Search NASA⌕ Search

SEARCH · Search NASA

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

AGS-GNN: Attribute-guided Sampling for Graph Neural Networks

We propose AGS-GNN, a novel attribute-guided sampling algorithm for Graph Neural Networks (GNNs) that exploits node features and connectivity structure of a graph while simultaneously adapting for both homophily and heterophily in graphs. (In homophilic graphs vertices of the same class are more likely to be connected, and vertices of different classes tend to be linked in heterophilic graphs.) While GNNs have been successfully applied to homophilic graphs, their application to heterophilic graphs remains challenging. The best-performing GNNs for heterophilic graphs do not fit the sampling paradigm, suffer high computational costs, and are not inductive. We employ samplers based on feature-similarity and feature-diversity to select subsets of neighbors for a node, and adaptively capture information from homophilic and heterophilic neighborhoods using dual channels. Currently, AGS-GNN is the only algorithm that we know of that explicitly controls homophily in the sampled subgraph through similar and diverse neighborhood samples. For diverse neighborhood sampling, we employ submodularity, which was not used in this context prior to our work. The sampling distribution is pre-computed and highly parallel, achieving the desired scalability. Using an extensive dataset consisting of 35 small (<=100K nodes) and large (>100K nodes) homophilic and heterophilic graphs, we demonstrate the superiority of AGS-GNN compare to the current approaches in the literature. AGS-GNN achieves comparable test accuracy to the best-performing heterophilic GNNs, even outperforming methods using the entire graph for node classification. AGS-GNN also converges faster compared to methods that sample neighborhoods randomly, and can be incorporated into existing GNN models that employ node or graph sampling.

artificial intelligence↗

Leaf structural and chemical traits, and BNL field campaign sample details, San Lorenzo, Panama, 2020

This data package includes leaf traits, canopy traits and sample details for leaves from 71 species sampled from the San Lorenzo forest canopy crane site, Panama (PA-SLZ) during the BNL field campaign in January to March 2020. Each leaf sample is described with species, phenological stage and location within vertical canopy profiles. Leaf area index (LAI) and height is presented for each canopy profile location. Leaf mass per area (LMA), leaf water content (LWC) and leaf carbon and nitrogen content are included for a subset of the samples. This data package includes sample details, processed data for leaf traits and LAI (*.csv), LAI raw data (compressed as *.zip) and digital camera images (*.jpg, compressed as *.zip) of the leaf samples. Metadata files include data descriptions (_dd.csv) for tabular data, a list of all species sampled during the campaign (*.csv) and a detailed description of the field campaign protocol and methods (*.pdf). See related datasets for leaf gas exchange, leaf water potential and leaf spectral measurements made on the samples described here.

54 ENVIRONMENTAL SCIENCES↗

A Surrogate-based Adaptive Sampling Approach for History Matching and Uncertainty Quantification

A critical procedure in reservoir simulations is history matching (or data assimilation in a broader sense), which calibrates model parameters such that the simulation results are consistent with field measurements, and hence improves the credibility of the predictions given by the simulations. Often there exist non-unique combinations of parameter values that all yield the simulation results matching the measurements. For such ill-posed history matching problems, Bayesian theorem provides a theoretical foundation to represent different solutions and to quantify the uncertainty with the posterior PDF. Lacking an analytical solution in most situations, the posterior PDF may be characterized with a sample of realizations, each representing a possible scenario. A novel sampling algorithm is presented here for the Bayesian solutions to history matching problems. We aim to deal with two commonly encountered issues: 1) as a result of the nonlinear input-output relationship in a reservoir model, the posterior distribution could be in a complex form, such as multimodal, which violates the Gaussian assumption required by most of the commonly used data assimilation approaches; 2) a typical sampling method requires intensive model evaluations and hence may cause unaffordable computational cost. In the developed algorithm, we use a Gaussian mixture model as the proposal distribution in the sampling process, which is simple but also flexible to approximate non-Gaussian distributions and is particularly efficient when the posterior is multimodal. Also, a Gaussian process is utilized as a surrogate model to speed up the sampling process. Furthermore, an iterative scheme of adaptive surrogate refinement and re-sampling ensures sampling accuracy while keeping the computational cost at a minimum level. The developed approach is demonstrated with an illustrative example and shows its capability in handling the above-mentioned issues. Multimodal posterior of the history matching problem is captured and are used to give a reliable production prediction with uncertainty quantification. The new algorithm reveals a great improvement in terms of computational efficiency comparing previously studied approaches for the sample problem.

