Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

SU-E-T-639: A Study On the Response of 2D Array Detector for VMAT Delivery for a Period of Two Years

Purpose: To evaluate the 2D array for radiation response for a period of 2 years. Methods: 45 VMAT plans already treated and quality assured before 2 years, 1.5 years and 1 year were selected for the study. Quality assurances of the plans were done using 2D array combined with Octavius phantom. Verification plans were recalculated without changing any parameters in Eclipse 10.0 TPS using the AAA algorithm. Response of 2D array to the plans treated before 2 years, 1.5 years and 1 year where evaluated. The results were analyzed using the Gamma analysis method with the standard gamma passing criteria of 3mm distance to agreement (DTA) and 3% dose difference (DD). Results: All the plans evaluated passed the gamma analysis with a percentage greater than 95, except for three cases. Higher gamma passing criteria where observed for all the analyzed plans, when analysis done before 2 years, 1.5 years and 1 year. The standard deviation of ± 1.38, ± 1.40,± 0.97 where observed between the plans when verification plans did before 2 years, 1.5 years and 1 year respectively. Same set of plans shows a standard deviation of ± 0.70, ± 1.36, and ± 1.18, when analysis done recently. A significance difference in response of the array when analysis done recently for the verification plans treated and quality assured before 2 years.This indicates a slightly reduced response of 2D array towards radiation response as the array gets older. Conclusion: It is found that 2D array shows a reduced response against radiation detection over a period of years. An onsite calibration of the instrument is recommended before the measurements. A dose correction factor can be applied if necessary to the results if the radiation response and efficiency of the array is very poor.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-434: Fixed Margin Or Online Adaptation for Intermediate-Risk Prostate Stereotactic Body Radiation Therapy? A Dosimetric Study

Purpose: To investigate the choice of fixed margin or online adaptation when treating intermediate-risk prostate cancer including seminal vesicles (SV) using stereotactic body radiation therapy (SBRT). Methods: 9 prostate SBRT patients were retrospectively studied. All patients were implanted with fiducial markers in the prostate for daily localization and verification. Each patient had 5 pairs of pre-treatment and post-treatment cone-beam CT (CBCT) per protocol. SVs were contoured on planning CT and all CBCTs by one attending physician. Simultaneous integral boost (SIB) IMRT plans were developed to deliver 25Gy/5fx to the SV while delivering 37Gy/5fx to the prostate. A 3mm isotropic margin was added to the prostate while a 5 mm isotropic margin was used for the SV. The planning CT was registered to daily pre-treatment and post-treatment CBCT based on fiducial markers in the prostate to mimic online prostate localization; and the SV on daily CBCT was transferred to the CT structure set after the prostates were aligned. Daily pre-treatment and post-treatment SV dose coverage and the organ-at-risk (OAR) sparing were evaluated for the SIB regimen. At least 95% of the SV need to receive the prescription dose (5Gy per fraction). Results: For the total of 90 daily SVs analyzed (ten CBCTs for each of nine patients), only 45 daily SVs (50%) were able to meet the coverage that 95% of the SV received 25Gy. The OAR sparing performance was acceptable for most of the dosimetric constraints in low-risk prostate SBRT protocol with only two exceptions in bladder V100 (cc). Conclusion: A fixed 5mm margin for SV is not sufficient to provide consistent daily dose coverage due to SV’s substantial inter- and intra-fractional motion relative to the prostate. This finding calls for innovative strategies in margin design as well as online treatment adaptation. This work is partially supported a master research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

BuildingIQ Technology Field Validation

This document describes a field validation and verification of the BuildingIQ Predictive Energy Optimization (PEO) technology based on a five-site study. BuildingIQ describes its PEO technology as a software-as-a-service (SaaS) platform that optimizes commercial building HVAC control for system efficiency, occupant comfort, and cost. It is targeted for use in large, complex buildings, and integrates with the building automation system (BAS) to conduct supervisory control. The PEO algorithm defines optimal space air temperature setpoints that are automatically implemented at the variable air volume (VAV) terminal units when possible, or through supply air temperature and duct static pressure setpoints at the air handling unit (AHU) level. The optimization is built upon a learned predictive model that provides a 24-hour ahead forecast of the building’s power profile, using weather forecasts and historical operational data; this model is updated every 4 to 6 hours. Demand-responsive load reductions may also be implemented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BuildingIQ Technology Field Validation

