Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Altered excitation energy transfer between phycobilisome and photosystems in the absence of ApcG, a small linker peptide, in Synechocystis sp. PCC 6803, a cyanobacterium

Phycobilisome (PBS) is a large pigment-protein complex in cyanobacteria and red algae responsible for capturing sunlight and transferring its energy to photosystems (PS). Spectroscopic and structural properties of various PBSs have been widely studied, however, the nature of so-called complex-complex interactions between PBS and PSs remains much less explored. In this work, we have investigated the function of a newly identified PBS linker protein, ApcG, some domain of which, together with a loop region (PB-loop in ApcE), is possibly located near the PBS-PS interface. Using Synechocystis sp. PCC 6803, we generated an ApcG deletion mutant and probed its deletion effect on the energetic coupling between PBS and photosystems. Steady-state and time-resolved spectroscopic characterization of the purified ΔApcG-PBS demonstrated that ApcG removal weakly affects the photophysical properties of PBS that the spectroscopic properties of terminal energy emitters are comparable to those of PBS from wild-type. However, analysis of fluorescence decay imaging datasets reveals that ApcG deletion induces disruptions within the allophycocyanin (APC) core, resulting in the emergence (splitting) of two spectrally diverse subgroups with some short-lived APC. Profound spectroscopic changes of the whole ΔApcG mutant cell, however, emerge during state transition, a dynamic process of light scheme adaptation. The mutant cells in State I show a substantial increase in PBS-related fluorescence. On the other hand, global analysis of time-resolved fluorescence demonstrates that in general ApcG deletion does not alter or inhibit state transitions if it is interpreted only in terms of the changes of the PSII and PSI fluorescence emission intensity. Furthermore, the results revealed yet–to–be discovered mechanism of ApcG-docking induced excitation energy transfer regulation within PBS or to Photosystems.

59 BASIC BIOLOGICAL SCIENCES↗

Visualizing deceleration-phase instabilities in inertial confinement fusion implosions using an “enhanced self-emission” technique at the National Ignition Facility

High-mode perturbations and low-mode asymmetries were measured in the deceleration phase of indirectly-driven, deuterium gas filled inertial confinement fusion (ICF) capsule implosions at convergence ratios of 10 to 15, using a new “enhanced emission” technique at the National Ignition Facility (NIF) [E. M. Campbell, R. Cauble, and B. A. Remington, AIP Conf. Proc. 429, 3 (1998)]. In these experiments, a high spatial resolution Kirkpatrick-Baez microscope was used to image the x-ray emission from the inner surface of a high-density-carbon (HDC) capsule’s shell. Use of a high atomic number dopant in the shell enabled time-resolved observations of shell perturbations penetrating into the hot spot. This allowed the effects of the perturbations and asymmetries on degrading neutron yield to be directly measured. In particular, mix induced radiation losses of ~400 J from the hot spot resulted in a neutron yield reduction of a factor of ~2. In a subsequent experiment with a significantly increased level of short-mode initial perturbations, shown through the enhanced imaging technique to be highly organized radially, the neutron yield dropped an additional factor of ~2.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast dynamics of fluorene initiated by highly intense laser fields

Here, we present an investigation of the ultrafast dynamics of the polycyclic aromatic hydrocarbon fluorene initiated by an intense femtosecond near-infrared laser pulse (810 nm) and probed by a weak visible pulse (405 nm). Using a multichannel detection scheme (mass spectra, electron and ion velocity-map imaging), we provide a full disentanglement of the complex dynamics of the vibronically excited parent molecule, its excited ionic states, and fragments. We observed various channels resulting from the strong-field ionization regime. In particular, we observed the formation of the unstable tetracation of fluorene, above-threshold ionization features in the photoelectron spectra, and evidence of ubiquitous secondary fragmentation. We produced a global fit of all observed time-dependent photoelectron and photoion channels. This global fit includes four parent ions extracted from the mass spectra, 15 kinetic-energy-resolved ionic fragments extracted from ion velocity map imaging, and five photoelectron channels obtained from electron velocity map imaging. The fit allowed for the extraction of 60 lifetimes of various metastable photoinduced intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Incremental growth of short SWNT arrays by pulsed chemical vapor deposition