Li, Weixuan↗

Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

Davis, Morgan P.↗

SLUDGE BATCH 7 ACCEPTANCE EVALUATION: RADIONUCLIDE CONCENTRATIONS IN TANK 51 SB7 QUALIFICATION SAMPLE PREPARED AT SRNL

Presented in this report are radionuclide concentrations required as part of the program of qualifying Sludge Batch Seven (SB7) for processing in the Defense Waste Processing Facility (DWPF). The SB7 material is currently in Tank 51 being washed and prepared for transfer to Tank 40. The acceptance evaluation needs to be completed prior to the transfer of the material in Tank 51 to Tank 40. The sludge slurry in Tank 40 has already been qualified for DWPF and is currently being processed as SB6. The radionuclide concentrations were measured or estimated in the Tank 51 SB7 Qualification Sample prepared at Savannah River National Laboratory (SRNL). This sample was prepared from the three liter qualification sample of Tank 51 sludge slurry (HTF-51-10-125) received on September 18, 2010. The sample was delivered to SRNL where it was initially characterized in the Shielded Cells. With consultation from the Liquid Waste Organization, the qualification sample was then modified by several washes and decants, which included addition of Pu from H Canyon and sodium nitrite per the Tank Farm corrosion control program. This final slurry now has a composition expected to be similar to that of the slurry in Tank 51 after final preparations have been made for transfer of that slurry to Tank 40. Determining the radionuclide concentrations in this Tank 51 SB7 Qualification Sample is part of the work requested in Technical Task Request (TTR) No. HLW-DWPF-TTR-2010-0031. The radionuclides included in this report are needed for the DWPF Radiological Program Evaluation, the DWPF Waste Acceptance Criteria (TSR/WAC) Evaluation, and the DWPF Solid Waste Characterization Program (TTR Task I.2). Radionuclides required to meet the Waste Acceptance Product Specifications (TTR Task III.2.) will be measured at a later date after the slurry from Tank 51 has been transferred to Tank 40. Then a sample of the as-processed SB7 will be taken and transferred to SRNL for measurement of these radionuclides. The results presented in this report are those necessary for DWPF to assess if the Tank 51 SB7 sample prepared at SRNL meets the requirements for the DWPF Radiological Program Evaluation, the DWPF Waste Acceptance Criteria evaluation, and the DWPF Solid Waste Characterization Program. Concentrations are given for thirty-four radionuclides along with total alpha and beta activity. Values for total gamma and total gamma plus beta activities are also calculated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filtration and Leach Testing for PUREX Cladding Sludge and REDOX Cladding Sludge Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan (Barnes and Voke 2006). The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Hanford Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP RPP WTP 467 (Fiskum et al. 2007), eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan. • Characterizing the homogenized sample groups. • Performing parametric leaching testing on each group for compounds of interest. • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on a filtration/leaching test performed using two of the eight waste composite samples. The sample groups examined in this report were the plutonium-uranium extraction (PUREX) cladding waste sludge (Group 3, or CWP) and reduction-oxidation (REDOX) cladding waste sludge (Group 4, or CWR). Both the Group 3 and 4 waste composites were anticipated to be high in gibbsite, thus requiring caustic leaching. WTP RPT 167 (Snow et al. 2008) describes the homogenization, characterization, and parametric leaching activities before benchtop filtration/leaching testing of these two waste groups. Characterization and initial parametric data in that report were used to plan a single filtration/leaching test using a blend of both wastes. The test focused on filtration testing of the waste and caustic leaching for aluminum, in the form of gibbsite, and its impact on filtration. The initial sample was diluted with a liquid simulant to simulate the receiving concentration of retrieved tank waste into the UFP2 vessel (< 10 wt% undissolved solids). Filtration testing was performed on the dilute waste sample and dewatered to a higher solids concentration. Filtration testing was then performed on the concentrated slurry. Afterwards, the slurry was caustic leached to remove aluminum present in the undissolved solid present in the waste. The leach was planned to simulate leaching conditions in the UFP2 vessel. During the leach, slurry supernate samples were collected to measure the dissolution rate of aluminum in the waste. After the slurry cooled down from the elevated leach temperature, the leach liquor was dewatered from the solids. The remaining slurry was rinsed and dewatered with caustic solutions to remove a majority of the dissolved aluminum from the leached slurry. The concentration of sodium hydroxide in the rinse solutions was high enough to maintain the solubility of the aluminum in the dewatered rinse solutions after dilution of the slurry supernate. Filtration tests were performed on the final slurry to compare to filtration performance before and after caustic leaching.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SOLID PHASE CHARACTERIZATION OF HEEL SAMPLES FROM TANK 241-C-110

