Search NASA⌕ Search

SEARCH · Search NASA

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Yet Another Hauser-Feshbach Code

Code framework to perform simulations of nuclear reactions with incident particles including gammas, protons, neutrons, deuterons, tritons, helium-3, and alphas to develop nuclear data libraries and study nuclear reaction phenomona. The code can model nuclear reactions or initial populations specified by the user. The decays principally follow the compound-nucleus hypothesis and the statistical decay of Hauser and Feshbach. The code models nuclear decays with a Monte Carlo process that tracks the decay of each state. Data libraries are produced that can be translated into GNDS (generalized Nuclear Data Structure). YAHFC can also be used as an event generator, with individual decays written to disk for offline analysis. Both serial and MPI versions are provided. YAHFC does NOT perform transport of nuclear reactions through materials, only the primary reaction with a target material.

Ormand, WilliamE.↗

Global Trends of ASME "N-Stamp" Certifications for Nuclear Component Vendors

Historically, nuclear component manufacturing vendors, from small businesses through large conglomerates, have felt compelled to obtain an American Society for Mechanical Engineers (ASME) Nuclear Certification, known colloquially as an "N-stamp", to assure supply chain quality standards that will be acceptable to regulators and safety concerns. Since the N-stamp quality standard is a U.S.-origin code, combined with the apparent decline in the U.S. nuclear industry alongside the growth of the Asian nuclear industry, there is the question of whether the rest of the world, including new entrants to the nuclear industry, also regard N-stamp as a needed certification. This study addresses this question through analysis of the entire N-stamp database of holders, and former holders, of N-stamp certificates of all types and for all regions worldwide from 1989-2020 (the dates available in the database). From this 30 years of data, we find that actually U.S.-based vendors still consistently obtain the largest number of N-stamps worldwide over all time periods, but also find that the countries participating in the N-stamp certification process has broadly expanded beyond just North America, Japan, S. Korea and Western Europe (the primary N-stamp recipients before the mid-2000's). We produced global heats maps and bar charts to illustrate our findings, as well as further investigation into why the data shows changes over time and region. We note that nuclear entities involved with Soviet-type reactors do not participate in the N-stamp process, but instead pursue the Russian version PNAE, which is substantially similar to the ASME code. We conclude that at least from the N-stamp database, the United States nuclear component manufacturing industry is alive and well, although there have been some consolidations, and that the ASME N-stamp appears to still be a valued certificate worldwide, including in China which now ranks second only to the United States in obtaining N-stamp certificates in recent years. We further note that the vendors of new reactor types, in particular High Temperature Gas-Cooled Reactors (HTGRs) and Small Modular Reactors (SMRs), are actively engaged with ASME (and other U.S.-based nuclear standards bodies such as the American Nuclear Society and Nuclear Energy Institute) to coordinate updates to the ASME N-Stamp criteria to ensure applicability of the code for these new designs. Implications of these findings include the following: The global use of the U.S.-origin N-stamp certification supports the view that, despite the decline of the U.S. nuclear industry, the United States remains an esteemed global leader in the area of nuclear safety. As the U.S. Government works to revitalize the U.S. nuclear industry, especially in the area of exports, it may be beneficial to leverage the global standing of the N-stamp certification. The findings indicate that the N-stamp database would be a useful tool for the U.S. Government to use to track the growth of the civil nuclear industry in foreign countries, under certain circumstances. The Excel-format N-stamp database produced as part of this study may be a useful tool for this purpose. N-stamp data may be a useful tool for foreign governments to use to identify nuclear manufacturers within their own country, especially to identify "targets" for outreach on nuclear export control compliance. The U.S. Government could carry this message to foreign partners during bilateral engagements or as part of Nuclear Suppliers Group (NSG) discussions on industry outreach.