Very short, aligned arrays of continuous single wall carbon nanotubes were grown incrementally in steps as small as 25 nm using pulsed chemical vapor deposition. In situ optical extinction measurements indicate that over 98% of the nanotubes reinitiate growth on successive gas pulses, and HRTEM images show that the SWNTs do not exhibit segments, caps, or noticeable sidewall defects resulting from repeatedly stopping and restarting growth. Time-resolved laser reflectivity (3-ms temporal resolution) was used to record the nucleation and growth kinetics for each fast (0.2 second) gas pulse and measure the height increase of the array in situ, providing a "digital" method to incrementally grow short nanotube arrays to precise heights. Derivatives of the optical reflectivity signal reveal distinct temporal signatures for both nucleation and growth kinetics, with their amplitude ratio on the first gas pulse serving as a good predictor for aligned vs. unaligned growth. Incremental growth by pulsed CVD is interpreted in the context of autocatalytic kinetic models as a special processing window in which a sufficiently high flux of feedstock gas drives the nucleation and rapid growth phases of a catalyst nanoparticle ensemble to occur within the temporal period of the gas pulse, but without inducing growth termination.

36 MATERIALS SCIENCE↗

A microfluidic spore chamber for long-term imaging of single-spore hyphal development.

Understanding the life cycle of fungal spores is essential for elucidating their roles in pathogenesis, dispersal, and survival. However, studying spore development under controlled, spatially defined conditions remains challenging. Here, we present the Spore Chamber, a custom-built microfluidic platform engineered for parallel trapping and long-term imaging of individual spores under defined media conditions, enabling real-time visualization of hyphal development. Using Aspergillus fumigatus as a model organism, we demonstrate that sparse trapping of individual spores within size-matched trap geometries enables long-term time-lapse imaging of key developmental stages, including germination, polarized hyphal elongation, branching, and conidiophore formation. To assess the device's capacity to resolve morphogenetic responses to exogenous signals, we introduced lipochitooligosaccharides (LCOs) and short-chain chitooligosaccharides (COs). Rhizobium-derived, non-sulfated LCO (nsLCO) mixtures induced enhanced secondary branching (hyperbranching), a response not previously reported in A. fumigatus under these signal conditions, to our knowledge, whereas sulfated LCOs and CO4 did not significantly alter branching patterns. In addition, long-term confinement and imaging revealed rare developmental morphologies previously described primarily in mutant strains, including split conidiophore formation, elongated phialides, and stress-associated phenomena such as microcyclic conidiation, and chlamydospore development. Together, these results establish the Spore Chamber as a targeted microfluidic platform for single-spore phenotyping and long-term developmental analysis, with applications in fungal biology, chemical signaling studies, and host–microbe interaction research.

Antifungal screening↗

Spatially co-registered wide-field nonlinear optical imaging of living and complex biosystems in a total internal reflection geometry

Nonlinear optical microscopy that leverages an objective based total internal reflection (TIR) excitation scheme is an attractive means for rapid, wide-field imaging with enhanced surface sensitivity. Through select combinations of distinct modalities, one can, in principle, access complementary chemical and structural information for various chemical species near interfaces. Here, we report a successful implementation of such a wide-field nonlinear optical microscope system, which combines coherent anti-Stokes Raman scattering (CARS), two-photon fluorescence (TPF), second harmonic generation (SHG), and sum frequency generation (SFG) modalities on the same platform. The intense optical fields needed to drive these high order nonlinear optical processes are achieved through the use of femtosecond pulsed light in combination with the intrinsic field confinement induced by TIR over a large field of view. The performance of our multimodal microscope was first assessed through the experimental determination of its chemical fidelity, intensity and polarization dependences, and spatial resolution using a set of well-defined model systems. Subsequently, its unique capabilities were validated through imaging complex biological systems, including Hydrangea quercifolia pollen grains and Pantoea sp. YR343 bacterial cells. Specifically, the spatial distribution of different molecular groups in the former was visualized via vibrational contrast mechanisms of CARS, whereas co-registered TPF imaging allowed the identification of spatially localized intrinsic fluorophores. We further demonstrate the feasibility of our microscope for wide-field CARS imaging on live cells through independent characterization of cell viability using spatially co-registered TPF imaging. Overall, this approach to TIR enabled wide-field imaging is expected to provide new insights into bacterial strains and their interactions with other species in the rhizosphere in a time-resolved and chemically selective manner.

