Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Cell Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Use of a Conventional Low Neck Field (LNF) and Intensity-Modulated Radiotherapy (IMRT): No Clinical Detriment of IMRT to an Anterior LNF During the Treatment of Head-and Neck-Cancer

Purpose: To determine differences in clinical outcomes using intensity-modulated radiotherapy (IMRT) or a standard low neck field (LNF) to treat low neck. Methods and Materials: This is a retrospective, single-institution study. Ninety-one patients with squamous cell carcinoma of the head and neck were treated with curative intent. According to physician preference, some patients were treated with LNF (Planning Target Volume 3) field using a single anterior photon field matched to the IMRT field. Field junctions were not feathered. The endpoints were time to failure and use of a percutaneous endoscopic gastrostomy (PEG) tube (as a surrogate of laryngeal edema causing aspiration), and analysis was done with {chi}{sup 2} and log-rank tests. Results: Median follow-up was 21 months (range, 2-89 months). Median age was 60 years. Thirty-seven patients (41%) were treated with LNF, 84% were Stage III or IV. A PEG tube was required in 30%, as opposed to 33% without the use of LNF. Node 2 or 3 neck disease was treated more commonly without LNF (38% vs. 24%, p = 0.009). Failures occurred in 12 patients (13%). Only 1 patient treated with LNF failed regionally, 4.5 cm above the match line. The 3-year disease-free survival rate was 87% and 79% with LNF and without LNF, respectively (p = 0.2), and the 3-year LR failure rate was 4% and 21%, respectively (p = 0.04). Conclusions: Using LNF to treat the low neck did not increase the risk of regional failure 'in early T and early N diseases' or decrease PEG tube requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear dynamics of influenza A virus ribonucleoproteins revealed by live-cell imaging studies

The negative sense RNA genome of influenza A virus is transcribed and replicated in the nuclei of infected cells by the viral RNA polymerase. Only four viral polypeptides are required but multiple cellular components are potentially involved. We used fluorescence recovery after photobleaching (FRAP) to characterise the dynamics of GFP-tagged viral ribonucleoprotein (RNP) components in living cells. The nucleoprotein (NP) displayed very slow mobility that significantly increased on formation of transcriptionally active RNPs. Conversely, single or dimeric polymerase subunits showed fast nuclear dynamics that decreased upon formation of heterotrimers, suggesting increased interaction of the full polymerase complex with a relatively immobile cellular component(s). Treatment with inhibitors of cellular transcription indicated that in part, this reflected an interaction with cellular RNA polymerase II. Analysis of mutated influenza virus polymerase complexes further suggested that this was through an interaction between PB2 and RNA Pol II separate from PB2 cap-binding activity.

60 APPLIED LIFE SCIENCES↗

Using In Situ High-Energy X-ray Diffraction to Quantify Electrode Behavior of Li-Ion Batteries from Extreme Fast Charging

Extreme fast charging (XFC, =15 min charging time) of Li-ion batteries (LIBs) has been proposed as an immediate target to increase the commercial appeal of electric vehicles. However, XFC of LIBs is associated with the degradation of battery performance and safety concerns. Quantitative and simultaneous characterization of various components during cell degradation represents a major experimental challenge. In this work, we outline a methodology for the use of spatially resolved, high-energy X-ray diffraction as a quantitative, in situ method of mapping the degradation of LIBs. We use this approach to study the battery cell capacity loss, both locally (mm scale) and globally over the entire cell (cm scale). Specifically, our workflow allows us to quantify the total amount of plated Li on the anode, as well as its spatial correlation to the structural properties of the anode and cathode. The method complements existing optical methods to resolve the spatial heterogeneity of local degradation mechanisms such as Li plating and provides simultaneous insights into concomitant anode state-of-charge variability. We apply it to commercially relevant single-layer pouch cells with the graphite anode and the LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathode. Our results show that Li plating occurs heterogeneously on the graphite anode and that it is spatially correlated to the extent of anode lithiation. In this work, we anticipate that the described workflow will allow for understanding multiscale degradation in energy-storage devices beyond LIBs, where quantitative analysis at a local and global length scale can be performed without the necessity to tear down the device, due to the applicability of high-energy X-rays to probe in situ degradation.