42 ENGINEERING↗

Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D{sub 1} increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D{sub 5} dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CHICO2, a two-dimensional pixelated parallel-plate avalanche counter

CHICO 2 (Compact Heavy Ion COunter), is a large solid-angle, charged-particle detector array developed to provide both θ and Φ angle resolutions matching those of GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array). CHICO 2 was successfully tested at the Argonne National Laboratory where it was fielded as an auxiliary detector with GRETINA for γ-ray spectroscopic studies of nuclei using a 252 Cf spontaneous fission source, stable beams, and radioactive beams from CARIBU. In field tests of the 72,76Ge beams on a 0.5 mg/cm 2 208Pb target at the sub-barrier energy, CHICO 2 provided charged-particle angle resolutions (FWHM) of 1.55° in θ and 2.47° in Φ. This achieves the design goal for both coordinates assuming a beam-spot size (>3 mm) and the target thickness (>0.5 mg/cm 2 ). The combined angular resolution of GRETINA/CHICO 2 resulted in a Doppler-shift corrected energy resolution of 0.60% for 1 MeV coincident de-excitation γ-rays. This is nearly a factor of two improvements in resolution and sensitivity compared to Gammasphere/CHICO. Kinematically-coincident detection of scattered ions by CHICO 2 still maintains the mass resolution (ΔM/M) of ~5% that enhanced isolation of scattered weak beams of interest from scattered contaminant beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The HPS electromagnetic calorimeter

The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon". Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. Finally, the detector is a homogeneous calorimeter, made of 442 lead-tungsten (PbWO$_4$) scintillating crystals, each read-out by an avalanche photodiode coupled to a custom trans-impedance amplifier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulation study of ultra-fast beam bunches split for three orthogonal planes high-energy electron dynamic radiography

Here a compact three orthogonal planes high-energy electron radiography system was proposed. One of the critical technologies, the ultra-fast beam bunches split from the bunch train are studied. The separated bunches could be transported to the three orthogonal planes of the target for dynamic radiography diagnostics. The key elements of the ultra-fast bunches split system are transverse deflecting cavity (TDC) and the twin septum magnet (TSM). The principle of TDC and TSM are briefly introduced. An example of the beam bunches split system for test experiment (40 MeV electron beam) with TDC and TSM is designed and studied by particle-tracking simulation and it confirms this method is valid and feasible. Especially with TSM, a compact three orthogonal planes radiography system can be realized. The evolution of the beam parameters along the beam line from simulation are investigated. The detailed design of the beam split system and beam dynamics simulation study are presented in this paper.

Zhao, Q. T.↗

The beam and detector of the NA62 experiment at CERN

NA62 is a fixed-target experiment at the CERN SPS dedicated to measurements of rare kaon decays. Such measurements, like the branching fraction of the K + → π + ν ν¯ decay, have the potential to bring significant insights into new physics processes when comparison is made with precise theoretical predictions. For this purpose, innovative techniques have been developed, in particular, in the domain of low-mass tracking devices. Detector construction spanned several years from 2009 to 2014. The collaboration started detector commissioning in 2014 and will collect data until the end of 2018. Furthermore, the beam line and detector components are described together with their early performance obtained from 2014 and 2015 data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying Muon Neutrino Charged-Current Interactions in the MicroBooNE Detector

The MicroBooNE experiment is a short-baseline neutrino experiment at the Fermi National Accelerator Laboratory (FNAL) in the US, receiving a highly pure muon neutrino beam from the Booster Neutrino Beam (BNB) and taking data since October 2015. The main physics goal of MicroBooNE is to clarify the nature of the low-energy excess of electron-like events observed by the MiniBooNE Cherenkov detector, which due to its detector technology is unable to resolve whether the observed excess shower-like events are due to electrons or photons. Instead, MicrooBooNE employs cutting-edge liquid argon time projection chamber (LArTPC) technology, which offers excellent spatial and calorimetric resolution, which makes it possible to reconstruct complex neutrino interactions and to efficiently distinguish different final state particle types. This thesis presents a fully-automated event selection of interactions of the types ν μ +Ar → μ - + X and ν μ + Ar → μ - + p + X developed using the Pandora multi-algorithm approach to pattern recognition for LArTPC experiments. The analysis in this work is performed on a subset of the MicroBooNE Run 1 dataset corresponding to 4.52 × 10 19 protons on target acquired by the MicroBooNE detector between February and October 2016. The analysis quantifies the main signal and background interaction channels that produce a reconstructed neutrino interaction with one and two particles in the final state, and quantifies the extent to which different aspects of the Pandora reconstruction affect the selection performance. MicroBooNE is a surface detector, and therefore cosmic-ray tracks are the main observed background. A direction fitting procedure has been implemented in this analysis to formulate directional probabilities, using the Bethe equation and the high-resolution calorimetric information of MicroBooNE, to reduce this cosmic-ray background. This functionality is used to enhance the efficiency of the Pandora cosmic ray tagging logic, and the impact of this procedure on the reconstruction and event selection performance is analysed. The result of this study is two fully-automated selections of ν μ +Ar → μ - + X (57.91% pure) and ν μ + Ar → μ - + p + X (78.30% pure) with efficiencies of 64.35% and 62.65%, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Volume of interest CBCT and tube current modulation for image guidance using dynamic kV collimation