47 OTHER INSTRUMENTATION↗

Monte Carlo calculations of PET coincidence timing: single and double-ended readout

We present Monte Carlo computational methods for estimating the coincidence resolving time (CRT) of scintillator detector pairs in positron emission tomography (PET) and present results for Lu 2 SiO 5 : Ce (LSO), LaBr 3 : Ce, and a hypothetical ultra-fast scintillator with a 1 ns decay time. The calculations were applied to both single-ended and double-ended photodetector readout with constant-fraction triggering. They explicitly include (1) the intrinsic scintillator properties (luminosity, rise time, decay time, and index of refraction), (2) the exponentially distributed depths of interaction, (3) the optical photon transport efficiency, delay, and time dispersion, (4) the photodetector properties (fill factor, quantum efficiency, transit time jitter, and single electron response), and (5) the determination of the constant fraction trigger level that minimizes the CRT. The calculations for single-ended readout include the delayed photons from the opposite reflective surface. The calculations for double-ended readout include (1) the simple average of the two photodetector trigger times, (2) more accurate estimators of the annihilation photon entrance time using the pulse height ratio to estimate the depth of interaction and correct for annihilation photon, optical photon, and trigger delays, and (3) the statistical lower bound for interactions at the center of the crystal. For time-of-flight (TOF) PET we combine stopping power and TOF information in a figure of merit equal to the sensitivity gain relative to whole-body non-TOF PET using LSO. For LSO crystals 3 mm × 3 mm × 30 mm, a decay time of 37 ns, a total photoelectron count of 4000, and a photodetector with 0.2 ns full-width at half-maximum (fwhm) timing jitter, single-ended readout has a CRT of 0.16 ns fwhm and double-ended readout has a CRT of 0.111 ns fwhm. For LaBr 3 : Ce crystals 3 mm × 3 mm × 30 mm, a rise time of 0.2 ns, a decay time of 18 ns, and a total of 7600 photoelectrons the CRT numbers are 0.14 ns and 0.072 ns fwhm, respectively. For a hypothetical ultra-fast scintillator 3 mm × 3 mm × 30 mm, a decay time of 1 ns, and a total of 4000 photoelectrons, the CRT numbers are 0.070 and 0.020 ns fwhm, respectively. Over a range of examples, values for double-ended readout are about 10% larger than the statistical lower bound.

Monte Carlo↗

Dataset for "A Microfluidic Spore Chamber for Long-Term Imaging of Single-Spore Hyphal Development"

Understanding the life cycle of fungal spores is essential for elucidating their roles in pathogenesis, dispersal, and survival. However, studying spore development under controlled, spatially defined conditions remains challenging. Here, we present the Spore Chamber, a custom-built microfluidic platform engineered for parallel trapping and long-term imaging of individual spores under defined media conditions, enabling real-time visualization of hyphal development. Using Aspergillus fumigatus as a model organism, we demonstrate that sparse trapping of individual spores within size-matched trap geometries enables long-term time-lapse imaging of key developmental stages, including germination, polarized hyphal elongation, branching, and conidiophore formation. To assess the device’s capacity to resolve morphogenetic responses to exogenous signals, we introduced lipochitooligosaccharides (LCOs) and short-chain chitooligosaccharides (COs). Rhizobium-derived, non-sulfated LCO (nsLCO) mixtures induced enhanced secondary branching (hyperbranching), a response not previously reported in A. fumigatus under these signal conditions, to our knowledge, whereas sulfated LCOs and CO4 did not significantly alter branching patterns. In addition, long-term confinement and imaging revealed rare developmental morphologies previously described primarily in mutant strains, including split conidiophore formation, elongated phialides, microcyclic conidiation, and chlamydospore development. Together, these results establish the Spore Chamber as a targeted microfluidic platform for single-spore phenotyping and long-term developmental analysis, with applications in fungal biology, chemical signaling studies, and host–microbe interaction research. Videos of the observed phenomena are included in this data set.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Three-dimensional reconstruction and display of the heart, lungs and circulation by multiplanar X-ray scanning videodensitometry