This document describes a field validation and verification of the BuildingIQ Predictive Energy Optimization (PEO) technology based on a five-site study. BuildingIQ describes its PEO technology as a software-as-a-service (SaaS) platform that optimizes commercial building HVAC control for system efficiency, occupant comfort, and cost. It is targeted for use in large, complex buildings, and integrates with the building automation system (BAS) to conduct supervisory control. The PEO algorithm defines optimal space air temperature setpoints that are automatically implemented at the variable air volume (VAV) terminal units when possible, or through supply air temperature and duct static pressure setpoints at the air handling unit (AHU) level. The optimization is built upon a learned predictive model that provides a 24-hour ahead forecast of the building’s power profile, using weather forecasts and historical operational data; this model is updated every 4 to 6 hours. Demand-responsive load reductions may also be implemented.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Modeling and Simulation Capability For Full Scale Multi-Physics Simulation and Visualization of Microreactor Concept

Microreactors are small mobile transportable nuclear reactors with thermal power less than 20 MWt that are designed to meet the needs of remote areas, military installations, emergency operations, and disaster relief zones. These reactor are concepts that are intended to be factory-manufacturable, easily transportable, and will allow for semi- or full-autonomous operation. To assist with development of microreactors, modeling and experimentation need to be performed with verification and validation to gain confidence in the models and tools. The objective of this study is apply advanced modeling and simulation capabilities being developed by the DOE Office of Nuclear Energy Nuclear Energy Advanced Modeling and Simulation (NEAMS) program to perform integrated modeling and simulation capability for multiphysics simulation of the microreactor concepts. This activity will provide an opportunity to exercise the codes to provide both gain experience and to provide feedback to the developers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An overview of key technology thrusts at Bell Helicopter Textron

Insight is provided into several key technologies at Bell. Specific topics include the results of ongoing research and development in advanced rotors, methodology development, and new configurations. The discussion on advanced rotors highlight developments on the composite, bearingless rotor, including the development and testing of full scale flight hardware as well as some of the design support analyses and verification testing. The discussion on methodology development concentrates on analytical development in aeromechanics, including correlation studies and design application. New configurations, presents the results of some advanced configuration studies including hardware development.

Harse, James H.↗

Test and analysis procedures for updating math models of Space Shuttle payloads

Over the next decade or more, the Space Shuttle will continue to be the primary transportation system for delivering payloads to Earth orbit. Although a number of payloads have already been successfully carried by the Space Shuttle in the payload bay of the Orbiter vehicle, there continues to be a need for evaluation of the procedures used for verifying and updating the math models of the payloads. The verified payload math models is combined with an Orbiter math model for the coupled-loads analysis, which is required before any payload can fly. Several test procedures were employed for obtaining data for use in verifying payload math models and for carrying out the updating of the payload math models. Research was directed at the evaluation of test/update procedures for use in the verification of Space Shuttle payload math models. The following research tasks are summarized: (1) a study of free-interface test procedures; (2) a literature survey and evaluation of model update procedures; and (3) the design and construction of a laboratory payload simulator.

Craig, Roy R., Jr.↗

Projects in an expert system class

Many universities now teach courses in expert systems. In these courses students study the architecture of an expert system, knowledge acquisition techniques, methods of implementing systems and verification and validation techniques. A major component of any such course is a class project consisting of the design and implementation of an expert system. Discussed here are a number of techniques that we have used at the University of Texas at Tyler to develop meaningful projects that could be completed in a semester course.

Whitson, George M.↗

Free-free and fixed base modal survey tests of the Space Station Common Module Prototype

This paper describes the testing aspects and the problems encountered during the free-free and fixed base modal surveys completed on the original Space Station Common Module Prototype (CMP). The CMP is a 40-ft long by 14.5-ft diameter 'waffle-grid' cylinder built by the Boeing Company and housed at the Marshall Space Flight Center (MSFC) near Huntsville, AL. The CMP modal survey tests were conducted at MSFC by the Dynamics Test Branch. The free-free modal survey tests (June '90 to Sept. '90) included interface verification tests (IFVT), often referred to as impedance measurements, mass-additive testing and linearity studies. The fixed base modal survey tests (Feb. '91 to April '91), including linearity studies, were conducted in a fixture designed to constrain the CMP in 7 total degrees-of-freedom at five trunnion interfaces (two primary, two secondary, and the keel). The fixture also incorporated an airbag off-load system designed to alleviate the non-linear effects of friction in the primary and secondary trunnion interfaces. Numerous test configurations were performed with the objective of providing a modal data base for evaluating the various testing methodologies to verify dynamic finite element models used for input to coupled load analysis.

