MLCs. As a consequence, independent volumetric dose verification procedure is time consuming which affect the efficiency of clinical workflow. In this study, the authors present an efficient Pencil Beam based dose calculation algorithm that minimizes the computational procedure while preserving the accuracy. Methods: The computational time of Finite Size Pencil Beam (FSPB) algorithm is proportional to the number of infinitesimal identical beamlets that constitute the arbitrary field shape. In AB-FSPB, the dose distribution from each beamlet is mathematically modelled such that the sizes of beamlets to represent arbitrary field shape are no longer needed to be infinitesimal nor identical. In consequence, it is possible to represent arbitrary field shape with combinations of different sized and minimal number of beamlets. Results: On comparing FSPB with AB-FSPB, the complexity of the algorithm has been reduced significantly. For 25 by 25 cm2 squared shaped field, 1 beamlet of 25 by 25 cm2 was sufficient to calculate dose in AB-FSPB, whereas in conventional FSPB, minimum 2500 beamlets of 0.5 by 0.5 cm2 size were needed to calculate dose that was comparable to the Result computed from Treatment Planning System (TPS). The algorithm was also found to be GPU compatible to maximize its computational speed. On calculating 3D dose of IMRT (∼30 control points) and VMAT plan (∼90 control points) with grid size 2.0 mm (200 by 200 by 200), the dose could be computed within 3∼5 and 10∼15 seconds. Conclusion: Authors have developed an efficient Pencil Beam type dose calculation algorithm called AB-FSPB. The fast computation nature along with GPU compatibility has shown performance better than conventional FSPB. This completely enables the implantation of AB-FSPB in the clinical environment for independent volumetric dose verification.

60 APPLIED LIFE SCIENCES↗

Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging

Purpose: The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Methods: Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Results: Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. Conclusions: The authors’ report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-I-37: How Fat Distribution and Table Height Affect Estimates of Patient Size in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and hence CTDIvol and SSDE. Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). This study sought to determine if patient size estimates made from localizer scans is affected by variations in fat distribution, specifically when the widest part of the patient is not at the geometric center of the patient. Methods: Lipid gel bolus material was wrapped around an anthropomorphic phantom to simulate two different body mass distributions. The first represented a patient with fairly rigid fat and had a generally oval shape. The second was bell-shaped, representing corpulent patients more susceptible to gravity’s lustful tug. Each phantom configuration was imaged using an AP localizer and then a PA localizer. This was repeated at various scanner table heights. The width of the phantom was measured from the localizer and diagnostic images using in-house software. Results: 1) The projected phantom width varied up to 39% as table height changed.2) At some table heights, the width of the phantom, designed to represent larger patients, exceeded the localizer field of view, resulting in an underestimation of the phantom width.3) The oval-shaped phantom approached a normalized phantom width of 1 at a table height several centimeters lower (AP localizer) or higher (PA localizer) than did the bell-shaped phantom. Conclusion: Accurate estimation of patient size from localizer scans is dependent on patient positioning with respect to scanner isocenter and is limited in large patients. Further, patient size is more accurately measured on projection images if the widest part of the patient, rather than the geometric center of the patient, is positioned at scanner isocenter.

60 APPLIED LIFE SCIENCES↗

SU-F-T-524: Investigation of the Dosimertric Benefits of Interchangeable Source Size of a Novel Rotating Gamma System

Purpose: Tremendous technological developments were made for conformal therapy techniques with linear accelerators, while less attention was paid to cobalt-60 units. The aim of the current study is to explore the dosimetric benefits of a novel rotating gamma ray system enhanced with interchangeable source sizes and multi-leaf collimator (MLC). Material and Methods: CybeRT is a novel rotating gamma ray machine with a ring gantry that ensures an iso-center accuracy of less than 0.3 mm. The new machine has a 70cm source axial distance allowing for improved penumbra compared to conventional machines. MCBEAM was used to simulate Cobalt-60 beams from the CybeRT head, while the MCPLAN code was used for modeling the MLC and for phantom/patient dose calculation. The CybeRT collimation will incorporate a system allowing for interchanging source sizes. In this work we have created phase space files for 1cm and 2cm source sizes. Evaluation of the system was done by comparing CybeRT beams with the 6MV beams in a water phantom and in patient geometry. Treatment plans were compared based on isodose distributions and dose volume histograms. Results: Profiles for the 1cm source were comparable to that from 6MV in the order of 6mm for 10×10 cm{sup 2} field size at the depth of maximum dose. This could ascribe to Cobalt-60 beams producing lowerenergy secondary electrons. Although, the 2cm source have a larger penumbra however it could be still used for large targets with proportionally increased dose rate. For large lung targets, the difference between cobalt and 6MV plans is clinically insignificant. Our preliminary results showed that interchanging source sizes will allow cobalt beams for volumetric arc therapy of both small lesions and large tumors. Conclusion: The CybeRT system will be a cost effective machine capable of performing advanced radiation therapy treatments of both small tumors and large target volumes.