25 ENERGY STORAGE↗

Computational ranking identifies Plexin-B2 in circulating tumor cell clustering with monocytes in breast cancer metastasis

Abstract Multicellular circulating tumor cell (CTC) clusters can be up to 50 times more efficient than single CTCs in mediating viable metastasis. Here, combining computational ranking and functional determination, we identify the transmembrane protein Plexin-B2 (PLXNB2) as one of the top molecular targets associated with unfavorable distant metastasis-free survival, showing enriched expression in CTC clusters versus single CTCs from patients with advanced breast cancer (mostly female). Loss of PLXNB2 (Plxnb2) reduces the formation of homotypic tumor cell clusters and heterotypic tumor-myeloid cell clusters, reducing spontaneous metastases in female mice bearing human (mouse) breast cancer. Interactions of PLXNB2 with its ligands SEMA4C on tumor cells and SEMA4A on myeloid cells (monocytes) promote homotypic and heterotypic CTC cluster formation, respectively, thereby driving lung metastasis. Global proteomic analysis reveals downstream effectors of the PLXNB2 pathway associated with tumor cell clustering. Thus, PLXNB2 is a therapeutic target for preventing new metastasis in breast cancer.

Science & Technology - Other Topics↗

Experimental and computational studies on high-entropy carbide MoNbTaVWC 5 under high pressures

High-entropy carbide, MoNbTaVWC 5 , was synthesized from oxide precursors of the constituent metals, mixed with graphite powder in a microwave-generated hydrogen plasma at 26.66 kPa and 2100 °C. Ambient x-ray diffraction analysis confirms the full conversion of oxide precursors into a single-phase, face-centered cubic structure with a lattice parameter a = 4.3309 Å. Nanoindentation measured a hardness of 24.5 ± 1.3 GPa and an elastic modulus of 386 ± 22 GPa. The synthesized sample, mixed with a copper pressure marker, was studied by the radial x-ray diffraction technique with beryllium gasketing in a diamond anvil cell up to 70 GPa. The experimentally measured pressure–volume curve and shear strength were compared with theoretical predictions using the special quasi-random structure technique and density functional theory. MoNbTaVWC 5 achieved a 12% volume compression at 70 GPa and exhibited a high shear strength of 6.6 GPa. The present study demonstrates that the high-entropy carbide MoNbTaVWC 5 exhibits exceptional incompressibility and high strength under extreme conditions.

36 MATERIALS SCIENCE↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Structure and in vivo psoralen DNA crosslink repair activity of mycobacterial Nei2

Mycobacterium smegmatis Nei2 is a monomeric enzyme with AP β-lyase activity on single-stranded DNA. Expression of Nei2, and its operonic neighbor Lhr (a tetrameric 3'-to-5' helicase), is induced in mycobacteria exposed to DNA damaging agents. Here, we find that nei2 deletion sensitizes M. smegmatis to killing by DNA inter-strand crosslinker trimethylpsoralen but not to crosslinkers mitomycin C and cisplatin. By contrast, deletion of lhr sensitizes to killing by all three crosslinking agents. We report a 1.45 Å crystal structure of recombinant Nei2, which is composed of N and C terminal lobes flanking a central groove suitable for DNA binding. The C lobe includes a tetracysteine zinc complex. Mutational analysis identifies the N-terminal proline residue (Pro2 of the ORF) and Lys51, but not Glu3, as essential for AP lyase activity. We find that Nei2 has 5-hydroxyuracil glycosylase activity on single-stranded DNA that is effaced by alanine mutations of Glu3 and Lys51 but not Pro2. Testing complementation of psoralen sensitivity by expression of wild-type and mutant nei2 alleles in Δnei2 cells established that AP lyase activity is neither sufficient nor essential for crosslink repair. By contrast, complementation of psoralen sensitivity of Δlhr cells by mutant lhr alleles depended on Lhr’s ATPase/helicase activities and its tetrameric quaternary structure. The lhr–nei2 operon comprises a unique bacterial system to rectify inter-strand crosslinks.

