Search NASA⌕ Search

SEARCH · Search NASA

Results for “appendix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

UT Austin's 2022 Sandia Day (Summary Report)

On March 30th and 31st, 2022, the University of Texas at Austin (UT) Office of the Vice President for Research (OVPR) hosted Sandia National Laboratories (Sandia) for “Sandia Day at UT Austin” to understand the status of the strategic partnership and explore opportunities for partnership growth. The event brought together more than 115 UT and Sandia participants including executive leadership, researchers, faculty, staff, and students. Sandia Day primarily consisted of a half-day leadership meeting, a research poster session and networking event, and three break-out sessions focused on strategic priority areas: Microelectronics, Energy and Climate Security, and High-Performance and Edge Computing. Appendix A contains the full Sandia Day agenda. Additional meetings and workshops (adjunct meetings) were held in conjunction with Sandia Day to maximize partnership exploration. Adjunct meetings were Hypersonics, Decarbonization, Disinformation, and Battery Workshops. A summary of Sandia Day events, sessions, and meetings follows.

42 ENGINEERING↗

United States Nuclear Data Program Annual Report for FY2021

The US Nuclear Data Program (USNDP) Annual Report for Fiscal Year 2021 (FY21) summarizes the work of USNDP for the period of October 1, 2020 through September 30, 2021, with respect to the Work Plan for FY21 that was prepared in 2019. The Work Plan and Final Report for USNDP are prepared for the DOE Office of Science, Office of Nuclear Physics. The support for the nuclear data activity from sources outside the nuclear data program is described in the staffing table and in Appendix A. This leverage amounts to about 3.24 FTE scientific, to be compared with 25.095 FTEs at USNDP units funded by the DOE Office of Science, Office of Nuclear Physics. Since it is often difficult to separate accomplishments funded by various sources, some of the work reported in the present report was accomplished with nuclear data program support leveraged by other funding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAND Report Guide

This SAND Report Guide offers support to authors, technical writers, principal investigators, and others involved in the process of creating, formatting, or refining a SAND Report. It details what you need to know before you begin compiling a SAND Report, directs you to the SAND Report templates, outlines the order of elements in a SAND Report, and explains what to do when your report is completed and ready for Review and Approval and subsequent distribution. Supporting information is provided in the appendix, such as where to get technical assistance, trademarks, Microsoft Word, and equations.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A Note on the Probability of Initiation Problem

The purpose of this note is to draw attention to Pál for his derivation of the Pál-Bell equation which is used by LLNL and LANL to model Probability of Initiation (POI) problems. Both laboratories credit the equation to Bell and Lee. Although the equation formulated by Bell and Lee and the equation derived by Pál appear to be the same, the equation by Bell and Lee is flawed. Scattering, which was absent in Bell’s original formulation of a POI problem, was later introduced by Bell and Lee by replacing a fission term with a scattering term. Such a replacement, however, leads to an incorrect average number $\overline{v}$ of neutrons that is produced in a fission event. By approaching a POI problem from probabilistic point of view, Pál formulates the problem as a branching process that i) describes the growth of a population of neutrons in a fissile medium, and ii) predicts $\overline{v}$ correctly. There are five reasons for writing this report. The first is to clarify the failing in Bell and Lee’s derivation. The second is to establish the origin of the equation used by the laboratories. The third is to elucidate the fixed point technique formulated by Mokhtar-Kharroubi to solve the Pál-Bell equation. The fourth is to derive the α eigenvalue that is associated with a super-critical situation. The fifth is to describe in the Appendix a second order positivity preserving technique that accelerates the convergence of the first order fixed point method developed by Mokhtar-Kharroubi.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ASME Code Revisions to Incorporate 316H and Alloy 617 Viscoplastic Constitutive Models to Section III, Division 5 and Code Case N-898

This report provides a final status update on work to develop and implement two new constitutive models for 316H stainless steel and the Ni-based Alloy 617 in Nonmandatory Appendix Z to the Section III, Division 5, Subsection HB, Subpart B ASME Boiler & Pressure Vessel Code rules covering the design and construction of Class A high temperature nuclear reactor components. This report summarizes the objections of the overall project and provides the final versions of the constitutive models proposed for incorporation into the ASME Code. The report also provides an update on the balloting status at ASME of the two proposed constitutive models. As of the time of writing (July 2022) the models are on-track to be approved by ASME after the August 2022 Code Week. If so, this will mean the 316H model will be published in the 2023 edition of the Code and the A617 model available as part of a revised Code Case immediately

36 MATERIALS SCIENCE↗

Gear Test Assembly - Experimental Testing and Gear Analysis - FY2022

The Gear Test Assembly (GTA) is an experimental test article built for use in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). The GTA was the first test article to operate in METL, with the initial experimental campaign beginning in early 2019. A total of four experimental campaigns have been completed to-date, and the fifth is currently underway. This report will discuss the results of the four completed campaigns with gear analysis in the form of over-pin dimensions. Finally, information regarding Experimental Campaign #5 will be discussed. All over-pin measurements of the gears tested in sodium will be available in the Appendix.