Driskill, T. C.↗

Treatment of Transient Pressure Events in Space Flight Pressurized Systems

The general physics of pressure transients, sources of pressure transients, and major factors influencing pressure transients are addressed. Mitigation strategies that aid in reducing the magnitude of pressure transients are discussed. Methods to characterize pressure transients and their effects on the structure are presented. Case studies illustrate the structural analysis methodology used to predict the structural dynamic response. The structural verification process involves formulating acceptance and qualification programs, which requires knowledge of the stress state. The maximum expected operating pressure (MEOP) is established such that the maximum stress produced by static pressure is equivalent to the maximum stress at the same critical location produced by the combined effect of steady state pressure and the magnitude of the pressure transient. A roadmap on how to treat transient pressures in the structural verification process of spaceflight pressurized systems (e.g., valves, lines, pressure vessels, pressurized structures) is presented.

Transient Pressure Events↗

WE-F-16A-06: Using 3D Printers to Create Complex Phantoms for Dose Verification, Quality Assurance, and Treatment Planning System Commissioning in Radiotherapy

Purpose: To use 3D printers to design and construct complex geometrical phantoms for commissioning treatment planning systems, dose calculation algorithms, quality assurance (QA), dose delivery, and patient dose verifications. Methods: In radiotherapy, complex geometrical phantoms are often required for dose verification, dose delivery and calculation algorithm validation. Presently, fabrication of customized phantoms is limited due to time, expense and challenges in machining of complex shapes. In this work, we designed and utilized 3D printers to fabricate two phantoms for QA purposes. One phantom includes hills and valleys (HV) for verification of intensity modulated radiotherapy for photons, and protons (IMRT and IMPT). The other phantom includes cylindrical cavities (CC) of various sizes for dose verification of inhomogeneities. We evaluated the HV phantoms for an IMPT beam, and the CC phantom to study various inhomogeneity configurations using photon, electron, and proton beams. Gafcromic ™ films were used to quantify the dose distributions delivered to the phantoms. Results: The HV phantom has dimensions of 12 cm × 12 cm and consists of one row and one column of five peaks with heights ranging from 2 to 5 cm. The CC phantom has a size 10 cm × 14 cm and includes 6 cylindrical cavities with length of 7.2 cm and diameters ranging from 0.6 to 1.2 cm. The IMPT evaluation using the HV phantom shows good agreement as compared to the dose distribution calculated with treatment planning system. The CC phantom also shows reasonable agreements for using different algorithms for each beam modalities. Conclusion: 3D printers with submillimiter resolutions are capable of printing complex phantoms for dose verification and QA in radiotherapy. As printing costs decrease and the technology becomes widely available, phantom design and construction will be readily available to any clinic for testing geometries that were not previously feasible.

60 APPLIED LIFE SCIENCES↗

Robotics System Process and Concept for On-orbit Assembly for Potential Mars Sample Return

Proposed Mars Sample Return (MSR) missions would require on-orbit assembly of containment vessels to meet backward Planetary Protection requirements and transfer of the sample container through various stations and positions. Some operations would have to be performed autonomously, and others would require ground-in-loop decision-making stages and verification processes. One concept design for an Earth Return Orbiter (ERO) Capture, Contain, and Return System (CCRS) Transfer Mechanism (TM) is a multi-Degree of Freedom (DOF) manipulator that utilizes a passive End Effector (EE) to assist in containment vessel assembly. To converge on a feasible design, a robotic system process has been instantiated. This process is composed of three main phases: robotic problem definition (operating environment, operations/functions, system goals), robotic solution selection (trade studies on the number of degrees of freedom, number of mechanisms, types of mechanisms), robotic solution design, implementation, and verification and validation (kinematic configuration, robotic and kinematic analysis and topology optimization of components). As a final product of this process, a half-scale functional prototype of the TM was developed to demonstrate the end-to-end operation capability.

Strahle, Jackson W↗

GSV Annotated Bibliography

The following annotated bibliography was developed as part of the geospatial algorithm verification and validation (GSV) project for the Simulation, Algorithms and Modeling program of NA-22. Verification and Validation of geospatial image analysis algorithms covers a wide range of technologies. Papers in the bibliography are thus organized into the following five topic areas: Image processing and analysis, usability and validation of geospatial image analysis algorithms, image distance measures, scene modeling and image rendering, and transportation simulation models. Many other papers were studied during the course of the investigation including. The annotations for these articles can be found in the paper "On the verification and validation of geospatial image analysis algorithms".