59 BASIC BIOLOGICAL SCIENCES↗

Genetic Control or Repair and Adaptive Response to Low-Level DNA Damage

Research was focused on how a single double-strand break - a model of low-dose ionizing radiation-induced DNA damage - could be studied in a simple model system, budding yeast. Breaks were induced in several different ways. We used the site-specific HO endonuclease to create a single DSB in all cells of the population so that its fate could be extensively analyzed genetically and molecularly. We also used two heterologous systems, the plant DS element and the Rag1/Rag2 proteins, to generate different types of DSBs, these containing hairpin ends that needed to be cleaved open before end-joining could take place. All three approaches yielded important new findings. We also extended our analysis of the Mre11 protein that plays key roles in both NHEJ and in homologous recombination. Finally we analyzed the poorly understood recombination events that were independent of the key recombination protein, Rad52. This line of inquiry was strongly motivated by the fact that vertebrate cells do not rely strongly on Rad52 for homologous recombination, so that some clues about alternative mechanisms could be gained by understanding how Rad52-independent recombination occurred. We found that the Mre11 complex was the most important element in Rad52-independent recombination.

59 BASIC BIOLOGICAL SCIENCES↗

Status Report on the Modeling of TRISO Energy Deposition, Time-Dependent Temperature Field and Doppler Feedback

The Doppler feedback mechanism is a major contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic coated particles. It follows that the correct prediction of the magnitude and time-dependence of this feedback effect is essential to the conduct of safety analyses for these reactors. We present a fuel conduction model for obtaining better estimates of the temperature feedback during moderate and fast transients. The fuel model has been incorporated in the CYNOD-THERMIX-KONVEK suite of coupled codes as a single TRISO particle within each calculation cell. The heat generation rate is scaled down from the neutronic solution and a Dirichlet boundary condition is imposed as the bulk graphite temperature from the thermal-hydraulic solution. This simplified approach yields similar results to those obtained with more complex methods, requiring multi-TRISO calculations within one control volume, but with much less computational effort. We provide an analysis of the hypothetical total control ejection event in the PBMR-400 design that clearly depicts the improvement in the predictions of the fuel temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Possible Radiation-Induced Transition from Monazite-(Ce) to Xenotime-(Y)

This study examines two pegmatitic monazite samples (2a and 4b, these numbers are related to a previous study) to determine their crystal chemistry and effects of internal radiation damage using synchrotron high-resolution powder X-ray diffraction and electron-probe micro-analysis. Both the huttonite and cheralite substitutions are discussed. Rietveld structure refinement of sample 2a shows three different phases [2a = monazite-(Ce), 2b = monazite-(Ce), and 2c = xenotime-(Y)] with distinct structural parameters. The changes among the unit-cell parameters between the two monazite-(Ce) phases is more pronounced in the a followed by the b and c unit-cell parameters. Sample 4a is a single-phase monazite-(Sm) that contains 0.164 apfu Th. Phase 2c with space group I41/amd arises from redistribution of La, Ce, Pr, Nd, Sm, Gd, Dy, Si, and Y atoms from those in monazite (space group P21/n). A possible cause for the phase transition from monazite-(Ce) to xenotime-(Y) is α-radiation events over a long geological time. However, other chemical processes cannot be ruled out as a cause for the transition.

structural variations↗

Microwave Resonator Measurements of Atmospheric Absorption Coefficients: A Preliminary Design Study