42 ENGINEERING↗

Small Hydropower Interconnections: Analysis of Interconnection Processes

Small hydropower projects have faced the challenge of navigating the process to interconnect their generation source to electricity distribution and transmission grids. Small hydropower developers have found interconnection procedures to be opaque and ultimately result in unexpected cost surprises and long timelines. Noting these challenges, the U.S. Department of Energy Water Power Technologies Office enlisted Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to investigate the small hydropower interconnection landscape across the United States. After reviewing the status of small hydropower (“Small Hydropower Interconnections: Small Hydropower in the United States”) and the interconnection procedures across the United States (“Small Hydropower Interconnections: State Interconnection Processes”) in the first two white papers of this series, this paper uses recent data from small hydropower interconnection applications to benchmark the efficacy of the process. Using data from interconnection queues hosted by utilities, balancing authorities, independent system operators (ISOs), and regional transmission organizations (RTOs), this paper provides context for the costs, timelines, and types of upgrades required for small hydropower projects. Interconnection applications and study reports for small hydropower projects were analyzed to collect key pieces of information about the interconnection process, timeline, costs, and type of upgrades required for interconnection. Information sourced from the reports was entered into an Interconnection Benchmarking database (IBdb), which may be found in Appendix A.1. Information from this database was used to evaluate the performance and challenges associated with interconnecting small hydropower projects. This white paper presents a description of the sources contained in the interconnection database (Section 2.0), an analysis of the interconnection timeline (Section 3.0), an evaluation the cost of interconnection upgrades (Section 4.0), and a description of the types of infrastructure upgrades (Section 5.0). The final paper in this series (“Small Hydropower Interconnections: Best Practices”) will use the analysis described here to outline best practices for interconnection processes that will help overcome barriers to future small hydropower development.

13 HYDRO ENERGY↗

Report Series: Evaluation, Finding Of Effect, And Mitigation Documentation For Building 23-109, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-109, the Mercury Fire Station/Maintenance/Housing Office (Nevada State Historic Preservation Office [SHPO] Resource No. B15235) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The NNSA/NFO is implementing a long-term project to modernize the town of Mercury for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800. In 2018, Desert Research Institute (DRI) completed an architectural survey of the town of Mercury. This effort resulted in the identification, recordation, and evaluation of the Mercury Historic District (MHD, SHPO Resource No. D230), including the identification of its contributing elements (Reno et al. 2018). The MHD was recommended eligible for listing in the National Register of Historic Places (NRHP, National Register) under the Secretary of the Interior’s (SOI) Significance Criteria A and C, as defined in 36 CFR Part 60.4, as a significant concentration of buildings and structures with a direct and important association with Cold War-era nuclear testing from 1951 through 1992. It has not been evaluated under Criteria B and D to date. As part of a larger modernization program for Mercury, the NNSA/NFO and the SHPO executed the 2018 Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (Mercury PA). The Mercury PA includes streamlined Section 106 procedures for undertakings in the MHD based on contributing element categories. Building 23-109 is identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of Section 106 compliance and subject to the stipulations of the Mercury PA. Per Stipulation VI of the Mercury PA, when the Area of Potential Effect (APE) for an undertaking includes Category I elements, the NNSA/NFO must evaluate the Category I elements for individual NRHP eligibility under all of the SOI Significance Criteria prior to initiating any activity that may affect the elements. The purpose of this report is to evaluate Building 23-109 as a potential individually eligible historic property in fulfillment of Stipulation VI of the Mercury PA. The evaluation detailed herein concludes that Building 23-109 is not individually eligible for listing in the NRHP. Although it retains some aspects of integrity and continues to contribute to the MHD, it is not individually significant under any of the SOI Significance Criteria.