Purpose: The focus of this work is the development of a novel blade collimation system enabling volume of interest (VOI) CBCT with tube current modulation using the kV image guidance source on a linear accelerator. Advantages of the system are assessed, particularly with regard to reduction and localization of dose and improvement of image quality. Methods: A four blade dynamic kV collimator was developed to track a VOI during a CBCT acquisition. The current prototype is capable of tracking an arbitrary volume defined by the treatment planner for subsequent CBCT guidance. During gantry rotation, the collimator tracks the VOI with adjustment of position and dimension. CBCT image quality was investigated as a function of collimator dimension, while maintaining the same dose to the VOI, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Dose distributions were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field CBCT distributions to quantify dose reduction and localization to the target volume. A novel method of optimizing x-ray tube current during CBCT acquisition was developed and assessed with regard to contrast-to-noise ratio (CNR) and imaging dose. Results: Measurements show that the VOI CBCT method using the dynamic blade system yields an increase in contrast-to-noise ratio by a factor of approximately 2.2. Depending upon the anatomical site, dose was reduced to 15%–80% of the full-field CBCT value along the central axis plane and down to less than 1% out of plane. The use of tube current modulation allowed for specification of a desired SNR within projection data. For approximately the same dose to the VOI, CNR was further increased by a factor of 1.2 for modulated VOI CBCT, giving a combined improvement of 2.6 compared to full-field CBCT. Conclusions: The present dynamic blade system provides significant improvements in CNR for the same imaging dose and localization of imaging dose to a predefined volume of interest. The approach is compatible with tube current modulation, allowing optimization of the imaging protocol.

60 APPLIED LIFE SCIENCES↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adjoint Waveform Tomography for Crustal and Upper Mantle Structure the Middle East and Southwest Asia for Improved Waveform Simulations Using Openly Available Broadband Data

We present a new model of radially anisotropic seismic wavespeeds for the crust and upper mantle of a broad region of the Middle East and Southwest Asia (MESWA) derived from adjoint waveform tomography. We inverted waveforms from 192 Global Centroid Moment Tensor earthquakes (MW 5.5-7.0) recorded by over 1000 openly available broadband seismic stations from permanent and temporary networks in the region. Spatial coverage of the available data is highly uneven due to earthquakes clustered along plate boundaries and sparse coverage of open seismic networks in the region. We considered three possible starting models: the SPiRaL global model (Simmons et al., 2021); MEC-1 (Kaviani et al., 2020); and CSEM2.0 (Noe et al., 2023). Because the SPiRaL model provides good fits to the observed waveforms measured by the time-bandwidth product of selected windows in several period bands, provides all the necessary parameters and covers the entire domain we used it for the starting model with the period band 50-100 seconds. Inversion iterations proceeded using time-frequency phase misfits in six stages and 54 total iterations reducing the minimum period to 30 seconds. Our final model, MESWA, provides improved waveform fits compared to the starting model for both the data used in the inversion and an independent validation data set of 66 events. Two metrics of waveform fit (the time-frequency phase misfit used in the optimization and normalized L2 misfit) were both reduced by nearly 60% for both data sets and MESWA provides significantly larger misfit reductions relative to the SPiRaL model than the MEC-1 or CSEM models. We also find that MESWA provides a larger time-bandwidth product of selected windows indicating that more information content of the observed waveforms is explained by MESWA than the other models. Our new model reveals tectonic features imaged by other studies and methods but in a new holistic model of shear and compressional wavespeeds (v S and v P , respectively) with anisotropy covering the crust and uppermost mantle of a larger domain. MESWA has smaller scale-length features and tends to sharpen some features relative to the SPiRaL starting model. Examples include: low crustal v S in the TurkishIranian Plateau, Zagros Mountains, Afghan Central Blocks and Sulaiman Fold Belt; low mantle vSfollowing divergent (Gulf of Aden, Red Sea) and transform (Dead Sea Fault) margins of the Arabian Plate; low and high v S in the mantle beneath the Arabian Shield and Platform, respectively. Low vS is imaged below Cenozoic volcanic centers of the Arabian Peninsula, the so-called Mecca-Madina-Nafud (MMN) Line. Positive anisotropy (v SH > v SV ) is inferred for asthenospheric depths across the region except where up/downwelling may influence fabric alignment (e.g. Afar, Red Sea, Arabian Shield). Elevated vS tracks Makran subduction under southeast Iran. MESWA resembles the SPiRaL model in its long-wavelength structure, but enhances shorter wavelengths features on the order of 200 km and smaller. The resulting model could be used for as a starting model for further improvements, say using waveforms from in-country seismic networks that are not openly available or smaller-scale studies targeting shorter period waveforms. The model also could be used for source characterization and moment tensor inversion to improve earthquake hazard studies and nuclear explosion monitoring.