A preliminary design study examined the feasibility of using microwave resonator measurements to improve the accuracy of atmospheric absorption coefficients and refractivity between 18 and 35 GHz. Increased accuracies would improve the capability of water vapor radiometers to correct for radio signal delays caused by Earth's atmosphere. Calibration of delays incurred by radio signals traversing the atmosphere has applications to both deep space tracking and planetary radio science experiments. Currently, the Cassini gravity wave search requires 0.8-1.0% absorption coefficient accuracy. This study examined current atmospheric absorption models and estimated that current model accuracy ranges from 5% to 7%. The refractivity of water vapor is known to 1% accuracy, while the refractivity of many dry gases (oxygen, nitrogen, etc.) are known to better than 0.1%. Improvements to the current generation of models will require that both the functional form and absolute absorption of the water vapor spectrum be calibrated and validated. Several laboratory techniques for measuring atmospheric absorption and refractivity were investigated, including absorption cells, single and multimode rectangular cavity resonators, and Fabry-Perot resonators. Semi-confocal Fabry-Perot resonators were shown to provide the most cost-effective and accurate method of measuring atmospheric gas refractivity. The need for accurate environmental measurement and control was also addressed. A preliminary design for the environmental control and measurement system was developed to aid in identifying significant design issues. The analysis indicated that overall measurement accuracy will be limited by measurement errors and imprecise control of the gas sample's thermodynamic state, thermal expansion and vibration- induced deformation of the resonator structure, and electronic measurement error. The central problem is to identify systematic errors because random errors can be reduced by averaging. Calibrating the resonator measurements by checking the refractivity of dry gases which are known to better than 0.1% provides a method of controlling the systematic errors to 0.1%. The primary source of error in absorptivity and refractivity measurements is thus the ability to measure the concentration of water vapor in the resonator path. Over the whole thermodynamic range of interest the accuracy of water vapor measurement is 1.5%. However, over the range responsible for most of the radio delay (i.e. conditions in the bottom two kilometers of the atmosphere) the accuracy of water vapor measurements ranges from 0.5% to 1.0%. Therefore the precision of the resonator measurements could be held to 0.3% and the overall absolute accuracy of resonator-based absorption and refractivity measurements will range from 0.6% to 1.

Walter, Steven J.↗

Challenges in Scaling Analysis from Coupons to Elements in 3D Woven Composites for a Launch Vehicle End-Ring Structure

The limitations of structural design with 3D woven composites based on homogenized material models characterized using coupon test data, representative unit cell analysis, or a combination of the two are discussed in the context of a space launch system (SLS)-scale end ring. Selected building block test configurations at the coupon, element, and subcomponent scales are described in detail. Highly instrumented tests and X-ray computed tomography inspections are used to characterize the structural behavior and associated damage progression with increasing load. It is shown that a single homogenized material constitutive relationship, applied at coupon and element scale, is not sufficient to model the structural response observed in both tests. In fact, substantially different stress-strain laws are required to predict the response of the coupon and element scale specimens, despite similar loading conditions. A model with discrete representation of the binder tows and cohesive interfaces to model matrix cracking shows much better agreement with the test data at the two length scales. Thus, evidence is provided showing that predictive structural analysis of 3D woven composites requires discrete representation of the tows, matrix cracking morphology, and their interactions in the structural configuration. With accurate knowledge of the element scale behavior, engineering approximations readily enable analysis scale-up to the subcomponent level.

Andrew C Bergan↗

Kinetic Plasma Simulation Capabilities in the MOOSE Framework: Verification of Particle-Particle Collisions

High-fidelity simulations of complex plasma systems allow researchers to gain key insights into and understanding of these systems. To facilitate massively parallel high-fidelity plasma simulations, finite-element-based particle-in-cell capabilities are being developed within the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) based framework called Software for Advanced Large-scale Analysis of MAgnetic confinement for Numerical Design, Engineering & Research (SALAMANDER). While SALAMANDER’s primary objective is modeling edge plasmas and plasma-facing components in fusion devices, the particle-in-cell capabilities being developed are general and will support modeling low-temperature plasmas as well. Previously, collisionless magnetostatic simulation capabilities have been verified with the two-stream and Dorey-Guest-Harris instabilities, and single particle motion. Collisions were implemented using the direct simulation Monte Carlo method, and verification of this capability will be presented here several verification problems: relaxation of a randomly initialized gas to a Maxwellian distribution, Fourier heat flow, and comparison of reaction rates to both analytic calculations and those calculated using a multi-term Boltzmann solver.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Analysis of mobility data to build contact networks for COVID-19

As social distancing policies and recommendations went into effect in response to COVID-19, people made rapid changes to the places they visit. These changes are clearly seen in mobility data, which records foot traffic using location trackers in cell phones. While mobility data is often used to extract the number of customers that visit a particular business or business type, it is the frequency and duration of concurrent occupancy at those sites that governs transmission. Understanding the way people interact at different locations can help target policies and inform contact tracing and prevention strategies. This paper outlines methods to extract interactions from mobility data and build networks that can be used in epidemiological models. Several measures of interaction are extracted: interactions between people, the cumulative interactions for a single person, and cumulative interactions that occur at particular businesses. Network metrics are computed to identify structural trends which show clear changes based on the timing of stay-at-home orders. Measures of interaction and structural trends in the resulting networks can be used to better understand potential spreading events, the percent of interactions that can be classified as close contacts, and the impact of policy choices to control transmission.