54 ENVIRONMENTAL SCIENCES↗

An Architectural Survey of the REECo Maintenance Compound, Area 6, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to install a 26.45-mile-long 138-kilovolt (kV) transmission line on the Nevada National Security Site (NNSS) in Nye County, Nevada. This new transmission line will upgrade the electrical transmission system and provide reliable power between Mercury Switching Station in Area 23 and the U1a Facility in Area 1. The proposed upgrade to the power transmission system constitutes an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. A portion of this new transmission line will cross the western perimeter of the Reynolds Electrical and Engineering Company (REECo) Maintenance Compound located in Area 6 of the NNSS. This compound with its trade shops, storage sheds, and yards served as a general construction facility that supported nuclear testing activities on the NNSS from 1967 to 1992. Although three architectural resources in the compound have previously been recorded and evaluated for the National Register of Historic Places (NRHP), other resources within it have not, nor has the compound been recorded and evaluated as a potential district. The State Historic Preservation Officer (SHPO) concurred with NNSA/NFO’s determination that the unevaluated REECo Maintenance Compound will be adversely affected by the proposed undertaking (Reed 2021). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-22NA25553 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Installation of a 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility and the Removal of the Historic 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility in Areas 1, 3, 5, 6, and 23 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. This architectural survey report was prepared in accordance with MOA Stipulation III.B. It describes the origins, history, layout, and functions of the REECo Maintenance Compound during the Cold War and identifies contributing and noncontributing resources. The report defines a district boundary based on archival research and the field survey and concludes with an appendix that presents digital color images of the compound with descriptions and a map key showing image viewpoints and directions. Although none of the architectural resources are recommended individually eligible, the district evaluation concludes the REECo Maintenance Compound is eligible as a historic district for listing in the NRHP under the Secretary of the Interior’s Significance Criteria A and C at the local level. The historic district retains all seven aspects of integrity and conveys its significance under the abovementioned criteria.

138 kV↗

Report Series: Evaluation, Finding Of Effect, And Mitigation Documentation For Building 23-113, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-113 in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15236), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada. Demolition of Building 23-113 is part of the long-term project to modernize the town of Mercury on the NNSS for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800. In 2018, Desert Research Institute (DRI) completed an architectural survey of the town of Mercury. This effort resulted in the identification, recordation, and evaluation of the Mercury Historic District (MHD, SHPO Resource No. D230), including the identification of its contributing elements (Reno et al. 2018). The MHD was recommended eligible for listing in the National Register of Historic Places (NRHP, National Register) under the Secretary of the Interior’s (SOI) Significance Criteria A and C, as defined in 36 CFR Part 60.4, as a significant concentration of buildings and structures with a direct and important association with Cold War-era nuclear testing from 1951 through 1992. It has not been evaluated under Criteria B and D to date. As part of a larger modernization program for Mercury, the NNSA/NFO and the SHPO executed the 2018 Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (the Mercury PA). The Mercury PA includes streamlined Section 106 procedures for undertakings in the MHD based on contributing element categories. Building 23-113 is identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of Section 106 compliance and subject to the stipulations of the Mercury PA. Per Stipulation VI of the Mercury PA, when the Area of Potential Effect (APE) for an undertaking includes Category I elements, the NNSA/NFO must evaluate the Category I elements for individual NRHP eligibility under all of the SOI Significance Criteria prior to initiating any activity that may affect the elements. Therefore, the purpose of this report is to evaluate Building 23-113 as a potential individually eligible historic property in fulfillment of Stipulation VI of the Mercury PA. The evaluation detailed herein concludes that although Building 23-113 is significant at the local level for its important role as a recreational facility on the NNSS, the building lacks sufficient integrity to convey its significance. It is not individually eligible for listing in the NRHP at any level. The building remains eligible as a contributing element to the MHD.

54 ENVIRONMENTAL SCIENCES↗

Safety Testing of AGR-5/6/7 Compacts 2-2-2 and 2-2-4

Compacts 2-2-2 and 2-2-4 from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s final irradiation campaign (AGR-5/6/7) were each separately subjected to a thermal soak at 1600°C for 300 h under flowing helium to simulated conditions experienced during a postulated high-temperature gas-cooled reactor (HTGR) depressurization conduction cooldown event. The safety testing of the fuel compacts’ performance under accident conditions was conducted in the Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF), which utilizes a stand-alone hot cell at the Irradiated Fuels Examination Laboratory (IFEL). The CCCTF heats fuel to temperatures up to 1900°C in a non-oxidizing environment while continuously monitoring the sweep gas for radioactive 85 Kr to detect release levels associated with hermetic failure of the tristructural-isotropic (TRISO) coating surrounding each fuel kernel. In addition, certain metallic radionuclides that escape the fuel compact are collected on deposition cups that are periodically exchanged with a new cup to obtain information on the overall retention behavior of the TRISO coating layers. Because cesium can diffuse through intact pyrocarbon layers, abnormal degradation of the silicon carbide (SiC) layer in the absence of holistic TRISO coating failure is indicated by release of 134 Cs at levels equivalent to an individual particle inventory in the absence of significant 85 Kr release (Hunn et al. 2014). Additional description of the CCCTF system is provided in Appendix A.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New equations of state for saturated tuff based on the CHEST model