99 GENERAL AND MISCELLANEOUS↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

Improvements to a Response Surface Thermal Model for Orion

A study was performed to determine if a Design of Experiments (DOE)/Response Surface Methodology could be applied to on-orbit thermal analysis and produce a set of Response Surface Equations (RSE) that predict Orion vehicle temperatures within 10 F. The study used the Orion Outer Mold Line model. Five separate factors were identified for study: yaw, pitch, roll, beta angle, and the environmental parameters. Twenty-three external Orion components were selected and their minimum and maximum temperatures captured over a period of two orbits. Thus, there are 46 responses. A DOE case matrix of 145 runs was developed. The data from these cases were analyzed to produce a fifth order RSE for each of the temperature responses. For the 145 cases in the DOE matrix, the agreement between the engineering data and the RSE predictions was encouraging with 40 of the 46 RSEs predicting temperatures within the goal band. However, the verification cases showed most responses did not meet the 10 F goal. After reframing the focus of the study to better align the RSE development with the purposes of the model, a set of RSEs for both the minimum and maximum radiator temperatures was produced which predicted the engineering model output within +/-4 F. Therefore, with the correct application of the DOE/RSE methodology, RSEs can be developed that provide analysts a fast and easy way to screen large numbers of environments and assess proposed changes to the RSE factors.

Miller, Stephen W.↗

Center for Extended Magnetohydrodrynamic Modeling

This work used the NIMROD code to solve two tokamak regimes found on the DIII-D tokamak. The first regime studied is the Quiescent H-mode regime that has the advantage of enabling tokamak high performance without the deleterious effects of Edge Localized Modes (ELMs). ELMs are a possible impediment to the success of tokamaks as a burning plasma reactor and the QH mode regime provides a mechanism for avoiding it. The QH mode achieves this state due to the appearance of long wavelength instability that saturates instead of reaching an ELM state. NIMROD simulations were able to describe many of the features of a particular discharge, including the importance of shear flow in reaching the state, the role of the parallel heat flux to decorrelate the temperature and velocity fluctations, and in the correlation of density and velocity fluctations to provide the density pumpout. This work resulted in two direct publications and an invited talk. Progress towards these publications resulted in two more publications (verification and solving the Grad-Shafranov equation with scrape-off-layer currents). The second regime studied was the Giant Sawtooth regime whereby energetic particles affect the stability of the 1/1 mode. This work resulted in performance improvements of NIMROD's energetic particle algorithms, and improvements to the drift-kinetic equation infrastructure used by both continuum and energetic particle closure methods. The studies proved more computationally demanding than expected because as the 1/1 is stabilized, the near marginal conditions cause long simulations times. Publication of this work is in progress under other funding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards 3D printed multifunctional immobilization for proton therapy: Initial materials characterization

Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-specific structure. In this first step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes. Methods: Using four different 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominal dimension of 20 × 20 × 80 mm{sup 3} were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young’s modulus. To investigate the effect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρ{sub e}, the effective atomic number Z{sub eff}, and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coefficients, while proton irradiations were performed to measure the proton range shift of the samples. The directional dependence of these properties was investigated by performing the irradiations for different orientations of the samples. Results: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young’s moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT-based characterization yielded Z{sub eff} ranging from 5.91 to 10.43. The SPR and ρ{sub e} both ranged from 0.6 to 1.22. The measured photon attenuation coefficients at clinical energies scaled linearly with ρ{sub e}. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Z{sub eff}. As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials. Conclusions: In this study, the first step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical workflow for the first time: from the material printing to DECT characterization with a verification through beam measurements. Besides a proof of concept for beam modification, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in-house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Non-nuclear Component Signatures for Warhead Dismantlement Confirmation

The verification of warhead dismantlement is expected to be an important component in future arms reduction treaties. Historic approaches developed with future arms control treaty verification in mind often involve intrusive measurements, process monitoring, and/or inspector presence to provide confidence that an authentic warhead has been dismantled. This work explores the possibility of reducing the negative impacts of these invasive approaches while also delivering a method that is more likely to provide non-sensitive data that can be shared with not only other nuclear weapons states but also non-nuclear weapons states partners. This work explores a novel approach for verifying dispositioned non-nuclear weapon components, providing confidence post-dismantlement that a treaty accountable item that was dismantled was in fact a treaty-relevant nuclear weapon system as declared. This method provides an alternative to intrusive inspection processes in nuclear weapons production environments, which would require significant changes to the host’s operational behaviors. It achieves this by identifying intrinsic neutron-induced signatures of non-nuclear components to determine their authenticity and estimate the duration they were exposed within a nuclear weapons system using technologies that are already in use for other national security applications. Intrinsic radiation effects studies are already a part of the stockpile aging and surveillance evaluations. However, none of these technologies and approaches have been previously considered for verification applications of non-nuclear component disposition. In this report, we introduce modeling studies that have been used to identify the most promising candidate parts and materials with signatures that are measurable and actionable. These models have been validated with laboratory measurements of signatures induced by the exposure of candidate materials to neutrons over a range of times. Predictive modeling then demonstrates the methodology for estimating exposure times and/or limits. Laboratory measurements of authentic non-nuclear parts from a dismantled warhead demonstrate the feasibility of employing these signature measurements. And finally, a concept of operations (CONOPS) for the potential use of this methodology is presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