During sluicing operations of tank 241-C-110, a significant amount of solids were unable to be retrieved. These solids (often referred to as the tank 'heel') were sampled in 2010 and chemically and mineralogically analyzed in the 222-S Laboratory. Additionally, dissolution tests were performed to identify the amount of undissolvable material after using multiple water contacts. This report covers the solid phase characterization of six samples from these tests using scanning electron microscopy, polarized light microscopy, and X-ray diffraction. The chemical analyses, particle size distribution analysis, and dissolution test results are reported separately. Two of the samples were from composites created from as-received material - Composite A and Composite B. The main phase in these samples was sodium-fluoride-phosphate hydrate (natrophosphate) - in the X-ray diffraction spectra, this phase was the only phase identifiable. Polarized light microscopy showed the presence of minor amounts of gibbsite and other phases. These phases were identified by scanning electron microscopy - energy dispersive X-ray spectroscopy as sodium aluminosilicates, sodium diuranate, and sodium strontium phosphate hydrate (nastrophite) crystals. The natrophosphate crystals in the scanning electron microscopy analysis showed a variety of erosive and dissolution features from perfectly shaped octahedral to well-rounded appearance. Two samples were from water-washed Composites A and B, with no change in mineralogy compared to the as-received samples. This is not surprising, since the water wash had only a short period of water contact with the material as opposed to the water dissolution tests. The last two samples were residual solids from the water dissolution tests. These tests included multiple additions of water at 15 C and 45 C. The samples were sieved to separate a coarser fraction of > 710 {mu}m and a finer fraction of < 710 {mu}m. These two fractions were analyzed separately. The coarser fraction contained mostly gibbsite with minor amounts of sodium aluminosilicates (cancrinite) and bismuth aluminum-rich phases. The finer fraction was mostly composed of gibbsite, the sodium alumino silicate phase, cancrinite, and a poorly crystalline to non-crystalline phase containing varying amounts of iron, bismuth, aluminum, and phosphorus.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Results of MOX Colemanite Concrete Samples Poured August 29, 2012

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Samples poured 8/29/12 were received on 9/20/2012 and analyzed. The average total density of each of the samples measured by the ASTM method C 642 was within the lower bound of 1.88 g/cm 3 . The average partial hydrogen density of samples 8.6.1, 8.7.1, and 8.5.3 as measured using method ASTM E 1311 met the lower bound of 6.04E-02 g/cm 3 . The average measured partial boron density of each sample met the lower bound of 1.65E-01 g/cm 3 measured by the ASTM C 1301 method. The average partial hydrogen density of samples 8.5.1, 8.6.3, and 8.7.3 did not meet the lower bound. The samples, as received, were not wrapped in a moist towel as previous samples and appeared to be somewhat drier. This may explain the lower hydrogen partial density with respect to previous samples.

36 MATERIALS SCIENCE↗

Analytical Results of MOX Colemanite Concrete Samples Poured August 29, 2012

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Samples poured 8/29/12 were received on 9/20/2012 and analyzed. The average total density of each of the samples measured by the ASTM method C 642 was within the lower bound of 1.88 g/cm 3 . The average partial hydrogen density of samples 8.6.1, 8.7.1, and 8.5.3 as measured using method ASTM E 1311 met the lower bound of 6.04E-02 g/cm 3 . The average measured partial boron density of each sample met the lower bound of 1.65E-01 g/cm 3 measured by the ASTM C 1301 method. The average partial hydrogen density of samples 8.5.1, 8.6.3, and 8.7.3 did not meet the lower bound. The samples, as received, were not wrapped in a moist towel as previous samples and appeared to be somewhat drier. This may explain the lower hydrogen partial density with respect to previous samples.