58 GEOSCIENCES↗

Advances in building data management for building performance standards using the SEED platform

Reducing energy consumption and greenhouse gas emissions in the built environment is a critical step in achieving emission goals to mitigate climate change impacts. Local, federal, and international jurisdictions are deploying several methods to reduce energy and emissions such as voluntary and mandatory benchmarking and building performance standards, requiring building owners to reach energy and emission targets. Jurisdictions leveraging benchmarking and building performance standards require knowledge of the buildings covered; which is a large task due to staffing constraints, limited information on building characteristics and tax parcel data, and the need for advanced data management techniques to align datasets. This paper describes an open-source platform's recent advances to create consistent taxonomies, identify erroneous data, enable auditability, and track building performance. The paper concludes with two use cases on how the platform has been used by jurisdictions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-T-500: Initial Implementation of GPU-Based Particle Swarm Optimization for 4D IMRT Planning in Lung SBRT

Purpose 4D-IMRT planning, combined with dynamic MLC tracking delivery, utilizes the temporal dimension as an additional degree of freedom to achieve improved OAR-sparing. The computational complexity for such optimization increases exponentially with increase in dimensionality. In order to accomplish this task in a clinically-feasible time frame, we present an initial implementation of GPU-based 4D-IMRT planning based on particle swarm optimization (PSO). Methods The target and normal structures were manually contoured on ten phases of a 4DCT scan of a NSCLC patient with a 54cm3 right-lower-lobe tumor (1.5cm motion). Corresponding ten 3D-IMRT plans were created in the Eclipse treatment planning system (Ver-13.6). A vendor-provided scripting interface was used to export 3D-dose matrices corresponding to each control point (10 phases × 9 beams × 166 control points = 14,940), which served as input to PSO. The optimization task was to iteratively adjust the weights of each control point and scale the corresponding dose matrices. In order to handle the large amount of data in GPU memory, dose matrices were sparsified and placed in contiguous memory blocks with the 14,940 weight-variables. PSO was implemented on CPU (dual-Xeon, 3.1GHz) and GPU (dual-K20 Tesla, 2496 cores, 3.52Tflops, each) platforms. NiftyReg, an open-source deformable image registration package, was used to calculate the summed dose. Results The 4D-PSO plan yielded PTV coverage comparable to the clinical ITV-based plan and significantly higher OAR-sparing, as follows: lung Dmean=33%; lung V20=27%; spinal cord Dmax=26%; esophagus Dmax=42%; heart Dmax=0%; heart Dmean=47%. The GPU-PSO processing time for 14940 variables and 7 PSO-particles was 41% that of CPU-PSO (199 vs. 488 minutes). Conclusion Truly 4D-IMRT planning can yield significant OAR dose-sparing while preserving PTV coverage. The corresponding optimization problem is large-scale, non-convex and computationally rigorous. Our initial results indicate that GPU-based PSO with further software optimization can make such planning clinically feasible. This work was supported through funding from the National Institutes of Health and Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Risk Evaluation for CO2 Geosequestration in the Knox Supergroup, Illinois Basin Final Report