The CHemical Equilibrium for Saturated Tuff (CHEST) model was originally presented in Ref. 1, with numerical results depicted in Figure 1 and tabulated in Appendix B of that work. The results consisted of specific internal energy as a function of pressure and specific volume, E(P, V), spanning the domain P = 10 –4 – 10 4 kbar and V = 0.17 – 752 cm 3 /g (ρ = 1.33 × 10 –3 – 5.9 g/cm 3 ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facility Safety Plan – Building 225

B225 is operated by the Weapons and Complex Integration (WCI) Directorate and is classified as a Low Hazard facility for radiological hazards and Light Science Industry (LSI) for chemical, radiation generating devices (RGDs) and industrial hazards. Explosives and biological hazards are not authorized for B225. B225 is located in the southwest quadrant of Lawrence Livermore National Laboratory (LLNL) less than 600 meters from the nearest site boundary. B225 is a single-story concrete tilt-up building with a steel deck roof. The primary mission of this facility is to apply nondestructive evaluation (NDE) methods to materials, components, and assemblies. B225 also contains the polymer additive manufacturing laboratories. The floor plans for B225 are provided in Appendix A.

99 GENERAL AND MISCELLANEOUS↗

AERMOD Screening Dispersion Factors for INL Facilities

This engineering calculations and analysis report (ECAR) documents the calculation of screening level air dispersion factors (DFs) for use in identifying Idaho National Laboratory (INL) air pollutant sources that would not be of concern relative to state of Idaho Department of Environmental Quality (DEQ) significant impact levels for toxic air pollutants (IDAPA 2020). A DF (in units of s/m 3 ) is the maximum time-averaged model-predicted air concentration (g/m 3 ) at an ambient-air receptor location divided by a unit source release or emission rate (1 g/s). DFs were calculated for a generic pollutant released from facilities at the INL Site and the Idaho Falls Research Education Campus (REC) using the Environmental Protection Agency (EPA)-recommended AERMOD air-dispersion model (EPA 2019a) and site-specific meteorological data. The use of AERMOD for air quality analyses is specified by EPA in Appendix W of 40 CFR Part 51, Guideline on Air Quality Models, and by DEQ in their air modeling guidance (DEQ 2013). DFs were calculated for 1-hour, 3 hour, 8-hour, 24-hour, monthly, and annual averaging times.

99 GENERAL AND MISCELLANEOUS↗

Eddy Current Power Dissipation at the Edge of a Thin Conductive Layer

A method used to solve the problem of water waves on a sloping beach is applied to a thin conducting half plane described by a thin layer impedance boundary condition. The solution for the electric field behavior near the edge is obtained and a simple fit for this behavior is given. This field is used to determine the correction to the impedance per unit length of a conductor due to a sharp edge. The results are applied to the strip conductor. The final appendix also discusses the solution to the dual-sided (impedance surface & perfect conductor surface) half plane problem.