36 MATERIALS SCIENCE↗

Comparison of Results for Quarter 1 Surface Water Split Samples Collected at the Nuclear Fuel Services Site, Erwin, Tennessee

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on August 22, 2012. Representatives from the U.S. Nuclear Regulatory Commission and Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses. The comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates that, at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty. The NFS split sample report does not specify the confidence level of reported uncertainties. Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. A comparison of split sample results, using the DER equation, indicates one set with a DER greater than 3. A DER of 3.1 is calculated for gross alpha results from ORAU sample 5198W0003 and NFS sample MCU-310212003. The ORAU result is 0.98 ± 0.30 pCi/L (value ± 2 sigma) compared to the NFS result of -0.08 ± 0.60 pCi/L. Relatively high DER values are not unexpected for low (e.g., background) analyte concentrations analyzed by separate laboratories, as is the case here. It is noted, however, NFS uncertainties are at least twice the ORAU uncertainties, which contributes to the elevated DER value. Differences in ORAU and NFS minimum detectable activities are even more pronounced. comparison of ORAU and NFS split samples produces reasonably consistent results for low (e.g., background) concentrations.

54 ENVIRONMENTAL SCIENCES↗

Rheology and TIC/TOC Results of ORNL Tank Samples

The Savannah River National Laboratory (SRNL)) was requested by Oak Ridge National Laboratory (ORNL) to perform total inorganic carbon (TIC), total organic carbon (TOC), and rheological measurements for several Oak Ridge tank samples. As received slurry samples were diluted and submitted to SRNL-Analytical for TIC and TOC analyses. Settled solids yield stress (also known as settled shear strength) of the as received settled sludge samples were determined using the vane method and these measurements were obtained 24 hours after the samples were allowed to settled undisturbed. Rheological or flow properties (Bingham Plastic viscosity and Bingham Plastic yield stress) were determined from flow curves of the homogenized or well mixed samples. Other targeted total suspended solids (TSS) concentrations samples were also analyzed for flow properties and these samples were obtained by diluting the as-received sample with de-ionized (DI) water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gasbuggy, New Mexico, Natural Gas and Produced Water Sampling and Analysis Results for 2011

The U.S. Department of Energy (DOE) Office of Legacy Management conducted natural gas sampling for the Gasbuggy, New Mexico, site on June 7 and 8, 2011. Natural gas sampling consists of collecting both gas samples and samples of produced water from gas production wells. Water samples from gas production wells were analyzed for gamma-emitting radionuclides, gross alpha, gross beta, and tritium. Natural gas samples were analyzed for tritium and carbon-14. ALS Laboratory Group in Fort Collins, Colorado, analyzed water samples. Isotech Laboratories in Champaign, Illinois, analyzed natural gas samples.

54 ENVIRONMENTAL SCIENCES↗

March 2011 Groundwater Sampling at the Project Shoal Site (Data Validation Package)

The U.S. Department of Energy Office of Legacy Management conducted annual sampling at the Project Shoal Area (Shoal) in March 2011. Wells HC-1, HC-2, HC-4, HC-5, HC-6, HC-7, MV-1, MV-2 and MV-3 were sampled as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351, continually updated). Two extra tritium samples were collected from well HC-4, one sample (HC-4-400) was collected at about 1/3 of the purge volume (135 gallons), the second sample (HC-4-400) was collected at 2/3 of purge volume (270 gallons). These additional samples were collected prior to completing the well purging process to evaluate the effects well purging has on the analytical results. Samples were not collected from locations HC-3 and HC-8 at the direction of the S.M. Stoller Corporation site lead.

54 ENVIRONMENTAL SCIENCES↗

Draft SOP for Sample Matching using ICP-MS

The purpose of this standard operating procedure (SOP) is to provide an assay for testing the hypothesis that two samples are from the same sub-population, which can mean they came from the same batch, set of replicate batches, or the same process. The outcome is a likelihood ratio, which should be used in combination with prior odds to determine the posterior odds of the two samples coming from the same sub-population. Note that the term “match” is not used because it is imprecise in the context of determining the relationship between two samples. Under this SOP, inductively coupled plasma mass spectrometer (ICP-MS) is used to generate elemental composition data, which is used to test the hypothesis that two samples come from the same sub-population. ICP-MS is a highly sensitive bulk analysis method. The quantity of sample required is ultimately determined by the instrumentation used and the elements selected for generating ROC curves. This SOP specifies that greater than 5 mg of sample be used to enable accurate weights to be obtained for the sample in tared 3 mL Teflon vials. However, we have conducted preliminary assays with our instrumentation that suggest that sample quantity can be reduced to 50 micrograms if elemental abundances are normalized to total metal content (see Step 10). We use ICP-MS because it is the most sensitive method for determining the concentration of the largest number of elements. Other elemental analysis methods could be used to generate data for this test (e.g., ICP-OES), but specific tests would be necessary to work out the SOP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Tank 35H Samples in Support of Salt Batch Planning