60 APPLIED LIFE SCIENCES↗

Spectroscopic Characterization of Highly Active Fe–N–C Oxygen Reduction Catalysts and Discovery of Strong Interaction with Nafion Ionomer

Scaling up clean-energy applications necessitates the development of platinum group metal (PGM)-free fuel cell electrocatalysts with high activity, stability, and low cost. Here, X-ray absorption (XAS) at the Fe K-edge and Fe K β X-ray emission (XES) spectroscopies were used to study the electronic structure of Fe centers in highly active Fe–N–C oxygen reduction catalysts with significant commercial potential. X-ray absorption near-edge structure (XANES) analysis has shown that the majority (>95%) of Fe centers are in the Fe 3+ oxidation state, while extended X-ray absorption fine structure (EXAFS) detected a mixture of single site Fe–N 4 centers (>95%) and centers with short (~2.5 Å) Fe–Fe interactions of Fe metal and/or Fe-carbide nanoparticles (<5%) featuring the Fe o oxidation state. Surprisingly, addition of Nafion, the most widely used ionomer, resulted in pronounced changes in the XAS spectra, consistent with a strong catalyst–ionomer interaction where long Fe–Fe interactions at ~3.1 Å were shown to be a feature of Fe 3+ ions bound with the Nafion. We conclude that exposure to Nafion during the device formulation has a different effect from the aggressive acid leaching typically used in the preparation of Fe–N–C catalysts. Furthermore, it was hypothesized that the polymer interacts with single sites’ Fe 3+ centers, as well as with graphene layers protecting the Fe o nanoparticles, and extracts some Fe ions into the Nafion matrix.

25 ENERGY STORAGE↗

Assessment of Tumor Radioresponsiveness and Metastatic Potential by Dynamic Contrast-Enhanced Magnetic Resonance Imaging

Purpose: It has been suggested that gadolinium diethylene-triamine penta-acetic acid (Gd-DTPA)-based dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) may provide clinically useful biomarkers for personalized cancer treatment. In this preclinical study, we investigated the potential of DCE-MRI as a noninvasive method for assessing the radioresponsiveness and metastatic potential of tumors. Methods and Materials: R-18 melanoma xenografts growing in BALB/c nu/nu mice were used as experimental tumor models. Fifty tumors were subjected to DCE-MRI, and parametric images of K{sup trans} (the volume transfer constant of Gd-DTPA) and v{sub e} (the fractional distribution volume of Gd-DTPA) were produced by pharmacokinetic analysis of the DCE-MRI series. The tumors were irradiated after the DCE-MRI, either with a single dose of 10 Gy for detection of radiobiological hypoxia (30 tumors) or with five fractions of 4 Gy in 48 h for assessment of radioresponsiveness (20 tumors). The host mice were then euthanized and examined for lymph node metastases, and the primary tumors were resected for measurement of cell survival in vitro. Results: Tumors with hypoxic cells showed significantly lower K{sup trans} values than tumors without significant hypoxia (p < 0.0001, n = 30), and K{sup trans} decreased with increasing cell surviving fraction for tumors given fractionated radiation treatment (p < 0.0001, n = 20). Tumors in metastasis-positive mice had significantly lower K{sup trans} values than tumors in metastasis-negative mice (p < 0.0001, n = 50). Significant correlations between v{sub e} and tumor hypoxia, radioresponsiveness, or metastatic potential could not be detected. Conclusions: R-18 tumors with low K{sup trans} values are likely to be resistant to radiation treatment and have a high probability of developing lymph node metastases. The general validity of these observations should be investigated further by studying preclinical tumor models with biological properties different from those of the R-18 tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