A device was developed which makes possible the dynamic reconstruction of the heart and lungs within the intact thorax of a living dog or human and which can record approximately 30 multiplanar X-ray images of the thorax practically instantaneously, and at frequent enough intervals of time and with sufficient density and spatial resolution to capture and resolve the most rapid changes in cardiac structural detail throughout each cardiac cycle. It can be installed in a clinical diagnostic setting as well as in a research environment and its construction and application for determination and display in real-time modes of cross sections of the functioning thorax and its contents of living animals and man is technologically feasible.

Robb, R. A.↗

SUMER: Solar Ultraviolet Measurements of Emitted Radiation

The SUMER (solar ultraviolet measurements of emitted radiation) experiment is described. It will study flows, turbulent motions, waves, temperatures and densities of the plasma in the upper atmosphere of the Sun. Structures and events associated with solar magnetic activity will be observed on various spatial and temporal scales. This will contribute to the understanding of coronal heating processes and the solar wind expansion. The instrument will take images of the Sun in EUV (extreme ultra violet) light with high resolution in space, wavelength and time. The spatial resolution and spectral resolving power of the instrument are described. Spectral shifts can be determined with subpixel accuracy. The wavelength range extends from 500 to 1600 angstroms. The integration time can be as short as one second. Line profiles, shifts and broadenings are studied. Ratios of temperature and density sensitive EUV emission lines are established.

Wilhelm, K.↗

GRIS observations of the Galactic Center

The 511 keV positron annihilation line source in the Galactic Center (GC) region has reappeared after being in a quiescent state since the early 1980's. Observations are reported made by the GRIS balloon instrument showing that the 511 keV line has returned to an intensity level similar to that seen in the 1970's. The line width was resolved for the first time and a measurement of the spatial extent of the emission along the galactic plane was made. Gamma ray imaging spectrometer (GRIS) is a high resolution germanium (Ge) spectrometer with a 17 deg field-of-view. Eleven hours of data were obtained from GC pointings on balloon flights over Australia on 1 May 1988 and again on 29 October 1988. An additional seven hours were obtained on 30 October 1988 from a point in the galactic plane (GP) 25 deg west of the center. Preliminary results for the line fluxes from the GC are 9.8 + or - 1.9 in May and 12.3 + or - 1.6 in October, and from the GP are 2.4 + or - 1.6 (1 sigma statistical errors). The flux for the off-center pointing is significantly lower than that for the GC pointings and indicates that the dominant emission is narrowly concentrated at the center. The line width for the GC pointing in October is 3.6 + or - 0.5 keV, which implies a temperature for the annihilation medium of less than or + 10(exp 5)K. A step in the continuum emission at 511 keV is found in both the GC and GP data. The step may be due to orthopositronium three-photon annihilation for the GC, but is too large relative to the 511 keV line for the GP to be simply explained by positronium.