This report describes a process and provides seed information for identifying and evaluating risks pertinent to a hypothetical carbon dioxide (CO2) capture and sequestration (CCS) project. In the envisioned project, the target sequestration reservoir rock is the Potosi Formation of the Knox Supergroup. The Potosi is identified as a potential target formation because (1) at least locally, it contains vuggy to cavernous layers that have very high porosity, and (2) it is present in areas where the deeper Mt. Simon Sandstone (a known potential reservoir unit) is absent or nonporous. The key report content is discussed in Section 3.3, which describes two lists of Features, Events, and Processes (FEPs) that should be considered during the design stage of such a project. These lists primarily highlight risk elements particular to the establishment of the Potosi as the target formation in general. The lists are consciously incomplete with respect to risk elements that would be relevant for essentially all CCS projects regardless of location or geology. In addition, other risk elements specific to a particular future project site would have to be identified. Sources for the FEPs and scenarios listed here include the iconic Quintessa FEPs list developed for the International Energy Agency Greenhouse Gas (IEAGHG) Programme; previous risk evaluation projects executed by Schlumberger Carbon Services; and new input solicited from experts currently working on aspects of CCS in the Knox geology. The projects used as sources of risk information are primarily those that have targeted carbonate reservoir rocks similar in age, stratigraphy, and mineralogy to the Knox-Potosi. Risks of using the Potosi Formation as the target sequestration reservoir for a CCS project include uncertainties about the levels of porosity and permeability of that rock unit; the lateral consistency and continuity of those properties; and the ability of the project team to identify suitable (i.e., persistently porous and permeable) injection depths within the overall formation. Less direct implications include the vertical position of the Potosi within the rock column and the absence of a laterally extensive shale caprock immediately overlying the Potosi. Based on modeling work done partly in association with this risk report, risks that should also be evaluated include the ability of available methods to predict and track the development of a CO2 plume as it migrates away from the injection point(s). The geologic and hydrodynamic uncertainties present risks that are compounded at the stage of acquiring necessary drilling and injection permits. It is anticipated that, in the future, a regional geologic study or CO2-emitter request may identify a small specific area as a prospective CCS project site. At that point, the FEPs lists provided in this report should be evaluated by experts for their relative levels of risk. A procedure for this evaluation is provided. The higher-risk FEPs should then be used to write project-specific scenarios that may themselves be evaluated for risk. Then, actions to reduce and to manage risk can be described and undertaken. The FEPs lists provided as Appendix 2 should not be considered complete, as potentially the most important risks are ones that have not yet been thought of. But these lists are intended to include the most important risk elements pertinent to a Potosi-target CCS project, and they provide a good starting point for diligent risk identification, evaluation, and management.

Hnottavange-Telleen, Ken↗

Risk Evaluation for CO 2 Geosequestration in the Knox Supergroup, Illinois Basin (Final Report)