60 APPLIED LIFE SCIENCES↗

Determination of the size and phase composition of silver nanoparticles in a gel film of bacterial cellulose by small-angle X-ray scattering, electron diffraction, and electron microscopy

The nanoscale structural features in a composite (gel film of Acetobacter Xylinum cellulose with adsorbed silver nanoparticles, stabilized by N-polyvinylpyrrolidone) have been investigated by small-angle X-ray scattering. The size distributions of inhomogeneities in the porous structure of the cellulose matrix and the size distributions of silver nanoparticles in the composite have been determined. It is shown that the sizes of synthesized nanoparticles correlate with the sizes of inhomogeneities in the gel film. Particles of larger size (with radii up to 100 nm) have also been found. Electron microscopy of thin cross sections of a dried composite layer showed that large particles are located on the cellulose layer surface. Electron diffraction revealed a crystal structure of silver nanoparticles in the composite.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems [SWR-22-50]

Gradient-based controllers have parameters called step sizes that determine how sensitive its control actions are to received inputs. Finding a practical setting for a step size is important. If it is too small, the controller is ineffective by not reacting in a significant manor to its received inputs. On the other hand, if it is too large, the actions implemented by the controller may be excessive and cause the controlled system to become unstable. The main objective of the Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems is to speed up the implementation of gradient-based control schemes by automatically tuning its step sizes instead of having a practitioner spend considerable time doing the task manually. Only simple adjustments need to be made to the code of each controller with a step size to allow the addition of an individual automatic tuner. This can be applied to any RT-OPF based control for DER management.

Comden, Joshua↗

Tradeoffs in the Evolution of Caste and Body Size in the Hyperdiverse Ant Genus Pheidole

The efficient investment of resources is often the route to ecological success, and the adaptability of resource investment may play a critical role in promoting biodiversity. The ants of the “hyperdiverse” genus Pheidole produce two discrete sterile castes, soldiers and minor workers. Within Pheidole, there is tremendous interspecific variation in proportion of soldiers. The causes and correlates of caste ratio variation among species of Pheidole remain enigmatic. Here we test whether a body size threshold model accounts for interspecific variation in caste ratio in Pheidole, such that species with larger body sizes produce relatively fewer soldiers within their colonies. We evaluated the caste ratio of 26 species of Pheidole and found that the body size of workers accounts for interspecific variation in the production of soldiers as we predicted. Twelve species sampled from one forest in Costa Rica yielded the same relationship as found in previously published data from many localities. We conclude that production of soldiers in the most species-rich group of ants is regulated by a body size threshold mechanism, and that the great variation in body size and caste ratio in Pheidole plays a role in niche divergence in this rapidly evolving taxon.

59 BASIC BIOLOGICAL SCIENCES↗

BIG LEAF is a regulator of organ size and adventitious root formation in poplar

Here we report the discovery through activation tagging and subsequent characterization of the BIG LEAF (BL) gene from poplar. In poplar, BL regulates leaf size via positively affecting cell proliferation. Up and downregulation of the gene led to increased and decreased leaf size, respectively, and these phenotypes corresponded to increased and decreased cell numbers. BL function encompasses the early stages of leaf development as native BL expression was specific to the shoot apical meristem and leaf primordia and was absent from the later stages of leaf development and other organs. Consistently, BL downregulation reduced leaf size at the earliest stages of leaf development. Ectopic expression in mature leaves resulted in continued growth most probably via sustained cell proliferation and thus the increased leaf size. In contrast to the positive effect on leaf growth, ectopic BL expression in stems interfered with and significantly reduced stem thickening, suggesting that BL is a highly specific activator of growth. Additionally, stem cuttings from BL overexpressing plants developed roots, whereas the wild type was difficult to root, demonstrating that BL is a positive regulator of adventitious rooting. Large transcriptomic changes in plants that overexpressed BL indicated that BL may have a broad integrative role, encompassing many genes linked to organ growth. Here, we conclude that BL plays a fundamental role in control of leaf size and thus may be a useful tool for modifying plant biomass productivity and adventitious rooting.

59 BASIC BIOLOGICAL SCIENCES↗

Development of an ejecta particle size measurement diagnostic based on Mie scattering

The goal of this work is to determine the feasibility of extracting the size of particles ejected from shocked metal surfaces (ejecta) from the angular distribution of light scattered by a cloud of such particles. The basis of the technique is the Mie theory of scattering, and implicit in this approach are the assumptions that the scattering particles are spherical and that single scattering conditions prevail. The meaning of this latter assumption, as far as experimental conditions are concerned, will become clear later. The solution to Maxwell’s equations for spherical particles illuminated by a plane electromagnetic wave was derived by Gustav Mie more than 100 years ago, but several modern treatises discuss this solution in great detail. The solution is a complicated series expansion of the scattered electric field, as well as the field within the particle, from which the total scattering and absorption cross sections as well as the angular distribution of scattered intensity can be calculated numerically. The detailed nature of the scattering is determined by the complex index of refraction of the particle material as well as the particle size parameter, x, which is the product of the wavenumber of the incident light and the particle radius, i.e. x = 2rπ= λ. Figure 1 shows the angular distribution of scattered light for different particle size parameters and two orthogonal incident light polarizations as calculated using the Mie solution. It is obvious that the scattering pattern is strongly dependent on the particle size parameter, becoming more forward-directed and less polarizationdependent as the particle size parameter increases. This trend forms the basis for the diagnostic design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bubble-Size Evolution during Polyurethane Foam Expansion