42 ENGINEERING↗

Ames National Laboratory Annual Site Environmental Report for CY2021

The primary purpose of this report is to summarize the performance of Ames National Laboratory’s environmental programs, present highlights of significant environmental activities, and confirm compliance with environmental regulations and requirements for calendar year 2021. This report is a working requirement of Department of Energy Order 231.1B, Environment, Safety and Health Reporting. It includes descriptions of the Laboratory’s site, mission, the status of its compliance with applicable environmental regulations, its planning and activities to maintain compliance, and a comprehensive review of its environmental protection, surveillance and monitoring activities. Ames National Laboratory is located on the campus of Iowa State University (ISU) and occupies 13 buildings owned by the Department of Energy (DOE). See the Laboratory’s Web page for location and Laboratory overview. The Laboratory also leases space in ISU owned buildings. In 2021, the Laboratory accumulated and disposed of hazardous waste under a U.S. Environmental Protection Agency (EPA) issued generator number. All waste was handled according to applicable EPA, State, and local regulations and DOE Orders. The Laboratory operates as a Small Quantity Generator (SQG) of hazardous waste. There were no radiological air emissions or exposures to the general public due to Laboratory activities in 2021 (See U.S. Department of Energy Air Emissions Annual Report in Appendix A.) The Laboratory has an established Environmental Radiological Protection Program (Plan 10200.041) per DOE Order 458.1 requirements. Plans, policies, and procedures are in place to protect the public and the environment against undue risk from radiation associated with DOE radiological activities. As indicated in prior Site Environmental Reports, formal pollution prevention awareness, waste minimization and recycling programs have been in practice since 1990, with improvements implemented most recently in 2017 with Iowa State University’s shift toward single-stream recycling. Included in recycling efforts are items such as batteries, monitors, corrugated cardboard, lamps, miscellaneous electronic office equipment, mixed paper, newsprint, food/beverage containers, and laboratory glassware. Ames National Laboratory also recycles/reuses salvageable metal, used oil, and foamed polystyrene peanuts, and encourages chemical redistribution and sharing among research groups. Ames National Laboratory reported its contractual performance to DOE-Ames Site Office (AMSO) through the Laboratory’s Performance Evaluation Measurement Plan (PEMP), and a performance level of “B+” was achieved in 2021 for Sustain Excellence and Enhance Effectiveness of Integrated Safety, Health, and Environmental Protection As reported in Site Environmental Reports for prior years, the Laboratory’s Environmental Management System (EMS) has been integrated into the Laboratory’s Integrated Safety Management System (ISMS) since 2005. The integration of EMS into Laboratory business practices allows the Laboratory to systematically review, address and respond to environmental impacts. In addition to DOE-identified objectives and targets, the EMS Steering Committee recommends annual environmental goals for the Laboratory. Due to the COVID-19 pandemic and limited onsite work staff, goals of reducing water usage and travel/commuting to promote the reduction of scope 3 greenhouse gases were achieved. All contract deliverables and environmental compliance activities were still met during this time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Industrial Stormwater Pollution Prevention Plan (SWPPP) for SNL/CA Reporting Year 2022-2023

The Sandia National Laboratories, California (SNL/CA) site comprises approximately 410 acres and is located in the eastern portion of Livermore, Alameda County, California. The property is owned by the United States Department of Energy and is being managed and operated by National Technology & Engineering Solutions of Sandia, LLC. The facility location is shown on the Site Map(s) in Appendix A. This Stormwater Pollution Prevention Plan (SWPPP) is designed to comply with California’s General Permit for Stormwater Discharges Associated with Industrial Activities (General Permit) Order No. 2015-0122-DWQ (NPDES No. CAS000001) issued by the State Water Resources Control Board (State Water Board) (Ref. 6.1). This SWPPP has been prepared following the SWPPP Template provided on the California Stormwater Quality Association Stormwater Best Management Practice Handbook Portal: Industrial and Commercial (CASQA 2014). In accordance with the General Permit, Section X.A, this SWPPP contains the following required elements: Facility Name and Contact Information; Site Map; List of Significant Industrial Materials; Description of Potential Pollution Sources; Assessment of Potential Pollutant Sources; Minimum BMPs; Advanced BMPs, if applicable; Monitoring Implementation Plan (MIP); Annual Comprehensive Facility Compliance Evaluation (Annual Evaluation); and, Date that SWPPP was Initially Prepared and the Date of Each SWPPP Amendment, if Applicable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wet Waste Hydrothermal Liquefaction and Biocrude Upgrading to Hydrocarbon Fuels: 2022 State of Technology

Data from Pacific Northwest National Laboratory’s (PNNL) conversion hydrothermal liquefaction (HTL) program for wet waste was used to update the pathway techno-economic analysis (TEA) for the fiscal year 2022 State of Technology (2022 SOT). Figure S.1 shows the modeled minimum fuel selling price (MFSP) for the 2022 SOT, along with the previous years’ SOTs (Snowden-Swan et al. 2020, 2021, 2022). These costs are for a HTL plant scale of 110 dry ton/day sludge feed and a larger centralized upgrading plant scale of 38 million gallons/year biocrude feed, commensurate with the design case. All costs were updated to 2020 dollars. Corresponding cost breakdowns and technical parameters for each case are given in Appendix B. In previous years’ analyses options with and without ammonia (NH 3 ) stripping treatment of the HTL aqueous phase recycle stream were included in the analysis to account for cases with direct recycle of untreated HTL aqueous phase back to the wastewater treatment plant. In the FY21 SOT assessment however, system boundaries for the analysis were adjusted to reflect separate ownership/operatorship for the HTL plant and with that, nutrient surcharge fees associated with disposal of the aqueous phase wastewater to a municipal sewer system were incorporated to provide an improved accounting of true disposal costs for a standalone plant. With these changes, there is no significant cost difference between the case including ammonia removal and the case excluding ammonia removal and therefore the “no NH3 removal” options will not be included in the 2022 and future SOTs.

09 BIOMASS FUELS↗