Gehrels, N.↗

Excited Ejecta in Light of Sight from Eta Car

In the NUV spectrum of Eta Car, we have resolved many narrow absorption lines of neutral and singly-ionized elements with the Space Telescope Imaging Spectrograph. We report for the first time the detection of interstellar vanadium in absorption, and many highly-excited absorption lines of Fe, Cr, Ti, Ni, Co, Mn, and Mg. These elements, normally tied up in dust grains in the ISM, are located within wall of the Homunculus within 20,000 A.U. of Eta Car. Stellar radiation and stellar wind are interacting with the wall. Dust is likely being modified and/or destroyed. Previous Homunculus studies have demonstrated that nitrogen is overabundant and that carbon and oxygen emission lines are weak, or non-existent. Are the large column densities of these heavy elements due to abundance effects, excitation mechanisms, or modified grains? We may gain insight as Eta Car goes through its spectroscopic minimum in the summer of 2003.

Vieira, G.↗

Subframe Burst Gating for Raman Spectroscopy in Combustion

We describe an architecture for spontaneous Raman scattering utilizing a frame-transfer CCD sensor operating in a subframe burst-gating mode to realize time-resolved combustion diagnostics. The technique permits all-electronic optical gating with microsecond shutter speeds 5 J.Ls) without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally polarized excitation lasers, the technique measures single-shot vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

Kojima, Jun↗

Porous Microstructure Analysis (PuMA) software

The Porous Microstructure Analysis (PuMA) software was developed to provide a robust and efficient framework for computing material properties based on their microstructures. The development was motivated by advancements in X-ray microtomography, an imaging technology that can resolve the structure of a material at a sub-micron scale, in 3D and even in 4D (over time). PuMA provides the capability of computing a comprehensive spectrum of properties, from the most fundamental geometric features of a microstructure, to advanced anisotropic thermo-elastic properties. In addition, the software can generate artificial microstructures, ranging from simple analytical shapes to complex fibrous woven and non- woven geometries, which can be used in performance optimization studies. This presentation will highlight many of the capabilities of the recent open-source release.

microtomography↗

Label-free time- and space-resolved exometabolite sampling of growing plant roots through nanoporous interfaces

Abstract Spatial and temporal profiling of metabolites within and between living systems is vital to understanding how chemical signaling shapes the composition and function of these complex systems. Measurement of metabolites is challenging because they are often not amenable to extrinsic tags, are diverse in nature, and are present with a broad range of concentrations. Moreover, direct imaging by chemically informative tools can significantly compromise viability of the system of interest or lack adequate resolution. Here, we present a nano-enabled and label-free imaging technology using a microfluidic sampling network to track production and distribution of chemical information in the microenvironment of a living organism. We describe the integration of a polyester track-etched (PETE) nanofluidic interface to physically confine the biological sample within the model environment, while allowing fluidic access via an underlying microfluidic network. The nanoporous interface enables sampling of the microenvironment above in a time-dependent and spatially-resolved manner. For demonstration, the diffusional flux through the PETE membrane was characterized to understand membrane performance, and exometabolites from a growing plant root were successfully profiled in a space- and time-resolved manner. This method and device provide a frame-by-frame description of the chemical environment that maps to the physical and biological characteristics of the sample.

59 BASIC BIOLOGICAL SCIENCES↗

Long duration x-ray source development for x-ray diffraction at the National Ignition Facility

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

Werellapatha, K. (ORCID:0000000293154054)↗

Grain-Size-Limited Mobility in Methylammonium Lead Iodide Perovskite Thin Films

We report a systematic study of the gigahertz-frequency charge carrier mobility found in methylammonium lead iodide perovskite films as a function of average grain size using time-resolved microwave conductivity and a single processing chemistry. Our measurements are in good agreement with the Kubo formula for the AC mobility of charges confined within finite grains, suggesting (1) that the surface grains imaged via scanning electron microscopy are representative of the true electronic domain size and not substantially subdivided by twinning or other defects not visible by microscopy and (2) that the time scale of diffusive transport across grain boundaries is much slower than the period of the microwave field in this measurement (-100 ps). The intrinsic (infinite grain size) minimum mobility extracted form the model is 29 +/- 6 cm2 V-1 s-1 at the probe frequency (8.9 GHz).

36 MATERIALS SCIENCE↗