Savannah River Remediation obtained three samples from different heights within Tank 35H. The samples were analyzed by Savannah River National Laboratory to support Salt Batch planning. The results from the analysis indicate the compositions of the three samples show increasing concentrations for most analytes going from HTF-35-15-17 through HTF-35-15-19 corresponding to successively deeper sampling locations. The data indicate some stratification within the tank. The plutonium and Sr-90 concentrations measured in the filtered samples were slightly lower than in the decanted (unfiltered) samples. The difference in the results for the filtered and unfiltered samples likely lies within the expected uncertainty for the measurement, but may indicate that filtration removed a small amount of suspended material from the samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SNS Sample Activation Calculator Flux Recommendations and Validation

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples. The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.

43 PARTICLE ACCELERATORS↗

Results of Hg speciation testing on tank 39 and 1Q16 tank 50 samples

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team.i,ii The seventeenth shipment of samples was designated to include two Tank 39 samples and the 1Q16 Tank 50 Quarterly WAC sample. The surface Tank 39 sample was pulled at 262.1” from the tank bottom, and the depth Tank 39 sample was pulled at 95” from the tank bottom. The 1Q16 Tank 50 WAC sample was drawn from the 1-L variable depth sample received by SRNL.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

K West Basin Sand Filter Backwash Sample Analysis

A sand filter is used to help maintain water clarity at the K West Basin where highly radioactive sludge is stored. Eventually that sand filter will require disposal. The radionuclide content of the solids trapped in the sand filter will affect the selection of the sand filter disposal pathway. The Pacific Northwest National Laboratory (PNNL) was contracted by the K Basin Operations & Plateau Remediation Project (operations contractor CH2M Hill) to analyze the radionuclide content of the solids collected from the backwash of the K West Basin sand filter. The radionuclide composition in the sand filter backwash solids will be used by CH2M Hill to determine if the sand filter media and retained sludge solids will be designated as transuranic waste for disposal purposes or can be processed through less expensive means. On October 19, 2015, K Basin Operations & Plateau Remediation Project staff backwashed the sand filter into the North Load-Out Pit (NLOP) and immediately collected sample slurry from a sampling tube positioned 24 in. above the NLOP floor. The 764 g sand filter backwash slurry sample, KW-105 SFBW-001, was submitted to PNNL for analysis on October 20, 2015. Solids from the slurry sample were consolidated into two samples (i.e., a primary and a duplicate sample) by centrifuging and measured for mass (0.82 g combined – wet centrifuged solids basis) and volume (0.80 mL combined). The solids were a dark brown/orange color, consistent with iron oxide/hydroxide. The solids were dried; the combined dry solids mass was 0.1113 g, corresponding to 0.0146 weight percent (wt%) solids in the original submitted sample slurry. The solids were acid-digested using nitric and hydrochloric acids. Insoluble solids developed upon dilution with 0.5 M HNO 3 , corresponding to an average 6.5 wt% of the initial dry solids content. The acid digestate and insoluble solids were analyzed separately by gamma spectrometry. Nominally, 7.7% of the 60 Co was present in the insoluble solids; less than 1% of other gamma-emitters (i.e., 137 Cs, 154/155 Eu, and 241 Am) were present in the insoluble solids. Aliquots of the acid digestate were analyzed directly using gamma energy analysis (GEA) and after separations for 238 Pu, 239+240 Pu, 237 Np, and 241 Am radioisotopes using alpha energy analysis (AEA). The 90 Sr was measured by liquid scintillation counting (LSC) on the Sr-separated fraction. The plutonium isotopic distribution of the acid digestate was analyzed following Pu separations by thermal ionization mass spectrometry (TIMS). A table summarizes the results for the primary and duplicate samples. The 239+240 Pu concentration (µCi/g dry) relative to 90 Sr and to 137 Cs concentrations (µCi/g dry) was examined. The K West Basin sludge has a 239+240 Pu/ 90 Sr ranging from 0.1 to 1.2 and the 239+240 Pu/ 137 Cs ratio ranging from 0.10 to 0.47. In contrast, the sand filter backwash solids 239+240 Pu/ 90 Sr ratio was 10.6 and the 239+240 Pu/ 137 Cs ratio was 2.0. The ratio differences indicate a relative enhancement of the Pu concentration in the sand filter solids relative to the 137 Cs and 90 Sr sludge concentrations currently in the K West Basin. A dose-to-curie radioisotope evaluation of the sand filter waste form may need to consider this dissimilarity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