We are developing computational models to elucidate the expansion and dynamic filling process of a polyurethane (PMDI) foam used to encapsulate electronic components or to produce lightweight structural parts. The polyurethane of interest is a chemically blown foam, where carbon dioxide is produced via the reaction of water, a blowing agent, and isocyanate. Here, we take a careful look at the evolution of the bubble sizes during blowing. This information will help the development of subgrid models to predict bubble formation, growth, coalescence and collapse, drainage, and, hence, eventually the development of engineering models to predict foam expansion into a mold. Close-up views of bubbles at a transparent wall of a narrow, temperature-controlled channel are recorded during the foaming reaction and analyzed with image processing. Because these bubbles are pressed against the wall, the bubble sizes in the last frames after the expansion has stopped are compared to scanning electron microscope (SEM) images of the interior of some of the cured samples to determine if the presence of the wall significantly changes the bubble sizes. In addition, diffusing wave spectroscopy (DWS) is used to determine the average bubble sizes across the width of a similar channel as the bubbles change with time. DWS also gives information about microstructural changes as bubbles rearrange upon bubble collapse or coalescence. In this paper we conclude qualitatively that the bubble size distribution is heavily dependent on the formulation of foam being tested, temperature, the height in the foam bar, the proximity to a wall, and the degree of over-packing.

36 MATERIALS SCIENCE↗

Analytic Framework for Optimal Sizing of Hydrogen Fueling Stations for Heavy Duty Vehicles at Ports (CRADA 512)

This CRADA presents the strategy that PNNL and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL) in properly sizing a hydrogen station for class 8 drayage trucks at the Port of Seattle (Port), as part of a coordinated plan of mixed uses for hydrogen. The proper sizing for the fueling station is unique from past experiences because it will be part of a coordinated plan for a multi-use scheme for the hydrogen, and not a stand-alone fueling station. The multiple use-streams, and their relative values, will impact all facets of station sizing and design, including fueling rates, storage technology and size, equipment selection, and safety considerations. The future deployment of this fueling station, and its proper sizing, is seen as a critical first step in the larger vision of utilizing hydrogen to address a range of issues for SCL and the Port. These include, but are not limited to, large scale fueling of medium duty (MD) and heavy duty (HD) vehicles to reduce emissions, support of adjacent light duty (LD) vehicles, support of critical port operation during extreme events (e.g. resiliency), mitigation of capital intensive electrical distribution system upgrades to support evolving port operations, a market resource that can be used by SCL to generate revenue, and support of planned future maritime operations that currently require heavy use of shipboard hydrogen. While the broader use of hydrogen by SCL and the Port is not the focus of this CRADA, how its use impacts the design of the initial vehicle fueling station, and the modular approach, are the central work. As such, this project will develop the framework and process for developing a modular station design that considers the broader range of coordinate uses of hydrogen as an energy resource.

08 HYDROGEN↗

238 PuO 2 In Vitro Lung Dissolution Rate and Particle Size Determination for Material Involved in the June 8, 2020 Incident at the Los Alamos National Laboratory PF-4 Facility

As part of the LANL response to the June 8, 2020 238 PuO 2 inhalation exposure incident in PF-4, the Nuclear and Radiochemistry Group (C-NR) was asked to assist in determining the lung dissolution rate and particle size distribution of the airborne material. These material characteristics, along with urine and fecal bioassay data, are used by the Radiation Protection Services (RP-SVS) internal dosimetrists to refine dose estimates for exposed workers. Similar to previous studies, an in vitro lung dissolution rate study was performed to assess how fast 238 Pu is cleared from the lungs. Given that PuO 2 is a relatively insoluble material, it dissolves very slowly and requires in vitro studies of 100 or more days to estimate dissolution rates. This report details the results of a 100 day in vitro dissolution rate study and the particle size characteristics of 238 PuO 2 collected on an air filters during the incident. Results show that the 238 PuO 2 involved in this incident has behavior comparable to PuO 2 from previous in vitro studies, with approximately 1% of material dissolving quickly, and 99% of the material dissolving very slowly, with a half-time of approximately 120 years. This is somewhat slower than what was determined in a previous study of LANL 238 PuO 2 , which had an experimental dissolution half-time of 3 years, but significantly faster than 3000 years measured for 239 PuO 2 . Particle size distribution measurements indicate that particle sizes range from 0.10 µm – 6 µm, with most < 2 µm, which is reasonable based on our understanding of the process history of the 238 PuO 2 . Particle size, specific surface area, calcining temperature, specific activity, and age all are known factors that can impact the dissolution rate of refractory materials, however, there are too few studies to quantify the exact influence of these parameters on a measured dissolution rate. The results of this study add to that knowledge base, and provide new insights into the dissolution rates for this LANL process-specific 238 PuO 2 material.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