This report describes a process and provides seed information for identifying and evaluating risks pertinent to a hypothetical carbon dioxide (CO 2 ) capture and sequestration (CCS) project. In the envisioned project, the target sequestration reservoir rock is the Potosi Formation of the Knox Supergroup. The Potosi is identified as a potential target formation because (1) at least locally, it contains vuggy to cavernous layers that have very high porosity, and (2) it is present in areas where the deeper Mt. Simon Sandstone (a known potential reservoir unit) is absent or nonporous. The key report content is discussed in Section 3.3, which describes two lists of Features, Events, and Processes (FEPs) that should be considered during the design stage of such a project. These lists primarily highlight risk elements particular to the establishment of the Potosi as the target formation in general. The lists are consciously incomplete with respect to risk elements that would be relevant for essentially all CCS projects regardless of location or geology. In addition, other risk elements specific to a particular future project site would have to be identified. Sources for the FEPs and scenarios listed here include the iconic Quintessa FEPs list developed for the International Energy Agency Greenhouse Gas (IEAGHG) Programme; previous risk evaluation projects executed by Schlumberger Carbon Services; and new input solicited from experts currently working on aspects of CCS in the Knox geology. The projects used as sources of risk information are primarily those that have targeted carbonate reservoir rocks similar in age, stratigraphy, and mineralogy to the Knox-Potosi. Risks of using the Potosi Formation as the target sequestration reservoir for a CCS project include uncertainties about the levels of porosity and permeability of that rock unit; the lateral consistency and continuity of those properties; and the ability of the project team to identify suitable (i.e., persistently porous and permeable) injection depths within the overall formation. Less direct implications include the vertical position of the Potosi within the rock column and the absence of a laterally extensive shale caprock immediately overlying the Potosi. Based on modeling work done partly in association with this risk report, risks that should also be evaluated include the ability of available methods to predict and track the development of a CO 2 plume as it migrates away from the injection point(s). The geologic and hydrodynamic uncertainties present risks that are compounded at the stage of acquiring necessary drilling and injection permits. It is anticipated that, in the future, a regional geologic study or CO 2 -emitter request may identify a small specific area as a prospective CCS project site. At that point, the FEPs lists provided in this report should be evaluated by experts for their relative levels of risk. A procedure for this evaluation is provided. The higher-risk FEPs should then be used to write project-specific scenarios that may themselves be evaluated for risk. Then, actions to reduce and to manage risk can be described and undertaken. The FEPs lists provided as Appendix 2 should not be considered complete, as potentially the most important risks are ones that have not yet been thought of. But these lists are intended to include the most important risk elements pertinent to a Potosi-target CCS project, and they provide a good starting point for diligent risk identification, evaluation, and management.

54 ENVIRONMENTAL SCIENCES↗

DEVELOPING THE PHYSICS DESIGN FOR NDCX-II, A UNIQUE PULSE-COMPRESSING ION ACCELERATOR

The Heavy Ion Fusion Science Virtual National Laboratory(a collaboration of LBNL, LLNL, and PPPL) is using intense ion beams to heat thin foils to the"warm dense matter" regime at<~;; 1 eV, and is developing capabilities for studying target physics relevant to ion-driven inertial fusion energy. The need for rapid target heating led to the development of plasma-neutralized pulse compression, with current amplification factors exceeding 50 now routine on the Neutralized Drift Compression Experiment (NDCX). Construction of an improved platform, NDCX-II, has begun at LBNL with planned completion in 2012. Using refurbished induction cells from the Advanced Test Accelerator at LLNL, NDCX-II will compress a ~;;500 ns pulse of Li+ ions to ~;;1 ns while accelerating it to 3-4 MeV over ~;;15 m. Strong space charge forces are incorporated into the machine design at a fundamental level. We are using analysis, an interactive 1D PIC code (ASP) with optimizing capabilities and centroid tracking, and multi-dimensional Warpcode PIC simulations, to develop the NDCX-II accelerator. This paper describes the computational models employed, and the resulting physics design for the accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method

The authors present a segment-based convolution method to account for the interplay effect between intrafraction organ motion and the multileaf collimator position for each particular segment in intensity modulated radiation therapy (IMRT) delivered in a step-and-shoot manner. In this method, the static dose distribution attributed to each segment is convolved with the probability density function (PDF) of motion during delivery of the segment, whereas in the conventional convolution method (''average-based convolution''), the static dose distribution is convolved with the PDF averaged over an entire fraction, an entire treatment course, or even an entire patient population. In the case of IMRT delivered in a step-and-shoot manner, the average-based convolution method assumes that in each segment the target volume experiences the same motion pattern (PDF) as that of population. In the segment-based convolution method, the dose during each segment is calculated by convolving the static dose with the motion PDF specific to that segment, allowing both intrafraction motion and the interplay effect to be accounted for in the dose calculation. Intrafraction prostate motion data from a population of 35 patients tracked using the Calypso system (Calypso Medical Technologies, Inc., Seattle, WA) was used to generate motion PDFs. These were then convolved with dose distributions from clinical prostate IMRT plans. For a single segment with a small number of monitor units, the interplay effect introduced errors of up to 25.9% in the mean CTV dose compared against the planned dose evaluated by using the PDF of the entire fraction. In contrast, the interplay effect reduced the minimum CTV dose by 4.4%, and the CTV generalized equivalent uniform dose by 1.3%, in single fraction plans. For entire treatment courses delivered in either a hypofractionated (five fractions) or conventional (>30 fractions) regimen, the discrepancy in total dose due to interplay effect was negligible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